Page 131

Surface Mount W

D

W6

D1 H8

H2

D2

D7

H9

W1 W3

W5

W4

D3 D5

D6

Holes for mtg. bolts D4

H1

4-ØC

460V Series NEMA 1 Hp 400 450 500 600

W 26.8 (680) 34.6 (880)

W1 22.8 (580) 30.7 (780)

W4 – 10.2 (260)

DIMENSIONS inches (mm) W5 W6 H1 H2 24.0 21.9 53.9 52.4 (610) (555) (1370) (1330) 31.9 29.7 (810) (755)

DIMENSIONS inches (mm)

Hp 400 450 500 600

W3 11.4 (290) 10.2 (260)

D2 0.3 (6)

D3 2.0 (50)

D4 3.9 (100)

D5 1.4 (35)

D6 4.5 (115)

Data subject to change without notice 9/00. © 2000 GE Fuji Drives USA

D7 8.7 (220)

Mtg. Bolts M12

Wt. Lb (kg) 562 (255) 804 (365)

11-7

H4 52.6 (1335)

H8 3.3 (084)

H9 57.1 (1450)

D 17.7 (450)

D1 11.2 (285)

Page 132

11.3.2 Outline Dimensions Open Type Surface Mount

Through Panel Mount

H1

230V Series Hp 230V 40 50

W 13.4 (340) 14.8 (375)

W1 9.4 (240) 10.8 (275)

W2 12.8 (326) 14.2 (361)

20.9 (530) 26.8 (680)

16.9 (430) 22.8 (580)

20.1 (510) 26 (660)

W 13.4 (340) 14.8 (375)

W1 9.4 (240) 10.8 (275)

W2 12.8 (326) 14.2 (361)

W3

60

H 21.7 (550) 24.2 (615) 29.1 (740)

H1 20.9 (530) 23.4 (595) 28.3 (720)

DIMENSION Inch (mm) H2 H3 H4 19.7 20.2 0.5 (500) (512) (12) 22.2 22.7 (565) (577) 27.2 27.6 (690) (702)

H5 1 (25)

H6 0.4 (9)

D 10 (255) 10.6 (270)

1.3 (33)

0.5 (13)

11.2 (285) 14.2 (360)

D1 5.7 (145)

D2 0.2 (4)

C 0.4 (10)

Mtg. Bolts M8

75 100 125 460V Series Hp 460V 40 50

W3

60

29.5 (750) 34.6 (880)

27 (685) 32.1 (815)

27.4 (695) 32.5 (825)

33.5 (850)

H 21.7 (550)

H1 20.9 (530)

26.6 (675)

25.8 (655)

24.6 (625)

25.1 (637)

29.1 (740)

28.3 (720) 28 (710) 38.2 (970)

27.2 (690) 26.6 (675) 36.8 (935)

27.6 (702) 27 (682) 37.2 (945)

0.6 (16)

DIMENSION Inch (mm) H2 H3 H4 19.7 20.2 0.5 (500) (512) (12)

0.6 (15)

M12

8.7 (220)

H5 1 (25)

H6 0.4 (9)

D 10 (255) 10.6 (270)

D1 5.7 (145)

1.3 (33)

0.5 (13)

12.4 (315) 14.2 (360)

6.9 (175) 8.7 (220)

D2 0.2 (4)

C 0.4 (10)

Mtg. Bolts M8

75 100 125 150 200 250 300 350

20.9 (530)

16.9 (430)

20.1 (510) 39.4 (1000)

26.8 (680)

22.8 (580)

26 (660)

11.4 (290)

11-8

0.6 (16)

0.6 (15)

M12

Weight Lb (kg) 64 (29) 79 (36) 97 (44) 101 (46) 154 (70) 253 (115) Weight Lb (kg) 64 (29) 75 (34) 86 (39) 88 (40) 106 (48) 154 (70) 220 (100) 308 (140)

Data subject to change without notice 9/00. © 2000 GE Fuji Drives USA

Page 133

Surface Mount

Through Panel Mount

D

D1

W 3 or 4 dia. C

W1 W3

W4

H6

D1

D1 D2

D2

W2

W2

D2

H6

H2 H1

Alternative Through Panel Mount (bottom bracket support by customer supply.

