Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact

The text of a spec sheet · part 10 of 25

Modular electrical terminal CPX, pages 91 to 100

Pages 91 to 100 of 246

The original document is the PDF (8.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

Filed in the catalog under the Festo CPX-EPL-EV

Page 91

Terminal CPX Accessories – Bus node CPX-FB23-24 Ordering data Description

Part No.

Type

CC-Link bus node

526176

CPX-FB23-24

Sub-D plug

532220

FBS-SUB-9-GS-2x4POL-B

Screw terminal bus connection

197962

FBA-1-KL-5POL

Inspection cover, transparent

533334

AK-SUB-9/15-B

Inscription label holder for connection block

536593

CPX-ST-1

Adapter from 5-pin M12 to mini USB socket and controller software

547432

NEFC-M12G5-0.3-U1G5

User documentation for bus node CPX-FB23-24

German

526403

P.BE-CPX-FB23-24-DE

English

526404

P.BE-CPX-FB23-24-EN

Chinese

8026069

P.BE-CPX-FB23-24-ZH

Bus node

Bus connection

User documentation

2018/04 – Subject to change

è Internet: www.festo.com/catalogue/...

91

Page 92

Terminal CPX Technical data – Bus node CPX-FB33 Bus node for operating the CPX valve terminal on PROFINET. The bus node is provided with system supply via the interlinking block and processes communication with the I/O modules. The status of the CPX terminal is displayed as a common message via four CPX-specific LEDs. The fieldbus communication status is displayed via three bus-specific LEDs.

Application Bus connection The bus connection is established via two M12 sockets, D-coded to IEC61076-2-101 with IP65, IP67 protection.

Both connections are equivalent 100BaseTX Ethernet ports with integrated auto MDI functionality

(cross-over and patch cables can be used) that are brought together via an internal switch.

Maximum segment length 100 m Transmission rate 100 Mbit/s or process equipment. In addition, non-real-time critical information such as diagnostic information, configura­ tion information, etc. can be trans­ ferred. The Ethernet bandwidth is sufficient to transfer both data types (real-time and non-real-time) in parallel.

The bus node features LEDs for bus status and CPX peripheral information as well as switch elements, memory stick and a diagnostic interface. The purpose of the memory stick is to guarantee fast replacement of the bus node in the event of an error. PROFINET provides the user with access to all peripherals, diagnostic data and parameter data of the CPX valve terminal. The bus node can be used as a remote I/O or remote con­ troller. All information relevant to the CPX can be read out and, depending on the function, changed via an MMI.

via the interlinking of the CPX modules and occupies an address capacity of the CPX system of: 8 byte outputs 8 byte inputs

The remaining address capacity of the control block or CPX system for actuating the peripherals is: 56 byte inputs 56 byte outputs

PROFINET implementation The CPX-FB33 supports the PROFINET protocol on the basis of the Ethernet standard and TCP/IP technology to IEEE802.3. This guarantees a data exchange with a high data transmission rate, for example I/O data from sensors, actuators or robot controllers, PLCs

Special points in combination with CPX-CEC When a bus node is combined with a control block (CPX-CEC, in the fieldbus remote controller operating mode), the connected I/Os and/or valves, sensors and actuators are controlled via the CPX control block.

In this case, the bus node only provides the communication interface to the PLC. Communication between the control block and CPX bus node is established

92

è Internet: www.festo.com/catalogue/...

Subject to change – 2018/04

Page 93

Terminal CPX Technical data – Bus node CPX-FB33 General technical data Type

CPX-FB33

Fieldbus interface Baud rate Protocol Max. address capacity LED displays

[Mbit/s]

Inputs Outputs (bus-specific)

[byte] [byte]

(product-specific)

Device-specific diagnostics

Configuration support Parameterisation

Additional functions

Control elements Operating voltage Current consumption Protection class to EN 60529 Temperature range

Nominal value Permissible range

[V DC] [V DC] [mA]

Operation Storage/transport Housing

[°C] [°C]

Materials Grid dimension Dimensions (incl. interlinking block) W x L x H Weight

-H- Note

-H- Note

Please observe the general limits and guidelines for the system when configuring the electrical modules.

