Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact

The text of a spec sheet · part 15 of 25

Modular electrical terminal CPX, pages 141 to 150

Pages 141 to 150 of 246

The original document is the PDF (8.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

Filed in the catalog under the Festo CPX-EPL-EV

Page 141

Control block CPX-CM-HPP Technical data Connection and display components

1

2

1 2 3 4

3

3-digit display Control interface LED display, product-specific Inscription labels

4

Pin allocation – Control interface Pin

Signal

Meaning

1 2 3 4 5 Housing n.c. n.c. CAN_GND CAN_H CAN_L Screened

Not connected Not connected CAN ground CAN high CAN low Cable screen must be connected to functional earth (FE)

Socket M9, 5-pin

Permitted bus nodes/CEC Bus node/CEC

Protocol

Max. no. of CPX-CM-HPP modules

CPX-CEC… CPX-FB6 CPX-FB11 CPX-FB13 CPX-FB14 CPX-M-FB21 CPX-FB23-24

– INTERBUS DeviceNet PROFIBUS CANopen INTERBUS CC-Link

CPX-FB33 CPX-M-FB34 CPX-M-FB35 CPX-FB36 CPX-FB37 CPX-FB38 CPX-FB39 CPX-FB40 CPX-M-FB41

PROFINET RT, M12 PROFINET RT, RJ45 PROFINET RT, SCRJ EtherNet/IP EtherCAT EtherCAT Sercos III POWERLINK PROFINET RT

0 0 2 2 1 0 1 (function module F23) 0 (function module F24) 2 2 2 2 2 2 2 2 2

2018/04 – Subject to change

è Internet: www.festo.com/catalogue/...

141

Page 142

Control block CPX-CM-HPP Accessories Ordering data Designation

Part No.

Type

562214

CPX-CM-HPP

Part No.

Type

2m

563711

NEBC-M9W5-K-2-N-LE3

5m

Control block Max. 4 individual electric axes can be controlled via CAN bus

Ordering data – Bus connection Designation Connecting cable Connecting cable

563712

NEBC-M9W5-K-5-N-LE3

Plug for CAN bus interface, Sub-D, 9-pin, without terminating resistor

533783

FBS-SUB-9-WS-CO-K

Inscription label holder for manifold block

536593

CPX-ST-1

German

568683

CPX-CM-HPP-DE

English

568684

CPX-CM-HPP-EN

Inscription label

Documentation Manual – Control block CPX-CM-HPP

142

è Internet: www.festo.com/catalogue/...

Subject to change – 2018/04

Page 143

Axis controllers CPX-CMAX Technical data The axis controller CPX-CMAX is intended exclusively for valve terminals CPX.

General technical data Operating voltage Operating voltage range Nominal operating voltage Current consumption at nominal operating voltage Fuse protection (short circuit) Power failure bridging Load voltage Load voltage range Nominal load voltage Perm. load current Fuse protection (short circuit) Number of axis strings Axes per string Length of connecting cable to axis Max. no. of modules Display Assigned addresses

[V DC] [V DC] [mA] [ms]

[V DC] [V DC] [A]

[m]

Outputs Inputs

[bit] [bit]

Operating modes Controller types Diagnostics Status display

Control interface Data

2018/04 – Subject to change

20 … 30 24 2.5 Electronic 1 1 30 7 7-segment display 8x8 8x8 Record Select mode Direct mode Position control Force control Module-orientated Via local 7-segment display Module status Power Load Display/Error Axis X MC Axis X

CAN bus with Festo protocol Digital 5-pin M9 Socket

Electrical connection

Materials: Housing Note on materials Product weight Dimensions

18 … 30 24 200 Electronic 10

Length Width Height

[g] [mm] [mm] [mm]

Reinforced PA RoHS-compliant 140 107 50 55

è Internet: www.festo.com/catalogue/...

143

Page 144

Axis controllers CPX-CMAX Technical data Operating and environmental conditions Ambient temperature Relative air humidity Protection class to IEC 60529

[°C] [%]

–5 … +50 5 … 95, non-condensing IP65

Connection and display components

1

2

3

4

1 2 3 4

3-digit display Control interface Status LEDs Inscription labels

Pin allocation – Control interface Pin

Signal

Designation

1 2 3 4 5 Housing

+24 V +24 V 0V CAN_H CAN_L Screened

Nominal operating voltage Load voltage Ground CAN high CAN low Cable screening

Permitted bus nodes/CEC Bus node/CEC

Protocol

Max. no. of CMAX modules

CPX-CEC… CPX-FB6 CPX-FB11 CPX-FB13 CPX-FB14 CPX-M-FB21 CPX-FB23-24

– INTERBUS DeviceNet1) PROFIBUS2) CANopen INTERBUS CC-Link

CPX-FB33 CPX-M-FB34 CPX-M-FB35 CPX-FB36 CPX-FB37 CPX-FB38 CPX-FB39 CPX-FB40 CPX-M-FB41

PROFINET RT, M12 PROFINET RT, RJ45 PROFINET RT, SCRJ EtherNet/IP EtherCAT EtherCAT Sercos III POWERLINK PROFINET RT

8 1 8 8 4 1 4 (function module F23) 8 (function module F24) 8 8 8 8 8 8 8 8 8

1) 2)

With Revision 20 (R20) With Revision 23 (R23)

PROFIBUS®, DeviceNet®, CANopen®, INTERBUS®, CC-LINK®, EtherCAT®, PROFINET®, Sercos®, EtherNet/IP® is a registered trademark of its respective trademark holder in certain countries.