H

C

W1

W1 W3

W5

W4

W3

W4

W H7 W4

H7

Holes for mtg. bolts H4

H4

W3 D5

4-dia.1.4 (35) Lifting bolts

D3

D6

Holes for mtg. bolts

Holes for mtg. bolts

D4

H3 H1

H1 4-ØC

460V Series Open Type Hp 400 450 500 600

W 26.8 (680) 34.6 (880)

Hp 400 450 500 600

W1 22.8 (580) 30.7 (780)

W2 26.0 (660) 33.8 (860)

W3 11.4 (290) 10.2 (260)

W4

10.2 (260)

W5 24.0 (610) 31.9 (810)

D6 4.5 (115)

C 0.6 (015)

–

DIMENSIONS inches (mm) D2 0.3 (6)

D3 2 (50)

D4 3.9 (100)

D5 1.4 (35)

Data subject to change without notice 9/00. © 2000 GE Fuji Drives USA

DIMENSIONS inches (mm) H H1 H2 H3 H4 H5 55.1 53.9 52.4 52.8 52.6 0.6 (1400) (1370) (1330) (1340) (1335) (016)

Mtg. Bolts M12

Wt. Lb (kg) 551 (250) 793 (360)

11-9

H6 1.4 (035)

H7 0.6 (015)

D 17.7 (450)

D1 11.2 (285)

Page 134

11.3.3 Outline Dimensions Open Type with NEMA 12 Heatsink

11-10

Data subject to change without notice 9/00. © 2000 GE Fuji Drives USA

Page 135

AF-300 G11 230 VAC Series HP W 40 15.04 (382)

W4

W5

W6

W7 W8 W9

W2

W3

14.41 (366)

13.39 (340)

12.83 9.45 (326) (240)

4.72 (120)

21.65 20.87 (550) (530)

19.69 (500)

20.16 (512)

16.42

15.79

14.76

14.21 10.83

5.41

24.21 23.43 (615) (595)

22.24 (565)

22.72 (577)

(417)

(401)

(375)

(361)

29.13 (740) 28.35

27.17 (690)

27.64 (702)

50 60

DIMENSIONS Inch(mm) H1 H2 H3 H4

W1

(275)

-

(137.5)

-

-

-

H

75

H5

H6

H7

H8

3.74 (95) 0.47 (12)

0.98 (25)

22.28 (566)

20.87 (530)

20.08 16.93 (510) (430)

8.46 (215)

125 29.13 (740)

28.19 (716)

26.77 (680)

25.98 22.83 11.42 (660) (580) (290)

0.35 1.67 6.69 (9) (42.5) (170) 4.13 (105)

32.09 (815)

32.48 (15.5) (32.5) (12.5) 4.02 8.46 (825) (102) (215)

W6

W7 W8 W9

H

D

D1

Fixing Wt. Fig Bolts Lb(kg)

23.43 0.43 (595) (11)

66 (30)

0.4 5.71 (10) 10.63 (145)

M6 and

81 (37)

(270)

M8

99 (45)

-

(720) 27.36 (695)

34.65 33.46 (880) (850)

C

8.86 (225)

-

26.97 (685)

2.95 (75)

H12

28.35

29.53 (750)

-

H10 H11

20.87 (530)

(720)

100 23.23 (590)

H9

0.61

1.28

1.75 8.27 0.49 (44.5) (210)

1

2

104 (47) 0.51

33.46 (850)

(13)

H9

H10 H11

11.22 5.71 0.6 (285) (145)

M6 and

161 (73)

(15) 14.17 8.66 (360) (220)

M12

260 (118)

4

AF-300 G11 460 VAC Series HP W 40 15.04 (382)

W1

W2

W3

W4

14.41 (366)

13.39 (340)

12.83 9.45 (326) (240)

W5

4.72 (120)

50 60

16.42 (417)

15.79 (401)

14.76 (375)

14.21 10.83 (361) (275)

75

5.41 (137.5) -

-

-

100

DIMENSIONS Inch(mm) H1 H2 H3 H4

23.23 200 (590) 250 300 29.13 350 (740)

22.28 (566)

