Page 121
Catalog No.
Rating
Drive HP & Quantity per drive 1/2 1 2 3 5
7.5
10
15
20
25
30
1
1
1
1
1
1
AF-300 G11 460 VAC, 30 Hp and Below Main Control Card G11CPCBB1 1 1 1 1 Gate Driver & Power Supply Card G11PPCBG4004 1 G11PPCBG4008 1 G11PPCBG4015 1 G11PPCBG4022 1 G11PPCBG4037 G11PPCBG4055 G11PPCBG4075 G11PPCBG4110 G11PPCBG4150 G11PPCBG4185 G11PPCBG4220 KEYPAD PANEL (Only one type per drive) TPAG11S NEMA1 1 1 1 1 TPAG11S4 NEMA Type4 1 1 1 1 DC CAPACITOR * * G11CAP04 PCB 1 G11CAP05 PCB 1 G11CAP06 PCB G11CAP07 1500µF G11CAP08 2000µF G11CAP09 2700µF G11CAP10 3900µF G11CAP11 4700µF G11CAP12 5400µF * Located on Gate drive & Power supply Card FAN G11FAN01 1 1 G11FAN02 POWER MODULE * * PS12046 15A 1200V 1 1 PS12047 25A 1200V 6MBP50RS120 50A 1200V 6MBP75RS120 75A 1200V 6MBP100RS120 100A 1200V * Located on Gate drive & Power supply Card RECTIFIER MODULE * * * * PVC75-16 75A 1600V CLK70AA160 70A 1600V CLK100AA160 100A 1600V * Located on Gate drive & Power supply Card CHARGE RESISTOR * * * * 30W200 30W 20WJ 80W100 80W 10WJ * Located on Gate drive & Power supply Card FRONT COVER G11UPCG008 1 1 G11UPCG040 1 1 G11UPCG075 G11UPCG220 INTERNAL DB RESISTOR G11DBR0044 720W 30W 1 G11DBR0084 470W 40W 1 G11DBR0374 200W 80W 1 1 G11DBR0754 100W 90W 10-3 Data subject to change without notice 9/00. © 2000 GE Fuji Drives USA
1
1 1 1 1 1 1 1 1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 2 2 2 2 2 2
1 1
1
1
1
2
2
1
1
2
2
1
1
1
1
1
* 1
1 1
1
* 1
1 1
1
1
1
1
1
1
1
1 1
1
1 1
1
Page 122
Catalog No.
Rating
Drive HP & Quantity per drive 40 50 60 75 100 125 150 200 250 300 350 400 450 500 600
AF-300 G11 460 VAC, 40 Hp and Above Main Control Card EP4113B1
1
Gate Driver & Power Supply Card EP3959C1 EP3959C2 EP3959C3 EP3959C4 EP3959C5 EP3957C3 EP3957C4 EP3957C5
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
DC CAPACITOR LNT2G302MSMAFF HCGHA2G362N3K HCGHA2G452NE3K HCGHA2G592N3K HCGHA2G742N3K HCGHA2G932N3K FAN FBA09A24H1B0 MRS18-DUL THB1-UHS4556M (Standard) 4715PS22TB30 2750MTP15 6250MG1 (For NEMA12 Heatsink) UHS4556MLOT1 2750MTP15OT1 U6250MKG1LTPOT1 IGBT MODULE 2MBi150PC14002 CM200DU24H203 2MBi300P14002 CM200DU24H202 2MBi300P14003
1
1
1
1
1
1
3
3
3
3
1
1
1
1
20
20
26
26
4 3
4 3
4 4
4 4
18
18
24
24
1 1
1 400V 3000µF 400V 3600µF 400V 4500µF 400V 5900µF 400V 7400µF 400V 9300µF
1
1
Gate Drive Amplifier Card EP4142 KEYPAD PANEL TPAG11S4
1
1
1
1
1
4
4
1
1
1
6
8
1
1
1
4 4 4
6 12 8
1
1
1
1
2
2
2
3
3
12
4
4
2 2
2
3 2
2
2
2
3 3
3
4
4
3
3
4
4
9
9
12
12
2 2
2
3
3
3 3 3
3 6 6
10-4
6
Data subject to change without notice 9/00. © 2000 GE Fuji Drives USA
Page 123
Catalog No.
