Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact

The text of a spec sheet · part 16 of 25

Modular electrical terminal CPX, pages 151 to 160

Pages 151 to 160 of 246

The original document is the PDF (8.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

Filed in the catalog under the Festo CPX-EPL-EV

Page 151

Measuring modules CPX-CMIX Accessories Ordering data Brief description

Part No.

Type

Order code in the CPX configurator: T23

567417

CPX-CMIX-M1-1

0.25 m 0.5 m 2m 5m 8m 2m 5m 8m

540327 540328 540329 540330 540331 540332 540333 540334 543252

KVI-CP-3-WS-WD-0,25 KVI-CP-3-WS-WD-0,5 KVI-CP-3-WS-WD-2 KVI-CP-3-WS-WD-5 KVI-CP-3-WS-WD-8 KVI-CP-3-GS-GD-2 KVI-CP-3-GS-GD-5 KVI-CP-3-GS-GD-8 KVI-CP-3-SSD

2m

575898

NEBP-M16W6-K-2-M9W5

550219

CPX-M-M3X22-4X

Measuring module

Connecting cables Connecting cable with angled plug and angled socket

Connecting cable with straight plug and straight socket

Connector for control cabinet through-feed

For displacement encoder MME Connection between displacement encoder MME and measuring module CPX-CMIX

Screws For mounting on the metal interlinking block

Inscription labels Inscription labels 6x10, in frames

64 pieces

18576

IBS-6X10

Measuring module description CPX-CMIX1)

German English Spanish French Italian

567053 567054 567055 567056 567057

P.BE-CPX-CMIX-DE P.BE-CPX-CMIX-EN P.BE-CPX-CMIX-ES P.BE-CPX-CMIX-FR P.BE-CPX-CMIX-IT

User manual

1)

User manual in paper form is not included in the scope of delivery.

2018/04 – Subject to change

è Internet: www.festo.com/catalogue/...

151

Page 152

Terminal CPX Technical data – Input module, digital Function Digital input modules enable the connection of two-wire and three-wire sensors (proximity sensors, inductive or capacitive sensors, etc). Depending on the connection block selected, the module supports various connection concepts with different numbers of sockets (single or double allocation).

Applications Input modules for 24 V DC sensor supply voltage PNP or NPN logic Supports connection blocks with M12, M8, Sub-D, Harax and terminal connection Module features can be parameterised The input module receives the volt­ age supply for the electronics and the sensors from the interlinking block Module protection and diagnostics through integrated electronic fuse protection

General technical data Type

CPX-4DE

No. of inputs Max. residual current of inputs per module Fuse protection

Intrinsic current consumption at operating voltage Operating voltage Nominal value Permissible range Electrical isolation Channel – channel Channel – internal bus Switching level Signal 0 Signal 1 Input debounce time Input characteristic curve Switching logic LED displays

[A]

[mA] [V DC] [V DC]

[V DC] [V DC] [ms]

Group diagnostics Channel diagnostics Channel status

Diagnostics Parameterisation

Protection class to EN 60529 Temperature range

Operation Storage/transport

Materials Grid dimension Dimensions (incl. interlinking block and connection block) W x L x H Weight

152

[°C] [°C] [mm] [mm] [g]

è Internet: www.festo.com/catalogue/...

CPX-8DE-D

CPX-8NDE

4 8 0.7 1 Internal elec­ Internal elec­ tronic fuse for tronic fuse for each module each module Typically 15 24 18 … 30 No No 5 11 3 (0.1, 10, 20 parameterisable) IEC 1131 Part 2 Positive logic (PNP)

CPX-8DE

8 0.7 Internal elec­ tronic fuse for each channel

8 0.7 Internal elec­ tronic fuse for each module

1 1 – – 4 8 Short circuit/overload per channel Module monitoring Behaviour after short circuit Input debounce time Signal stretching time Depending on connection block –5 … +50 –20 … +70 Reinforced PA, PC 50 50 x 107 x 50 38

