Page 11
Product overview Bus Terminals
Digital output: KL2xxx | KS2xxx Signal 1-channel
2-channel
4-channel
5 V DC 24 V DC
KL2012 | KS2012
535
IMAX = 0.5 A
KL2032 | KS2032
KL2022 | KS2022
535
IMAX = 2.0 A
534
IMAX = 0.5 A
KL2212 | KS2212
KL2124 | KS2124
537
KL2114 | KS2114
534
IMAX = 0.5 A
535
IMAX = 0.5 A, diagnostic,
KL2134 | KS2134
534
IMAX = 0.5 A
KL2184 | KS2184
538
IMAX = 0.5 A, negative switching
Bus Terminal protected sensor supply
KL2442
KL2404 | KS2404
534
2 x 4 A/1 x 8 A
533
IMAX = 0.5 A, 4 x 2-wire
KL2424 | KS2424
533
IMAX = 2.0 A, 4 x 2-wire
KL2904
537
TwinSAFE, 4 safe outputs
470
24 V AC/DC
KL2784 | KS2784
539
IMAX = 2.0 A, solid state relay
125 V AC
KL2612 | KS2612
KL2794 | KS2794
539
IMAX = 2.0 A, solid state relay
540 relay, change-over
230 V AC
KL2641
540
KL2602 | KS2602 relay, make contact, manual, 16 A relay, make contact
KL2751 | KS2751
KL2652 | KS2652
549 universal dimmer, 300 W
KL2761 | KS2761
549
KL2712 | KS2712
541
545
KL2732 | KS2732
541
KL2702 | KS2702
545 solid state relay, 0.3 A
544 triac solid state relay, 3 A
KL2622 | KS2622 relay, make contact, no power cont.
relay, change-over universal dimmer, 600 W
KL2701 | KS2701
541
KL2722 | KS2722
544 triac, mutually locked outputs
544 triac, mutually locked outputs,
KL2692 | KS2692
546 cycle monitoring (watchdog)
no power contacts
400 V AC
KL2631 | KS2631
541 relay, make contact
PWM
KL2502 | KS2502
548
24 V DC, 0.1 A
KL2535 | KS2535
KL2512 | KS2512
548
24 V DC, 1.5 A, negative switching
548
KL2545 | KS2545
548
50 V DC, 3.5 A, current-controlled
50 V DC, 3.5 A, current-controlled
DC motor
KL2532 | KS2532
KL2552 | KS2552 output stage
24 V DC, 1 A
Frequency outp.
KL2521
547
Stepper motor
KL2531 | KS2531
550
IMAX = 1.5 A
KL2541 | KS2541
550
IMAX = 5 A
AC motor speed
KL2791 | KS2791 controller
230 V AC, 200 VA
552
552
50 V DC, 5 A
553
KLxxxx: Standard Bus Terminals, KSxxxx: Bus Terminals with pluggable wiring level
BECKHOFF New Automation Technology
We reserve the right to make technical changes.
Page 12
KM2xxx 8-channel 532
IMAX = 0.5 A
KL2488 | KS2488
KL2872
4-, 16-, 32-, 64-channel 535
IMAX = 0.5 A, flat-ribbon cable
KL2872-0010
538
IMAX = 0.5 A, flat-ribbon cable,
IMAX = 0.5 A, negative switching
IMAX = 0.5 A, 8 x 0 V
536
IMAX = 0.5 A, 32-channel
KL1859 KL2808
536
KM2004 negative switching
538
KM2002 IMAX = 0.5 A, 16-channel
533
533
8 inputs, 8 outputs, filter 3.0 ms,
KM2008 type 3, IMAX = 0.5 A
IMAX = 0.5 A, 64-channel
KL2809 IMAX = 0.5 A
533
KL2889 IMAX = 0.5 A, negative switching
538
Bus Terminal
KL2408 | KS2408
16-channel
536
KM2042
535
IMAX = 0.5 A, 16-channel, D-sub
KM2604
471
542 relay, 16 A, 4-channel
KM2642
KM2614
542 relay, 16 A, 4-channel, manual operation
543
KM2652
543 relay, 6 A, manual/automatic operation, relay, 6 A, manual/automatic operation, relay state readable switch and relay state readable
KM2774
545 triac outputs for 4 blind motors
We reserve the right to make technical changes.