Always use screws appropriate to the interlinking block (metal or plastic):

2018/04 – Subject to change

[mm] [mm] [g]

2x socket M12, D-coded, 4-pin 100 PROFINET RT PROFINET IRT 64 64 M/P = Maintenance/PROFIenergy NF = Network fault TP1 = Network active port 1 TP2 = Network active port 2 M = Modify, parameterisation PL = Load supply PS = Electronic supply, sensor supply SF = System fault Channel and module-oriented diagnostics Undervoltage of modules Diagnostic memory GSDML file System parameters Diagnostic behaviour Signal setup Fail-safe response Forcing of channels Start-up parameterisation in plain text via fieldbus Fast startup (FSU) Channel-oriented diagnostics via fieldbus Asynchronous data access via fieldbus System status can be represented using process data Additional diagnostic interface for operator units Asynchronous data access via Ethernet DIL switch Optional memory card 24 18 … 30 Typically 120 IP65, IP67 – 5… +50 –20 … +70 Die-cast aluminium 50 50 x 107 x 50 280

Self-tapping screws for plastic interlinking blocks

è Internet: www.festo.com/catalogue/...

Screws with metric thread for metal interlinking blocks

93

Page 94

Terminal CPX Technical data – Bus node CPX-FB33 Connection and display components

2

1 4

3

3

Pin allocation for the fieldbus interface Pin allocation

1 Bus-specific status LEDs 2 CPX-specific status LEDs 3 Fieldbus connection (4-pin socket M12, D-coded) 4 Transparent cover for DIL switch and memory card

Pin

Signal

Designation

1

TD+

Transmitted data+

2

RD+

Received data+

3

TD-

Transmitted data-

4

RD-

Received data-

M12 socket, D-coded

Housing

94

Screened

è Internet: www.festo.com/catalogue/...

Subject to change – 2018/04

Page 95

Terminal CPX Accessories – Bus node CPX-FB33 Ordering data Designation

Part No.

Type

PROFINET bus node

548755

CPX-FB33

Plug M12x1, 4-pin, D-coded

543109

NECU-M-S-D12G4-C2-ET

8040446 8040447 8040448 8040449 8040450 8040451 8040452 8040453 8040454 8040456 548757

NEBC-D12G4-ES-0.5-S-D12G4-ET NEBC-D12G4-ES-1-S-D12G4-ET NEBC-D12G4-ES-3-S-D12G4-ET NEBC-D12G4-ES-5-S-D12G4-ET NEBC-D12G4-ES-10-S-D12G4-ET NEBC-D12G4-ES-1-S-R3G4-ET NEBC-D12G4-ES-3-S-R3G4-ET NEBC-D12G4-ES-5-S-R3G4-ET NEBC-D12G4-ES-10-S-R3G4-ET NEBC-LE4-ES-5-D12G4-ET CPX-AK-P

Memory card for PROFINET bus node, 2 MB

568647

CPX-SK-2

Cover cap for sealing unused bus connections (10 pieces)

165592

ISK-M12

Screws for attaching an inscription label holder to the bus node (12 pieces)

550222

CPX-M-M2,5X8-12X

Adapter from 5-pin M12 to mini USB socket and controller software

547432

NEFC-M12G5-0.3-U1G5

548759 548760 548761 548762 548763

P.BE-CPX-PNIO-DE P.BE-CPX-PNIO-EN P.BE-CPX-PNIO-ES P.BE-CPX-PNIO-FR P.BE-CPX-PNIO-IT

Bus node

Bus connection

Connecting cable, straight plug, M12x1, 4-pin, D-coded

Straight plug, M12x1, 4-pin, D-coded

Straight plug, RJ45, 8-pin

Open end, 4-wire Transparent cover for DIL switch and memory card

0.5 m 1m 3m 5m 10 m 1m 3m 5m 10 m 5m

User manual Electronics manual, CPX bus node, type CPX-FB33

2018/04 – Subject to change

German English Spanish French Italian

è Internet: www.festo.com/catalogue/...

95

Page 96

Terminal CPX Technical data – Bus node CPX-M-FB34 Bus node for operating the CPX valve terminal on PROFINET. The bus node is provided with system supply via the interlinking block and processes communication with the I/O modules. The status of the CPX terminal is displayed as a common message via four CPX-specific LEDs. The fieldbus communication status is displayed via three bus-specific LEDs.