1 8 8

11 5

Negative logic (NPN) 1 – 8

Subject to change – 2018/04

Page 153

Terminal CPX Technical data – Input module, digital Connection and display components CPX-4DE

CPX-8DE

2

CPX-8NDE

2

1 1 Status LEDs (green)

CPX-8DE-D

1

1

2 Error LED (red, module error)

Connection block/digital input module combinations Connection blocks Part No. CPX-AB-8-M8-3POL CPX-AB-4-M12X2-5POL CPX-AB-4-M12X2-5POL-R CPX-AB-8-KL-4POL CPX-AB-1-SUB-BU-25POL CPX-AB-4-HAR-4POL CPX-M-AB-4-M12x2-5POL

195706 195704 541254 195708 525676 525636 549367

Pin allocation Connection block inputs

CPX-4DE

2

2

1

3

3 Channel-specific error LEDs (red)

Digital input modules CPX-4DE CPX-8DE n n n n n n n n n n n n n n

Allocation to inputs è Pin allocation for module

CPX-8DE-D

CPX-8NDE n n n n n n n n n n n n n n

CPX-8DE, CPX-8DE-D and CPX-8NDE

CPX-AB-8-M8-3POL X1.1: 24 VSEN X1.3: 0 VSEN X1.4: Input x

X5.1: 24 VSEN X5.3: 0 VSEN X5.4: Input x+2

X1.1: 24 VSEN x X1.3: 0 VSEN x X1.4: Input x

X5.1: 24 VSEN x+4 X5.3: 0 VSEN x+4 X5.4: Input x+4

X2.1: 24 VSEN X2.3: 0 VSEN X2.4: Input x+1

X6.1: 24 VSEN X6.3: 0 VSEN X6.4: Input x+3

X2.1: 24 VSEN x+1 X2.3: 0 VSEN x+1 X2.4: Input x+1

X6.1: 24 VSEN x+5 X6.3: 0 VSEN x+5 X6.4: Input x+5

X3.1: 24 VSEN X3.3: 0 VSEN X3.4: Input x+1

X7.1: 24 VSEN X7.3: 0 VSEN X7.4: Input x+3

X3.1: 24 VSEN x+2 X3.3: 0 VSEN x+2 X3.4: Input x+2

X7.1: 24 VSEN x+6 X7.3: 0 VSEN x+6 X7.4: Input x+6

X4.1: 24 VSEN X4.3: 0 VSEN X4.4: n.c.

X8.1: 24 VSEN X8.3: 0 VSEN X8.4: n.c.

X4.1: 24 VSEN x+3 X4.3: 0 VSEN x+3 X4.4: Input x+3

X8.1: 24 VSEN x+7 X8.3: 0 VSEN x+7 X8.4: Input x+7

CPX-AB-4-M12X2-5POL, CPX-AB-4-M12X2-5POL-R1) and CPX-M-AB-4-M12X2-5POL X1.1: 24 VSEN X3.1: 24 VSEN X1.2: Input x+1 X3.2: Input x+3 X1.3: 0 VSEN X3.3: 0 VSEN X1.4: Input x X3.4: Input x+2 X1.5: FE X3.5: FE

X1.1: X1.2: X1.3: X1.4: X1.5:

24 VSEN x Input x+1 0 VSEN x Input x FE

X3.1: X3.2: X3.3: X3.4: X3.5:

24 VSEN x+4 Input x+5 0 VSEN x+4 Input x+4 FE

X2.1: X2.2: X2.3: X2.4: X2.5:

X2.1: X2.2: X2.3: X2.4: X2.5:

24 VSEN x+2 Input x+3 0 VSENx+2 Input x+2 FE

X4.1: X4.2: X4.3: X4.4: X4.5:

24 VSEN x+6 Input x+7 0 VSEN x+6 Input x+6 FE

1)

24 VSEN n.c. 0 VSEN Input x+1 FE

X4.1: X4.2: X4.3: X4.4: X4.5:

24 VSEN n.c. 0 VSEN Input x+3 FE

Speedcon quick lock, screening additionally on metal thread

2018/04 – Subject to change

è Internet: www.festo.com/catalogue/...