Rating
Drive HP & Quantity per drive 40 50 60 75 100 125 150 200 250 300 350 400 450 500 600
AF-300 G11 460 VAC, 40 Hp and Above RECTIFIER MODULE PD6016A PD10016A
3
CHARGE RESISTOR HF5C5504 GRZG400
80W 7.5ohm 600W 5ohm
1
DC CONTACTOR FC1UL FC4UL SC7NUL SC8NUL SCN8
AC220VAUX2B AC220VAUX2B AC200-240V AC200-240V AC200-240V
1
600V 150A 600V 200A 600V 300A
1
DC FUSE CR6L150UL CR6L200UL CR6L300UL A70Q4004 A70Q5004 A70Q6004 A70QS8004 A70P16004TA A70P20004 TRANSFORMER HF5C55025512VA HF5C550312524VA HF5B661330016VA HF5B395170020VA INPUT MODULE CARD EP3985C2 EP3985C4
3
1
1
12 3
3
6
6
6
1
1
1
2
2
1
1
2
2
2
12
3
12
12
3
4
24
24
30
30
2
2
2
2
2
2
2
2
1
1 1
1
2 2
2 1 1
1 1 1
1 1
1 1 1
1 1
1 1
1
1
1 1
1
Data subject to change without notice 9/00. © 2000 GE Fuji Drives USA
1
1
1
1
1
1
1
1
1 1
1
1
1
1
1
1
1
1 1
10-5
1
1
1
1
Page 124
Notes:
10-6
Data subject to change without notice 9/00. © 2000 GE Fuji Drives USA
Page 125
Three-phase 230V series
Data subject to change without notice 9/00. © 2000 GE Fuji Drives USA
11-1
Maximum Freq. Base Freq. Starting Freq. Carrier Freq. *8)
Starting torque Braking torque Standard Time Duty cycle Braking torque Options Time Duty cycle DC injection braking
Volt/Freq Characteristic Torque boost
Setting resolution
Accuracy (Stability)
Setting
Voltage / frequency variations Momentary voltage dip capability *6)
Rated Frequency Phases, Voltage, Frequency
F50
001
002
003
005 s % s %
33
25
46
15 18
015
59
20 23
020
74
25 29
025
87
30 34
030
(Maximum voltage[V] - Minimum voltage[V] ) 3-phase averaging voltage[V]
X 100 [%]
80 to 240V (with AVR control) at base and maximum frequency, adjustable Constant toruque load Variable torque load Automatic (setting code) : 0.0 Manual (setting code) : 2.0 to 20.0 0.1 to 1.9 *9) 200% (with Dynamic torque vector control selected) 150% 100% 20% *10) 10 5 5 10 5 3 5 3 2 3 2 150% 90 45 45 45 30 20 10 8 37 22 18 10 7 5 5 5 Starting frequency : 0.1 to 60.0Hz , Braking time : 0.0 to 30.0s , Braking level : 0 to 100% of rated current NEMA Type1, Type4 NEMA Type1, Type12 Natural Fan cooling -UL/cUL -LOW VOLTAGE directive -IEC 61800-2 (Rating, -EMC directive -IEC 61800-3 (EMC product specifications for low voltage adjustable frequency standard including specific test methods) a.c. power drive systems)
1/20000 of Maximum frequency ex.) 0.003Hz at 60Hz , 0.01Hz at 400Hz 0.01Hz (Fixed)
*6) Input power : 85% *8) If carrier frequency is set at more than 10kHz and an overheat condition (detected by internal thermal sensor ) occurs,inverter will automatically reduce carrier frequency to 8kHz , in order to avoid trip.(Available up to 30HP unit) *9) When setting into 0.1,the starting torque gets 50% *10) With a nominal applied motor.(Average torque when the motor decelerates and stops from 60Hz. It may change according to the motor loss.) *11) Above 120Hz application, please contact the factory.
