Page 191
Terminal CPX Technical data – Analogue module for inputs General technical data Type
CPX-2AE-U-I
Electrical isolation
Channel – channel Channel – internal bus Group diagnostics Channel diagnostics
LED displays
Diagnostics
Parameterisation
Protection class to EN 60529 Temperature range
Operation Storage/transport
Materials Note on materials Grid dimension Dimensions (incl. interlinking block and connection block) W x L x H Product weight
[°C] [°C]
[mm] [mm] [g]
CPX-4AE-U-I
No Yes, with external sensor supply 1 Via flashing frequency of 4 group diagnostics Wire break per channel Limit value violation per channel Parameterisation error Short circuit, input signal Overload at input – Overflow/underflow – Short circuit in sensor supply Data format Forces per channel Limit value monitoring per channel Measured value smoothing Signal range per channel Wire break monitoring per channel Behaviour after short circuit – Behaviour after overload at input – Sensor supply active Depending on connection block –5 … +50 –20 … +70 Reinforced PA, PC – RoHS-compliant 50 50 x 107 x 50 38 46
CPX-4AE-I
Via flashing frequency of group diagnostics
Short circuit, input signal – –
– –
–
38
Internal structure, basic representation 24 V ± 25% (UEL/SEN-)
24 VSEN
4
1 3
5
2
Inputx+ Inputx-
6 0 V (UEL/SEN-)
0 VSEN FE 7
2018/04 – Subject to change
1 Diagnostics 2 Inputx (PLC/IPC via fieldbus) 3 Logic 4 Monitoring/disconnection of the sensor supply 5 D/A conversion 6 Error LED (red, module error) 7 Connections on the connection block
è Internet: www.festo.com/catalogue/...
191
Page 192
Terminal CPX Technical data – Analogue module for inputs Connection and display components CPX-2AE-U-I and CPX-4AE-I 1
CPX-4AE-U-I 1 Error LED (red, module error)
1
1 Error LED (red, module error) 2 Channel-related error LEDs (red)
1 Connection block/analogue module combinations Connection blocks Part No. CPX-AB-4-M12X2-5POL CPX-AB-4-M12X2-5POL-R CPX-AB-8-KL-4POL CPX-AB-1-SUB-BU-25POL CPX-M-AB-4-M12X2-5POL
195704 541254 195708 525676 549367
Pin allocation Connection block inputs
CPX-2AE-U-I
Analogue module CPX-2AE-U-I
CPX-4AE-U-I n n n n n
CPX-4AE-I n n n n n
CPX-4AE-U-I n n n n n
CPX-4AE-I
CPX-AB-4-M12X2-5POL, CPX-AB-4-M12X2-5POL-R1) and CPX-M-AB-4-M12X2-5POL X1.1: 24 VSEN X3.1: 24 VSEN X1.1: X1.2: Input U0+ X3.2: Input U1+ X1.2: X1.3: 0 VSEN X3.3: 0 VSEN X1.3: X1.4: Input U0– X3.4: Input U1– X1.4: X1.5: FE2) X3.5: FE2) X1.5:
24 VSEN Input 0+ 0 VSEN Input 0– FE2)
X3.1: X3.2: X3.3: X3.4: X3.5:
24 VSEN Input 2+ 0 VSEN Input 2– FE2)
X1.1: X1.2: X1.3: X1.4: X1.5:
24 VSEN Input I0+ 0 VSEN Input I0– FE2)
X3.1: X3.2: X3.3: X3.4: X3.5:
24 VSEN Input I2+ 0 VSEN Input I2– FE2)
X2.1: X2.2: X2.3: X2.4: X2.5:
24 VSEN Input I0+ 0 VSEN Input I0– FE2)
X4.1: X4.2: X4.3: X4.4: X4.5:
24 VSEN Input I1+ 0 VSEN Input I1– FE2)
