The text of a spec sheet · part 2 of 25
Modular electrical terminal CPX, pages 11 to 20
Pages 11 to 20 of 246
The original document is the PDF (8.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Festo CPX-EPL-EV
Page 11
Terminal CPX Key features Ordering The CPX terminal with valve terminal is fully assembled according to your order specifications and individually tested. The finished valve terminal consists of the electrical peripherals including the desired actuation and the selected components of the VTSA (ISO), VTSA-F, MPA-S or MPA-L modules.
2018/04 – Subject to change
The CPX terminal with valve terminal is ordered using two separate order codes. One order code defines the electrical peripherals type CPX, while the other specifies the pneumatic components of the valve terminal. The electrical peripherals type CPX can also be configured without a valve ter minal and can be used on a fieldbus. For this order, only the order code for the electrical peripherals is required.
The order lists for the pneumatic components can be found on è Internet: vtsa (valve terminal VTSA) è Internet: vtsa-f (valve terminal VTSA-F) è Internet: mpa-s (valve terminal MPA-S) è Internet: mpa-l (valve terminal MPA-L)
è Internet: www.festo.com/catalogue/...
The order lists for the CP/CPI components can be found on è Internet: ctec (CPI installation system) The order lists for the CTEU/CTEL components can be found on è Internet: cteu (I-Port interface/IO-Link)
11
Page 12
Terminal CPX Peripherals overview Complete overview of modules
End plate
Bus node
Control block
CP interface/CTEL interface
Mounting holes for wall mounting Functional earth connection Special earthing plate for safe and easy connection to the machine bed or H-rail External power supply for the entire system
Fieldbus/Industrial Ethernet connection using various types of connection technology Setting of fieldbus parameters via DIL switch Display of fieldbus and peripheral equipment status via LED PROFINET to AIDA standard in metal housing, fast start-up
Pre-processing, stand-alone controller or remote unit CPX-CEC Connection via Ethernet TCP/IP or Sub-D programming interface Setting of operating modes via DIL switch and program selection via rotary switch CPX-CMX products for controlling axes
Interfaces for decentralised instal lation systems, thus optimising the pneumatic control chains (short tubes/short cycle times) Actuation for I/O modules and valve terminals Power supply and bus interface via the same cable
Operator unit
Web monitor
Input/output modules
Connection to bus nodes or control block Display and modification of parameter settings Plain-text display for texts, messages (e.g. individual channel diagnostics, condition monitoring), menus, etc.
Website integrated in the CPX terminal Dynamic status display Online diagnostics SMS/e-mail alert
Combination of Interlinking block Electronics module Connection block
12
è Internet: www.festo.com/catalogue/...
Subject to change – 2018/04
Page 13
Terminal CPX Peripherals overview Complete overview of modules
1 2
3 Input/output modules 1 Interlinking block
2 Electronics module
3 Connection block
Internal linking of the power supply and serial communication External power supply for the entire system Additional power supply for outputs or valves Connection accessories for M18, 7/8" or AIDA push-pull Plastic design: linking with tie rods Metal design: individual linking with M6 screws, individually expandable
Digital inputs for connecting the sensors Digital outputs for activating additional actuators Analogue inputs Temperature inputs (analogue) Analogue outputs PROFIsafe input module for safetyoriented sensor technology PROFIsafe shut-off module with two digital outputs for shutting off the supply voltage for valves
Choice of 8 connection technology variants Protection class IP65, IP67 or IP20 Can be combined with the electronics modules M8/M12/Sub-D/quick connection M8/M12/Sub-D, etc. connecting cables Modular system for M8/M12 connecting cables M12 connection technology for the metal design
2018/04 – Subject to change
Pneumatics interface
è Internet: www.festo.com/catalogue/...
MPA-S MPA-L VTSA/VTSA-F
13
Page 14
Terminal CPX Peripherals overview Individual overview of modules Bus node
è page 67 Bus node for PROFIBUS DP INTERBUS DeviceNet CANopen CC-LINK
Ethernet/IP PROFINET POWERLINK EtherCAT Sercos III
è page 60
Control block CPX-CEC Programming with CODESYS Ethernet interface Modbus/TCP EasyIP CANopen master
è page 124
CP interface Interface CPX-CP 4 CP strings Max. 4 modules per string 32 inputs/32 outputs per string CPI functionality
è page 129
CTEL interface CPX-CTEL interface CTEL master Max. 4 devices with individual electronic fuse protection Max. 64 inputs/64 outputs per I-Port interface The maximum length of a string is 20 m
è page 135
Electrical interface CPX-CTEL-2 Interface CPX-CTEL-2 Master for IO-Link Max. 2 devices with individual electronic protection Process data length of the inputs and outputs is limited to 16 bytes for inputs and 16 bytes for outputs per port The maximum length of a string is 20 m
14
è Internet: www.festo.com/catalogue/...
