The text of a spec sheet · part 6 of 25
Modular electrical terminal CPX, pages 51 to 60
Pages 51 to 60 of 246
The original document is the PDF (8.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Festo CPX-EPL-EV
Page 51
Terminal CPX Accessories User manuals – General information Comprehensive user manuals are vital for the fast and reliable use of fieldbus components. The manuals provided by Festo contain step-by-step instructions for using CPX terminals: 1. Installation 2. Commissioning and parameterisation 3. Diagnostics
Application-oriented explanations are provided for integration of the CPX terminal in the programming and configuration software of the various controller manufacturers. Use the order code to select the language you want. The manual for the configuration you have ordered is supplied automatically. The documents can be quickly and easily downloaded from the Festo website. è www.festo.com
Overview – User manuals Type
Title
Description
P.BE-MPA-…
Valve terminals with VTSA and VTSA-F pneumatics Valve terminals with MPA-S pneumatics
MPAL-VI-…
Valve terminals
Instructions on assembly, installation, commissioning and diagnostics of the VTSA and VTSA-F pneumatic components. Instructions on assembly, installation, commissioning and diagnostics of the MPA-S pneumatic components. Instructions on assembly, installation, commissioning and diagnostics of the MPA-L pneumatic components.
Pneumatic components P.BE-VTSA-44-…
2018/04 – Subject to change
è Internet: www.festo.com/catalogue/...
51
Page 52
Terminal CPX Accessories Overview – User manuals Type Electronic components P.BE-CPX-SYS-…
Title
Description
System description, installation and commissioning
Overview of the design, components and mode of operation of the CPX ter minal; installation and commissioning instructions as well as basic principles of parameterisation Connection technology and instructions on mounting, installing and commis sioning for the PROFIsafe shut-off module of the type CPX-FVDA-P2 Connection technology and assembly, installation and commissioning instructions for digital input and output modules of the type CPX-… as well as VTSA/VTSA-F and MPA-S/L pneumatic interface Connection technology and assembly, installation and commissioning instructions for PROFIsafe input module of the type CPX-F8DE-P Connection technology and instructions on mounting, installing and commis sioning for the counter module of the type CPX-2ZE2DA Connection technology and assembly, installation and commissioning instructions for analogue input and output modules of the type CPX-… Instructions on assembly, installation, commissioning and diagnostics of the CP interface Instructions on assembly, installation, commissioning and diagnostics of the CPX CTEL master Instructions on assembly, installation, commissioning and diagnostics of the electrical interface CPX for IO-Link Instructions on assembly, installation, commissioning and diagnostics of the CPX axis interface (CM-HPP) Instructions on assembly, installation, commissioning and diagnostics of the CPX axis controller (CMAX) Information on controlling, diagnosing and parameterising the axis controller via the fieldbus Instructions on assembly, installation, commissioning and diagnostics of the CPX end-position controller (CMPX) Instructions on assembly, installation, commissioning and diagnostics of the CPX measuring module (CMIX) Instructions on assembly, installation, commissioning and diagnostics of the relevant bus nodes Instructions on assembly, installation, commissioning and diagnostics of the relevant bus nodes Instructions on assembly, installation, commissioning and diagnostics of the relevant control block Instructions on assembly, installation, commissioning and diagnostics of the CPX operator unit
P.BE-CPX-FVDA-P2-…
PROFIsafe shut-off module
P.BE-CPX-EA-…
CPX-EA modules, digital
P.BE-CPX-F8DE-P-…
Input module CPX-F8DE-P
P.BE-CPX-2ZE2DA-…
EA module CPX-2ZE2DA
P.BE-CPX-AX-…
CPX-EA modules, analogue
P.BE-CPX-CP…
CPX CP interface
P.BE-CPX-CTEL…
CPX CTEL interface
P.BE-CPX-CTEL-LK…
Electrical interface CPX-CTEL-2
CPX-CM-HPP…
CPX axis interface
P.BE-CPX-CMAX-SYS…
CPX axis controller
P.BE-CPX-CMAX-CONTROL…
CPX axis controller
P.BE-CPX-CMPX-SYS…
CPX end-position controller
P.BE-CPX-CMIX…
CPX measuring module
P.BE-CPX-FB… CPX-FB… P.BE-CPX-PNIO…
CPX bus node
P.BE-CPX-CEC…
CPX CoDeSys controller (control block)
P.BE-CPX-MMI-1-…
Universal handheld type CPX-MMI-1
CPX bus node for PROFINET
User manuals – GSD, EDS, etc. Device description files and icons are used to explain the integration of the CPX terminal in the configuration software of the various controller manufacturers. These can be downloaded quickly and easily from www.festo.com.
