Page 31

Terminal CPX Key features – Assembly Hood Description

è page 244 The CPX hood CAFC is a space- and cost-saving alternative to a control cabinet. It is designed as an extruded aluminium profile and is installed on a mounting plate. The valve terminal (CPX with MPA-S or MPA-L) is well protected and is quick to install without the need for complex control cabinet installation for connecting cables and tubing.

Advantages of the CPX hood Impact protection (min. 7 J) for the underlying modules in combination with a suitable mounting plate provided by the user Protection against electrostatic dis­ charge through the use of electric­ ally conductive materials and the option of connecting an earth wire

The rail and the two mounting brack­ ets are mounted on a base plate. The hood is attached to the retaining rail and secured with two screws. There is also a stand-by position (locking of the hood in the open position). The hood is locked using two side screws (which meet the requirements for a special lock in compliance with ATEX). The CPX hood can be ordered online using the valve terminal configurator.

Points to note when using the CPX hood Protection against disconnection of live plug connectors (by securing the hood with at least one special lock to EN 600079-0, 9.2 and 20) UV protection for the underlying CPX and MPA modules

Only in combination with valve terminal MPA-S and MPA-L No bus nodes with push-pull con­ nection (CPX-M-FB34, CPX-M-FB35, CPX-M-FB41) CPX power supply via angled plugs, no T-plugs, no push-pull Electrical supply plate/additional power supply only possible with angled plug

No MPA vertical stacking Use of larger fittings (for tubing O.D. larger than 12 mm) only possible with the angled design Ducted exhaust air only with elbow connector The permissible ambient temperat­ ure of the valve terminal is reduced by 5 °C

The CPX hood has no influence on the IP protection class of the valve terminal or of the CPX terminal.

The CPX hood does not protect against the effects of the weather in installations that are not in closed spaces.

-H- Note The CPX hood has no influence on the ATEX classification of the valve terminal or of the CPX terminal.

2018/04 – Subject to change

è Internet: www.festo.com/catalogue/...

31

Page 32

Terminal CPX Key features – Assembly Hood Mounting Procedure: Assemble the rail and mounting bracket included in the mounting kit Attach the earth cable Assemble the hood (if applicable, screw together several hood sections before attaching the side pieces) Attach and secure the hood

4

3

2

1

5

1 2 3 4

Side piece Earth cable Hood section Slot nut with screws, for joining the hood sections 5 Rail 6 Mounting bracket

6 Technical data Weight: Hood: approx. 500 g per 100 mm of length Mounting rail: approx. 550 g per 1000 mm of length Side pieces: approx. 500 g per side

Ambient temperature –5 … +50 °C

RoHS-compliant

The connection blocks CPX-P-AB-2XKL-8POL and the sockets NECU-L3G8 can be matched to one another using the coding elements CPX-P-KDS-AB-2XKL.

This reduces the likelihood of a socket being inserted in the wrong slot after it is removed from the CPX terminal (protection against incorrect insertion).

Plug coding

32

è Internet: www.festo.com/catalogue/...

Subject to change – 2018/04

Page 33

Terminal CPX Key features – Assembly Extension Functional principle The extension enables the CPX terminal to be separated into or configured as two interconnected units (series). The two parts are controlled by a common bus node or control block. An extensive CPX terminal can fit into limited installation spaces more easily in the form of two compact units.

Applications: Installation in a control cabinet on two levels, one beneath the other Installation in two separate control cabinets Installation of part of the CPX terminal inside and part outside the control cabinet Spatial separation of electrics and pneumatics

The number of CPX modules and solenoid coils is additionally limited by:

the address space made available by the control block/bus node their address requirement their current consumption

The control block/bus node is installed in the first row, on the far right, on an interlinking block with system supply

The connecting cable between the first and second row is max. 2 m long

An interlinking block with addi­ tional power supply for valves is situated in the second row

If the 3 m connecting cable is used, the following restrictions are in place: There can only be one CPX module in the second row An additional power supply for valves is required in order to connect a valve terminal

Positioning output modules in the second row requires a corresponding power supply in the second row:

Install interlinking block with addi­ tional power supply for outputs in the second row to the left of the first output module

Performance limits A maximum of 10 CPX modules are permitted on the first row A maximum of 8 CPX modules and a pneumatic interface are permitted in the second row Optimisation The maximum possible performance or maximum number of modules can only be achieved if the following conditions are observed:

Configuration rules The extension limits the power supply for the sensors and electronics for the CPX terminal as a whole as follows: first row max. 6 A second row max. 2 A first and second row together, max. 6 A

2018/04 – Subject to change

è Internet: www.festo.com/catalogue/...