Unbalance in power supply voltage [%] =
10 13
010
7.5 9.9
007
50 57
050
60 71
060
215
75 85
075
283
100 112
100
346
125 137
125
Open, Open with NEMA Type 12 Heatsink, NEMA 1
180% (with Dynamic torque vector control selected) 15 to 10% *10) No limit No limit 100% 10 10
0.75 to 10kHz
3-phase, 200 to 220V /50Hz , 200 to 230V /60Hz * 220 to 230V /50Hz *4), -Frequency :+5 to -5%
115 145 180 150% of rated current for 1min , 180% of rated current for 0.5s
40 45
040
-Voltage : +10 to -15% ( Voltage unbalance *5) : 2% or less ) When the input voltage is 165V or more, the inverter can be operated continuously. When the input voltage drops below 165V from rated voltage, the inverter can be operated for 15ms . (within 85% load of nominal applied motors) The smooth recovery method is selectable. 50 to 400Hz *11) 25 to 400Hz *11) 0.1 to 60Hz, Continuous time : 0.0 to 10.0s 0.75 to 15kHz The minimum carrier frequency changes depend on maximum output frequency. -Analog setting : ±0.2% of Maximum frequency (at 25 ±10 degrees C) -Digital setting : ±0.01% of Maximum frequency (at -10 to +50 degrees C) -Analog setting : 1/3000 of Maximum frequency ex.) 0.02Hz at 60Hz ,0.15Hz at 400Hz -Digital setting : 0.01Hz at Maximum frequency of up to 99.99Hz (0.1Hz at Maximum frequency of 100Hz and above) -Link setting : Two methods are selectable.
Hz 50, 60Hz 3-phase, 200 to 230V , 50/60Hz
HP 1/4 1/2 1 2 3 5 kVA 0.59 1.1 1.9 3.1 4.3 6.7 V 3-phase, 200V /50Hz , 200V ,220V ,230V /60Hz A 1.5 3.0 5.0 8.0 11 17 150% of rated current for 1min , 200% of rated current for 0.5s
F25
NOTES *1) Inverter output capacity [kVA] at 230V. *2) Output voltage is proportional to the power supply voltage and can't exceed the power supply voltage. *3) Current derating may be required in case of low impedance load such as high frequency motor. *4) 220 to 230V/50Hz : Order individually *5) Reference to the IEC 61800-3( 5.2.3 )
Enclosure Cooling method Standards
Braking
Control
Output frequency
Input ratings
Nominal 230V system pplied motor Output Rated Capacity *1) ratings Rated Voltage *2) Rated Current *3) Overload Capability
6KG1123_ _ _X1 * * (NEMA Type1) 6KG1123_ _ _ X2 * * (NEMA Type12) 6KG1123_ _ _ X4 * * (NEMA Type4) 6KG1123_ _ _ X8 * * (Open, Type 12 Heatsink) 6KG1123_ _ _ X9 * * (Open)
Type designation ( * * indicate product revision)
11. Specifications
11.1 Standard Specifications
Page 126
11-2
Data subject to change without notice 9/00. © 2000 GE Fuji Drives USA
Standards
Starting torque Braking torque Time Duty cycle Braking torque Options Time Duty cycle DC injection braking
Volt/Freq Characteristic Torque boost
Setting resolution
001
002
003 s % s %
007
010
5 7.5 10 7.1 10 14 380V , 400V , 440V , 460V /60Hz 9.0 13 18
005
39
45
30 35
030
50 59
050
60 72
060
75 89
075
-UL/cUL
(Maximum voltage[V] - Minimum voltage[V] ) 3-phase averaging voltageV
U2
