Page 111

Terminal CPX Accessories – Bus node CPX-FB37 Ordering data Description

Part No.

Type

EtherCAT bus node

2735960

CPX-FB37

Plug connector M12x1, 4-pin, D-coded

543109

NECU-M-S-D12G4-C2-ET

8040446 8040447 8040448 8040449 8040450 8040451 8040452 8040453 8040454 8040456 548757

NEBC-D12G4-ES-0.5-S-D12G4-ET NEBC-D12G4-ES-1-S-D12G4-ET NEBC-D12G4-ES-3-S-D12G4-ET NEBC-D12G4-ES-5-S-D12G4-ET NEBC-D12G4-ES-10-S-D12G4-ET NEBC-D12G4-ES-1-S-R3G4-ET NEBC-D12G4-ES-3-S-R3G4-ET NEBC-D12G4-ES-5-S-R3G4-ET NEBC-D12G4-ES-10-S-R3G4-ET NEBC-LE4-ES-5-D12G4-ET CPX-AK-P

Inspection cover, transparent

533334

AK-SUB-9/15-B

Cover cap for sealing unused bus connections (10 pieces)

165592

ISK-M12

Inscription label holder for connection block

536593

CPX-ST-1

5-pin M12 adapter for mini USB socket and controller software

547432

NEFC-M12G5-0.3-U1G5

8029674 8029675 8029676 8029677 8029678 8029679

P.BE-CPX-FB37-DE P.BE-CPX-FB37-EN P.BE-CPX-FB37-ES P.BE-CPX-FB37-FR P.BE-CPX-FB37-IT P.BE-CPX-FB37-ZH

Bus node

Bus connection

Connecting cable, straight plug, M12x1, 4-pin, D-coded

Straight plug, M12x1, 4-pin, D-coded

Straight plug, RJ45, 8-pin

Open end, 4-wire Transparent cover for DIL switch and memory card

0.5 m 1m 3m 5m 10 m 1m 3m 5m 10 m 5m

User documentation Electronics manual, CPX bus node, type CPX-FB37

2018/04 – Subject to change

German English Spanish French Italian Chinese

è Internet: www.festo.com/catalogue/...

111

Page 112

Terminal CPX Technical data – Bus node CPX-FB38 Bus node for operating the CPX valve terminal on EtherCAT. The bus node is provided with system supply via the interlinking block and processes communication with the I/O modules. The status of the CPX terminal is displayed as a common message via four CPX-specific LEDs. The fieldbus communication status is displayed via four bus-specific LEDs.

Application Bus connection The bus connection is established via two M12 sockets, D-coded to IEC61076-2-101 with IP65, IP67 protection.

Both connections are equivalent 100BaseTX Ethernet ports with integrated auto MDI functionality

(cross-over and patch cables can be used) that are brought together via an internal switch.

Maximum segment length 100 m Transmission rate 100 Mbit/s actuators or robot controllers, PLCs or process equipment. In addition, non-real-time critical information such as diagnostic information, configuration information, etc. can be transferred.

The data bandwidth is sufficient to transmit both data types (real-time and non-real-time) in parallel.

a diagnostic interface. The bus node can be used as a remote I/O or remote controller. All information relevant to the CPX can be read out and, depend­ ent on the function, changed via an MMI/FMT.

EtherCAT implementation The CPX-FB38 supports the EtherCAT protocol based on the Ethernet standard and the TCP/IP technology to IEEE802.3. This guarantees a data exchange with a high data transmission rate, for example I/O data from sensors,

The bus node features LEDs for bus status and CPX peripheral information as well as switch elements and

Special points in combination with CPX-CEC When a bus node is combined with a control block (CPX-CEC, in the fieldbus remote controller operating mode), the connected I/Os and/or valves, sensors and actuators are controlled via the CPX control block.

