Summary
What is in it
Festo's catalog section for the modular electrical terminal CPX, a modular peripheral system for valve terminals that can also serve as remote I/O on a fieldbus or Industrial Ethernet. It explains the key features (electrical components, assembly, power supply, diagnostics, parameterisation, addressing), gives general technical data and accessories (interlinking blocks, end plates such as the CPX-EPL-EV, mounting), then technical and ordering data for the CPX-MMI operator unit, CPX-CEC control blocks, each bus node, the CP and CTEL interfaces and the CPX-CM-HPP axis interface.
Its parts
- Key features
- Peripherals overview
- Technical data
- Operator unit CPX-MMI-1
- CPX Maintenance Tool
- Control block CPX-CEC
- Bus node CPX-FB6
- Bus node CPX-FB11
- Bus node CPX-FB13
- Bus node CPX-FB14
- Bus node CPX-M-FB21
- Bus node CPX-FB23-24
- Bus node CPX-FB33
- Bus node CPX-M-FB34
- Bus node CPX-M-FB35/CPX-M-FB41
From the sheet
Key facts from this sheet
Each line names its page in the PDF.
Festo catalog for the whole modular electrical terminal CPX: bus nodes, control blocks, I/O and technology modules, interlinking blocks, end plates and pneumatic interfaces. The CPX-EPL-EV end plate appears in it only as an ordering line. It gives key features, technical data, configuration rules and ordering data for the system.
- System type
- Modular electrical peripheral system for valve terminals such as MPA-S, MPA-L and VTSA; also usable as remote I/O p. 2, 3
- End plate part numbers
- CPX-EPL-EV 195716; with system supply CPX-EPL-EV-S 576315; with extension CPX-EPL-EV-X 576314 p. 49
- Left end plate role
- Carries the earth connection and the mounting holes for wall or H-rail mounting p. 214
- System supply end plate
- CPX-EPL-EV-S: 7-pin plug with 24 V DC for electronics and sensors, outputs and valves; plug NECU-L3G7-C1 (576319) p. 214, 215
- Supply voltage
- 24 V DC for electronics, inputs, valves and outputs; operating voltage tolerance ±25% p. 2, 214
- Maximum modules
- 11 in total, for example 1 control block, 9 I/O modules and 1 pneumatic interface p. 45
- Power connections
- M18, 7/8" or AIDA push-pull p. 2, 39
- Networks
- Open to all fieldbus protocols and Ethernet; web server, remote diagnostics, text message and e-mail alert p. 2
- I/O types
- Digital 4-/8-/16-way; analogue 2-/4-way, optionally with HART; pressure and temperature inputs; axis controllers p. 2
- Diagnostics
- Channel and module diagnostics, module undervoltage detection, last 40 errors stored with timestamp p. 45
- Protection class
- IP65 and IP67 or IP20, depending on the components fitted p. 2, 45
- Module width
- 50 mm p. 45
- Extension limits
- Two rows on one bus node; first row max 10 modules, second row max 8 plus a pneumatic interface; sensor and electronics supply 6 A first row, 2 A second p. 33
- Extension cables
- 8-pin M12 plug on end plates with extension; cables NEBC-F12G8-KH-0.25-N-S-F12G8 to NEBC-F12G8-KH-3-N-S-F12G8, 0.25 m to 3 m p. 217
What this sheet walks you through
- Splitting a long CPX terminal into two connected rows with end plates with extension p. 33, 216, 217
- Which CPX modules are allowed in the first and second row p. 34
- Mounting the CPX hood over a valve terminal p. 31, 32
- Choosing interlinking blocks for system, output and valve power supply p. 39, 40
- Pin allocation of the 7-pin system supply plug on the end plate p. 214
- Ordering end plates, interlinking blocks, tie rods, mounting parts and power plugs p. 48, 49
- Finding the user manual for each CPX component p. 50, 51, 52
Good to know
- IP65/IP67 applies only to the fully assembled system with plugs or covers fitted; one lower-rated component lowers the whole terminal. p. 45
- With the 3 m extension cable, only one CPX module is allowed in the second row and a valve terminal needs an additional valve supply. p. 33
- Commercially available 7/8" accessories are often limited to 8 A. p. 40
- The CPX hood does not protect against weather in installations that are not in closed spaces. p. 31
Questions this sheet answers
What is the part number of the CPX-EPL-EV end plate?