20.87 (530)

20.08 16.93 (510) (430)

28.19 (716)

26.77 (680)

25.98 22.83 11.42 (660) (580) (290)

-

400 29.13 450 (740)

28.19 (716)

26.77 (680)

25.98 22.83 11.42 (660) (580) (290)

2.95 4.55 2.60 (75) (115.5) (66)

500 37.01

36.06

34.65

33.86 30.71 10.24

4.72

600 (940)

(916)

(880)

(860)

(120)

(780)

H7

H8

19.69

20.16

3.74

20.87

(550)

(530)

(500)

(512)

(95)

(530)

26.57 25.79 (675) (655)

24.61 (625)

25.08 (637)

0.47

0.98

0.35

6.69

(12)

(25)

(9)

2.85 (170) (72.5)

25.79 (655)

H12

C

D

D1

Fixing Wt Fig Bolts Lb(kg)

8.86 (225)

66 (30)

0.43

0.4

(11)

(10) 10.63 (145) (270)

5.71

M6 and

77 (35)

M8

88 (40)

-

90 (41) 28.35 (720) 27.95 (710)

27.17 (690) 26.57 (675)

27.64 (702) 26.97 (685)

8.46 (215)

(260)

H6

21.65 20.87

29.13 (740) 29.13 (740)

125 150

H5

4.13 (105) 1.56 8.27 (39.5) (210)

28.35 (720) 27.95 (710)

0.61 1.28 0.49 (15.5) (32.5) (12.5)

-

0.6 (15)

2

108 (49) 161 (73)

12.4 6.89 (315) (175)

0.51 (13)

1

M6 and M12

229 (104) 317 (144)

5

M8

551

6

55.12 53.94 52.36 52.76 0.61 1.38 0.57 0.18 6.99 8.46 5.71 54.37 0.81 0.59 17.72 11.22 and 2.76 2.56 4.33 (1400) (1370) (1330) (1340) (15.5) (35) (14.5) (4.5) (177.5) (215) (145) (1381) (20.5) (15) (450) (285) M12 (70) (65) (110)

(250)

2.95 (75)

39.37 38.19 (1000) (970)

Data subject to change without notice 9/00. © 2000 GE Fuji Drives USA

36.81 (935)

37.20 (945)

11-11

2.15 8.46 (54.5) (215)

38.19 (970)

14.17 8.66 (360) (220)

793 (360)

3

7

Page 136

Keypad Mounting Hole (Panel Cutting) Dimensions in inches (mm)

dia. 0.11 M3

2.68 (68)

0.81 (20.5)

4.53 (115)

1.69 (42)

dia. 1.38 (35)

11-12

Data subject to change without notice 9/00. © 2000 GE Fuji Drives USA

Page 137

12. RS485 Modbus RTU Serial Communications The serial interface supports operation, configuration and monitoring of drive functions through an EIA/RS485 connection. The serial interface is based on Modbus RTU protocol. This protocol allows the drive to function as an RTU slave on an industrial network.

12.1 Transmission Specification Item Physical level

Specification EIA/RS485

Transmission distance Number of nodes

500 m max. 32 total

Transmission speed Transmission mode

19200, 9600, 4800, 2400 [bits/s] Half duplex

Transmission protocol Character code

Modbus RTU Binary

Character length Error check

8 bits CRC

12.2 Connection Connection method Use shielded wire and connect to the control terminals (DX-, DX+ and SD). A termination resistor should be added between the data lines on the each end of the network. The value of the termination resistor depends on the characteristic impedance of the cable. A common value for termination resistors is 120 ohms.

Control terminals Terminal marking

Terminal name

Function description

DX+ DX-

RS485 communication data (+) RS485 communication data (–)

Input/output terminals for RS485 communication.

SD

Cable shield

Electrically floating

12.3 Serial Interface Configuration Drive function codes H30 to H39 are used to configure the serial interface parameters, such as device address, baud rate and error response.