Application Bus connection The bus connection is established via two RJ45 push-pull sockets to IEC61076-3-106 and IEC60603 with IP65, IP67 protection.

Both connections are equivalent 100BaseTX Ethernet ports with integrated auto MDI functionality

(cross-over and patch cables can be used) that are brought together via an internal switch.

Maximum segment length 100 m Transmission rate 100 Mbit/s or process equipment. In addition, non-real-time critical information such as diagnostic information, configur­ ation information, etc. can be transferred. The Ethernet bandwidth is sufficient to transmit both data types (real-time and non-real-time) in parallel.

The bus node features LEDs for bus status and CPX peripheral information as well as switch elements, memory stick and a diagnostic interface. The purpose of the memory stick is to guarantee fast replacement of the bus node in the event of an error. PROFINET provides the user with access to all peripherals, diagnostic data and parameter data of the CPX valve terminal. The bus node can be used as a remote I/O or remote con­ troller. All information relevant to the CPX can be read out and, depending on the function, changed via an MMI.

via the interlinking of the CPX modules and occupies an address capacity of the CPX system of: 8/16 byte outputs 8/16 byte inputs

The remaining address capacity of the control block or CPX system for actuating the peripherals is: 56/48 byte inputs 56/48 byte outputs

PROFINET implementation The CPX-M-FB34 supports the PROFINET protocol based on the Ethernet standard and the TCP/IP technology to IEEE802.3. This guarantees a data exchange with a high data transmission rate, for example I/O data from sensors, actuators or robot controllers, PLCs

Special points in combination with CPX-CEC When a bus node is combined with a control block (CPX-CEC, in the fieldbus remote controller operating mode), the connected I/Os and/or valves, sensors and actuators are controlled via the CPX control block.

In this case, the bus node only provides the communication interface to the PLC. Communication between the control block and CPX bus node is established

96

è Internet: www.festo.com/catalogue/...

Subject to change – 2018/04

Page 97

Terminal CPX Technical data – Bus node CPX-M-FB34 General technical data Type

CPX-M-FB34

Fieldbus interface Baud rate Protocol Max. address capacity LED displays

[Mbit/s]

Inputs Outputs (bus-specific)

[byte] [byte]

(product-specific)

Device-specific diagnostics

Configuration support Parameterisation

Additional functions

Control elements Operating voltage

Nominal value Permissible range Intrinsic current consumption at nominal operating voltage Protection class to EN 60529 Temperature range Operation Storage/transport Material of housing Grid dimension Dimensions (incl. interlinking block) W x L x H Weight

-H- Note

-H- Note

Please observe the general limits and guidelines for the system when configuring the electrical modules.

Always use screws appropriate to the interlinking block (metal or plastic):

2018/04 – Subject to change

[V DC] [V DC] [mA] [°C] [°C] [mm] [mm] [g]

2x RJ45 push-pull socket, AIDA 100 PROFINET RT PROFINET IRT 64 64 M/P = Maintenance/PROFIenergy NF = Network fault TP1 = Network active port 1 TP2 = Network active port 2 M = Modify, parameterisation PL = Load supply PS = Electronic supply, sensor supply SF = System fault Channel and module-oriented diagnostics Undervoltage of modules Diagnostic memory GSDML file System parameters Diagnostic behaviour Signal setup Fail-safe response Forcing of channels Start-up parameterisation in plain text via fieldbus Fast startup (FSU) Channel-oriented diagnostics via fieldbus Asynchronous data access via fieldbus and via Ethernet System status can be represented using process data Additional diagnostic interface for operator units DIL switch, optional memory card 24 18 … 30 Typically 120 IP65, IP67 – 5… +50 –20 … +70 Die-cast aluminium 50 50 x 107 x 80 280

Self-tapping screws for plastic interlinking blocks

è Internet: www.festo.com/catalogue/...

