Page 41
Table 4.2.1 Overview of Contents Displayed for each Level No. Level name Content 1 Operation Mode This screen is for normal operation. Frequency setting from the keypad panel and LED monitor switching are possible only when this screen is displayed. 2
Program Menu
Each function of the keypad panel is displayed in menu form and can be selected. By selecting the desired function from the list and pressing FUNC the corresponding function screen is displayed. The following DATA functions are available as keypad panel functions (menus). No. 1
Menu Name DATA SET
2
DATA CHECK
3 4
OPR I/O CHECK
Can check various data on the operating status. Can check the status of analog and digital input/outputs for the inverter and options as an I/O checker.
5
MAINTENANCE
Can check inverter status, life expectancy, communication error status, and ROM version information as maintenance information.
6
LOAD FCTR
7
ALM INF
8
ALM CAUSE
Can measure maximum and average current and average breaking force in load rate measurement. Can check the operating status and input/output status at the latest alarm occurrence. Can check the latest alarm or simultaneously occurring alarms and alarm history. Selecting the alarm and pressing FUNC displays alarm contents for DATA troubleshooting.
9 3 4
Screen for each Function Supplementary individual
Purpose The code and name of the function are displayed. Selecting a function displays a data setting screen for checking or modifying data. The code and name of the function are displayed. Select a function to display a screen for checking data. Modifying data is possible as described above by going to the data setting screen.
DATA COPY Places the function of one inverter in memory for copying to another drive. The function screen selected on the program menu appears, hence completing the function. Functions not completed (e.g., modifying function data, displaying alarm factors) onScreen function screens are displayed on the supplementary screen.
Data subject to change without notice 9/00. © 2000 GE Fuji Drives USA
4-3
Page 42
4.3 Entering Data on the Keypad Panel 4.3.1 Operation Mode The screen for normal inverter operation includes a screen for displaying drive operating status and a screen for graphically displaying the status in the form of a bar graph. The operator can switch between both screens by using the function (E45). 1) Operating Status (E45=0) 60.00
60.00
RUN
STOP
FWD
Direction of rotation = blank (no command) or FWD/REV Operating status = STOP (no command) or RUN
PRG PRG MENU F/D LED SHIFT
PRG PRG MENU F/D LED SHIFT
2) Bar Graph (E45=1) 60.00 Hz
Output frequency (maximum frequency at full-scale) Output current (200% of inverter rating at full-scale) Torque calculation (200% of motor rating at full-scale)
A % Fout/Iout/TRQ
4.3.2 Setting Digital Frequency or to display the set frequency on the LED. Data is increased or On the operation mode screen, press decreased in the smallest possible unit, depending on which key is pressed. The adjustments in data will occur rapidly if the operator holds down or . To select a digit use SHIFT and then data can be set directly. To save the frequency settings press
FUNC DATA
.
Press RESET and PRG to to return to the operation mode. If keypad panel settings are not selected, the present frequency setting mode appears on the LCD. When selecting the PID function, the PID command can be set with a process value (refer to technical documentation for details). 1) Digital (keypad panel) settings (F01=0 or C30=0) 60.00
56.89
<DIG>SET Hz> LOCAL
<DIG>SET Hz> LOCAL
60.00
RUN
FWD
PRG PRG MENU F/D LED SHIFT
50 - 400
50 - 400
F/D
F/D DATA SET STORING...
DATA SET
Frequency setting value Screen explanation Present frequency setting mode Frequency setting range Operations guide When
FUNC DATA pressed and writing
2) Non-digital setting
60.00
RUN
PRG F/D
PRG MENU LED SHIFT
60.00
Frequency setting value
<REMOTE REF> 12+V1
Screen explanation Present frequency setting mode
F/D
Operations guide
DATA SET
4-4
Data subject to change without notice 9/00. © 2000 GE Fuji Drives USA
Page 43
4.3.3 Switching to LED Digital Monitor to switch to LED monitor display. When monitored data is switched, the LED During normal operation, press FUNC DATA monitor contents are displayed. When power is turned on, the monitor contents set by the function (E43) are displayed on the LED.
E43 0 1 2 3 4 5
6 7
8 9 10 11 12
(E44 = 0) Setting frequency Setting frequency Setting frequency Output current Output voltage (specified value) Synchronous speed setting value Line speed setting value Load rotation speed setting value Torque calculation value Power consumption PID setting value PID remote setting value PID feedback value
When running When stopping (E44 = 1) (E44 = 0.1) Output frequency 1 (before slip compensation) Output frquency 2 (after slip compensation) Setting frequency Output current Output voltage (specified value)
Unit
Synchronous speed r/min.
