Bus Terminal features
Status LEDs for reliable and fast startup
Marking material for standard terminal blocks
Supply point for downstream inputs and outputs Detachable labelling fields for clear text labels
Power contacts connect the
Bus Terminal supply for sensors/actuators
480 automatically.
Supply point for Bus Couplers and downstream inputs and outputs
Bus Couplers represent a universal interface to the fieldbuses.
Terminal block design W x H x D (mm): 12 x 100 x 68
Assembly on 35 mm DIN mounting rail with no accessories
Ethernet TCP/IP
BECKHOFF New Automation Technology
We reserve the right to make technical changes.
Page 22
Screwless connection: using the reliable springloaded technique with vertical cable inlet
Master terminals enable the integration of subsystems such as AS-Interface. Contacts for data transmission and power supply to the K-bus vertical removal from terminal strip; release slide does not require a tool.
Bus Terminal
Symmetric release enables
481
Tongue and groove connection makes terminal strip structure secure and stable.
Fipio
Leading PE power contact
DALI
The 4-wire terminating system (signal, 24 V DC,
MP-Bus
0 V, PE) reduces assembly costs.
EIB We reserve the right to make technical changes.
LON BECKHOFF New Automation Technology
Page 23
Beckhoff Bus Terminals: The complete automation kit
Bus Coupler series BK, the link between Bus Terminals and fieldbus
The head station
Free mix of signals:
Potential feed of the Bus Terminals:
about 400 different terminals enable from Bus Coupler
Bus Terminals for configuration with fieldbus interface connection to all of different to Embedded PC common sensors potential groups.
Bus Terminal and actuators
Bus Terminal Controller series BC with integrated IEC 61131-3 PLC
482
Bus Terminals in
The terminal modules
1-, 2-, 4-, 8- and 16- with plug-in wiring channel modularity combine 16, 32 or 64 digital I/Os within a very small space and with high packing
Bus Terminal Controller series BX with integrated IEC 61131-3 PLC and extended interfaces density.
Embedded PC series CX for PLC and Motion Control applications
BECKHOFF New Automation Technology
We reserve the right to make technical changes.
Page 24
Integrated safety:
measurement capability the TwinSAFE Bus enables all relevant
Terminals enable electrical data of the the connection of all supply network to be common safety sensors measured.
and actuators.
Bus end terminal
The terminal bus extension enables the connection of up to 255 Bus Terminals (instead of 64) to a single station.
Bus Terminal
3-phase power
483
Bus Terminals with
Communication a maximum measure- terminals enable ment error of ±0.01% the integration of expand the range of subsystems such applications to high- as AS-Interface, precision measure-
RS232 and RS485.
ment technology.
The power terminal transforms a standard contactor into a motor protection relay with comprehensive diagnostic functions.
We reserve the right to make technical changes.
BECKHOFF New Automation Technology
Page 25
The coupler terminal KL9050 starts a further remote bus terminal block.
Via the K-bus extension, the Bus Coupler “Economy plus” enables the connection of up to 255 Bus Terminals.
Operation of up to 64 Bus Terminals
Operation of up to 64 Bus Terminals
Bus end terminal KL9010
K-bus extension via screened Industrial Ethernet cable with two RJ 45 plugs (distance up to 5 m)
Terminal bus extension, end terminal KL9020
Through the K-bus interconnection it is possible to connect a further 30 stations (total extension 155 m).
Bus Terminal
Terminal bus extension
484
The BKxxxx Bus Coupler links the bus systems to the modular, extendable electronic terminal blocks. One unit consists of one Bus Coupler, any number of terminals between 1 and 64, and a bus end terminal. The “Economy plus” and “Compact” series support all Bus Terminals of the Beckhoff system. It is also possible to operate up to 255 Bus Terminals on this Bus Coupler series with the K-bus extension. The Bus Terminal extension allows Bus Terminals to be located in up to 31 blocks in the control cabinet or in the application. With a distance of up to 5 m between the Bus Terminal blocks, the Bus Terminal system can be used over a wider area and helps save costs. The Bus Coupler recognises the terminals to which it is connected, and performs the assignment of the inputs and outputs to the bytes of the process image automatically. The blocks with terminal bus extensions are treated as one unit by the Bus Coupler. The extension is transparent for the fieldbus and higher-level systems. The system of Bus Coupler and Bus Terminal can be extended by replacing the end terminal KL9010 with the extension KL9020. The KL9020 makes available the K-bus signals in a RJ 45 socket for transmission onwards via a screened Industrial Ethernet cable. The coupler terminal KL9050 starts a further remote Bus Terminal block and provides the logical connection to the Bus Coupler via the Ethernet cable. 24 V DC, electrically isolated, for the field level can be input at this coupler terminal. The internal K-bus shares the same potential as the K-bus of the coupler. The KL9050 can be used via a second socket for the extension to the next Bus Terminal block. This Bus Terminal block starts in the same way as the one with a coupler terminal KL9050. This coupling works at up to 31 stations. The maximum distance between two Bus Terminal blocks is 5 m and allows a total extension of 155 m. The system uses screened Industrial Ethernet cables with two RJ 45 plugs for the transmission. The cable is supplied ready-made in different lengths or can be made-to-measure for applications with conventional Ethernet tools. Data transfer is based on the interference-free and RS485 industry standard in a double-screened cable.