195716. The version with system supply is CPX-EPL-EV-S (576315) and the version with extension is CPX-EPL-EV-X (576314). p. 49
Where is the earth connection on a CPX terminal?
On the left end plate, together with the mounting holes for wall or H-rail mounting. p. 214
How many modules can one CPX terminal have?
At most 11 in total, for example 1 control block, 9 I/O modules and 1 pneumatic interface. p. 45
How long can the cable between two CPX rows be?
Max 2 m for full performance. A 3 m cable may be used, but then only one CPX module is allowed in the second row. p. 33
Which fieldbuses does the CPX terminal support?
The catalog says it is open to all fieldbus protocols and Ethernet. p. 2
Contents
Chapters and sections
Each line opens the PDF at its page.
- Modular electrical terminal CPX1
- Key features2
- Peripherals overview12
- Key features – Electrical components22
- Key features – Assembly31
- Key features – Power supply39
- Key features – Diagnostics41
- Key features – Parameterisation42
- Key features – Addressing43
- Technical data45
- Operator unit CPX-MMI-153
- CPX Maintenance Tool57
- Control block CPX-CEC60
- Bus node CPX-FB667
- Bus node CPX-FB1171
- Bus node CPX-FB1375
- Bus node CPX-FB1480
- Bus node CPX-M-FB2184
- Bus node CPX-FB23-2488
- Bus node CPX-FB3392
- Bus node CPX-M-FB3496
- Bus node CPX-M-FB35/CPX-M-FB41100
- Bus node CPX-FB36104
- Bus node CPX-FB37108
- Bus node CPX-FB38112
- Bus node CPX-FB39116
- Bus node CPX-FB40120
- CPX-CP interface124
- Interface CPX-CTEL129
- Interface CPX-CTEL-2135
- Control block CPX-CM-HPP140
- Accessories142
- Axis controllers CPX-CMAX143
- End-position controllers CPX-CMPX146
- Measuring modules CPX-CMIX149
- Input module, digital152
- PROFIsafe input module157
- Input module, digital, 16 inputs163
- Output module, digital169
- Input/output module, digital175
19 more lines, from page 181 on
- Counter module, digital181
- HART input/output module185
- Analogue module for inputs190
- Analogue input module with pressure sensors195
- Analogue module for temperature inputs197
- Analogue module for thermocoupler201
- Analogue module for outputs205
- PROFIsafe shut-off module209
- End plate with system power supply214
- End plate with extension216
- Interlinking block with system supply218
- Interlinking block224
- Interlinking block with additional power supply for outputs226
- Interlinking block with additional power supply for valves230
- Pneumatic interface VMPA-FB232
- Pneumatic interface VMPAL234
- Pneumatic interface VTSA/VTSA-F235
- Dimensions236
- Accessories242
The whole text · 25 parts
Read the sheet here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
- Pages 1 to 101-10
- Pages 11 to 2011-20
- Pages 21 to 3021-30
- Pages 31 to 4031-40
- Pages 41 to 5041-50
- Pages 51 to 6051-60
- Pages 61 to 7061-70
- Pages 71 to 8071-80
- Pages 81 to 9081-90
- Pages 91 to 10091-100
- Pages 101 to 110101-110
- Pages 111 to 120111-120
- Pages 121 to 130121-130
- Pages 131 to 140131-140
- Pages 141 to 150141-150
- Pages 151 to 160151-160
- Pages 161 to 170161-170
- Pages 171 to 180171-180
- Pages 181 to 190181-190
- Pages 191 to 200191-200
- Pages 201 to 210201-210
- Pages 211 to 220211-220
- Pages 221 to 230221-230
- Pages 231 to 240231-240
- Pages 241 to 246241-246
The file