Spec sheet · Festo

Modular electrical terminal CPX

Spec sheet246 pagesPDF 8.5 MB

Festo catalog for the CPX modular electrical terminal: bus nodes, control blocks, I/O, end plates and accessories.

What this file really is

The old site listed this file as a spec sheet for the Festo CPX-EPL-EV. This is Festo's whole catalog section for the CPX terminal; the CPX-EPL-EV end plate appears only in its accessories ordering data.

Download the PDF8.5 MB

Filed with · 1 model

Also filed with these models on the old site

Summary

What is in it

Festo's catalog section for the modular electrical terminal CPX, a modular peripheral system for valve terminals that can also serve as remote I/O on a fieldbus or Industrial Ethernet. It explains the key features (electrical components, assembly, power supply, diagnostics, parameterisation, addressing), gives general technical data and accessories (interlinking blocks, end plates such as the CPX-EPL-EV, mounting), then technical and ordering data for the CPX-MMI operator unit, CPX-CEC control blocks, each bus node, the CP and CTEL interfaces and the CPX-CM-HPP axis interface.

Its parts

  1. Key features
  2. Peripherals overview
  3. Technical data
  4. Operator unit CPX-MMI-1
  5. CPX Maintenance Tool
  6. Control block CPX-CEC
  7. Bus node CPX-FB6
  8. Bus node CPX-FB11
  9. Bus node CPX-FB13
  10. Bus node CPX-FB14
  11. Bus node CPX-M-FB21
  12. Bus node CPX-FB23-24
  13. Bus node CPX-FB33
  14. Bus node CPX-M-FB34
  15. Bus node CPX-M-FB35/CPX-M-FB41

From the sheet

Key facts from this sheet

Each line names its page in the PDF.

Festo catalog for the whole modular electrical terminal CPX: bus nodes, control blocks, I/O and technology modules, interlinking blocks, end plates and pneumatic interfaces. The CPX-EPL-EV end plate appears in it only as an ordering line. It gives key features, technical data, configuration rules and ordering data for the system.

Read for this summary: pages 1 to 3, 31 to 35, 39 to 40, 45 to 52 and 214 to 217 of 246.

System type
Modular electrical peripheral system for valve terminals such as MPA-S, MPA-L and VTSA; also usable as remote I/O p. 2, 3
End plate part numbers
CPX-EPL-EV 195716; with system supply CPX-EPL-EV-S 576315; with extension CPX-EPL-EV-X 576314 p. 49
Left end plate role
Carries the earth connection and the mounting holes for wall or H-rail mounting p. 214
System supply end plate
CPX-EPL-EV-S: 7-pin plug with 24 V DC for electronics and sensors, outputs and valves; plug NECU-L3G7-C1 (576319) p. 214, 215
Supply voltage
24 V DC for electronics, inputs, valves and outputs; operating voltage tolerance ±25% p. 2, 214
Maximum modules
11 in total, for example 1 control block, 9 I/O modules and 1 pneumatic interface p. 45
Power connections
M18, 7/8" or AIDA push-pull p. 2, 39
Networks
Open to all fieldbus protocols and Ethernet; web server, remote diagnostics, text message and e-mail alert p. 2
I/O types
Digital 4-/8-/16-way; analogue 2-/4-way, optionally with HART; pressure and temperature inputs; axis controllers p. 2
Diagnostics
Channel and module diagnostics, module undervoltage detection, last 40 errors stored with timestamp p. 45
Protection class
IP65 and IP67 or IP20, depending on the components fitted p. 2, 45
Module width
50 mm p. 45
Extension limits
Two rows on one bus node; first row max 10 modules, second row max 8 plus a pneumatic interface; sensor and electronics supply 6 A first row, 2 A second p. 33
Extension cables
8-pin M12 plug on end plates with extension; cables NEBC-F12G8-KH-0.25-N-S-F12G8 to NEBC-F12G8-KH-3-N-S-F12G8, 0.25 m to 3 m p. 217

What this sheet walks you through

  • Splitting a long CPX terminal into two connected rows with end plates with extension p. 33, 216, 217
  • Which CPX modules are allowed in the first and second row p. 34
  • Mounting the CPX hood over a valve terminal p. 31, 32
  • Choosing interlinking blocks for system, output and valve power supply p. 39, 40
  • Pin allocation of the 7-pin system supply plug on the end plate p. 214
  • Ordering end plates, interlinking blocks, tie rods, mounting parts and power plugs p. 48, 49
  • Finding the user manual for each CPX component p. 50, 51, 52

Good to know

  • IP65/IP67 applies only to the fully assembled system with plugs or covers fitted; one lower-rated component lowers the whole terminal. p. 45
  • With the 3 m extension cable, only one CPX module is allowed in the second row and a valve terminal needs an additional valve supply. p. 33
  • Commercially available 7/8" accessories are often limited to 8 A. p. 40
  • The CPX hood does not protect against weather in installations that are not in closed spaces. p. 31

Questions this sheet answers

What is the part number of the CPX-EPL-EV end plate?