Line speed m/min.
Load rotation speed r/min.
Torque calculation value
%
Power consumption kW
PID setting value PID remote setting value, - PID feedback value, Remarks
Hz
A V For 4 digits or more, the lasr digits are cut, with x10, x100 marked on the indicator.
± indication
Displayed only when PID is effective in PID operation selection.
4.3.4 Program Menu Screen The Program Menu screen is shown below. Only four items can be displayed simultaneously. Move the cursor with or to select an item, then press FUNC to display the next screen. DATA 1. DATA SETTING
2. DATA CHECK 3. OPR MNTR 4. I/O CHECK 5. MAINTENANCE 6. LOAD FCTR 7. ALM INF 8. ALM CAUSE 9. DATA COPY
DISPLAY
4. I/O CHECK 5. MAINTENANCE 6. LOAD FCTR 7. ALM INF
4.3.5 Setting Function Data On the Program Menu screen, select 1. Data Setting. The Function Select screen appears with function codes and names on it. Select the desired function. 60.00
RUN PRG F/D
PRG MENU LED SHIFT
PRG
1. DATA SETTING 2. DATA CHECK 3. OPR MNTR 4. I/O CHECK
FUNC DATA
F00 DATA PRTC F01 FREQ COM 1 F02 OPR METHOD F03 MAX Hz-1
Function Code
Data subject to change without notice 9/00. © 2000 GE Fuji Drives USA
60.00
60.00
60.00
4-5
Function Name
FUNC DATA
F01 FREQ COM 1 0 0-11
Data Setting Range
Data
Page 44
The function code consists of alphanumeric characters with unique letters assigned to each function group. Table 4-3-1 Function Code F00 - F42 E01 - E47 C01 - C33 P01 - P09 H03 - H39 A01 - A18 o01 - o29
Function Fundamental functions Terminal Extension Functions Frequency Control Functions Motor Parameters High Performance Functions Alternative Motor Parameters Optional Functions
Remarks
Can only be selected with an option connected
To scroll the Function Select screen rapidly, use alphabetically.
+ or
F00 DATA PRTC F01 FREQ CMD 1 F02 OPR METHOD F03 MAX Hz-1
+
F42 TRQ VECTOR 1 E01 X1 FUNC E02 X2 FUNC E03 X3 FUNC
F00 DATA PRTC F01 FREQ CMD 1 F02 PPR METHOD F03 MAX Hz-1
Select the desired function and press
FUNC DATA
+ to move the screen as a unit sorted
+
A18 SLIP COMP 2 F00 DATA PRTC F01 DATA PRTC F02 OPR METHOD to switch to the Data Setting screen.
On the Data Setting screen, the data values on the LCD can be increased or decreased in the smallest possible unit by pressing or . Holding down or causes the values to increase or decrease more rapidly. Otherwise, select the digit to be modified using and then set data directly. When data is modified, the value before modification will be displayed at the same time for reference purpose. To save the data, press FUNC DATA . Pressing cancels the changes made and returns control to the Function Select screen. The modified data will be effective in inverter operation after the data has been saved by FUNC DATA . If the data is not saved, there is no change to the inverter operation. When data setting is disabled in the case of “Data protected” or “Data setting invalid during inverter running,” make the necessary changes as indicated in Table 4-3-2 below. Table 4.3.2 Display LINK ACTIVE
Reason for No Modification Currently writing from RS-485 / RTU option to function is being made The edit enabling command function is selected using a general-purpose input terminal
Release Method Send a cancel command to function writing from RS485 RTU. Stops a “write” operation from the link For functions E01 to E09, turn data terminal 19 (edit enabling command selection) ON
DATA PRTCTD INV RUNNING
Data protection is selected for function F00. An attempt was made to change a function that cannot be changed during inverter operation.
Change function F00 to 0 Stop inverter operation
FWD/REV ON
An attempt was made to change a function that Turn FWD/REV command off cannot be changed with the FWD/REV command on.
NO SIGNAL(WE)
4-6
Data subject to change without notice 9/00. © 2000 GE Fuji Drives USA
Page 45
4.3.6 Checking Function Data Select 2. DATA CHECK on the Program Menu screen. The Function Select screen then appears with function codes and names.