CN UX connector U1 (Factory setting)
X 100 [%]
210
150 167
150
253
200 201
200
15 to 10% *11)
-Frequency :+5 to -5%
Open, Open with NEMA Type 12 Heatsink, NEMA Type 1 Fan cooling
100% 10 10
176
125 140
125
0.75 to 10kHz
Variable torque load 0.1 to 1.9 *9) 180% (with Dynamic torque vector control selected)
1/20000 of Maximum frequency ex.) 0.003Hz at 60Hz , 0.01Hz at 400Hz 0.01Hz (Fixed)
-LOW VOLTAGE directive -IEC 61800-2 Rating, -EMC directive -IEC 61800-3 (EMC product specifications for low voltage adjustable frequency a.c. standard including specific test methods) power drive systems)
150
100 119
100
3-phase, 380 to 440V /50Hz , 380 to 480V /60Hz * 380V/50Hz and 380 to 415V/60Hz *4)
60 75 91 112 150% of rated current for 1min , 180% of rated current for 0.5s
40 47
040
*6) Input power : 85% *8) If carrier frequency is set at more than 10kHz and an overheat condition (detected by internal thermal sensor ) occurs, inverter will automatically reduce carrier frequency to 8kHz , in order to avoid trip.(Available up to 30HP unit) *9) When setting into 0.1, the starting torque gets 50% *10) Above 120Hz application, please contact the factory *11) With a nominal applied motor.(Average torque when the motor decelerates and stops from 60Hz. It may change according to the motor loss.)
Unbalance in power supply voltage [%] =
30
24
25 31
025
320 to 480V (with AVR control) at base and maximum frequency, adjustable Constant toruque load Automatic (setting code) 0.0 Manual (setting code) 2.0 to 20.0 200% (with Dynamic torque vector control selected) 150% 100% 20% *11) 5 5 No limit 5 3 5 3 2 3 2 No limit 150% 45 45 30 20 10 8 22 10 7 5 5 5 Starting frequency : 0.1 to 60.0Hz , Braking time : 0.0 to 30.0s, Braking level : 0 to 100% of rated current NEMA Type1, Type 4 NEMA Type1, Type12 Natural
Input voltage 400 to 440V/50Hz, 440 to 480V/60Hz 380V/50Hz (398V or smaller), 380 to 415V/60Hz (430V or smaller)
*5) Reference to the IEC 61800-3( 5.2.3 )
20 23
020
15 19
015
-Voltage : +10 to -15% ( Voltage unbalance *5) : 2% or less ) When the input voltage is 310V or more, the inverter can be operated continuously. When the input voltage drops below 310V from rated voltage, the inverter can be operated for 15ms . (less than 85% load of nominal applied motors) The smooth recovery method is selectable. 50 to 400Hz *10) 25 to 400Hz *10) 0.1 to 60Hz , Continuous time : 0.0 to 10.0s 0.75 to 15kHz The minimum carrier frequency changes depend on maximum output frequency. -Analog setting : ±0.2% of Maximum frequency (at 25 ±10 degrees C) -Digital setting : ±0.01% of Maximum frequency (at -10 to +50 degrees C) -Analog setting : 1/3000 of Max. frequency ex.) 0.02Hz at 60Hz , 0.15Hz at 400Hz -Digital setting : 0.01Hz at Maximum frequency of up to 99.99Hz (0.1Hz at Maximum frequency of 100Hz and above) -Link setting : Two methods are selectable.