BECKHOFF New Automation Technology
Page 13
Product overview Bus Terminals
Analog input: KL3xxx | KS3xxx, KM3xxx Signal 1-channel
2-channel
4-channel
0…2 V,
KL3172 | KS3172 557
KL3172-0500
0…500 mV
0…2 V, 16 bit, 0.05 %
0…500 mV, 16 bit, 0.05 %
±2 V
KL3182 | KS3182 557
8-channel
557
16 bit, 0.05 %
Bus Terminal
0...10 V
± 10 V
472
KL3061 | KS3061 556
KL3062 | KS3062 556
KL3064 | KS3064 556 single-ended, 12 bit single-ended, 12 bit single-ended, 12 bit
KL3162 | KS3162 557
KL3464 | KS3464 556
16 bit, 0.05 % single-ended, 12 bit single-ended, 12 bit
KL3001 | KS3001 554
KL3002 | KS3002 554
KL3404 | KS3404 555
KL3408 | KS3408 555 differential input, 12 bit differential input, 12 bit single-ended, 12 bit single-ended, 12 bit
KL3102 | KS3102 555 0...20 mA
4...20 mA
KL3468 | KS3468 557
KL3132 | KS3132 555 differential input, 16 bit
16 bit, 0.05 %
KL3011 | KS3011 558
KL3041 | KS3041 559
KL3012 | KS3012 558
KL3112 | KS3112 559
KL3444 | KS3444 558
KL3448 | KS3448 559 differential input, 12 bit with sensor supply, 12 bit differential input, 12 bit differential input, 16 bit single-ended, 12 bit single-ended, 12 bit
KL3042 | KS3042 559
KL3142 | KS3142 559
KL3044 | KS3044 558 with sensor supply, 12 bit
16 bit, 0.05 % single-ended, 12 bit
KL3021 | KS3021 560
KL3051 | KS3051 561
KL3022 | KS3022 560
KL3052 | KS3052 561
KL3454 | KS3454 560
KL3458 | KS3458 561 differential input, 12 bit with sensor supply, 12 bit differential input, 12 bit with sensor supply, 12 bit single-ended, 12 bit single-ended, 12 bit
KL3122 | KS3122 561
KL3152 | KS3152 561
KL3054 | KS3054 560 differential input, 16 bit
16 bit, 0.05 %
Resistance ther-
KL3201 | KS3201 562
KL3202 | KS3202 563
KL3222
562
KL3204 | KS3204 563 single-ended, 12 bit
KL3208-0010 mometer (RTD)
PT100…1000, Ni100, 16 bit
PT100…1000, Ni100, 16 bit
PT100, 4-wire connection,
PT100…1000, Ni100, 16 bit
PT1000, Ni1000, PTC
563
KL3228 | KS3228 563 high-precision
PT1000, Ni1000, PTC
Thermo-
KL3311 couples/mV type J, K, L,…U, 16 bit
Resistor bridge
KL3351 | KS3351 566
KL3312
564
KL3314
565 type J, K, L,…U, 16 bit strain gauge, 16 bit
565 type J, K, L,…U, 16 bit
KL3356 | KS3356 566 strain gauge, 16 bit, self-calibration
Oscilloscope
KL3361 | KS3361 567
KL3362 | KS3362 567 oscilloscope terminal, oscilloscope terminal,
±16 mV
±10 V
Measurement
KL3681 | KS3681 569
KL3403 | KS3403 568
KL3403-0010 technology digital multimeter terminal,
3-phase power measure-
3-phase power measure- ment terminal, 1 A ment terminal, 5 A
18 bit
Pressure
KM3701 measuring
KM3701-0340 570
KM3702 differential pressure differential pressure relative pressure measuring, relative pressure measuring, measuring, -100…+100 hPa measuring, up to 340 hPa
7,500 hPa
-1,000…+1,000 hPa
570
571
KM3712
568
571
KLxxxx: Standard Bus Terminals, KSxxxx: Bus Terminals with pluggable wiring level
BECKHOFF New Automation Technology
We reserve the right to make technical changes.