153

Page 154

Terminal CPX Technical data – Input module, digital Pin allocation Connection block inputs

CPX-4DE

CPX-8DE, CPX-8DE-D and CPX-8NDE

CPX-AB-8-KL-4POL X1.0: X1.1: X1.2: X1.3:

24 VSEN 0 VSEN Input x FE

X5.0: X5.1: X5.2: X5.3:

24 VSEN 0 VSEN Input x+2 FE

X1.0: X1.1: X1.2: X1.3:

24 VSEN x 0 VSEN x Input x FE

X5.0: X5.1: X5.2: X5.3:

24 VSEN x+4 0 VSEN x+4 Input x+4 FE

X2.0: X2.1: X2.2: X2.3:

24 VSEN 0 VSEN Input x+1 FE

X6.0: X6.1: X6.2: X6.3:

24 VSEN 0 VSEN Input x+3 FE

X2.0: X2.1: X2.2: X2.3:

24 VSEN x+1 0 VSEN x+1 Input x+1 FE

X6.0: X6.1: X6.2: X6.3:

24 VSEN x+5 0 VSEN x+5 Input x+5 FE

X3.0: X3.1: X3.2: X3.3:

24 VSEN 0 VSEN Input x+1 FE

X7.0: X7.1: X7.2: X7.3:

24 VSEN 0 VSEN Input x+3 FE

X3.0: X3.1: X3.2: X3.3:

24 VSEN x+2 0 VSEN x+2 Input x+2 FE

X7.0: X7.1: X7.2: X7.3:

24 VSEN x+6 0 VSEN x+6 Input x+6 FE

X4.0: X4.1: X4.2: X4.3:

24 VSEN 0 VSEN n.c. FE

X8.0: X8.1: X8.2: X8.3:

24 VSEN 0 VSEN n.c. FE

X4.0: X4.1: X4.2: X4.3:

24 VSEN x+3 0 VSEN x+3 Input x+3 FE

X8.0: X8.1: X8.2: X8.3:

24 VSEN x+7 0 VSEN x+7 Input x+7 FE

1: 2: 3: 4: 5: 6: 7: 8: 9: 10: 11: 12: 13:

Input x Input x+1 Input x+1 n.c. 24 VSEN 0 VSEN 24 VSEN 0 VSEN 24 VSEN 24 VSEN 0 VSEN 0 VSEN FE

14: Input x+2 15: Input x+3 16: Input x+3 17: n.c. 18: 24 VSEN 19: 24 VSEN 20: 24 VSEN 21: 24 VSEN 22: 0 VSEN 23: 0 VSEN 24: 0 VSEN 25: FE Housing: FE

1: 2: 3: 4: 5: 6: 7: 8: 9: 10: 11: 12: 13:

Input x Input x+1 Input x+2 Input x+3 24 VSEN x+1 0 VSEN x+1 24 VSEN x+3 0 VSEN x+3 24 VSEN x 24 VSEN x+2 0 VSEN x 0 VSEN x+2 FE

14: Input x+4 15: Input x+5 16: Input x+6 17: Input x+7 18: 24 VSEN x+4 19: 24 VSEN x+5 20: 24 VSEN x+6 21: 24 VSEN x+7 22: 0 VSEN x+2 and 3 23: 0 VSEN x+2 and 3 24: 0 VSEN x+2 and 3 25: FE Housing: FE

X1.1: X1.2: X1.3: X1.4:

24 VSEN Input x+1 0 VSEN Input x

X3.1: X3.2: X3.3: X3.4:

24 VSEN Input x+3 0 VSEN Input x+2

X1.1: X1.2: X1.3: X1.4:

24 VSEN x Input x+1 0 VSEN x Input x

X3.1: X3.2: X3.3: X3.4:

24 VSEN x+4 Input x+5 0 VSEN x+4 Input x+4

X2.1: X2.2: X2.3: X2.4:

24 VSEN n.c. 0 VSEN Input x+1

X4.1: X4.2: X4.3: X4.4:

24 VSEN n.c. 0 VSEN Input x+3

X2.1: X2.2: X2.3: X2.4:

24 VSEN x+2 Input x+3 0 VSEN x+2 Input x+2

X4.1: X4.2: X4.3: X4.4:

24 VSEN x+6 Input x+7 0 VSEN x+6 Input x+6

CPX-AB-1-SUB-BU-25POL

CPX-AB-4-HAR-4POL

154

è Internet: www.festo.com/catalogue/...