HP 1/2 1 2 3 kVA 1.1 1.9 2.9 4.3 V 3-phase, 380V , 400V , 415V /50Hz , A 1.5 2.5 3.7 5.5 150% of rated current for 1min , 200% of rated current for 0.5s Hz 50, 60Hz 3-phase, 380 to 480V , 50/60Hz
F50
NOTES *1) Inverter output capacity [kVA] at 460V. *2) Output voltage is proportional to the power supply voltage and can't exceed the power supply voltage. *3) Current derating may be required in case of low impedance load such as high frequency motor. *4) Change the tap of auxiliary transformer. 380V/50Hz and 380 to 415V/60Hz : Change over CN UX connector from U1 part to U2 part. (Reference to the Instruction manual)
Standards
Maximum Freq. Base Freq. Starting Freq. Carrier Freq. *8)
Accuracy (Stability)
Setting
Voltage / frequency variations Momentary voltage dip capability *6)
Rated Frequency Phases, Voltage, Frequency
Enclosure Cooling method
Braking
Control
Output frequency
Input ratings
Norminal 460V system applied motor Rated Capacity *1) Rated Voltage *2) Rated Current *3) Overload Capability
6KG1143_ _ _X1 * * (NEMA Type1) 6KG1143_ _ _ X2 * * (NEMA Type12) 6KG1143 X4 * * (NEMA Type 4)
Type designation ( * * indicate product revision)
Three-phase 460V series
304
250 242
250
377
300 300
300
415
350 330
350
520
400 414
400
585
650
500
518
450
500
466
450
740
590
600
600
Page 127
11.2 Common Specifications Item Control Method
Output frequency
Maximum frequency Base frequency Starting frequency Carrier frequency Accuracy (stability)
Control
Setting resolution Voltage/frequency Characteristics Torque Boost
Accelerating/decelerating time
DC injection braking
Operation
Function equipped
Explanation Sinusoidal wave PWM control (with V/F control, torque vector control, PG feedback vector control (option) 50 to 400 Hz variable setting 25 to 400 Hz variable setting 0.1 to 60 Hz variable setting Holding time: 0.0 to 10.0 s 0.75 to 15k Hz (75 HP or less) 0.75 to 10k Hz (100 HP or more) Analog setting: +/- 0.2% or less of the max. frequency (at 25 +/- 10°C) Digital Setting: +/- 0.01% or less of the max frequency (-10 to +50°C) Analog setting: 1/3000 of max. frequency (e.g. 0.02 Hz / 60 Hz, 0.05 Hz / 150 Hz) Digital setting: 0.01 Hz (99.99 Hz or less), 0.1 Hz (100.0 Hz or more) Output voltage at base frequency can be adjusted separately, such as 80 to 240V (200V series) or 320 to 480V (400V series) Auto: Optimum control corresponding to the load torque. Manual: 0.1 to 20.0 code setting (energy savings reduced torque, constant torque (strong) etc.) 0.01 to 3600s Four accelerating and decelerating time settings are possible independent of each other by selecting digital input signals. In addition to linear acceleration and deceleration, either S-shaped acceleration/deceleration (weal/strong) or curvilinear acceleration/deceleration can be selected. Starting frequency: 0.0 to 60 Hz, braking time: 0.0 to 30.0s Braking levels: 0 to 100% Frequency upper and lower limiter, bias frequency, frequency gain, jump frequency, pick-up operation, restart after momentary power failure, switching operation from line to drive, slip compensation control, automatic energy saving operation, regeneration avoiding control, droop control, torque limiting (2-strp), torque control, PID control, second motor switching, cooling fan ON/OFF control.
Operation method
Keypad panel: Run by FWD REV keys, stop by STOP key. Terminal input: Forward/Stop command, Reverse/Stop command, Coast-to-Stop command, Alarm reset, acceleration/deceleration selection, multistep frequency selection, etc.
Frequency setting
Keypad panel: setting by UP and DOWN keys External potentiometer: External freq. Setting POT (VR) (1 to 5k ohm) Analog input: 0 to +10V (0 to 5V), 4 to 20 mA, o to ± 10V (FWD/REV operation) +10 to 0 (reverse operation), 20 to 4 mA (reverse operation) UP/DOWN control: Frequency increases or decreases as long as the digital input signals are turned on Multistep frequency selection: Up to 15 steps are selectable by a combination of digital input signals (four kinds) Link operation: Operation by RS485 (standard) Program operation: Pattern operation by program Jogging operation: Jogging operation by FWD, REV key or digital input signals.