Page 14
Analog output: KL4xxx | KS4xxx
KM4xxx
Signal KL4001 | KS4001
2-channel 574
12 bit, potential-free output
KL4002 | KS4002
4-channel 574
12 bit
KL4004 | KS4004
8-channel
12 bit
KL4404 | KS4404
KL4031 | KS4031
572
12 bit, potential-free output
KL4032 | KS4032
572
12 bit
KL4034 | KS4034
575 manual/automatic operation
575
12 bit
± 10 V
2-channel KM4602
574
KL4408 | KS4408
575
12 bit
Bus Terminal
1-channel 0...10 V
573
12 bit
473
KL4434 | KS4434
573
12 bit
KL4132 | KS4132
KL4438 | KS4438
573
12 bit
573
16 bit
KL4494 | KS4494
573
2 x input, 2 x output, 12 bit
0...20 mA
KL4011 | KS4011
576
12 bit
KL4012 | KS4012
576
12 bit
KL4414 | KS4414
577
12 bit
KL4112 | KS4112
KL4418 | KS4418
577
12 bit
577
16 bit
4...20 mA
KL4021 | KS4021 12 bit
578
KL4022 | KS4022
578
12 bit
KL4424 | KS4424 12 bit
We reserve the right to make technical changes.
579
KL4428 | KS4428
579
12 bit
BECKHOFF New Automation Technology
Page 15
Product overview Bus Terminals
Special functions: KL | KS5xxx, KL | KS6xxx
Power terminals: KL8xxx
Safety terminals: KLx904
Signal
Signal
Signal
KL5001 | KS5001 580
KL5051 | KS5051 580 measurement
SSI encoder interface bidirectional SSI switching capacity 5.5 kW,
TwinSAFE, encoder interface nominal current 0.9 to 9.9 A,
4-channel digital
KL5101 | KS5101 582
KL5111 | KS5111 583 connection mechanism for input terminal, incremental encoder incremental encoder
Siemens contactors (Sirius
IEC 61508 SIL 3 and interface, differential input interface
3R series)
DIN EN ISO 13849-1:
Bus Terminal
Position
400 V AC 3~
KL8001
592
24 V DC
KL5151 | KS5151 583
KL1904
531
2008 PLe incremental encoder interface, 32 bit
KL5121 | KS5121 581
KL5152 | KS5152 583 incremental encoder inter-
2-channel incremental
KL8601 face with program. outputs encoder interface, 32 bit communication module
TwinSAFE,
Communi-
KL6001 | KS6001 584
KL6031 | KS6031 584 for Schneider TeSys U
4-channel digital cation serial interface RS232, serial interface RS232, output terminal,
19.2 kbaud
115.2 kbaud
IEC 61508 SIL 3 and
KL6011 | KS6011 585
KL6051 | KS6051 585
DIN EN ISO 13849-1:
serial interface TTY, data exchange terminal,
2008 PLe
20 mA current loop
32 bit
KL6021 | KS6021 585
KL6041 | KS6041 585 serial interface RS422/RS485, serial interface RS422/RS485,
KL8610
19.2 kbaud
115.2 kbaud adapter terminal for
474
KL6023
589
KL6021-0023 wireless adapter for
RS485 interface for
EnOcean radio technology
EnOcean signals
KL6581
KL6583
588
EnOcean master
588
IO-Link master wireless data exchange
593
Controller
KL6904
591
TwinSAFE Logic
588
Bus Terminal, with 4 digital outputs, and receiver
KM6551
537
Schneider TeSys U
EnOcean transmitter
KL6224 | KS6224 589
KL2904
593
IEC 61508 SIL 3 and
587
DIN EN ISO 13849-1: 2008 PLe terminal
KL6201 | KS6201 586 AS-Interface master terminal
KL6211 | KS6211 586 AS-Interface master terminal with power contacts
KL6301 | KS6301 589
KL6401 | KS6401 590
EIB Bus Terminal
LON Bus Terminal
KL6771 | KS6771 590
KL6811 | KS6811 590
MP-Bus master terminal
DALI/DSI master and power supply terminal
KLxxxx: Standard Bus Terminals, KSxxxx: Bus Terminals with pluggable wiring level
BECKHOFF New Automation Technology
We reserve the right to make technical changes.