12.4 Modbus RTU Functions The following RTU functions are supported. The maximum number of consecutive parameters for function 03 and 16 messages is 16. Code 03

Description Read Holding Registers (16 registers maximum)

06 16

Preset Single Register Preset Multiple Registers (16 registers maximum)

Data subject to change without notice 9/00. © 2000 GE Fuji Drives USA

12-1

Page 138

12.5 Drive Function Code Access All of the drive function codes are accessible through the RS485 serial interface. Drive function codes are mapped to RTU holding registers. A drive function code RTU address is 2 bytes in length. The high byte corresponds to a code that represents the drive parameter sort (F–M). The low byte corresponds to the drive parameter number within the sort (0 99). Code

Sort

Name

Code

Sort

Name

0 1

F E

Basic function Terminal function

5 6

A o

Motor 2 function Option function

2 3

C P

Control function Motor 1 function

7 8

S M

Command/function data Monitor data

4

H

High level function

For example, drive function code M11, output current, is addressed as RTU parameter number 080B hexadecimal or 2059 decimal. high byte low byte drive parameter sort code drive parameter number 12.6 Command and Monitor Data Registers The command and monitor function codes are used to control the operation of the drive and monitor the status variables through the serial interface. The command and monitor function codes are not accessible from the drive keypad interface. Drive parameter H30 and digital input signal LE must be enabled to operate the drive from the Modbus interface. If LE is not assigned to a digital input (X1-X9), the signal will default to ON. Frequency Setting Registers Address Code 1793 S01

Name Frequency command

Unit -

1797

Frequency command

Hz

S05

Variable Range -20000–20000 (max. frequency at ± 20000) 0.00–400.00

Min. unit

Read/ Write

Data Format

1 0.01

R/W R/W

2 5

Note: 1) If both S01 and S05 are set, the drive will ignore the setting of S05. 2) A data setting that exceeds the setting range is possible, but the actual action will be limited by the drive configuration. Operation command data Registers Address Code

Name

1798 1799 1804

Operation command Universal Do Universal Ao

S06 S07 S12

Unit

Variable Range

-

Min. unit

Refer to the data format [14] Refer to the data format [15] -20000–20000 (100% output at ± 20000 )

1

Read/ Write R/W R/W R/W

Data Format 14 15 2

Note: 1) Since X1–X9 are configurable input commands, it is necessary to set the functions by E01–E09. 2) The alarm reset is executed, when RST signal changes from ON to OFF even if there are no alarms. 3) Universal Do is a function that utilizes the drive’s digital outputs via communication. Function data Registers Address Code

Name

Unit

Variable range

1800 1801 1802

S08 S09 S10 s s %

0.1–3600.0 0.1–3600.0 -20.00 –200.00, 999

1803

S11

Acceleration time F07 Deceleration time F08 Torque limit level 1 (driving) F40 Torque limit level 2 (braking) F41

%

0.00, 20.00–200.00, 999

Note: 1) 2)

Min. unit 0.1 0.1 1

Read/ Write R/W R/W R/W

Data Format 3 3 5

1

R/W

5

The writing of data out of range is treated as out of range error. Use a value of 7FFFH to enter 999 for torque limit functions.

12-2

Data subject to change without notice 9/00. © 2000 GE Fuji Drives USA

Page 139

Monitoring parameter registers Address Code

Description

2049

M01

2053

M05

2054

M06

Frequency command (final command) Frequency command (final command) Actual frequency

2055 2056 2057 2058

M07 M08 M09 M10

2059

M11

2060 2061

M12 M13

2062 2063

M14 M15

2064 2065 2066 2067 2068

M16 M17 M18 M19 M20

2069 2071 2072 2073 2074

M21 M23 M24 M25 M26

2075

M27

2079

M31

2080

Unit Hz -

Range

Min. unit

- 20000–20000 (max. frequency at ± 20000) 0–400.00 - 20000–20000 (max. frequency at ± 20000) - 200.00–200.00 - 200.00–200.00 0.00–400.00 0.00–200.00

1

Read / Write R

Data Format 2

0.01

R

5

1

R

2

0.01 0.01 0.01 0.01

R R R R

6 6 5 5

0.01

R

5

1 -

R R

3 14

Actual torque value Torque current Output frequency Motor output (input electric power) Output current r. m. s.