Subject to change – 2018/04

Page 155

Terminal CPX Accessories – Input module, digital Ordering data Designation

Part No.

Type

4 digital inputs, positive logic (PNP)

195752

CPX-4DE

8 digital inputs, positive logic (PNP)

195750

CPX-8DE

8 digital inputs, positive logic (PNP), advanced diagnostic function

541480

CPX-8DE-D

8 digital inputs, negative logic (NPN)

543813

CPX-8NDE

Plastic

195706 195704 541254 195708 525676 525636 549367

CPX-AB-8-M8-3POL CPX-AB-4-M12X2-5POL CPX-AB-4-M12X2-5POL-R CPX-AB-8-KL-4POL CPX-AB-1-SUB-BU-25POL CPX-AB-4-HAR-4POL CPX-M-AB-4-M12X2-5POL

Modular system for sensor/actuator distributor

–

NEDY-… è Internet: nedy

Plug M12, 4-pin

2x socket M8, 3-pin

8005311

NEDY-L2R1-V1-M8G3-N-M12G4

2x socket M12, 5-pin

8005310

NEDY-L2R1-V1-M12G5-N-M12G4

HARAX plug, 4-pin

18696 192009 18666 192008 18778 18779 192010 175487 525928

SEA-GS-M8 SEA-3GS-M8-S SEA-GS-7 SEA-4GS-7-2,5 SEA-GS-9 SEA-GS-11-DUO SEA-5GS-11-DUO SEA-M12-5GS-PG7 SEA-GS-HAR-4POL

Sub-D plug, 25-pin

527522

SD-SUB-D-ST25

541346 541347 541348 541349 –

NEBU-M8G3-K-0.5-M8G3 NEBU-M8G3-K-1-M8G3 NEBU-M8G3-K-2.5-M8G3 NEBU-M8G3-K-5-M8G3 NEBU-… è Internet: nebu

Input module, digital

Connection block

Metal

8x socket, M8, 3-pin 4x socket, M12, 5-pin 4x socket, M12 with quick-lock technology, 5-pin Spring clip terminal, 32-pin 1x Sub-D socket, 25-pin 4x socket, quick connection, 4-pin 4x socket, M12, 5-pin

Distributor

Plug Plug

M8, 3-pin solderable screw-in

M12, 4-pin, PG7 M12, PG7, 4-pin for cable 2.5 mm M12, 4-pin, PG9 M12, 4 pin for 2 cables M12 for 2 cables, 5-pin M12, 5-pin

Connecting cable Connecting cable M8-M8

Modular system for connecting cables

2018/04 – Subject to change

0.5 m 1.0 m 2.5 m 5.0 m

è Internet: www.festo.com/catalogue/...

155

Page 156

Terminal CPX Accessories – Input module, digital Ordering data Designation

Part No.

Type

Cover for CPX-AB-8-KL-4POL (IP65, IP67) – 8 cable through-feeds M9 – 1 cable through-feed for multi-pin plug

538219

AK-8KL

Fittings kit

538220

VG-K-M9

Screening plate for M12 connections

526184

CPX-AB-S-4-M12

526439 526440 526441 526442 526443

P.BE-CPX-EA-DE P.BE-CPX-EA-EN P.BE-CPX-EA-ES P.BE-CPX-EA-FR P.BE-CPX-EA-IT

Cover

Screening plate

User manual User manual

156

German English Spanish French Italian

è Internet: www.festo.com/catalogue/...