X2.1: X2.2: X2.3: X2.4: X2.5:
24 VSEN Input 1+ 0 VSEN Input 1– FE2)
X4.1: X4.2: X4.3: X4.4: X4.5:
24 VSEN Input 3+ 0 VSEN Input 3– FE2)
X2.1: X2.2: X2.3: X2.4: X2.5:
24 VSEN Input I1+ 0 VSEN Input I1– FE2)
X4.1: X4.2: X4.3: X4.4: X4.5:
24 VSEN Input I3+ 0 VSEN Input I3– FE2)
X1.0: X1.1: X1.2: X1.3:
24 VSEN 0 VSEN Input U0– FE
X5.0: X5.1: X5.2: X5.3:
24 VSEN 0 VSEN Input U1– FE
X1.0: X1.1: X1.2: X1.3:
24 VSEN 0 VSEN Input 0– FE
X5.0: X5.1: X5.2: X5.3:
24 VSEN 0 VSEN Input 2– FE
X1.0: X1.1: X1.2: X1.3:
24 VSEN 0 VSEN Input I0– FE
X5.0: X5.1: X5.2: X5.3:
24 VSEN 0 VSEN Input I2– FE
X2.0: X2.1: X2.2: X2.3:
n.c. n.c. Input U0+ FE
X6.0: X6.1: X6.2: X6.3:
n.c. n.c. Input U1+ FE
X2.0: X2.1: X2.2: X2.3:
n.c. n.c. Input 0+ FE
X6.0: X6.1: X6.2: X6.3:
n.c. n.c. Input 2+ FE
X2.0: X2.1: X2.2: X2.3:
n.c. n.c. Input I0+ FE
X6.0: X6.1: X6.2: X6.3:
n.c. n.c. Input I2+ FE
X3.0: X3.1: X3.2: X3.3:
24 VSEN 0 VSEN Input I0– FE
X7.0: X7.1: X7.2: X7.3:
24 VSEN 0 VSEN Input I1– FE
X3.0: X3.1: X3.2: X3.3:
24 VSEN 0 VSEN Input 1– FE
X7.0: X7.1: X7.2: X7.3:
24 VSEN 0 VSEN Input 3– FE
X3.0: X3.1: X3.2: X3.3:
24 VSEN 0 VSEN Input I1– FE
X7.0: X7.1: X7.2: X7.3:
24 VSEN 0 VSEN Input I3– FE
X4.0: X4.1: X4.2: X4.3:
n.c. n.c. Input I0+ FE
X8.0: X8.1: X8.2: X8.3:
n.c. n.c. Input I1+ FE
X4.0: X4.1: X4.2: X4.3:
n.c. n.c. Input 1+ FE
X8.0: X8.1: X8.2: X8.3:
n.c. n.c. Input 3+ FE
X4.0: X4.1: X4.2: X4.3:
n.c. n.c. Input I1+ FE
X8.0: X8.1: X8.2: X8.3:
n.c. n.c. Input I3+ FE
CPX-AB-8-KL-4POL
1) 2)
Speedcon quick lock, shield additionally on metal thread FE/shield additionally on metal thread
192
è Internet: www.festo.com/catalogue/...
Subject to change – 2018/04
Page 193
Terminal CPX Technical data – Analogue module for inputs Pin allocation Connection block inputs
CPX-2AE-U-I
CPX-4AE-U-I
CPX-4AE-I
CPX-AB-1-SUB-BU-25POL 1: 2: 3: 4: 5: 6: 7: 8: 9: 10: 11: 12: 13: 1)
Input U0– Input U0+ Input I0– Input I1+ n.c. n.c. n.c. n.c. 24 VSEN 24 VSEN 0 VSEN 0 VSEN Shield1)
14: Input U1– 15: Input U1+ 16: Input I1– 17: Input I1+ 18: 24 VSEN 19: n.c. 20: 24 VSEN 21: n.c. 22: 0 VSEN 23: 0 VSEN 24: 0 VSEN 25: FE Housing: FE
1: 2: 3: 4: 5: 6: 7: 8: 9: 10: 11: 12: 13:
Input 0– Input 0+ Input 1– Input 1+ n.c. n.c. n.c. n.c. 24 VSEN 24 VSEN 0 VSEN 0 VSEN Shield1)
14: Input 2– 15: Input 2+ 16: Input 3– 17: Input 3+ 18: 24 VSEN 19: n.c. 20: 24 VSEN 21: n.c. 22: 0 VSEN 23: 0 VSEN 24: 0 VSEN 25: FE Housing: FE
1: 2: 3: 4: 5: 6: 7: 8: 9: 10: 11: 12: 13:
Input I0– Input I0+ Input I1– Input I1+ n.c. n.c. n.c. n.c. 24 VSEN 24 VSEN 0 VSEN 0 VSEN Shield1)
14: Input I2– 15: Input I2+ 16: Input I3– 17: Input I3+ 18: 24 VSEN 19: n.c. 20: 24 VSEN 21: n.c. 22: 0 VSEN 23: 0 VSEN 24: 0 VSEN 25: FE Housing: FE
Connect shield to functional earth FE
2018/04 – Subject to change
è Internet: www.festo.com/catalogue/...