Page 16
System terminals: KL9xxx | KS9xxx Signal
System
System
KL9010
Signal
Potential supply
24 V DC
KL9100 | KS9100
Power supply and accessories
598
594 bus end terminal
K-bus power supply, 2 A
598 terminal bus extension end terminal
KL9050
KL9110 | KS9110
594 diagnostic
598
KL9200
598
595 with fuse
595 diagnostic, with fuse
595
KL9515 | KS9515 input 24 V DC,
596 602
AS-Interface potential supply
KL9560 | KS9560
597 with electrical isolation
597
50 V DC
KL9570 | KS9570 500 µF, 50 V DC
595
120...230 V AC 603 surge filter terminal for field supply
KL9300 | KS9300
KL9160 | KS9160
594 595 with fuse
KL9260
599
595 diagnostic, with fuse
599
7 diodes, common cathode
KL9302 | KS9302
594
KL9250
603
4 diodes, potential-free
KL9301 | KS9301
KL9150 | KS9150 diagnostic surge filter terminal for system/field supply
Diode array
604 buffer capacitor terminal, shield terminal
KL9550 | KS9550
601 output 24 V DC, 0.1 A,
597 potential distribution terminal, 16 x 0 V DC
KL9540 | KS9540
602 input 24 V DC, potential distribution terminal, 16 x 24 V DC
KL9195 | KS9195
KL9528 | KS9528 AS-Interface power supply terminal potential distribution terminal, 8 x 0 V
KL9189
601 output 15 V DC, 0.5 A
KL9520 | KS9520
597 potential distribution terminal, 8 x 24 V
KL9188
601 output 12 V DC, 0.5 A
597
KL9185 | KS9185
KL9187 | KS9187
475 input 24 V DC, potential distrib. terminal, 8 x 24 V DC, 8 x 0 V DC
KL9186 | KS9186
601 output 10 V DC, 0.5 A
KL9512 | KS9512
596 potential distrib. terminal, only 2 power contacts
Filter
KL9510 | KS9510 input 24 V DC, potential distribution terminal
KL9184
601 output 8 V DC, 0.5 A
KL9210 isolation terminal
KL9180 | KS9180
KL9508 | KS9508 input 24 V DC,
595 shield terminal
KL9080
600 output 5 V DC, 0.5 A adapter terminal for power terminal KL8xxx
KL9070 | KS9070
KL9505 | KS9505 input 24 V DC, terminal bus extension coupler terminal
KL9060
600 input 24 V DC,
Bus Terminal
KL9020
KL9400 | KS9400
599 up to 400 V AC
KL9190 | KS9190
594
KL9290
595 with fuse
7 diodes, common anode
We reserve the right to make technical changes.
BECKHOFF New Automation Technology
Page 17
Potential feeder terminals enable to set up different potential groups.
Bus Coupler: the link between Bus Terminals and fieldbus Bus Terminals in 1-, 2-, 4-, 8- and 16-channel modularity with combinations of any desired types of signal
Bus Terminal
The Bus Terminal system
476
The I/O signals are wired in a decentralised way to fieldbus devices or centrally to the controller. The available manufacturer-specific fieldbus devices with fixed input/output configurations and design often make it necessary to use an entire group of devices with similar functions. This costly method of signal acquisition gives rise to high material, installation, planning and documentation costs as well as high costs for subsequent modification or expansion. Inventory management and service staff are put under unnecessary strain. Flexible and stable The Beckhoff Bus Terminal is an open and fieldbus-neutral I/O system consisting of electronic terminal blocks. The head of an electronic terminal block is the Bus Coupler with the interface to the fieldbus. Bus Couplers are available for the following bus systems: – EtherCAT, the fast real-time Ethernet fieldbus, – Lightbus, the fast fibre optic fieldbus, – PROFIBUS DP/FMS conforms to the European standard EN 50170, – Interbus, which has been on the market since 1987, – CANopen, multi-masters in the actuator/sensor area, – DeviceNet, the device bus with CAN technology, – ControlNet, the standardised fieldbus, – Modbus, the open fieldbus,
BECKHOFF New Automation Technology
–
Fipio, the fieldbus according to the WorldFIP standard, – CC-Link, the fieldbus for the Asian market, – SERCOS interface, the bus from the drives engineering field, – RS232/RS485, the network for the most economical solution, – Ethernet TCP/IP, the network bus, – Ethernet/IP, Industrial Ethernet solution from ODVA, – PROFINET, Industrial Ethernet solution from PNO, – USB, the fast interface for the laboratory. With the master terminals, fieldbus functionalities are also available in form of a standard Bus Terminal. This is particularly advantageous for bus systems that are integrated as subsystems into a higher-level system. It means that only one system is required for the subsystem and for the higher-level bus interface. Master terminals are available for the following bus systems: – AS-Interface, the sensor/actuator bus for the lower control level, – EIB, LON, DALI, i.e. the communication standards in building automation. Automation standard The Beckhoff Bus Terminal ensures that control cabinets and terminal boxes are constructed more economically. Using the 4-wire terminating system, all of the usual sensors and actuators with different types of signals can be connected directly without other connection systems. It is no