60.00
60.00
RUN
FWD PRG > PRG MENU F/D > LED SHIFT
PRG
1.DATA SETTING > 2.DATA CHECK 3. OPR MNTR 4.I/O CHECK
Function code
60.00
60.00 FUNC DATA
F00 F01 F02 F03
0 *1 *1 60 Hz
Data changed from initial value
F00
DATA PRTC
FUNC DATA
0 0-1
Data
Select the desired function and press FUNC/DATA to check the function data. By pressing FUNC/DATA, the screen switches to the Data Setting screen, where data can be modified. 4.3.7 Monitoring Operating Status Select 3. OPR MNTR on the Program Menu screen to display the current inverter operating status. Use to switch between the four operation monitor screens.
RUN
60.00
60.00
60.00 FWD
PRG > PRG MENU F/D > LED SHIFT
PRG
1.DATA SETTING 2.DATA CHECK > 3. OPR MNTR 4.I/O CHECK
Fout=xxxx.xHz Iout=x.xxA Vout=xxxV TRQ=xxx%
FUNC DATA
60.00 SYN=xxxxxx LOD=xxxxxx LIN=xxxxxx
Output frequency Output current Output voltage Torque calculation method
60.00 Fref=xxxx.x Hz xxx xx xx xx
Synchronous rotation speed (r/min) Load speed (r/min) Line speed (m/min)
60.00 SV=xxxxx PV=xxxxx TLD=xxx% TLB=xxx% and
PID setting value PID feedback value Driving torque limiting setting Braking torque limiting setting
Data subject to change without notice 9/00. © 2000 GE Fuji Drives USA
4-7
Setting frequency Operation status FWD/REV: Rotating direction IL: Current limiting VL: Voltage limiting LU: Under voltage TL: Torque limiting
Page 46
4.3.8 I/O Check Select 4. I/O on the Program Menu screen. Check to display analog and digital input/output signal status for the drive and options. Use and to switch between the seven screens of data.
60.00
RUN
FWD PRG > PRG MENU F/D > LED SHIFT
60.00 Y1 Y2 Y3 Y4
60.00 PRG
60.00
1.DATA SETTING 2.DATA CHECK 3. OPR MNTR > 4.I/O CHECK
FUNC DATA
12=±xx.xV 22=±xx.xV 32=±xx.xV V2=±xx.xV
60.00 AO=xxxxV CS=xxxmA DI=xxxxH DO=xxH
60.00 P1=±xxxx0p/s Z1=xxxp/s P2=±xxxxxOp/s Z2=xxxp/s
Signal OFF.
X2 X3 X4 X5
X6 X7 X8 X9
COM FWD REV X1
Signal ON
Analog input signal
X2 X3 X4 X5
60.00
Terminal 12 input Terminal 22 input voltage (AIO option) Terminal 32 input voltage (AIO option)
DIO option I/O status
C1=xx.xmA C2=xx.xmA
60.00
Analog output voltage (AIO option) Analog output current (AIO option) Digital input terminal (HEX indication) Digital ouput terminal (HEX indication)
FMA=xx.xH FMP=xx.xV FMP=xxxxp/s
Signal OFF.
Signal ON
Input terminal status (via communication)
60.00
Output terminal status
Y5
60.00
REM FWD REV X1
Input terminal status (terminals)
X6 X7 X8 X9
Signal OFF.
Signal ON
Analog input signal Terminal C1 input current Terminal C2 input current (AIO option)
Output for meter FMA output voltage FMP output voltage FMP output frequency
PG/SY option input status Master-side A/B phase 4x frequency Master-side Z phase 4x frequency Slave-side A/B phase 4x frequency Slave-side Z phase 4x frequency
4-8
Data subject to change without notice 9/00. © 2000 GE Fuji Drives USA
Page 47
4.3.9 Maintenance Information Select 5. on the Program Menu screen. Maintenance to display information necessary for maintenance and inspection. Use and to switch between the five screens of data.