193
Page 194
Terminal CPX Accessories – Analogue module for inputs Ordering data Part No.
Type
Input module, analogue 2 analogue current or voltage inputs
526168
CPX-2AE-U-I
4 analogue current or voltage inputs
573710
CPX-4AE-U-I
4 analogue current inputs
541484
CPX-4AE-I
195704 541254 195708 525676 549367
CPX-AB-4-M12X2-5POL CPX-AB-4-M12X2-5POL-R CPX-AB-8-KL-4POL CPX-AB-1-SUB-BU-25POL CPX-M-AB-4-M12X2-5POL
Plug, M12, 5 pin
175487
SEA-M12-5GS-PG7
Plug, Sub-D, 25-pin
527522
SD-SUB-D-ST25
Cover for CPX-AB-8-KL-4POL (IP65, IP67) – 8 cable through-feeds M9 – 1 cable through-feed for multi-pin plug
538219
AK-8KL
Fittings kit
538220
VG-K-M9
Screening plate for M12 connections
526184
CPX-AB-S-4-M12
526415 526416 526417 526418 526419
P.BE-CPX-AX-DE P.BE-CPX-AX-EN P.BE-CPX-AX-ES P.BE-CPX-AX-FR P.BE-CPX-AX-IT
Connection block Plastic
4x socket, M12, 5-pin 4x socket, M12 with quick-lock technology, 5-pin Spring-loaded terminal, 32-pin 1x socket, Sub-D, 25-pin 4x socket, M12, 5-pin
Metal Plug
Cover
Screening plate
Manual Manual
194
German English Spanish French Italian
è Internet: www.festo.com/catalogue/...
Subject to change – 2018/04
Page 195
Terminal CPX Technical data – Analogue input module with pressure sensors Function The pressure input modules enable a maximum of four pressures to be processed. The internal measured value of the sensor (analogue value with 10 bit resolution) is converted into an internal numerical format as appropriate to the parameterisation and made available to the bus node as an image table. It is also possible to combine two channels into one differential pressure channel.
Applications Measuring range 0 … 10 bar or –1 … +1 bar Choice of units of measurement Processing of max. four pressures per module Pressure indication via LCD display Direct connection via QS4 push-in connectors Error message via CPX Channel-oriented diagnostics
General technical data Type
CPX-4AE-P-B2
No. of analogue inputs Pneumatic connection Nominal operating voltage Operating voltage range Intrinsic current consumption Measured variable Displayable units
Pressure measuring range
[V DC] [V DC] [mA]
Starting value Final value
Internal cycle time Data format
[bar] [bar] [ms]
LED displays Diagnostics
Parameterisation
Protection class to EN 60529 Operating medium Note on operating/pilot medium Ambient temperature Storage temperature Temperature of medium Note on materials Materials Grid dimension Dimensions (incl. interlinking block) W x L x H Weight
[°C] [°C] [°C]
[mm] [mm] [g]
CPX-4AE-P-D10
4 QS-4 24 18…30 Typically 50 4x relative or 2x differential pressure measurement kPa mbar psi –1 0 1 10 5 15 bits + prefix Binary representation in mbar, kPa, psi Group diagnostics Limit value violation per channel Parameterisation error Sensor limit per channel Diagnostic delay per channel Hysteresis per module Unit of measurement Measured value smoothing per channel Limit value monitoring per channel Sensor limit per channel Measurement of relative/differential pressure IP65, IP67 Compressed air in accordance with ISO 85731:2010 [7:4:4] Operation with lubricated medium possible (in which case lubricated opera tion will always be required) –5 … 50 –20 … 70 0 … 50 RoHS-compliant Reinforced PA, PC 50 50 x 107 x 55 112
-H- Note Extreme pneumatic conditions, for example high cycle frequency with large pressure amplitudes, can damage the sensors. 2018/04 – Subject to change
è Internet: www.festo.com/catalogue/...