longer necessary to wire the field devices between the first terminal connection in the control cabinet or in the terminal box and the controller. This significantly reduces the costs involved in controller design and saves space, material, work, and money. The field devices can be wired using the Beckhoff Bus Terminal system on site where the signals occur. Installation and wiring of the Beckhoff Bus Terminal is thus simple like that of a standard terminal block. The Bus Terminal can be connected to the controller by connecting a Bus Coupler via the fieldbus as required. The Beckhoff Bus Terminals have been tried and tested in a wide range of sectors worldwide, from machine construction to building management. Beckhoff Bus Terminal technology makes design, construction, wiring, commissioning and maintenance of equipment and machines very cost-effective. Design The robust housing, secure contacts and the solidly built electronics are prominent features of our components. A station consists of one Bus Coupler and up to 64 electronic terminal blocks. With the K-bus extension it is possible to operate up to 255 Bus Terminals on one Bus Coupler. The electronic terminal blocks are clipped onto the Bus Coupler. They connect
We reserve the right to make technical changes.
Page 18
Operation of up to 64 Bus Terminals on one Bus Coupler (255 with K-bus extension KL9020 and KL9050)
Bus end terminal
Fast and secure data connections by means of a serial terminal bus by simply latching together. This means that each electronic terminal block can be exchanged separately and can be mounted on a standard mounting rail. In addition to horizontal type mounting, all other mounting types are permitted in the majority of the cases. The Beckhoff Bus Terminal with its outside contour adjusts perfectly to the measurements of terminal boxes. The clear front panel of the terminal with light-emitting diodes for status display, plug-in contact labelling and detachable labelling fields guarantee clarity. The 3-wire system supplemented by a protective conductor terminal makes it possible to wire sensors/actuators directly. Free mix of signals The Beckhoff I/O system supports about 400 Bus Terminals and is thus probably the most comprehensive system on the market. The components enable users to operate mixed signal configurations without restriction at each station. This means that a single non-central input/output node can map all the necessary signals. Appropriate Bus Terminals are available for any digital or analog automation signal type, for currents and voltages with standardised signal levels and for PT100 and thermocouple signals. Intelligent devices can be connected via Bus Terminals with serial interfaces in accordance with RS232, RS485 or 20 mA TTY.
We reserve the right to make technical changes.
The fine granularity of the Bus Terminals enables bit-precise composition of the required I/O channels. The digital Bus Terminals are available as 2-, 4-, 8- or 16-channel terminals. In the 16-channel variant, digital input and output signals are arranged in an ultra-compact way within a standard Bus Terminal housing across a width of only 12 mm. The standard analog signals of -10…+10 V, 0…+10 V, 0…20 mA and 4…20 mA are all available as 1-, 2-, 4- and 8-channel variants within a standard housing. The system is thus highly modular and can be projected costeffectively with an accuracy down to a single channel. The KMxxxx terminal modules with plug-in wiring combine 16, 32 or 64 digital I/Os within a very small space and with high packing density.
Project engineering and parameterisation If the TwinCAT automation software from Beckhoff is used, the I/O stations can be integrated and parameterised conveniently via the TwinCAT System Manager. As a “configuration centre”, the System Manager links the PLC programs and the connected I/O channels.
Economical and small For the user, Beckhoff Bus Terminals offer independence from the particular fieldbus and terminal block design. Digital and analog signals can be mixed without restriction, starting with one or two signals per terminal. They replace manufacturer-specific designs and all the intermediate terminal positions. The Bus Terminal ensures transparency and flexibility. Distributors and terminal boxes become smaller, more economical, and in some cases can be omitted. Plants and machinery equipped with Beckhoff Bus Terminals offer significant competitive advantages.
BECKHOFF New Automation Technology
Bus Terminal
Power contacts for automatic transfer of supply voltage
477
Page 19
KLxxxx | The standard KL type Bus Terminals include electronics and connection level in a single housing.
KSxxxx | The KS series Bus Terminals feature a pluggable connection level enabling the complete wiring to be removed as a plug connector from the top of the housing for servicing.