33

Page 34

Terminal CPX Key features – Assembly Extension – Permissible CPX modules Control blocks Bus node

Type

First row

CPX-CEC

Permissible, at least one control block or bus Not permissible node required Permissible, at least one control block or bus Not permissible node required Permissible Not permissible

CPX-FB CPX-M-FB Technology modules CPX-CP CPX-CTEL CPX-CTEL-2 CPX-CM-HPP CPX-CMAX CPX-CMPX CPX-CMIX Input/output modules CPX PROFIsafe shut-off module CPX-FVDA-P2 Interlinking block/end plate with CPX-EPL-EV-S system supply CPX-GE-EV-S CPX-M-GE-EV-S Interlinking block with additional power CPX-GE-EV-Z supply CPX-M-GE-EV-Z CPX-GE-EV-V Interlinking block without supply CPX-GE-EV CPX-M-GE-EV Pneumatics interface VMPA-FB VMPAL-EPL-CPX VABA-S6-1

34

Second row

Permissible Not permissible Permissible, at least one interlinking block/ end plate with system supply required

Permissible Not permissible Not permissible

Permissible

Permissible

Permissible

Permissible

Not permissible Not permissible Not permissible

Permissible Permissible Permissible

è Internet: www.festo.com/catalogue/...

Subject to change – 2018/04

Page 35

Terminal CPX Key features – Assembly Extension – Maximum number of CPX modules/solenoid coils Special features of the design

First row

Second row

CPX terminal with valve terminal Connecting cable 3 m

10 CPX modules

Valve terminal MPA-S with: Pneumatic interface for CPX metal interlinking module Electrical air supply plate VMPA-FB-SP directly after the pneumatic interface Electronics modules with galvanic isolation 128 solenoid coils (64 valve positions) Valve terminal VTSA/VTSA-F with: 1 CPX module with interlinking block with additional power supply for valves 32 solenoid coils (32 valve positions)

10 CPX modules

2 … 5 CPX modules, depending on the control block/bus node used

10 CPX modules

4 … 8 CPX modules, depending on the control block/bus node used

10 CPX modules

10 CPX modules

2 … 5 CPX modules and manifold blocks MPA-S, depending on the control block/bus node used 2 … 5 CPX modules, depending on the control block/bus node used Up to 128 solenoid coils (64 valve positions) 4 … 5 CPX modules and manifold blocks MPA-S, depending on the control block/bus node used 8 CPX modules and manifold blocks MPA-S

10 CPX modules

8 CPX modules and manifold blocks MPA-S

10 CPX modules

8 CPX modules and manifold blocks MPA-S

CPX terminal without valve terminal Control block/bus node not in position on the far right of the first row Control block/bus node in position on the far right of the first row CPX terminal with valve terminal MPA-S – Electrical air supply plates VMPA-FB-SP Electronics modules with galvanic isolation Control block/bus node in position on the far right of the first row CPX-FB11 or CPX-CEC not possible CPX-FB13 or CPX-FB36 Control block/bus node in position on the far right of the first row Interlinking block with system supply in position on the far right of the first row CPX-FB13 or CPX-FB36 Control block/bus node in position on the far right of the first row Interlinking block with additional power supply for valves in position on the far right of the first row CPX-FB13 or CPX-FB36 Control block/bus node in position on the far right of the first row Interlinking block with additional power supply for valves in second row

2018/04 – Subject to change

10 CPX modules 10 CPX modules

è Internet: www.festo.com/catalogue/...

35

Page 36

Terminal CPX Key features – Assembly Extension – Maximum number of CPX modules/solenoid coils Special features of the design

First row

Second row

CPX terminal with valve terminal MPA-L –

10 CPX modules

2 CPX modules (at least one CPX module required) 16 solenoid coils (valve widths 10 mm and 14 mm) or 8 solenoid coils (valve width 20 mm) 2 CPX modules (at least one CPX module required) 32 solenoid coils (32 valve positions)

Interlinking block with additional power supply for valves in second 10 CPX modules row CPX terminal with valve terminal VTSA/VTSA-F –

10 CPX modules

Interlinking block with additional power supply for valves in second 10 CPX modules row

36

è Internet: www.festo.com/catalogue/...

2 CPX modules 12 solenoid coils (valve widths 18 mm and 26 mm and 42 mm) or 6 solenoid coils (valve widths 52 mm and 65 mm) 2 CPX modules 32 solenoid coils (32 valve positions)

Subject to change – 2018/04

Page 37

Terminal CPX Key features – Assembly Mounting options Valve terminals with CPX terminal support different mounting options for direct machine mounting a high degree of high protection and control cabinet installation.

H-rail mounting

A

The H-rail mounting is part of the re­ verse profile of the CPX interlinking blocks. The CPX terminal can be at­ tached to the H-rail using the H-rail mounting kit. The CPX terminal is mounted on the H-rail for this purpose (see arrow A).

It is then swivelled onto the H-rail and secured in place with the clamping component (see arrow B). The optional earthing plate enables a connection to be established to the machine potential/earth in one easy step.

For H-rail mounting you will need the following mounting kit: CPX-CPA-BG-NRH This facilitates mounting of the CPX terminal on H-rails to EN 60715. An additional mounting kit is required for combination with valve terminals.

B

Wall mounting, plastic design The end plates of the CPX terminal, the valve terminal and the pneumatic interface include mounting holes for wall mounting. Additional mountings for the CPX terminal are available for longer valve terminals. These mount­ ings differ depending on the design of the CPX terminal (plastic or metal).