195
Page 196
Terminal CPX Accessories – Analogue input module with pressure sensors Connection and display components 1 2
1 Error LED (red, module error) 2 LCD display with permanent dis play of the four measured pres sures, unit of measurement and if applicable limit value violation 3 QS connections
3
Ordering data Designation
Part No.
Type
Input module, analogue 4 analogue pressure inputs, pressure range –1 … +1 bar
560361
CPX-4AE-P-B2
4 analogue pressure inputs, pressure range 0 … 10 bar
560362
CPX-4AE-P-D10
Inscription labels 6x10, 64 pieces, in frames
18576
IBS-6x10
526415 526416 526417 526418 526419
P.BE-CPX-AX-DE P.BE-CPX-AX-EN P.BE-CPX-AX-ES P.BE-CPX-AX-FR P.BE-CPX-AX-IT
Inscription labels
User manual User manual
196
German English Spanish French Italian
è Internet: www.festo.com/catalogue/...
Subject to change – 2018/04
Page 197
Terminal CPX Technical data – Analogue module for temperature inputs Function The CPX-PT100 analogue input mod ule with 4 channels for temperature measurement enables the connection of up to 4 temperature sensors of the type PT100-PT1000, Ni100-Ni1000, etc. The temperature module supports various connection concepts with dif ferent numbers of sockets or terminals as appropriate to the connection block selected.
Applications Temperature module for tempera ture sensors PT100, PT200, PT500, PT1000, Ni100, Ni120, Ni500, Ni1000 Supports connection blocks with M12, Harax and terminal connection Temperature module features can be parameterised 2-wire, 3-wire and 4-wire connection The temperature module is provided with voltage supply for the electronics and the sensors via the interlinking block Temperature module protection and diagnostics through integrated electronic fuse protection
General technical data Type
CPX-4AE-T Temperature input
No. of analogue inputs Max. power supply per module Fuse protection Current consumption from 24 V sensor supply (quiescent current) Supply voltage of sensors Sensor type (parameterisable for each channel by means of DIL switch) Temperature range
[A] [mA] [V DC]
Pt standard Pt climatic Ni
[°C] [°C] [°C]
Sensor connection technology Resolution Operating error limit relative to input range Basic error limit (25 °C) Standard Pt climatic Temperature errors relative to input range Linearity errors (no software scaling) Repetition accuracy (at 25 °C) Max. line resistance per wire Max. permissible input voltage Cycle time (module)
[%] [K] [K] [%] [%] [%] [Ω] [V] [ms]
2018/04 – Subject to change
Choice of 2 or 4 0.7 Internal electronic fuse for sensor supply Typically 50 24 ±25% PT100, PT200, PT500, PT1000 Ni100, Ni120, Ni500, Ni1000 –200 … +850 –120 … +130 –60 … +180 2-wire, 3-wire and 4-wire technology 15 bit + prefix ±0.06 ±0.6 ±0.2 ±0.001 ±0.02 ±0.05 10 ±30 250
è Internet: www.festo.com/catalogue/...
197
Page 198
Terminal CPX Technical data – Analogue module for temperature inputs General technical data Data format Cable length Electrical isolation
[m] Channel – channel Channel – internal bus Group diagnostics Channel diagnostics
LED displays Diagnostics
Parameterisation
Protection class to EN 60529 Temperature range
Operation Storage/transport
Materials Grid dimension Dimensions (incl. interlinking block and connection block) W x L x H Weight
[°C] [°C] [mm] [mm] [g]
15 bit + prefix, complement of two, binary notation in tenths of a degree Max. 200 (screened) No Yes 1 4 Short circuit/overload, channel Parameterisation error Value falling below nominal range/full-scale value Value exceeding nominal range/full-scale value Wire break Unit of measurement and interference frequency suppression Diagnostic message in the event of a wire break or short circuit Limit monitoring per channel Sensor connection technology Sensor type/temperature coefficient, temperature range Limit value per channel Measured value smoothing Depending on connection block –5 … +50 –20 … +70 Reinforced PA, PC 50 50 x 107 x 50 38
Connection and display components CPX-4AE-T 1
1 Error LED (red, module error) 2 Channel-specific error LEDs (red)
4 AI-T
1 Connection block/analogue module combinations Connection blocks Part No. CPX-AB-4-M12X2-5POL CPX-AB-4-M12X2-5POL-R CPX-AB-8-KL-4POL CPX-AB-4-HAR-4POL CPX-M-AB-4-M12X2-5POL
198
195704 541254 195708 525636 549367
è Internet: www.festo.com/catalogue/...