Subject to change – 2018/04
Page 15
Terminal CPX Peripherals overview Individual overview of modules Modules for actuating electric drive units
è page 140 CPX-CM-HPP Axis interface CAN bus for up to 4 individual electric axes
è page 143
Modules for controlling pneumatic drive units CPX-CMAX Axis controller Position and force control 64 configurable positioning records Auto-identification Control of a brake or clamping unit via the proportional directional control valve VPWP
CPX-CMPX End-position controller Fast travel between the mechanical end stops of the cylinder Smooth travel into the end position Improved control of downtime Control of a brake via the propor tional directional control valve VPWP
CPX-CMIX Measuring module CAN input (Festo specification) for measuring signal Recording of the absolute position values or speed values of the connected drive
Direct machine mounting (protection class IP65, IP67) M8-3POL M8-4POL M12-5POL M12-5POL quick lock, metal thread screened M12-8POL Sub-D Quick connector Spring-loaded terminal with cover
Protected fitting space (protection class IP20) Spring-loaded terminal
Screening concept Optional screening plate for connection blocks with M12 connection technology
Plastic connection block
Metal manifold block Direct machine mounting (protection class IP65, IP67) M12-5POL
Connection block including electronics module and interlinking block Installation in the control cabinet (protection class IP20) Plastic connection block Spring-loaded terminal Digital input module with 16 inputs Digital I/O module with 8 inputs and 8 outputs
2018/04 – Subject to change
è Internet: www.festo.com/catalogue/...
15
Page 16
Terminal CPX Peripherals overview Individual overview of modules Connection block for HART input/output module Direct machine mounting (connection block to IP65) M12-4POL
Protected fitting space (connection block to IP20) Screw terminal Spring-loaded terminal
è page 152
Digital electronics module for inputs/outputs Digital inputs 4 digital inputs 8 digital inputs NPN 8 digital inputs PNP 8 digital inputs PNP with individual channel diagnostics 16 digital inputs 16 digital inputs with individual channel diagnostics
Digital outputs 4 digital outputs (1 A per channel, individual channel diagnostics) 8 digital outputs (0.5 A per chan nel, individual channel diagnostics) 8 digital outputs (2.1 A/50 W lamp load per channel pair, individual channel diagnostics)
Multi I/O modules 8 digital inputs and 8 digital outputs 2 digital inputs (counter channels, connection to various encoders) and 2 digital outputs (directly controlled by the input values)
Analogue temperature inputs 4 analogue inputs for temperature measurement (Pt100, Pt200, Pt500, Pt1000, Ni100, Ni120, Ni500, Ni1000) 4 analogue inputs for temperature measurement (thermocoupler and PT1000 sensor for cold-junction compensation)
Analogue outputs 2 analogue outputs (0 … 10 V DC, 0 … 20 mA, 4 … 20 mA)
è page 190
Analogue electronics module for inputs/outputs Analogue inputs 2 analogue inputs (0 … 10 V DC, 0 … 20 mA, 4 … 20 mA) 4 analogue inputs (1 … 5 V, 0 … 10 V, –5 … +5 V, –10 … +10 V, 0 … 20 mA, 4 … 20 mA, –20 … +20 mA) 4 analogue inputs with HART protocol
è page 157
PROFIsafe input module Digital inputs 8 digital inputs 11 function modes 5 independent clock outputs
è page 209
PROFIsafe shut-off module Digital outputs 2 digital outputs Supply voltage for valves can be shut off
16
è Internet: www.festo.com/catalogue/...
Subject to change – 2018/04
Page 17
Terminal CPX Peripherals overview Individual overview of modules Analogue electronics module for pressure inputs
è page 195
Analogue inputs 4 analogue supply ports (0 … 10 bar, –1 … +1 bar)
è page 218
Plastic interlinking block – Interlinking by means of tie rods System linking Different voltages for supplying the modules Serial communication between the modules System supply M18 4-pin 7/8" 4-pin or 5-pin
In addition to system linking, power supply for the electronics plus sensors (16 A) valves plus actuators (16 A) Additional power supply In addition to system linking, power supply for the actuators (16 A per supply)
In addition to system linking, power supply for the electronics plus sensors (16 A) valves plus actuators (16 A)
System supply 7/8" 4-pin or 5-pin AIDA push-pull
Additional power supply In addition to system linking, power supply for the actuators (16 A per supply)
-H- Note
-H- Note
-H- Note
Plastic interlinking blocks (tie rods) and metal interlinking blocks (indi vidual linking) cannot be combined due to their different interlinking systems.