Wall mounting, metal design

2018/04 – Subject to change

è Internet: www.festo.com/catalogue/...

37

Page 38

Terminal CPX Key features – Assembly Plastic design CPX terminal Additional mountings For longer valve terminals, there are additional mounting components for the CPX terminal that can be fitted between two modules.

-H- Note In the case of CPX terminals with 4 and more interlinking blocks, additional mountings of the type CPX-BG-RW must be used every 100 or 150 mm. These are supplied preassembled.

Interlinking with tie rods

1

2

The CPX modules are mechanically connected using special tie rods 2. Two screws in the end plates are all that are needed to assemble the entire unit. The tie rod ensures that the unit resists high mechanical loads and is therefore the mechanical backbone of the CPX terminal.

The open design enables interlinking blocks 1 to be replaced in the assembled state. The tie rod expansion kit 3 enables an extra module to be added to the CPX terminal.

For longer valve terminals, there are additional mounting brackets for the CPX terminal that can be screwed onto the interlinking blocks. The mounting bracket CPX-M-BGVT-2X enables a CPX terminal with valve terminal VTSA/VTSA-F to be mounted on a support system.

-H- Note

3

CPX terminal in metal design Additional mountings

In the case of CPX terminals with 4 and more interlinking blocks, addi­ tional mounting brackets of the type CPX-M-BG-RW must be used every 100 or 150 mm. These are supplied pre-assembled.

Linking with screws The CPX modules are mechanically connected using a special angled fitting. The CPX terminal can thus be expanded at any time.

38

è Internet: www.festo.com/catalogue/...

Subject to change – 2018/04

Page 39

Terminal CPX Key features – Power supply Power supply concept General

The use of decentralised devices on the fieldbus – particularly with a high degree protection for direct machine mounting – demands a flexible power supply concept. A valve terminal with CPX can, in principle, supply all voltages via a single connection. A distinction is made between the supply for Electronics plus sensors Valves plus actuators in this case.

Selectable connection technology: M18 7/8" AIDA push-pull as well as their bus connections. Many applications require the CPX terminal to be segmented into voltage zones. This applies in particular to the separate disconnection of solenoid coils and outputs. The interlinking blocks provide either a space-saving central power supply for the entire CPX terminal or galvanically isolated, all-pin disconnectable potential groups/ voltage segments.

Interlinking blocks Interlinking blocks represent the backbone of the CPX terminal with all supply lines. They provide the power supply for the modules used on them

2018/04 – Subject to change

è Internet: www.festo.com/catalogue/...

39

Page 40

Terminal CPX Key features – Power supply Interlinking blocks With system supply Type for plastic design CPX-GE-EV-S CPX-GE-EV-S-7/8-4POL CPX-GE-EV-S-7/8-5POL

Connection technology M18 4-pin 7/8" 4-pin 7/8" 5-pin

Type for metal design CPX-M-GE-EV-S-7/8-CIP-4P CPX-M-GE-EV-S-7/8-5POL CPX-M-GE-EV-S-PP-5POL

Connection technology 7/8" 4-pin 7/8" 5-pin AIDA push-pull, 5-pin

Power supply For CPX terminal modules and connected sensors For valves that are connected to the CPX terminal via a pneumatic interface For actuators that are connected to the output modules of the CPX terminal

Type for plastic design CPX-GE-EV

–

–

Without power supply

Type for metal design CPX-M-GE-EV CPX-M-GE-EV-FVO

–

Type for plastic design CPX-GE-EV-Z CPX-GE-EV-Z-7/8-4POL CPX-GE-EV-Z-7/8-5POL

Connection technology M18 4-pin 7/8" 4-pin 7/8" 5-pin

Type for metal design CPX-M-GE-EV-Z-7/8-5POL CPX-M-GE-EV-Z-PP-5POL

Connection technology 7/8" 5-pin AIDA push-pull, 5-pin

Type for plastic design CPX-GE-EV-V CPX-GE-EV-V-7/8-4POL

Connection technology M18 4-pin 7/8" 4-pin

-H- Note

-H- Note

-H- Note

For 7/8": – Commercially available accessories are often limited to max. 8 A

Valve terminal MPA-S has either a 7/8" 5-pin, 7/8" 4-pin, 3-pin M18 or 5-pin AIDA push-pull power supply for one or more valve voltage zones. Galvanically isolated, all pins disconnectable with voltage monitoring in the following MPA module.

Suitable versions of the interlinking blocks with M18 and 7/8", 5-pin connection are available (CPX-GEEV-…-VL and CPX-M-GE-EV-…-VL) for use in ATEX environments as per certification (è page 47). The max­ imum current supply for these inter­ linking blocks in 8 A.

With additional power supply for outputs Power supply For actuators that are connected to the output modules of the CPX terminal

With additional power supply for valves

40

è Internet: www.festo.com/catalogue/...

Power supply For valves that are connected to the CPX terminal via a pneumatic interface

Subject to change – 2018/04