195716. The version with system supply is CPX-EPL-EV-S (576315) and the version with extension is CPX-EPL-EV-X (576314). p. 49

Where is the earth connection on a CPX terminal?

On the left end plate, together with the mounting holes for wall or H-rail mounting. p. 214

How many modules can one CPX terminal have?

At most 11 in total, for example 1 control block, 9 I/O modules and 1 pneumatic interface. p. 45

How long can the cable between two CPX rows be?

Max 2 m for full performance. A 3 m cable may be used, but then only one CPX module is allowed in the second row. p. 33

Which fieldbuses does the CPX terminal support?

The catalog says it is open to all fieldbus protocols and Ethernet. p. 2

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. Modular electrical terminal CPX1
    1. Key features2
    2. Peripherals overview12
    3. Key features – Electrical components22
    4. Key features – Assembly31
    5. Key features – Power supply39
    6. Key features – Diagnostics41
    7. Key features – Parameterisation42
    8. Key features – Addressing43
    9. Technical data45
    10. Operator unit CPX-MMI-153
    11. CPX Maintenance Tool57
    12. Control block CPX-CEC60
    13. Bus node CPX-FB667
    14. Bus node CPX-FB1171
    15. Bus node CPX-FB1375
    16. Bus node CPX-FB1480
    17. Bus node CPX-M-FB2184
    18. Bus node CPX-FB23-2488
    19. Bus node CPX-FB3392
    20. Bus node CPX-M-FB3496
    21. Bus node CPX-M-FB35/CPX-M-FB41100
    22. Bus node CPX-FB36104
    23. Bus node CPX-FB37108
    24. Bus node CPX-FB38112
    25. Bus node CPX-FB39116
    26. Bus node CPX-FB40120
    27. CPX-CP interface124
    28. Interface CPX-CTEL129
    29. Interface CPX-CTEL-2135
    30. Control block CPX-CM-HPP140
    31. Accessories142
    32. Axis controllers CPX-CMAX143
    33. End-position controllers CPX-CMPX146
    34. Measuring modules CPX-CMIX149
    35. Input module, digital152
    36. PROFIsafe input module157
    37. Input module, digital, 16 inputs163
    38. Output module, digital169
    39. Input/output module, digital175
19 more lines, from page 181 on
  1. Counter module, digital181
    1. HART input/output module185
    2. Analogue module for inputs190
    3. Analogue input module with pressure sensors195
    4. Analogue module for temperature inputs197
    5. Analogue module for thermocoupler201
    6. Analogue module for outputs205
    7. PROFIsafe shut-off module209
    8. End plate with system power supply214
    9. End plate with extension216
    10. Interlinking block with system supply218
    11. Interlinking block224
    12. Interlinking block with additional power supply for outputs226
    13. Interlinking block with additional power supply for valves230
    14. Pneumatic interface VMPA-FB232
    15. Pneumatic interface VMPAL234
    16. Pneumatic interface VTSA/VTSA-F235
    17. Dimensions236
    18. Accessories242

From the PDF’s own bookmarks.

The whole text · 25 parts

Read the sheet here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 101-10
  2. Pages 11 to 2011-20
  3. Pages 21 to 3021-30
  4. Pages 31 to 4031-40
  5. Pages 41 to 5041-50
  6. Pages 51 to 6051-60
  7. Pages 61 to 7061-70
  8. Pages 71 to 8071-80
  9. Pages 81 to 9081-90
  10. Pages 91 to 10091-100
  11. Pages 101 to 110101-110
  12. Pages 111 to 120111-120
  13. Pages 121 to 130121-130
  14. Pages 131 to 140131-140
  15. Pages 141 to 150141-150
  16. Pages 151 to 160151-160
  17. Pages 161 to 170161-170
  18. Pages 171 to 180171-180
  19. Pages 181 to 190181-190
  20. Pages 191 to 200191-200
  21. Pages 201 to 210201-210
  22. Pages 211 to 220211-220
  23. Pages 221 to 230221-230
  24. Pages 231 to 240231-240
  25. Pages 241 to 246241-246

The file

Revision and size

Revision2018/04
PublisherFesto
Pages246
PDF8.5 MB
TextText from the PDF itself; page 1 is a scan, read by OCR, which may hold reading errors.

The first pages · 4 of 246

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 246
Page 2
Page 2of 246
Page 3
Page 3of 246
Page 4
Page 4of 246