52
è Internet: www.festo.com/catalogue/...
Subject to change – 2018/04
Page 53
Terminal CPX Technical data – Operator unit CPX-MMI-1
-K- Width
81 mm
The operator unit is a small, conveni ent commissioning and service device for the CPX terminal. It provides data polling, configuration and diagnostic functions for CPX terminals. Its extremely flexible application range means that data can be read in or out at any location. IP65 compatibility makes it suitable for use in harsh industrial environments.
Application Functions Advance commissioning through the monitoring/forcing of inputs and outputs without fieldbus master/PLC Test function for parameter settings, for example fail-safe of the outputs or switch-on delay of the inputs Plain-text diagnostics of module and channel-oriented errors Condition monitoring: preselection/loading of counters, activation of the channels to be monitored Display of the last 40 error occurrences with timestamp Identification of sporadic causes of errors through display of the diagnostic history Password protection
2018/04 – Subject to change
Connection The operator unit is connected to the CPX bus nodes or control block, as appropriate, using a M12 connecting cable. The voltage for the operator unit is supplied by the CPX component
Communication Once connected to the CPX terminal, the operator unit loads the available configuration for the I/O modules, valves, etc. This ensures the availability of up-to-date texts, messages, menus and displays. Status information, diagnostic messages and parameter bits are then exchanged during operation.
è Internet: www.festo.com/catalogue/...
Assembly A mounting bracket for the operator unit offers the option of wall or H-rail mounting. The mounting bracket also has an option for temporary mounting using a hanging device.
53
Page 54
Terminal CPX Technical data – Operator unit CPX-MMI-1 Connection The operator unit is connected to the CPX terminal using a preassembled connecting cable.
Function examples System overview Overview of configured modules and current diagnostic messages
Diagnostics Fast access to the diagnostic history and the modules with diagnostic messaging Display of the last 40 diagnostic messages with timestamp Display of the current diagnostic message for a module
Commissioning Selection of module-specific data and parameters Display and modification of the current status of the inputs and outputs of a module Display and modification of the current settings for module-specific parameters
Setup Setting of access permission (password) Contrast setting of the display
54
è Internet: www.festo.com/catalogue/...