Subject to change – 2018/04

Page 157

Terminal CPX Technical data – PROFIsafe input module Function The PROFIsafe input module has 8 in­ put channels whose signal status is detected for safety-reasons, with the information transmitted to a suitable safety controller using the PROFIsafe safety protocol in combination with the appropriate fieldbus (PROFINET or PROFIBUS). This function is exclus­ ively available for safety controllers using the PROFIsafe protocol, profile version 2.4.

Scope of application Input module for 24 V DC sensor supply voltage Supports connection blocks with M12 and terminal connection Module features can be parameterised Input module receives the voltage supply for the electronics and the sensors from the interlinking block Module protection and diagnostics through integrated electronic fuse protection

Description Module-based passivation While channel-by-channel passivation is disabled, the input module, in accordance with PROFIsafe specification, switches all information

Channel-by-channel passivation in the input image to the safe status, even when there is only one channel error.

In the case of channel-by-channel passivation, when a channel error occurs, the input module switches the input information of the affected channel pair to 0, depending on the function mode.

The input information for unaffected channel pairs does not change. The input module remains integrated. The input module indicates the current channel error status to the control unit via the input image.

The function mode has an influence on the evaluation of the input signals, and optionally on the generation of clock signals.

There are five independent clock out­ puts available for safe operation of passive sensors; the pulse patterns are used in some operating modes to detect crossovers in the signal paths.

The input module is designed to en­ sure that the input channels provide either secure data or no data at all, even when a fault is present in the system.

Use of multi-channel sensor applic­ ations with up to 8 secure inputs, which can be grouped and are suit­ able for configuration with the help of 11 different function modes

Connection of different switches and sensors within the safety chain Output of an identifier coded by DIL switch in the connection block CPX-AB-ID-P

-H- Note

Operating mode selector switch with four positions Rotary indexing table

Light curtain Acknowledge button with request

End-position switches Protective door with two NO switches

Applications The inputs on the PROFIsafe input module can be combined for multichannel sensor applications. Every two inputs form a channel pair, which is set separately with one of 11 function modes. Range of applications Use as an input module for a higher-order safety controller. Several input modules can be used together and these monitor mutually independent sensors

The safety integrity level, Perform­ ance Level and category for the sys­ tem as a whole correspond to that of the component in the safety chain with the lowest characteristic value.

Application examples Two-hand circuit for starting a function Emergency stop switch for incidents

2018/04 – Subject to change

è Internet: www.festo.com/catalogue/...

157

Page 158

Terminal CPX Technical data – PROFIsafe input module General technical data Type Number of inputs Safety function Max. address capacity Max. cable length Max. power supply Current consumption of module Operating voltage Voltage drop per channel Residual ripple Electrical isolation Input characteristic Switching logic Safety integrity level Performance Level Failure rate per hour (PFH) Certificate issuing authority LED displays

CPX-F8DE-P

Inputs Outputs Per module Nominal value Permissible range

[byte] [byte] [m] [A] [mA] [V DC] [V DC] [V] [Vss]

Channel – channel Inputs As per EN62061 As per EN61508 As per ISO13849

Group diagnostics Channel diagnostics Channel status Failsafe protocol active

Diagnostics

Control elements Degree of protection to EN 60529 Grid dimension Dimensions (incl. interlinking block and connection block) W x L x H

158

[mm] [mm]

è Internet: www.festo.com/catalogue/...

8 Reliable detection and evaluation of input statuses 6 7 200 3 Typ. 35 (power supply for electronics) 24 20.4 … 28.8 0.6 2 within voltage range No To IEC 61131-2, type 2 PNP (positive switching) Reliable detection and evaluation of input statuses up to SIL CL3 Reliable detection and evaluation of input statuses up to SIL3 Reliable detection and evaluation of input statuses up to Cat 4 and PL e 1.0x 10-9 01/205/5444.00/15 1 8 8 1 Short circuit per channel Undervoltage Overvoltage Excessive temperature Crossover per channel Wire break per channel Communication Process data error Self test DIL switches Depending on connection block 50 50 x 107 x 55