Operation with up to 64 Bus Terminals to one
Operation with up to 255 Bus Terminals to one Bus Coupler with terminal bus extension
Bus Coupler with KL9010 bus end terminal end terminal KL9020 and coupler terminal KL9050
BECKHOFF New Automation Technology
We reserve the right to make technical changes.
Page 26
Certification: all TwinSAFE devices are subjected to a prototype test according to IEC 61508 and DIN EN ISO 13849-1:2008 PLe.
The TwinSAFE Bus Terminals enable the connection of all common safety sensors and actuators.
The KL2904 Safety Bus Terminal is a digital output terminal with four channels. The terminal switches 24 V DC actuators with up to 0.5 A total current.
The KL6904 TwinSAFE Logic Bus Terminal enables communication with up to 15 TwinSAFE devices. The Bus Terminal features certified safety blocks for functions such as emergency stop, safety door monitoring, etc. In addition, the TwinSAFE Logic Bus Terminal has four safe digital 24 V DC outputs.
The KL1904 digital input terminal for sensors with potential-free contacts for 24 V DC: the Safety Bus Terminal has 4 fail-safe inputs.
TwinSAFE | Safety and I/O technology in one system TwinSAFE – the safety solution from Beckhoff – integrates safety functionalities into the existing control architecture. TwinSAFE from Beckhoff provides a consistent hardware and software technology for achieving integrated and simplified handling, ranging from safe input and output terminals and safe miniature controllers for the Bus Terminal system and the AX5000 Servo Drives to the PCbased Safety PLC.
Input terminal KL1904
Bus Terminal
The following TwinSAFE Bus Terminals are available: – KL1904 | 4-channel digital input – KL2904 | 4-channel digital output – KL6904 | TwinSAFE Logic Bus Terminal with 4 digital outputs
485
For further information on TwinSAFE and the TwinSAFE products see page 828
K1
K3
K1
K2
K2
K4
K3
K4
Output terminal KL2904
Logic Terminal KL6904 TwinSAFE option card
EtherCAT
PROFIBUS
Open control technology for safety integration: the TwinSAFE protocol enables transfer of safety-relevant data via any medium.
We reserve the right to make technical changes.
BECKHOFF New Automation Technology
Page 27
46 mm 18 mm
100 mm
100 mm
100 mm
94 mm 100 mm
15 mm
43 mm
Bus Coupler Housing
47 mm
42 mm
49 mm
44 mm
BKxxxx, BCxxxx
BKxx50, BCxx50
81 mm
21 mm
BXxxxx
LCxxxx
Bus Terminal
Technical data – Bus Coupler housing The Beckhoff Bus Coupler electronics can be mounted in a variety of housings. A housing has three power contacts, which, if the application requires, automatically implement a continued connection, carrying the potential of the power circuit to the next Bus Terminal. The supply voltage that is connected to the Bus Coupler spring-loaded terminals is 24 V DC. If a different voltage is required for the power contacts, the appropriate power feed terminal must be inserted after the Bus Coupler.
486
Mechanical data
BKxxxx, BCxxxx
Design form compact terminal housing with signal LED
BKxx50, BCxx50
Material polycarbonate
Dimensions (W x H x D)
49 mm x 100 mm x 68 mm
44 mm x 100 mm x 68 mm
BXxxxx
LCxxxx
81 mm x 100 mm x 89 mm
21 mm x 100 mm x 68 mm
(BX8000: 61 mm x 100 mm x 89 mm) Installation on 35 mm DIN rail, conforming to EN 50022 with lock
Side by side mounting by double slot and key connection means of Marking standard terminal block marking
Vibration/shock resistance conforms to EN 60068-2-6/EN 60068-2-27/29
EMC immunity/emission conforms to EN 61000-6-2/EN 61000-6-4
Connection
BKxxxx, BCxxxx
Wiring spring-loaded technique
Connection cross-section
0.08…2.5 mm², AWG 28-14, stranded wire, solid wire
Stripping length
8…9 mm
Fieldbus connection depending on fieldbus
Power contacts
3 spring contacts
Current load
IMAX: 10 A (125 A short-circuit)
Nominal voltage
24 V DC
BECKHOFF New Automation Technology
BKxx50, BCxx50 depending on fieldbus
BXxxxx
LCxxxx depending on fieldbus spring-loaded terminals
We reserve the right to make technical changes.