Screws with metric thread for metal interlinking blocks

97

Page 98

Terminal CPX Technical data – Bus node CPX-M-FB34 Connection and display components

2

1 4

3

3

Pin allocation for the fieldbus interface Pin allocation

1 Bus-specific status LEDs 2 CPX-specific status LEDs 3 Fieldbus connection (8-pin RJ45 socket) 4 DIL switch and memory card

Pin

Signal

Designation

1 2 3 4 5 6 7 8 Housing

TD+ TDRD+ n.c. n.c. RDn.c. n.c. Screened

Transmitted data+ Transmitted dataReceived data+ Not connected Not connected Received dataNot connected Not connected Screened

RJ45 socket

98

è Internet: www.festo.com/catalogue/...

Subject to change – 2018/04

Page 99

Terminal CPX Accessories – Bus node CPX-M-FB34 Ordering data Designation

Part No.

Type

PROFINET bus node

548751

CPX-M-FB34

RJ45 plug, 8-pin, push-pull

552000

FBS-RJ45-PP-GS

Cover cap for bus connection

548753

CPX-M-AK-C

Cover cap for bus connection

2873540

CPX-M-AK-D

Cover for DIL switch and memory card

548754

CPX-M-AK-M

Memory card for PROFINET bus node, 2 MB

568647

CPX-SK-2

Screws for attaching an inscription label holder to the bus node (12 pieces)

550222

CPX-M-M2,5X8-12X

Adapter from 5-pin M12 to mini USB socket and controller software

547432

NEFC-M12G5-0.3-U1G5

Electronics manual, CPX bus node, type CPX-M-FB34

548759 548760 548761 548762 548763

P.BE-CPX-PNIO-DE P.BE-CPX-PNIO-EN P.BE-CPX-PNIO-ES P.BE-CPX-PNIO-FR P.BE-CPX-PNIO-IT

Bus node

Bus connection

User manual

2018/04 – Subject to change

German English Spanish French Italian

è Internet: www.festo.com/catalogue/...

99

Page 100

Terminal CPX Technical data – Bus node CPX-M-FB35/CPX-M-FB41 Bus node for operating the CPX valve terminal on PROFINET. The bus node is provided with system supply via the interlinking block and processes communication with the I/O modules. The status of the CPX terminal is displayed as a common message via 4 CPX-specific LEDs. The fieldbus communication status is displayed via three bus-specific LEDs.

Application Bus connection The connections on the CPX-M-FB35 are equivalent 100BaseFX Ethernet ports that are brought together via an internal switch.

Fibre-optic cables made from plastic (POF, 980/1000 μm) are also suitable for transmission.

Maximum segment length 50 m Transmission rate 100 Mbps Supports LLDP and SNMP process equipment. Furthermore, non real-time critical information such as diagnostic information, configuration information, etc. can be transferred. The Ethernet bandwidth is sufficient to transmit both data types (real-time and non real-time) in parallel.

The bus node features LEDs for bus status and CPX peripheral information as well as switch elements, memory stick and a diagnostic interface. The purpose of the memory stick is to guarantee fast replacement of the bus node in the event of an error. PROFINET provides the user with access to all peripheral, diagnostic and parameter data for the CPX valve terminal. The bus node can be used as a remote I/O or remote controller. All information relevant to the CPX can be read out and, depending on the function, changed via an MMI.

When a bus node is combined with a control block (CPX-CEC, in the fieldbus remote controller operating mode), the connected I/Os and/or valves, sensors and actuators are controlled via the CPX control block.

In this case, the bus node only provides the communication interface to the PLC. Communication between the control block and CPX bus node takes place by interlinking the CPX modules and takes up the following address capacity in the CPX system: 8/16 byte outputs 8/16 byte inputs

The following address capacity remains in the control block or CPX system for activating the peripherals: 56/48 byte inputs 56/48 byte outputs

100

è Internet: www.festo.com/catalogue/...

The bus connection is established via SCRJ push-pull sockets to IEC61754-24 (fibre-optic cable, AIDA standard) with degree of protection to IP65, IP67. PROFINET implementation The CPX-M-FB35/CPX-M-FB41 supports the PROFINET protocol based on the Ethernet standard and TCP/IP technology to IEEE802.3. This guarantees a data exchange with a high data transmission rate, for example I/O data from sensors, actuators or robot controllers, PLCs or Points to note in connection with CPX-CEC

Subject to change – 2018/04