% % Hz %

Output voltage r. m. s. Operation command (final command) Operating state Universal output terminal data Fault memory 0 Fault memory 1 Fault memory 2 Fault memory 3 Integrated operating time

V -

0.00–200.00 (inverter rating at 100.00) 0.0–600.0 Refer to data format [14]

-

Refer to data format [16] Refer to data format [15]

-

R R

16 15 h

Refer to data format [10]

-

R

0–65535

1

R

10 10 10 10 1

V -

0–1000 Refer to data format [17] Refer to data format [11] 0–64999 Refer to data format [20]

1 1 -

R R R R R

1 17 11 1 20

-

1

R

2

Hz

- 20000–20000 (max. frequency at ±20000 ) 0–400.00

0.01

R

5

M32

DC link voltage Type code Drive capacity code ROM version Transmission error processing code Frequency command at alarm (final command) Frequency command at alarm (final command) Actual frequency at alarm

-

- 20000–20000

1

R

2

2081 2082 2083

M33 M34 M35

Actual torque at alarm Torque current at alarm Output frequency at alarm

% % Hz

(max. frequency a t ± 20000) - 200.00 – 200.00 - 200.00 – 200.00 0.00 – 400.

0.01 0.01 0.01

R R R

6 6 5

2084

M36

%

0.00–200.00

0.01

R

5

2085

M37

%

R

5

M38

V

0.00 – 200.00 (inverter rating at 100.00) 0.0 – 600.0

0.01

2086

1

R

3

2087

M39

-

Refer to data format [14]

-

R

14

2088

M40

Motor output at alarm (input power) Output current r.m.s. at alarm Output voltage effective value at alarm Operation command at alarm Operating state at alarm

-

Refer to data format [16]

-

R

16

2089

M41

-

Refer to data format [15]

-

R

15

2090

M42 h

0–65535

1

R

1

2091

M43

Universal output terminal data at alarm Integrated operation time at alarm DC link voltage at alarm

V

0–1000

1

R

1

2092

M44

°C

0–120

1

R

1

2093

M45

Inverter internal air temp. at alarm Cooling fin temp. at alarm

°C

0–120

1

R

1

2094

M46

%

0.0–100.0

0.1

R

3

2095

M47 h

0–65535

1

R

1

2096

M48

Life of main circuit capacitor. Life of printed circuit board capacitor. Life of cooling fan.

h

0–65535

1

R

1

%

Data subject to change without notice 9/00. © 2000 GE Fuji Drives USA

12-3

Page 140

12.7 Data Format Specification All data in the data field of communication frame shall be represented by a 16 bit length word. 15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

16 bits binary data

Data format [1] Unsigned Integer data (Positive): Min. unit 1 Example If F15 (Frequency limit, upper)= 60Hz 60 = 003CH Data format [2] ] Example data = -20 -20 = FFECH

Integer data (Positive, negative): Min. unit 1

Data format [3] Unsigned Decimal data (Positive): Min. unit 0.1 Example: If F17 (frequency gain setting signal) = 100.0% 100.0 X 10 = 1000 = 03E8H Data format [4] Decimal data (Positive, negative): Min. unit 0.1 Example If: C31 (Analog input offset adjust, terminal12) = - 5.0% - 5.0 X 10= - 50 = FFCEH Data format [5] Unsigned Decimal data (Positive): Min. unit 0.01 Example: If C05 (multi-step frequency 1) = 50.25Hz 50.25 X 100 = 5025 = 13A1H Data format [6] Decimal data (Positive, negative): Min. unit 0.01 Example: If M07 (actual torque value)= - 85.38% - 85.38 X 100= - 8538=DEA6H Data format [7] Unsigned Decimal data (Positive): Min. unit 0.001 Example: If o05 (follow - up side ASR 1 constant) = 0.105s 0.105 X 1000 = 105 = 0069H Data format [8] Decimal data (Positive, negative): Min. unit 0.001 Example: Data = -1.234 - 1.234 X 1000 = - 1234 = FB2EH Data format [9] Unsigned Integer data (Positive): Min. unit 2 Example If P01 (Motor 1 number of poles) =2pole 2 = 0002H Data format [10]

Alarm Code

12-4

Data subject to change without notice 9/00. © 2000 GE Fuji Drives USA