Page 28
100 mm
46 mm 18 mm
46 mm
100 mm
18 mm
100 mm
46 mm
18 mm
18 mm
46 mm
100 mm
100 mm
18 mm
46 mm
Bus Terminal Housing
12 mm
24 mm
12 mm
12 mm
12 mm
KLxxxx
KLxxxx
KSxxxx
KLx80x, KLx81x, KLx889
KL1862, KLx872
The Beckhoff Bus Terminal electronics can be mounted in a variety of housings. Bus Terminals are available with up to three power contacts, and can have a variety of voltages. Care should be taken to ensure that a change in voltage always starts with a power feed terminal.
Mechanical data Design form
KLxxxx
KL5101
KL5102
KSxxxx
KLx80x, KLx81x,
KL1862,
KLx889
KLx872 compact terminal compact terminal compact terminal terminal housing compact terminal compact terminal housing with housing with housing with with pluggable housing with housing with signal LED signal LED signal LED wiring level signal LED signal LED
Material polycarbonate
Dimensions (W x H x D)
12 mm x 100 mm
24 mm x 100 mm
24 mm x 100 mm
12/24 mm x
12 mm x 100 mm
12 mm x 100 mm x 68 mm x 68 mm x 68 mm
100 mm x 71 mm x 68 mm x 68 mm
– standard terminal
Installation on 35 mm DIN rail, conforming to EN 50022 with lock
Side by side mounting by double slot and key connection means of Marking standard terminal standard terminal standard terminal standard terminal block marking block marking block marking block marking
Vibration/shock resistance conforms to EN 60068-2-6/EN 60068-2-27/29
EMC immunity/emission conforms to EN 61000-6-2/EN 61000-6-4
Connection
KLxxxx
KL5101 spring-loaded
KL5102 spring-loaded
KSxxxx block marking
KLx80x, KLx81x,
KL1862,
KLx889
KLx872 spring-loaded direct plug-in flat-ribbon cable connection
Wiring spring-loaded technique technique technique technique technique
Connection cross-section s, st*: 0.08… s, st*: 0.08… s, st*: 0.08… s, st*: 0.08… s*: 0.08…1.5 mm²; common flat-
2.5 mm²,
2.5 mm²,
2.5 mm²,
1.5 mm², st: 0.25…1.5 mm²; ribbon cables,
AWG 28-14
AWG 28-14
AWG 28-14
AWG 28-16 f: 0.14…0.75 mm² AWG 28, spacing
Stripping length
8…9 mm
8…9 mm
8…9 mm
9…10 mm
8…9 mm
–
Power contacts up to 3 blade/ none
2 blade/
2 blade/
2 blade/ none spring contacts spring contacts spring contacts
Current load
IMAX: 10 A (125 A short-circuit)
Nominal voltage depends on Bus Terminal type
1.27 mm spring contacts
*s: solid wire; st: stranded wire; f: ferrule We reserve the right to make technical changes.
BECKHOFF New Automation Technology
Bus Terminal
Technical data – Bus Terminal housing
487
Page 29
46 mm 18 mm
100 mm
100 mm
18 mm
46 mm
KM Housing
24 mm
51 mm
73 mm
35 mm
26.5 mm
71 mm
75 mm
55 mm
KM10x4, KM20x4
KM10x2, KM20x2
Bus Terminal
Technical data – Terminal module housing The Beckhoff terminal modules with pluggable connection level are mounted in enclosures of different size. Like for the HD Bus Terminals, spring-loaded terminals are used and no tools are required for the wiring.
488
Mechanical data
KMx0x2
Design form compact terminal module with pluggable wiring level
Dimensions (W x H x D)
26.5 mm x 100 mm x 71 mm
Installation on 35 mm DIN rail, conforming to EN 50022 with lock
Side by side mounting by double slot and key connection means of Vibration/shock resistance conforms to EN 60068-2-6/EN 60068-2-27/29
EMC immunity/emission conforms to EN 61000-6-2/EN 61000-6-4
Connection
KMx0x2, KMx0x4
Wiring spring-loaded technique
Connection cross-section
0.08…1.5 mm², stranded wire, solid wire
Stripping length
8 mm
Power contacts none
Nominal voltage depends on Bus Terminal type, max. 60 V DC
BECKHOFF New Automation Technology
KMx0x4 75 mm x 100 mm x 55 mm
We reserve the right to make technical changes.
Page 30
46 mm 18 mm
100 mm
KM Housing
121 mm
35 mm
123 mm
55 mm
Bus Terminal
KM10x8, KM20x8
489
Mechanical data
KMx0x8
Design form compact terminal module with pluggable wiring level
Dimensions (W x H x D)
123 mm x 100 mm x 55 mm
Installation on 35 mm DIN rail, conforming to EN 50022 with lock
Side by side mounting by double slot and key connection means of Vibration/shock resistance conforms to EN 60068-2-6/EN 60068-2-27/29
EMC immunity/emission conforms to EN 61000-6-2/EN 61000-6-4
Connection
KMx0x8
Wiring spring-loaded technique
Connection cross-section
0.08…1.5 mm², stranded wire, solid wire
Stripping length
8 mm
Power contacts none
Nominal voltage depends on Bus Terminal type, max. 60 V DC