144

è Internet: www.festo.com/catalogue/...

Subject to change – 2018/04

Page 145

Axis controllers CPX-CMAX Accessories Ordering data Brief description

Part No.

Type

Order code in the CPX configurator: T21

548932

CPX-CMAX-C1-1

Connector for control cabinet through-feed

540327 540328 540329 540330 540331 540332 540333 540334 543252

KVI-CP-3-WS-WD-0,25 KVI-CP-3-WS-WD-0,5 KVI-CP-3-WS-WD-2 KVI-CP-3-WS-WD-5 KVI-CP-3-WS-WD-8 KVI-CP-3-GS-GD-2 KVI-CP-3-GS-GD-5 KVI-CP-3-GS-GD-8 KVI-CP-3-SSD

For mounting on the metal interlinking block

550219

CPX-M-M3X22-4X

Axis controller

Connecting cables Connecting cable with angled plug and angled socket

Connecting cable with straight plug and straight socket

0.25 m 0.5 m 2m 5m 8m 2m 5m 8m

Screws

Inscription labels Inscription labels 6x10, in frames

64 pieces

18576

IBS-6X10

Axis controller description CPX-CMAX1)

German English Spanish French Italian

559750 559751 559752 559753 559754

P.BE-CPX-CMAX-SYS-DE P.BE-CPX-CMAX-SYS-EN P.BE-CPX-CMAX-SYS-ES P.BE-CPX-CMAX-SYS-FR P.BE-CPX-CMAX-SYS-IT

User manual

1)

User manual in paper form is not included in the scope of delivery.

2018/04 – Subject to change

è Internet: www.festo.com/catalogue/...

145

Page 146

End-position controllers CPX-CMPX Technical data The end-position controller CPX-CMPX is intended exclusively for use in valve terminals CPX.

General technical data Operating voltage Operating voltage range Nominal operating voltage Current consumption at nominal operating voltage

[V DC] [V DC] [mA]

18 … 30 24 80

Load voltage Load voltage range Nominal load voltage Perm. load current

[V DC] [V DC] [A]

20 … 30 24 2.5

Number of axes per module Length of connecting cable to axis Max. no. of modules Display Control elements Assigned addresses

[m]

Outputs Inputs

[bit] [bit]

Diagnostics

Status display

Control interface Data

CAN bus with Festo protocol Digital 5-pin M9 Socket

Electrical connection

Materials: Housing Product weight Dimensions

146

1 30 9 7-segment display 3 keys 6x8 6x8 Module-orientated Via local 7-segment display Via operator unit CPX-MMI-1 Module status Power Load

Length Width Height

[g] [mm] [mm] [mm]

Reinforced PA 240 107 50 55

è Internet: www.festo.com/catalogue/...

Subject to change – 2018/04

Page 147

End-position controllers CPX-CMPX Technical data Operating and environmental conditions Ambient temperature Relative air humidity Protection class to IEC 60529 CE mark (see declaration of conformity)

[°C] [%]

–5 … +50 5 … 95, non-condensing IP65 To EU EMC Directive

Connection and display components

1

3

4

2

1 2 3 4 5

5

3-digit display Control interface Status LEDs Operating buttons Inscription labels

Pin allocation – Control interface Pin

Signal

Designation

1 2 3 4 5 Housing

+24 V +24 V 0V CAN_H CAN_L Screened

Nominal operating voltage Load voltage Ground CAN high CAN low Cable screening

Permitted bus nodes/CEC Bus node/CEC

Protocol

Max. no. of CMPX modules

CPX-CEC… CPX-FB6 CPX-FB11 CPX-FB13 CPX-FB14 CPX-M-FB21 CPX-FB23-24

– INTERBUS DeviceNet1) PROFIBUS2) CANopen INTERBUS CC-Link

CPX-FB33 CPX-M-FB34 CPX-M-FB35 CPX-FB36 CPX-FB37 CPX-FB38 CPX-FB39 CPX-FB40 CPX-M-FB41

PROFINET RT, M12 PROFINET RT, RJ45 PROFINET RT, SCRJ EtherNet/IP EtherCAT EtherCAT Sercos III POWERLINK PROFINET RT

9 2 9 9 5 2 5 (function module F23) 9 (function module F24) 9 9 9 9 9 9 9 9 9

1) 2)

With Revision 20 (R20) With Revision 23 (R23)

PROFIBUS®, DeviceNet®, CANopen®, INTERBUS®, CC-LINK®, EtherCAT®, PROFINET®, Sercos®, EtherNet/IP® is a registered trademark of its respective trademark holder in certain countries. 2018/04 – Subject to change

è Internet: www.festo.com/catalogue/...