Operation status signal
Transistor output (4 signals): Running, frequency, arrival, frequency detection, overload early warning, etc. Relay output (2 signals): Alarm output (for any fault), multi-purpose output signals Analog output (1 signal): Output frequency, output current, output voltage, output torque, power consumption, etc. Pulse output (1 signal): Output frequency, output current, output power, output torque, power consumption, etc.
Data subject to change without notice 9/00. © 2000 GE Fuji Drives USA
11-3
Page 128
11.2 Common Specifications (continued) Item
Environment
Indication
Digital display LED
Liquid crystal display
Explanation Output frequency, setting frequency, output current, output voltage, motor synchronous speed, line speed, load rotation speed, calculated PID value, PID command value, PID feedback value, alarm code. Operation information, operational guide, functional code/name/setting data, alarm information, tester function, motor load rate measuring function (Maximum/average current (rms) during measuring period, maintenance information (integrated operation hours, capacitance measurement for main circuit capacitors, heatsink temperature, etc.
Language
Six languages (Japanese, English, German, French, Spanish, Italian)
Lamp display
Charging (voltage residual), operation indication
Protective function
Overcurrent, short-circuit, ground fault, overvoltage, undervoltage, overload, overheating, blown fuse, motor overload, external alarm, input open-phase, output open0phase (when tuning), braking resistor protection, CPU and memory error, keypad panel communications error, PTC thermistor protection, surge protection, stall prevention, etc.
Installation location
Indoor, altitude less than 3300 feet (1000m), free from corrosive gas, dust and direct sunlight.
Ambient temperature
-10 to +50°C (+14 to 122°F) (ventilating cover must be removed under conditions exceeding +40°C (+104°F) for models rated at 30 HP or less)
Vibration Storage
3mm peak from 2-9 Hz, 9.8 m/s2 from 9-20 Hz, 2m/s2 from 20-55 Hz, 1 m/s2 from 55-200 Hz,
Ambient temperature
-25 to 65°C (-13 to 149°F)
Ambient humidity
5 to 95% (no condensation)
11-4
Data subject to change without notice 9/00. © 2000 GE Fuji Drives USA
Page 129
11.3 Outline Dimensions 4.34(110)
0.28(7)
D
3.78(96)
D1 0.24(6)
0.28(7)
5.91(150) 0.28(7)
0.28(7)
D2
Main circuit terminals (M4)
D3
0.61(15.5)
9.69(246) 10.25(260)
Auxiliary control power supply terminals (M3, 5)
NP
0.61(15.5) 1.56(39.5)
3.43(87) 0.28(6)
0.31(8)
3-ø”0.87(ø”22) Wire inlet knock out hole
1.22(31) 1.73(44)
8.66(220) 0.47(12)
D2 3.15 (80) 3.74 (95)
D3 3.7 (94) 4.29 (109)
D4 2.81 (71.5) 3.41 (86.5)
2 to 5 Hp
0.47(12) 7.68(195) 4.09(104) 0.44(11)
7.72(196)
2-ø”0.39(ø”10)