The 7/8" supply is subject to the following restriction due to the available accessories: 5-pin 8 A 4-pin 10 A
The usage of appropriate interlink ing blocks (CPX-…-VL) is required for use in ATEX environments as per approval certificate (è page 47). The maximum supply is limited to 8 A for these modules.
2018/04 – Subject to change
Expandability Can be expanded using an inter linking block with tie-rod extension CPX-ZA-1-E
è page 218
Metal interlinking block – Individual linking System linking Different voltages for supplying the modules Serial communication between the modules
Power supply for the valves (16 A per supply)
è Internet: www.festo.com/catalogue/...
Power supply for the valves (16 A per supply) Expandability Can be expanded as required by up to 10 interlinking blocks
17
Page 18
Terminal CPX Peripherals overview Individual overview of modules Pneumatic interface MPA-S
è page 232 Valve terminal MPA1 (360 l/min) MPA2 (700 l/min) Up to 128 solenoid coils Up to 16 modules can be configured For CPX plastic design For CPX metal design Actuation of pressure sensors Proportional pressure regulators Pressure sensors Proportional pressure regulators
Pneumatic interface VTSA/VTSA-F
Pneumatic interface MPA-L
è page 234 Valve terminal MPA1 (360 l/min) MPA14 (670 l/min) MPA2 (870 l/min) Up to 32 solenoid coils For CPX plastic design
è page 235 Valve terminal (valve flow rate according to width) 18 mm (700 l/min) 26 mm (1350 l/min) 42 mm (1300 l/min) 52 mm (2900 l/min) 65 mm (4000 l/min) Max. 32 valve positions/ max. 32 solenoid coils For CPX plastic design For CPX metal design
18
è Internet: www.festo.com/catalogue/...
Subject to change – 2018/04
Page 19
Terminal CPX Peripherals overview Individual overview of modules End plate for plastic/metal design
End plate with system power supply End plate Left-hand Right-hand (for using of the CPX terminal without valves)
End plate with extension
è page 216
Earthing plate (for end plate for plastic design)
End plate Left-hand Right-hand Enables the CPX terminal to be separated into two interconnected units (series) Simplifies control cabinet installation For plastic or metal design
2018/04 – Subject to change
è page 214 End plate Left-hand For plastic design Different voltages for supplying the CPX terminal
Earthing plate For safe and easy connection to the machine bed or H-rail, suitable for right-hand and left-hand end plate Assembly and earthing in a single processing step, which means: – 50% time saving – No additional material required
è Internet: www.festo.com/catalogue/...
19
Page 20
Terminal CPX Peripherals overview General basic data and guidelines Address capacity max. 512 inputs and 512 outputs, depending on bus node or control block One interlinking block with system supply Multiple interlinking blocks with additional power supply, always po sitioned to the right of the interlink ing block with system supply The connection blocks can, with just a few exceptions, be freely com bined with the electronics modules for inputs/outputs, either in metal or plastic (è table below) The electronics modules for inputs/ outputs can be combined with various interlinking blocks
Max. 11 modules in total: One bus node and/or one control block, freely positionable Up to 9 additional input/output modules, freely positionable An additional pneumatic interface always positioned as the last module on the right-hand side – With VTSA and VTSA-F: fixed operating range, set using DIL switch – With MPA-S: 16 MPA modules can be configured – With MPA-L: fixed operating range, set using rotary switch
Combinations of connection blocks and digital input modules Digital electronics modules CPX-4DE CPX-8DE Connection blocks, plastic design CPX-AB-8-M8-3POL CPX-AB-8-M8X2-4POL CPX-P-AB-4XM12-4POL CPX-AB-4-M12x2-5POL CPX-AB-4-M12x2-5POL-R CPX-AB-8-M12X2-5POL CPX-AB-4-M12-8POL CPX-AB-8-KL-4POL CPX-P-AB-2XKL-8POL CPX-AB-1-SUB-BU-25POL CPX-AB-4-HAR-4POL CPX-AB-ID-P n – – n n – – n – n n –
Connection blocks, metal design CPX-M-AB-4-M12X2-5POL CPX-M-AB-4-M12X2-5POL-T CPX-M-AB-8-M12X2-5POL n – –
20
CPX-16DE
CPX-L-16DE n – – n n – – n – n n –
– n – – – – – n – n – –
– – – – – – – – – – – –
– – – – – n – – – – – – n – –
– – –
– – –
– – n
è Internet: www.festo.com/catalogue/...
Plastic interlinking blocks (tie rods) and metal interlinking blocks (indi vidual linking) cannot be combined due to their different interlinking systems
CPX-M-16DE-D CPX-8DE-D
CPX-8NDE
CPX-F8DE-P n – – n n – – n – n n – n – – n n – – n – n n n
– – – – – – – n – – – n n – – n n – n n –
Subject to change – 2018/04