Temperature module CPX-4AE-T n n n n n
Subject to change – 2018/04
Page 199
Terminal CPX Technical data – Analogue module for temperature inputs Pin allocation Connection block inputs
CPX-4AE-T
CPX-AB-4-M12X2-5POL, CPX-AB-4-M12X2-5POL-R1) and CPX-M-AB-4-M12X2-5POL X1.1: Input I0+ X1.2: Input U0+ X1.3: Input I0– X1.4: Input U0– X1.5: FE2)
X3.1: X3.2: X3.3: X3.4: X3.5:
Input I2+ Input U2+ Input I2– Input U2– FE2)
X2.1: X2.2: X2.3: X2.4: X2.5:
Input I1+ Input U1+ Input I1– Input U1– FE2)
X4.1: X4.2: X4.3: X4.4: X4.5:
Input I3+ Input U3+ Input I3– Input U3– FE2)
X1.0: X1.1: X1.2: X1.3:
Input I0+ Input I0– Input U0– FE
X5.0: X5.1: X5.2: X5.3:
Input I2+ Input I2– Input U2– FE
X2.0: X2.1: X2.2: X2.3:
n.c. n.c. Input U0+ FE
X6.0: X6.1: X6.2: X6.3:
n.c. n.c. InputUI2+ FE
X3.0: X3.1: X3.2: X3.3:
Input I1+ Input I1– Input U1– FE
X7.0: X7.1: X7.2: X7.3:
Input I3+ Input I3– Input U3– FE
X4.0: X4.1: X4.2: X4.3:
n.c. n.c. Input U1+ FE
X8.0: X8.1: X8.2: X8.3:
n.c. n.c. Input U3+ FE
X1.1: X1.2: X1.3: X1.4:
Input I0+ Input U0+ Input I0– Input U0–
X3.1: X3.2: X3.3: X3.4:
Input I2+ Input U2+ Input I2– Input U2–
X2.1: X2.2: X2.3: X2.4:
Input I1+ Input U1+ Input I1– Input U1–
X4.1: X4.2: X4.3: X4.4:
Input I3+ Input U3+ Input I3– Input U3–
CPX-AB-8-KL-4POL
CPX-AB-4-HAR-4POL
1) 2)
Speedcon quick lock, screening additionally on metal thread FE/screening additionally on metal thread
2018/04 – Subject to change
è Internet: www.festo.com/catalogue/...
199
Page 200
Terminal CPX Accessories – Analogue module for temperature inputs Ordering data Designation
Part No.
Type
Input module, analogue 2 or 4 analogue temperature inputs
541486
CPX-4AE-T
195704 541254 195708 525636 549367
CPX-AB-4-M12X2-5POL CPX-AB-4-M12X2-5POL-R CPX-AB-8-KL-4POL CPX-AB-4-HAR-4POL CPX-M-AB-4-M12X2-5POL
M12 plug, 5-pin
175487
SEA-M12-5GS-PG7
HARAX plug, 4-pin
525928
SEA-GS-HAR-4POL
Cover for CPX-AB-8-KL-4POL (IP65, IP67) – 8 cable through-feeds M9 – 1 cable through-feed for multi-pin plug
538219
AK-8KL
Fittings kit
538220
VG-K-M9
Screening plate for M12 connections
526184
CPX-AB-S-4-M12
User manual
526415 526416 526417 526418 526419
P.BE-CPX-AX-DE P.BE-CPX-AX-EN P.BE-CPX-AX-ES P.BE-CPX-AX-FR P.BE-CPX-AX-IT
Connection block Plastic
4x socket, M12, 5-pin 4x socket, M12 with quick-lock technology, 5-pin Spring clip terminal, 32-pin 4x socket, quick connection, 4-pin 4x socket, M12, 5-pin
Metal Plug
Cover
Screening plate
User manual
200
German English Spanish French Italian
è Internet: www.festo.com/catalogue/...
Subject to change – 2018/04