Subject to change – 2018/04

Page 159

Terminal CPX Technical data – PROFIsafe input module Materials Note on materials

RoHS compliant

Operating and environmental conditions Ambient temperature Storage temperature CE marking (see declaration of conformity) Approval certificate

[°C] [°C]

–5 … +50 –20 … +70 To EC Machinery Directive c UL us Recognised (OL)

Connection and display components CPX-F8DE-P 4

1

2

1 Channel-related status LEDs (green): 2 Channel-related error LEDs (red)

3 Fail-safe protocol active (green) 4 Error LED (red, module error)

3

Combinations of bus nodes/control blocks with PROFIsafe input module Bus node/control block Part No. CPX-FB13 CPX-FB33 CPX-M-FB34 CPX-M-FB35

195740 548755 548751 548749

PROFIsafe input module CPX-F8DE-P n n n n

-H- Note The PROFIsafe input module CPX-F8DE-P can only be interfaced as of software release 21 or re­ lease 30 (in the case of CPX-FB13).

2018/04 – Subject to change

è Internet: www.festo.com/catalogue/...

159

Page 160

Terminal CPX Technical data – PROFIsafe input module Connection block/PROFIsafe input module combinations Connection blocks Part No.

PROFIsafe input module CPX-F8DE-P n n n n

CPX-M-AB-4-M12X2-5POL CPX-M-AB-4-M12X2-5POL-T CPX-AB-8-KL-4POL CPX-AB-ID-P

549367 2639560 195708 2639571

Pin allocation Connection block inputs

CPX-F8DE-P

CPX-M-AB-4-M12X2-5POL X1.1: X1.2: X1.3: X1.4: X1.5:

24 VSEN Input x+1 0 VSEN Input x FE

X3.1: X3.2: X3.3: X3.4: X3.5:

24 VSEN Input x+5 0 VSEN Input x+4 FE

X2.1: X2.2: X2.3: X2.4: X2.5:

24 VSEN Input x+3 0 VSEN Input x+2 FE

X4.1: X4.2: X4.3: X4.4: X4.5:

24 VSEN Input x+7 0 VSEN Input x+6 FE

CPX-M-AB-4-M12X2-5POL-T X1-T.1: X1-T.2: X1-T.3: X1-T.4: X1-T.5:

24 VSEN x Input x+1 0 VSEN Input x 24 VSEN x+1

X3-T.1: X3-T.2: X3-T.3: X3-T.4: X3-T.5:

24 VSEN x+4 Input x+5 0 VSEN Input x+4 24 VSEN x+5

X2-T.1: X2-T.2: X2-T.3: X2-T.4: X2-T.5:

24 VSEN x+2 Input x+3 0 VSEN Input x+2 24 VSEN x+3

X4-T.1: X4-T.2: X4-T.3: X4-T.4: X4-T.5:

24 VSEN x+6 Input x+7 0 VSEN Input x+6 24 VSEN x+7

CPX-AB-8-KL-4POL

160

X1.0: X1.1: X1.2: X1.3:

24 VSEN 0 VSEN Input x FE

X5.0: X5.1: X5.2: X5.3:

24 VSEN 0 VSEN Input x+4 FE

X2.0: X2.1: X2.2: X2.3:

24 VSEN x 24 VSEN x+1 Input x+1 FE

X6.0: X6.1: X6.2: X6.3:

24 VSEN x+4 24 VSEN x+5 Input x+5 FE

X3.0: X3.1: X3.2: X3.3:

24 VSEN 0 VSEN Input x+2 FE

X7.0: X7.1: X7.2: X7.3:

24 VSEN 0 VSEN Input x+6 FE

X4.0: X4.1: X4.2: X4.3:

24 VSEN x+2 24 VSEN x+3 Input x+3 FE

X8.0: X8.1: X8.2: X8.3:

24 VSEN x+6 24 VSEN x+7 Input x+7 FE

è Internet: www.festo.com/catalogue/...

Subject to change – 2018/04