The Bus Terminals with 16 terminal points offers a very high packing density in 12 mm.
Bus Terminal
Flexible connection system KLxxxx | Standard
KSxxxx | Pluggable wiring wiring
478
The Bus Terminal system offers different connection options for optimum adaptation to the respective application. The KLxxxx Bus Terminals include electronics and connection level in a single enclosure. The KSxxxx type Bus Terminals feature a pluggable connection level. The KM modules integrate a wide range of I/Os within a very small area. All terminal types are bus-neutral and can be combined as required. The standard KL Bus Terminals have been tried and tested for years. They feature integrated screwless spring loaded technique for fast and simple assembly.
The HD Bus Terminals (High Density) with 16 terminal points are distinguished by a particularly compact design, as the packaging density is twice as large as that of the standard 12 mm Bus Terminals. Singlewire conductors and conductors with a wire end sleeve can be inserted directly into the spring loaded terminal point without tools.
BECKHOFF New Automation Technology
The KS type Bus Terminals feature a pluggable connection level. The assembly and wiring procedure for the KS series is the same as for the KL series. The KS series Bus Terminals enable the complete wiring to be removed as a plug connector from the top of the housing for servicing. The lower section can be removed from the Bus Terminal assembly by pulling the unlocking tab. Insert the new component and plug in the connector with the wiring. This reduces the installation time and eliminates the risk of wires being mixed up. The familiar dimensions of the Bus Terminal only had to be changed slightly. The new connector adds about 3 mm. The maximum height of the Bus Terminal remains unchanged. The overview and nomenclature of the product names has been retained: The plug connector variant is identified in the part number by an additional letter. Conductor cross sections between 0.08 mm² and 2.5 mm² can continue to be used with the proven spring loaded technique. A tab for strain relief of the cable simplifies assembly in many applications and prevents tangling of individual connection wires when the connector is removed.
We reserve the right to make technical changes.
Page 20
KMxxxx | The KM type terminal modules feature pluggable wiring, combining 16, 32 or 64 digital I/Os in a very small area with high packing density.
with high packing density
More sensor and actuator functionality makes machines and systems more and more powerful. The Bus Terminal reliably meets increased requirements for I/O signals through its modularity and compact design. The existing Bus Terminal system is complemented by the compact version of the KMxxxx terminal module with increased packing density. In many areas of application, cost benefits can be realised through lower overall installed size and applicationspecific signal mix. The terminal modules are fully system-compatible. Like the Bus Terminals, they are bus-neu-
We reserve the right to make technical changes.
tral and can therefore be operated with any Beckhoff Bus Coupler or Bus Terminal Controller. Like the standard Bus Terminals, the KM modules are integrated in the I/O system and connected with the internal terminal bus (K-bus). Bus Terminals and terminal modules can be combined without restriction. Like for the Bus Terminals, no tools are required for the wiring. Spring-loaded terminals are used, however with connectors (cable cross section 0.5…1.5 mm²). The terminal modules combine 16, 32 or 64 digital inputs or outputs on a very small area. This compact and slimline design enables very high packing densities, leading to smaller control cabinets and terminal boxes. Digital l/O modules with up to 64 channels The KM modules are used, for example, in applications with high demand for standard signal types such as digital I/Os. The very compact digital KM1xxx and KM2xxx input/output terminal modules have 16, 32 or 64 channels. Each I/O connector has eight inputs or outputs. LEDs integrated in the connector indicate the signal state for each channel directly at the wire. Depending on the connection type, the terminal modules are available with 1- or 3-pin plug connector and enable connection with 1, 2 or 3 wires. Customer-specific signal mix In addition to the standard I/O types, the terminal modules are also available as customerspecific types, e.g. for use in production machines with identical I/O combinations. The combination terminal modules consolidate typical automation signal combinations. This enables smaller physical size and quantity of parts with significant cost savings.
Interface standards within the Bus Terminal In addition to plug-in wiring, sensor-specific plug connectors such as D-sub, RJ 45 or BNC simplify the application of the Bus Terminal system. Sensors and actuators with pre-assembled connectors can be connected directly and quickly with the Bus Terminal system. Relay or power modules are also available, which are either equipped with standard relays or with integrated electronics to connect wattages up to 16 A.
BECKHOFF New Automation Technology
Bus Terminal
KMxxxx | Pluggable wiring
479