147

Page 148

End-position controllers CPX-CMPX Accessories Ordering data Brief description

Part No.

Type

Order code in the CPX configurator: T20

548931

CPX-CMPX-C-1-H1

Connector for control cabinet through-feed

540327 540328 540329 540330 540331 540332 540333 540334 543252

KVI-CP-3-WS-WD-0,25 KVI-CP-3-WS-WD-0,5 KVI-CP-3-WS-WD-2 KVI-CP-3-WS-WD-5 KVI-CP-3-WS-WD-8 KVI-CP-3-GS-GD-2 KVI-CP-3-GS-GD-5 KVI-CP-3-GS-GD-8 KVI-CP-3-SSD

For mounting on the metal interlinking block

550219

CPX-M-M3X22-4X

End-position controller

Connecting cables Connecting cable with angled plug and angled socket

Connecting cable with straight plug and straight socket

0.25 m 0.5 m 2m 5m 8m 2m 5m 8m

Screws

Inscription labels Inscription labels 6x10, in frames

64 pieces

18576

IBS-6X10

End-position controller description CPX-CMPX1)

German English Spanish French Italian

555479 555480 555481 555482 555483

P.BE-CPX-CMPX-SYS-DE P.BE-CPX-CMPX-SYS-EN P.BE-CPX-CMPX-SYS-ES P.BE-CPX-CMPX-SYS-FR P.BE-CPX-CMPX-SYS-IT

User manual

1)

User manual in paper form is not included in the scope of delivery.

148

è Internet: www.festo.com/catalogue/...

Subject to change – 2018/04

Page 149

Measuring modules CPX-CMIX Technical data The measuring module CPX-CMIX is intended exclusively for use in valve terminals CPX.

General technical data Operating voltage Operating voltage range Nominal operating voltage Current consumption at nominal operating voltage Protection against short circuit Power failure bridging No. of axis strings Axes per string Length of connecting cable to axis Max. no. of modules Display Assigned addresses

[V DC] [V DC] [mA] [ms]

[m]

Outputs Inputs

[bit] [bit]

Diagnostics

Status display

Control interface Data

2018/04 – Subject to change

1 1 30 9 7-segment display 6x8 6x8 Channel and module-oriented Via local 7-segment display Undervoltage of modules Undervoltage of measuring system Power Load Error

CAN bus with Festo protocol Digital 5-pin M9 Socket

Electrical connection

Materials: Housing Note on materials Product weight Dimensions

18 … 30 24 80 Yes 10

Length Width Height

[g] [mm] [mm] [mm]

Reinforced PA RoHS-compliant 140 107 50 55

è Internet: www.festo.com/catalogue/...

149

Page 150

Measuring modules CPX-CMIX Technical data Operating and environmental conditions Ambient temperature Relative air humidity Protection class to IEC 60529

[°C] [%]

–5 … +50 5 … 95, non-condensing IP65

Connection and display components

1

2

3

4

1 2 3 4

3-digit display Control interface Status LEDs Inscription labels

Pin allocation – Control interface Pin

Signal

Designation

1 2 3 4 5 Housing

+24 V +24 V 0V CAN_H CAN_L Screened

Nominal operating voltage Load voltage Ground CAN high CAN low Cable screening

Permitted bus nodes/CEC Bus node/CEC

Protocol

Max. no. of CMIX modules

CPX-CEC… CPX-FB6 CPX-FB11 CPX-FB13 CPX-FB14 CPX-M-FB21 CPX-FB23-24

– INTERBUS DeviceNet1) PROFIBUS2) CANopen INTERBUS CC-Link

CPX-FB33 CPX-M-FB34 CPX-M-FB35 CPX-FB36 CPX-FB37 CPX-FB38 CPX-FB39 CPX-FB40 CPX-M-FB41

PROFINET RT, M12 PROFINET RT, RJ45 PROFINET RT, SCRJ EtherNet/IP EtherCAT EtherCAT Sercos III POWERLINK PROFINET RT

9 2 9 9 5 2 5 (function module F23) 9 (function module F24) 9 9 9 9 9 9 9 9 9

1) 2)

With Revision 20 (R20) With Revision 23 (R23)

PROFIBUS®, DeviceNet®, CANopen®, INTERBUS®, CC-LINK®, EtherCAT®, PROFINET®, Sercos®, EtherNet/IP® is a registered trademark of its respective trademark holder in certain countries.

150

è Internet: www.festo.com/catalogue/...

Subject to change – 2018/04