0.31(8) 3-ø”0.87(ø”22) Wire inlet Knock out hole
3.92(99.5)
D1 1.44 (26.5) 2.03 (51.5)
3.74(95) 4.29(109)
1.22(31)
1.06(27) D4
D 5.12 (130) 5.71 (145)
0.24(6)
Control circuit terminals (M3) NP
0.24(6)
1 Hp
2.42 (61.5)
0.28(7)
9.69(246)
10.25(260)
Main circuit terminals (M3, 5)
5.71(145)
5.35(136)
2-ø”0.24(ø”6)
Control circuit terminals M3
Type 1/4, 1/2 Hp
0.28(7)
0.28(7)
2-ø”0.24(ø”6)
9.84(250) 8.90(226)
0.47(12)
2-ø”0.39(ø”10)
0.39(10)
0.47(12) 7.68(195) 4.17(106) 0.44(11)
0.28(7)
0.39(10)
Control circuit terminals
Main circuit terminals (M5) 0.44(11)
14.88(378) 15.76(400)
(M5)
6.26(159) 0.31(8)
5.06(128.5) 5.12(130)
0.39(10)
2.07(52.5) 2-ø”1.34(ø”34) Wire inlet knock out hole
ø”1.34(ø”34) Wire inlet knock out hole
7.5, 10 Hp
Data subject to change without notice 9/00. © 2000 GE Fuji Drives USA
2.42(61.5)
2.54(64.5)
11-5
0.44(11)
2.17(55)
5.75(146)
5.51(140)
5.67(144)
Main circuit terminals NP
1.81(46) ø”1.06(ø”27) Wire inlet knock out hole
Auxiliary control power supply terminals (M3, 5)
5.49(139.5) 0.39(10)
2.28(58)
Control circuit terminals (M3) NP
Auxiliary control power supply terminals (M3, 5)
10.25(260)
9.37(238)
(M3)
6.26(159) 0.31(8)
2-ø”1.65(ø”42) Wire inlet knock out hole
15 to 30 Hp
Page 130
11.3.1 Outline Dimensions NEMA 1
230V Series NEMA 1 Hp 40 50
W1 9.4 (240) 10.8 (275)
W3 –
W4 13.5 (342) 14.9 (377)
60
H1 20.9 (530) 23.4 (595) 28.3 (720)
H2 19.7 (500) 22.2 (565) 27.2 (690)
DIMENSIONS inches (mm) H3 H6 H7 H9 20.2 0.4 7.1 3 (512) (9) (180) (75) 22.7 7.9 (577) (200) 27.6 (702)
H10 29.7 (755) 33.1 (840) 38 (965)
D 10 (255) 10.6 (270)
33.5 (850)
27 (685) 32.1 (815)
27.4 (695) 32.5 (825)
41.3 (1050) 50.4 (1280)
11.2 (285) 14.2 (360)
H1 20.9 (530)
H2 19.7 (500)
DIMENSIONS inches (mm) H3 H6 H7 H9 20.2 0.4 7.1 3 (512) (9) (180) (75)
H10 29.7 (755)
D 10 (255) 10.6 (270)
25.8 (655)
24.6 (625)
25.1 (637)
34.6 (880)
28.3 (720) 28 (710) 38 (970)
27.2 (690) 26.6 (675) 37 (935)
27.6 (702) 27 (685) 37 (945)
D2 0.2 (4)
D3 5.7 (145)
D4 4.1 (105)
8.7 (220)
3.6 (91) 6.5 (166)
D3 5.7 (145)
D4 4.1 (105)
6.9 (175) 8.7 (220)
4.7 (121) 7 (166)
Mtg. Bolts M8
75 100 125
16.9 (430) 22.8 (580)
11.4 (290)
21 (533) 26.9 (683)
0.5 (13)
11.1 (283) 15.1 (383)
3.3 (83)
M12
Wt. Lb (kg) 70 (32) 86 (39) 106 (48) 110 (50) 172 (78) 282 (128)
460V Series NEMA 1 Hp 40 50
W1 9.4 (240) 10.8 (275)
W3 –
W4 13.5 (342) 14.9 (377)
60
D2 0.2 (4)
Mtg. Bolts M8
75 100 125 150 200 250 300 350
16.9 (430)
22.8 (580)
21 (533)
11.4 (290)
0.5 (13)
26.9 (683)
11-6
7.9 (200) 8.2 (208) 13 (333) 15.1 (383)
38 (965) 3.3 (83) 53.1 (1350) 55.1 (1400)
12.4 (315) 14.2 (360)
M12
Wt. Lb (kg) 70 (32) 82 (37) 95 (43) 97 (44) 115 (52) 174 (79) 245 (111) 337 (153)
Data subject to change without notice 9/00. © 2000 GE Fuji Drives USA