Page 1 of AF-300 G11 Specifications

Spec sheet · GE

AF-300 G11 Specifications

Spec sheet14 pagesPDF 278 KB

Product specifications for the GE AF-300 G11 AC drive: ratings, control features, terminals, protection and dimensions.

Download the PDF278 KB

Covers · 3 models

The models it covers

Summary

What is in it

GE Industrial Systems' product specifications for the AF-300 G11 adjustable frequency AC drive in 230 VAC and 460 VAC three-phase series. It lists motor ratings, braking torque, enclosures and standards, input and environmental conditions, output and control specifications (V/Hz, sensorless dynamic torque vector and flux-vector control), operating features, keypad indication and trip codes, protection functions, every terminal function, input and output ratings by model, dimensions for each size and the plug-in terminal strip assignments.

From the sheet · read page by page

Key facts from this sheet

Each line names its page in the PDF.

GE Industrial Systems product specifications for the AF-300 G11 AC drive in its three-phase 230 VAC and 460 VAC series. It lists ratings, input and output data, control and protective functions, control terminal assignments, options and dimensions, so a reader can choose, size and wire a drive.

Ratings
230 VAC, 3 phase: 1/4 Hp to 125 Hp; 460 VAC, 3 phase: 1/2 Hp to 450 Hp p. 2
Input voltage
Up to 30 Hp: 200V - 230V (230 VAC) or 380V - 480V (460 VAC), +10%/-15%, 50 or 60 Hz p. 2
Control method
Sinusoidal PWM; V/Hz, Dynamic Torque Vector Control (sensorless) or flux-vector control with pulse tachometer p. 3
Overload
150% of rated current for 1 min p. 2
Frequency
Max. frequency 50 - 400 Hz; carrier 0.75 - 15 kHz up to 100 Hp, 0.75 - 10 kHz 125 Hp and above p. 2
Serial link
RS485 with Modbus RTU standard (terminals DX+, DX-, SD); up to 31 drives in a daisy chain p. 3, 14
Network options
GENIUS, Profibus DP, N2 - Metasys, Interbus-S, Modbus Plus, DeviceNet p. 8
Analog inputs
Terminal 12: 0 to +10V DC, 22 k Ohm; C1: 4 to 20mA DC, 250 Ohm; 13: +10V DC for a 1 to 5k Ohm pot p. 12
Digital inputs
FWD, REV and X1 to X9, functions set by function codes; sink type by default, source type selectable p. 6, 13
Relay outputs
Alarm relay 30A, 30B, 30C (1SPDT) and programmable Y5A, Y5C; 250 VAC, 0.3A or 48 VDC, 0.5A for CE Marking p. 14
Keypad
Backlit LCD; Smart Keypad copies parameters between drives; RJ45 extension cable up to 100' p. 3, 8
Enclosure
1/4 Hp to 30 Hp: NEMA 1 standard, NEMA 4 optional to 10 Hp, NEMA 12 optional; 40 Hp and up: NEMA 1, IP00 optional p. 2
Temperature
Ambient -10 to 50°C; storage -20 to 65°C p. 2
Type designation
230V series 6KG1123..., 460V series 6KG1143...; suffix X1A1 NEMA Type1, X2A1 Type12, X4A1 Type4, X9A1 open p. 8

What this sheet walks you through

  • Input and output ratings of the 230V and 460V series p. 8
  • Control terminal strip assignments and functions p. 12, 13, 14
  • Main circuit terminals for power, motor, DC reactor and braking p. 5
  • Choosing functions for the digital inputs p. 6
  • Signals available on the transistor outputs p. 7
  • Built-in protective functions p. 5
  • Keypad displays and trip diagnostics p. 4
  • Dimensions of 1/4 to 30 Hp drives p. 9
  • Dimensions and weights of NEMA 1 drives p. 10
  • Dimensions of open type drives for surface or through-panel mounting p. 11

Good to know

  • Above 1000 meters the drive is derated 1% for each 100 meters up to 3000 meters. p. 2
  • Drives of 30 Hp and below must have their ventilation covers removed at 40°C and above. p. 2
  • Below Vmin (165V for the 230V series, 310V for the 460V series) the drive runs at 85% of rated output for 15 ms. p. 2
  • Only one of the analog inputs V2 or C1 may be used. p. 12
  • Current derating may be needed with a low impedance load such as a high frequency motor. p. 8

Questions this sheet answers

What horsepower range does the AF-300 G11 cover?

The 230 VAC three-phase series runs from 1/4 Hp to 125 Hp and the 460 VAC series from 1/2 Hp to 450 Hp. p. 2

Which networks can the AF-300 G11 connect to?

RS485 with Modbus RTU is standard; option cards are listed for GENIUS, Profibus DP, N2 - Metasys, Interbus-S, Modbus Plus and DeviceNet. p. 3, 8

What is the AF-300 G11 alarm relay contact rating?

The 30A, 30B, 30C alarm relay (1SPDT) is rated 250 VAC, 0.3A or 48 VDC, 0.5A for CE Marking. p. 14

Can the AF-300 G11 keypad copy parameters to another drive?

Yes. The Smart Keypad copies parameters from one drive to another, and an RJ45 cable adaptor allows keypad extension up to 100'. p. 3, 8

What is the AF-300 G11 operating temperature?

Ambient -10 to 50°C, with drives of 30Hp and below needing ventilation covers removed at 40°C and above; storage -20 to 65°C. p. 2

The whole text · 2 parts

Read the sheet here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 71-7
  2. Pages 8 to 148-14

The file

Size and text

PublisherGE Industrial Systems
Pages14
PDF278 KB
TextText from the PDF itself.

The first pages · 4 of 14

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 14
Page 2
Page 2of 14
Page 3
Page 3of 14
Page 4
Page 4of 14

More documents · 1

For the same models