In this case, the bus node only provides the communication interface to the PLC. Communication between the control block and CPX bus node is established

112

è Internet: www.festo.com/catalogue/...

via the interlinking of the CPX modules and occupies an address capacity of the CPX system of: 8 byte outputs 8 byte inputs

The remaining address capacity of the control block or CPX system for actuating the peripherals is: 56 byte inputs 56 byte outputs

Subject to change – 2018/04

Page 113

Terminal CPX Technical data – Bus node CPX-FB38 General technical data Type Fieldbus interface Baud rate Max. address capacity, inputs Max. address capacity, outputs LED displays

CPX-FB38 [Mbit/s] [byte] [byte] (bus-specific)

(product-specific)

Channel and module-oriented diagnostics Undervoltage of modules Diagnostic memory XML file System parameters Diagnostic behaviour Signal setup Fail-safe response Forcing of channels

Device-specific diagnostics

Configuration support Parameterisation

Additional functions Control elements Operating voltage

Current consumption Protection class to EN 60529 Temperature range

Nominal value Permissible range Power failure buffering

[V DC] [V DC] [ms] [mA]

Operation Storage/transport Housing

[°C] [°C]

Materials Grid dimension Dimensions (incl. interlinking block) W x L x H Weight

-H- Note

-H- Note

Please observe the general limits and guidelines for the system when configuring the electrical modules.

Always use screws appropriate to the interlinking block (metal or plastic):

2018/04 – Subject to change

2x M12x1 socket, 4-pin, D-coded 100 64 64 Error = Communication error L/A1 = Network active port 1 L/A2 = Network active port 2 Run = Communication status M = Modify, parameterisation PL = Load supply PS = Electronic supply, sensor supply SF = System fault

[mm] [mm] [g]

System status can be represented using process data Additional diagnostic interface for operator units DIL switch 24 18 … 30 10 Typically 100 IP65, IP67 –5 … +50 –20 … +70 Reinforced PA 50 50 x 107 x 50 125

Self-tapping screws for plastic interlinking blocks

è Internet: www.festo.com/catalogue/...

Screws with metric thread for metal interlinking blocks

113

Page 114

Terminal CPX Technical data – Bus node CPX-FB38 Connection and display components

2

1

1 Bus-specific status LEDs 2 CPX-specific status LEDs 3 Fieldbus connection, output (4-pin socket M12x1, D-coded) 4 Fieldbus connection, input (4-pin socket M12x1, D-coded) 5 Transparent DIL switch cover

3

5

4

Pin allocation for the fieldbus interface Pin allocation

Pin

Signal

Designation

1

TD+

Transmitted data+

2

RD+

Received data+

3

TD-

Transmitted data-

4

RD-

Received data-

M12x1 socket, D-coded

Housing

114

Screened

è Internet: www.festo.com/catalogue/...

Subject to change – 2018/04

Page 115

Terminal CPX Accessories – Bus node CPX-FB38 Ordering data Designation

Part No.

Type

EtherCAT bus node

552046

CPX-FB38

M12x1 plug, 4-pin, D-coded

543109

NECU-M-S-D12G4-C2-ET

8040446 8040447 8040448 8040449 8040450 8040451 8040452 8040453 8040454 8040456 548757

NEBC-D12G4-ES-0.5-S-D12G4-ET NEBC-D12G4-ES-1-S-D12G4-ET NEBC-D12G4-ES-3-S-D12G4-ET NEBC-D12G4-ES-5-S-D12G4-ET NEBC-D12G4-ES-10-S-D12G4-ET NEBC-D12G4-ES-1-S-R3G4-ET NEBC-D12G4-ES-3-S-R3G4-ET NEBC-D12G4-ES-5-S-R3G4-ET NEBC-D12G4-ES-10-S-R3G4-ET NEBC-LE4-ES-5-D12G4-ET CPX-AK-P

Inspection cover, transparent

533334

AK-SUB-9/15-B

Cover cap for sealing unused bus connections (10 pieces)

165592

ISK-M12

Inscription label holder for connection block

536593

CPX-ST-1

Adapter from 5-pin M12 to mini USB socket and controller software

547432

NEFC-M12G5-0.3-U1G5

562524 562525 562526 562527 562528

P.BE-CPX-FB38-DE P.BE-CPX-FB38-EN P.BE-CPX-FB38-ES P.BE-CPX-FB38-FR P.BE-CPX-FB38-IT

Bus node

Bus connection

Connecting cable, straight plug, M12x1, 4-pin, D-coded

Straight plug, M12x1, 4-pin, D-coded

Straight plug, RJ45, 8-pin

Open end, 4-wire Transparent cover for DIL switch and memory card

0.5 m 1m 3m 5m 10 m 1m 3m 5m 10 m 5m

User manual Electronics manual, CPX bus node, type CPX-FB38

2018/04 – Subject to change

German English Spanish French Italian

è Internet: www.festo.com/catalogue/...

115

Page 116

Terminal CPX Technical data – Bus node CPX-FB39 Bus node for handling communication between the electrical CPX terminal and the Sercos III network. The bus node is provided with system supply via the interlinking block and processes communication with the I/O modules. The status of the CPX terminal is displayed as a common message via 4 CPX-specific LEDs.