Subject to change – 2018/04
Page 55
Terminal CPX Technical data – Operator unit CPX-MMI-1 General technical data Type
CPX-MMI-1
Data interface Display component Control elements Electromagnetic compatibility Nominal operating voltage Operating voltage range Current consumption Protection class to IEC 60529 Relative air humidity Vibration resistance
[V DC] [V DC] [mA] [%]
Shock resistance
Materials Dimensions (W x H x D) Weight
[mm] [g]
RS232 interface, 57.6 kBaud, M12 socket, 4-pin LCD graphical display with background illumination (128 x 64 pixels) 7 keys: 4 arrow keys and 3 function keys, touch-sensitive keypad Interference emission tested to DIN EN 61000-6-4, industry Interference immunity tested to DIN EN 61000-6-2, industry 24, supplied by the connected device 18 … 30 50 … 60 IP65 90, non-condensing Tested to DIN/IEC 68/EN 60068, Part 2-6 With wall mounting: Severity level 2 With H-rail mounting: Severity level 1 Tested to DIN/IEC 68/EN 60068, Part 2-27 With wall mounting: Severity level 2 With H-rail mounting: Severity level 1 Reinforced PA 81 x 137 x 28 150
Operating and environmental conditions Ambient temperature CE mark (see declaration of conformity)
[°C]
ATEX category
Gas Dust Gas Dust [°C]
EX-ignition protection type ATEX ambient temperature 1)
0 … 50 To EU EMC Directive1) In accordance with EU Explosion Protection Directive (ATEX) II 3 G II 3 D Ex nA IIC T6 X Gc Ex tc IIIC T60°C X Dc IP65 –5 <= Ta <= +50
For information about the applicability of the component see the manufacturer’s EC declaration of conformity at: www.festo.com/sp è Certificates. If the component is subject to restrictions on usage in residential, office or commercial environments or small businesses, further measures to reduce the emitted interference may be necessary.
-H- Note When operating device combinations in hazardous areas, the lowest common zone, temperature class and ambient temperature of the individ ual devices determine the possible use of the entire module.
Connection and display components
1
2 3 4
2018/04 – Subject to change
1 2 3 4
Display (LCD display) Function keys Arrow keys M12 interface
è Internet: www.festo.com/catalogue/...
55
Page 56
Terminal CPX Accessories – Operator unit CPX-MMI-1 Ordering data Designation
Part No.
Type
Provides data polling, configuration and diagnostic functions for CPX terminals
529043
CPX-MMI-1
Connecting cable M12-M12, specially for CPX-MMI
1.5 m
529044
KV-M12-M12-1,5
3.5 m
530901
KV-M12-M12-3,5
Bracket
534705
CPX-MMI-1-H
Mounting for H-rail
536689
CPX-MMI-1-NRH
534824 534825 534827 534828 534826
P.BE-CPX-MMI-1-DE P.BE-CPX-MMI-1-EN P.BE-CPX-MMI-1-FR P.BE-CPX-MMI-1-IT P.BE-CPX-MMI-1-ES
Operator unit
Connecting cable
Mounting
User manual User manual for operator unit CPX-MMI-1
56
è Internet: www.festo.com/catalogue/...
German English French Italian Spanish
Subject to change – 2018/04
Page 57
Terminal CPX Technical data – CPX Maintenance Tool Function CPX Maintenance Tool (CPX-FMT) com bines service software with a connect ing adapter. The service software is a tool for the design, parameterisation and online diagnostics of the CPX terminal. The USB-to-M12 adapter features built-in galvanic isolation (between CPX and PC) and enables a PC to be connected to the diagnostic interface of the CPX terminal.
Adapter Software on CD-ROM
Application Only from Festo The CPX-FMT software enables access to CPX valve terminals via Ethernet and the bus nodes EtherNet/IP (FB 36), Sercos III (FB 39) and PROFINET (FB 33, FB 34, FB 35, FB 41). The bus nodes or control block can be connected directly to the PC via a USB adapter from Festo.. Similar to the CPX-MMI, diagnostic data such as the error trace or module diagnostics can be read out and parameters can be modified in plain text. In contrast to the CPX-MMI, the data can be used directly on a PC. There is an option, for example, to send screenshots of a configuration or the current error trace directly via e-mail. In addition, CPX configurations can also be saved
General technical data Type System requirements performed without an existing con troller infrastructure. It must be noted that with both the CPX-FMT and the CPX-MMI, only local parameters on the CPX valve terminal can be changed and saved. The configuration of the networks or controller software cannot be influenced.