Sercos IT services: Web

Application Bus connection The bus connection is established via two M12x1 plug connectors, D-coded to IEC947-5-2 with degree of protec­ tion to IP65, IP67. The connections are equipped with automatic detec­ tion for the incoming and outgoing connection.

The Sercos III bus node can be used to connect the CPX valve terminal to the standardised Sercos III bus. Sercos II uses the Ethernet standard (IEEE802.3) and TCP/IP technology for communication in an industrial environment. Industry-compatible Sercos III devices enable data to be exchanged with a higher data transmission rate, such as data from sensors, actuators or controllers. You can also transmit information that is not real-time critical, such as diagnostics or configuration information.

technologies. An integrated web server enables diagnostic data to be visualised via HTML. Various programs support direct access to the device data from the automation network.

The CPX-FB39 supports the operating modes remote I/O and remote controller. In remote I/O operating mode, all functions of the CPX valve terminal are directly controlled by the Sercos controller.

When a bus node is combined with a control block (CPX-CEC, in the fieldbus remote controller operating mode), the connected I/Os and/or valves, sensors and actuators are controlled via the CPX control block. In this case, the bus node only provides the communication interface to the PLC. Communication between the control block and CPX bus node takes place by interlinking the CPX modules and takes up the following address capacity in the CPX system:

8/16 byte outputs 8/16 byte inputs The following address capacity remains in the control block or CPX system for activating the peripherals: 56/48 byte inputs 56/48 byte outputs

116

è Internet: www.festo.com/catalogue/...

Web servers In addition to activation via a bus system, it is possible to use IT Points to note in connection with CPX-CEC

Subject to change – 2018/04

Page 117

Terminal CPX Technical data – Bus node CPX-FB39 General technical data Type Fieldbus interface Baud rates Protocol Max. address capacity LED displays

CPX-FB39 [Mbps] Inputs Outputs Bus-specific

[byte] [byte]

Product-specific

Device-specific diagnostics

Configuration support Parameterisation

Additional functions

Control elements Operating voltage

Nominal value Permissible range Current consumption (at nominal voltage, without MMI) Degree of protection to EN 60529 Temperature range Operation Storage/transport Materials Note on materials Grid dimension Dimensions (incl. interlinking block) W x L x H Product weight

[V DC] [V DC] [mA] [°C] [°C]

[mm] [mm] [g]

2x M12x1 socket, D-coded, 4-pin 100 full/half duplex Sercos III 64 64 S = Sercos LED SD = Sercos sub-device LED TP1 = Network active port 1 TP2 = Network active port 2 M = Modify, parameterisation PL = Load supply PS = Electronics supply, sensor supply SF = System fault Module and channel-oriented diagnostics Undervoltage of modules Diagnostic memory SDDML file Diagnostic behaviour Fallback output data Forcing of channels Signal setup System parameters Acyclic and cyclic data access via Sercos IP addressing via Sercos parameters or operator unit Channel-oriented diagnostics via fieldbus Start-up parameterisation in plain text via fieldbus System status can be displayed using process data Additional diagnostic interface for operator units DIL switches 24 18 … 30 Typically 100 IP65, IP67 – 5 … +50 –20 … +70 PA reinforced RoHS compliant 50 50 x 107 x 50 125

-H- Note Please observe the general limits and guidelines for the system when configuring the electrical modules.

2018/04 – Subject to change

è Internet: www.festo.com/catalogue/...

117

Page 118

Terminal CPX Technical data – Bus node CPX-FB39 Connection and display components 3

1

1 Service interface for operator unit CPX-MMI or PC with CPX maintenance tool NEFC-M12G5-0.3-U1G5 2 Transparent DIL switch cover 3 Status LED, bus-specific and CPX-specific 4 Fieldbus connection (M12x1 socket, 4-pin, D-coded)

4

2

4

Pin allocation for the fieldbus interface Terminal allocation

Pin

Signal

Designation

1

TD+

Transmitted data+

2

RD+

Received data+

3

TD-

Transmitted data-

4

RD-

Received data-

Hous­ ing

FE

Screening

M12x1 socket, D-coded

118

è Internet: www.festo.com/catalogue/...

-H- Note The CPX­FB39 has the capability for auto­ matic detection of transmit and receive cables (Auto­MDI/MDI­X Auto­Crossover). RD and TD signal pairs are automatically swapped if required.