NEFC-M12G5-0.3-U1G5 PC Drive Interfaces Operating system
IBM-compatible CD-ROM USB port (specification USB 1.1 or higher) Microsoft Windows 2000 or XP Configuration and parameterisation Reading out of system, module, channel diagnostics and error trace Saving of the configuration as a project Integration of plug-ins/links to self-executing programs
Functional range
Scope of delivery Type of mounting Electrical connection Adapter cable composition Cable length Protection class to EN 60529 CE mark (see declaration of conformity) Ambient temperature Material Housing Cable sheath Pin contact Note on materials
2018/04 – Subject to change and archived directly as a CPX-FMT project. Undocumented changes can subsequently be identified using the online/offline comparison function. On-site tests such as the actuation of valves or the emulation of sensor feedback (in both cases called “forcing”), for example, can be
[m]
[°C]
Adapter M12, 5-pin to mini USB socket CD-ROM with installation program Screw-in Plug M12x1, 5-pin 4 x 0.34 mm2 0.3 IP20 To EU EMC Directive –5 … +50 ABS PUR Gold-plated brass RoHS-compliant
è Internet: www.festo.com/catalogue/...
57
Page 58
Terminal CPX Technical data – CPX Maintenance Tool Display components Creating a device configuration using the editor 1
2
The device configuration can be con veniently generated, parameterised and saved using the drag & drop feature. You can insert and move modules. 1 Module numbers from the graphic system overview 2 Catalogue for selecting required modules
Module overview for a selected module Displays important module data as well as the number of allocated inputs and outputs.
Diagnostic memory Faults which occur during operation are entered in a diagnostic memory. The first or the last 40 entries are saved, as well as the respective time measured from the moment the power supply was switched on.
58
è Internet: www.festo.com/catalogue/...
Subject to change – 2018/04
Page 59
Terminal CPX Technical data – CPX Maintenance Tool Download CAD data è www.festo.com
Dimensions Adapter
1 Mini B 5P USB port 2 Plug M12x1, 5-pin
Ordering data Designation CPX Maintenance Tool (CPX-FMT), software and USB-to-M12 adapter
2018/04 – Subject to change
Part No.
Type
547432
NEFC-M12G5-0.3-U1G5
è Internet: www.festo.com/catalogue/...
59
Page 60
Terminal CPX Technical data – Control block CPX-CEC
Industrial Ethernet Modbus/TCP EasyIP IT services: Web E-mail File transfer
The CODESYS controller is a modern control system for CPX terminals that enables programming with CODESYS to IEC 61131-3. The power supply to and communica tion with other modules takes place via the interlinking block. In addition to network connections, LEDs are also provided for the bus status, operating status of the PLC and CPX peripherals information, as are switching elements and a diagnostic interface for CPX-MMI and CPX-FMT.
Application Bus connection The CPX-CEC is a remote controller that can be connected to a master PLC via the fieldbus nodes of the CPX terminal or via Ethernet. At the same
Communication protocols
Operating modes time, it is possible to operate the CPX-CEC as a compact stand-alone controller directly on the machine.
Fieldbus via CPX fieldbus nodes Modbus/TCP EasyIP
Stand-alone Remote controller, fieldbus Remote controller, Ethernet
For the CPX-MMI/-FMT Ethernet interface for IT applications Remote diagnostics
The operating mode and fieldbus protocol are set using the DIL switch on the CPX-CEC.
The integrated web server offers a convenient means of querying data saved in the CPX-CEC.
Actuation of decentralised installa tion systems on the basis of CPI actuation of applications in proportional pneumatics AS-Interface actuation via gateway
Connection to all fieldbuses as a remote controller and for pre-pro cessing Actuation of electric drives as individual axes via CANopen (CPX-CEC-C1/-M1)
Early warnings and visualisation options Closed-loop pneumatic applications
Setting options The CPX-CEC has the following inter faces for monitoring, programming and commissioning:
Features Easy actuation of valve terminal configurations with MPA, VTSA Diagnostics with flexible monitoring options for pressure, flow rate, cylinder operating time, air consumption
60
è Internet: www.festo.com/catalogue/...
Subject to change – 2018/04