Subject to change – 2018/04

Page 119

Terminal CPX Accessories – Bus node CPX-FB39 Ordering data Description

Part No.

Type

Ethernet Sercos III bus node

2093101

CPX-FB39

Plug connector M12x1, 4-pin, D-coded

543109

NECU-M-S-D12G4-C2-ET

8040446 8040447 8040448 8040449 8040450 8040451 8040452 8040453 8040454 8040456 548757

NEBC-D12G4-ES-0.5-S-D12G4-ET NEBC-D12G4-ES-1-S-D12G4-ET NEBC-D12G4-ES-3-S-D12G4-ET NEBC-D12G4-ES-5-S-D12G4-ET NEBC-D12G4-ES-10-S-D12G4-ET NEBC-D12G4-ES-1-S-R3G4-ET NEBC-D12G4-ES-3-S-R3G4-ET NEBC-D12G4-ES-5-S-R3G4-ET NEBC-D12G4-ES-10-S-R3G4-ET NEBC-LE4-ES-5-D12G4-ET CPX-AK-P

Inspection cover, transparent

533334

AK-SUB-9/15-B

Cover cap for sealing unused bus connections (10 pieces)

165592

ISK-M12

Inscription label holder for connection block

536593

CPX-ST-1

5-pin M12 to mini USB socket adapter and controller software

547432

NEFC-M12G5-0.3-U1G5

8028632 8028633 8028634 8028635 8028636 8028637

P.BE-CPX-FB39-DE P.BE-CPX-FB39-EN P.BE-CPX-FB39-ES P.BE-CPX-FB39-FR P.BE-CPX-FB39-IT P.BE-CPX-FB39-ZH

Bus node

Bus connection

Connecting cable, straight plug, M12x1, 4-pin, D-coded

Straight plug, M12x1, 4-pin, D-coded

Straight plug, RJ45, 8-pin

Open end, 4-wire Transparent cover for DIL switch and memory card

0.5 m 1m 3m 5m 10 m 1m 3m 5m 10 m 5m

User Documentation User Documentation for bus node CPX-FB39

2018/04 – Subject to change

German English Spanish French Italian Chinese

è Internet: www.festo.com/catalogue/...

119

Page 120

Terminal CPX Technical data – Bus node CPX-FB40 Bus node for handling communication between the electrical CPX terminal and the Ethernet POWERLINK network. The bus node is provided with system supply via the interlinking block and processes communication with the I/O modules. The status of the CPX terminal is displayed as a common message via 4 CPX-specific LEDs.

Ethernet POWERLINK IT services: Web

Application Bus connection The bus connection is established via an M12x1 plug connector, D-coded to IEC947-5-2 with degree of protection to IP65, IP67.

Ethernet POWERLINK uses the Ethernet standards and TCP/IP techno­ logy (IEEE802.3) for communication in an industrial environment and integ­ rates all CANopen mechanisms. It includes all the key features of standard Ethernet, including internode communication, hotplug capability and free selection of network topology. Ethernet POWERLINK fulfils the realtime requirements using a mix of timeslot and polling procedures. In other words, defined times are reserved on the Ethernet lines exclusively for transferring real-time data. Only network participants which have previously been polled by the controller are able to transmit data during these timeslots.

directly controlled by the Ethernet POWERLINK master (host). In addition to activation via a bus sys­ tem, it is possible to use IT technolo­ gies. An integrated web server enables diagnostic data to be visualised via HTML. Various programs support direct access to the device data from the automation network.

The Ethernet POWERLINK node for CPX supports the transmission technology that conforms to DIN EN 50173/CAT 5 as an integrated interface.

When a bus node is combined with a control block (CPX-CEC, in the fieldbus remote controller operating mode), the connected I/Os and/or valves, sensors and actuators are controlled via the CPX control block.

In this case, the bus node only provides the communication interface to the PLC. Communication between the control block and CPX bus node takes place by interlinking the CPX modules and takes up the following address capacity in the CPX system: 8 byte outputs 8 byte inputs

The following address capacity remains in the control block or CPX system for activating the peripherals: 56 byte inputs 56 byte outputs

120

è Internet: www.festo.com/catalogue/...

Ethernet POWERLINK implementation The CPX-FB40 supports the two oper­ ating modes: remote I/O and remote controller. In remote I/O operating mode, all functions of the CPX valve terminal are Points to note in connection with CPX-CEC

Subject to change – 2018/04