60.00
RUN
FWD
PRG > PRG MENU F/D > LED SHIFT
60.00
60.00 PRG
1.DATA SETTING 2.DATA CHECK 3. OPR MNTR 4. I/O CHECK
FUNC DATA
TIME=xxxxxH EDC=xxxV TMPI=xxxx°C TMPF=xxxx°C
60.00
TFAN=XXXXXH (25000H)
Maximum temperature of heatsink
60.00 Capacitor on PC Board accumulation time ( ): Judgement level Cooling fan operating ( ): Judgement level time
Imax=xx.xA CAP=xxx.x%
60.00 NRK=xxxxx NRR=xxxxx NRO=xxxxx
(Maximum value in hour units) (Maximum value in hour units)
> 5. MAINTENANCE
TCAP=XXXXXH (61000H)
Cumulative powered on time DC link circuit voltage Maximum temperature of inside drive
Maximum current (rms) (Maximim value in hour units) Main capacitor capacity
60.00 No. of communication errors: keypad panel No. of communication errors: RS-485 No. of communication errors: option
Data subject to change without notice 9/00. © 2000 GE Fuji Drives USA
INV=Hxxxxx KEYPAD= Kxxxxx OPTION=Pxxxxx
4-9
ROM version (drive) (30kW or more: Hxxxxx 22kW or less Sxxxxx) ROM version: keypad panel ROM version: option
Page 48
4.3.10 Load Rate Measurement Select 6. Load Rate Measurement (LOAD FCTR) on the Program Menu screen. The maximum current, average current, and average braking power during the set measuring time are measured and displayed.
60.00
RUN
FWD
PRG > PRG MENU F/D > LED SHIFT
60.00 PRG
60.00
1.DATA SETTING 2.DATA CHECK 3. OPR MNTR 4. I/O CHECK
FUNC DATA
T=3600s Imax=0.00A Iave=0.00A BPave=0.0%
5. MAINTENANCE > 6. LOAD FCTR
60.00 T=150s Imax=0.00A Iave=0.00A BPave=0.0%
Change measuring using and and
Start measuring Displays the remaining measuring tim, when reaches zero, ends the measurement.
Measuring time
FUNC DATA
60.00 T=600s Imax=0.00A Iave=0.00A BPave=0.0%
Set measuring time (Measures maximum current, average current and average braking power in 600s intervals.)
60.00 T=3600s Imax=56.4A Iave=23.5A BPave=10.4%
Display returns to initial value Maximum current Average current Average braking power (Motor rated output/100%
4-10
Data subject to change without notice 9/00. © 2000 GE Fuji Drives USA
Page 49
4.3.11 Alarm Information Select 7. Alarm Information (ALM INF) on the Program Menu screen. A variety of operating data at the time the latest alarm occurred is displayed. Use UP and DOWN to switch between the nine screens of alarm information data.
60.00
RUN
OC1
60.00
FWD
PRG > PRG MENU F/D > LED SHIFT
PRG
1.DATA SETTING 2.DATA CHECK 3. OPR MNTR 4. I/O CHECK
Fout=xxxx.xHz Iout=x.xxA Vout=xxxV TRQ=xxx%
FUNC DATA
5. MAINTENANCE 6. LOAD FCTR > 7. ALM INF
OC1
OC1
Fref=xxxx.xHz xxx xx xx xx
TIME=xxxxxh EDC=xxxV TMPI=xxxx°C TMPF=xxxx°C
Code of latest alarm (High speed blinking during alarm mode only) Output frequency at alarm Output current at alarm occurence Output voltage at alarm occurence Torque calculation value at alarm occurence
Cumulative operating hours at alarm occurence DC link circuit voltage at alarm occurence Temperature inside drive at alarm occurence Heat sink temperature at alarm occurence
Setting frequency at alarm occurence Operating status at alarm occurence FWD/REV: Rotating IL: Current limiting VL: Voltage limiting LU: Under voltage TL: Torque limiting
OC1 NRK=xxxxx NRR=xxxxx NRO=xxxxx Input terminal status at a alarm occurence (terminals)
OC1 REM FWD REV X1
X2 X3 X4 X5
X6 X7 X8 X9
SIGNAL OFF, SIGNAL ON
OC1 Output terminal status at a alarm occurence
OC1 Y1 Y2 Y3 Y4
No. of communication errors at alarm occurence: Keypad panel No. of communication errors at alarm occurence: RS 485 No. of communication errors at alarm occurence: Options
COM FWD REV X1
X2 X3 X4 X5
Input terminal status at a alarm occurence (communication) X6 X7 X8 X9
SIGNAL OFF, SIGNAL ON
SIGNAL OFF, SIGNAL ON
Y5
OC1
OC1 5=xxx 4=xxx 3=xxx 2=xxx
Previous alarm Before previous alarm Two times before previous
0/1 =xxx -1 =xxx -2 =xxx -3 =xxx
Multiple alarms (Simultaneously occuring alarms) Alarm code
Up to four alarm codes can be dosplayed simultaneously.
Data subject to change without notice 9/00. © 2000 GE Fuji Drives USA
4-11 xxx xxx xxx xxx
Lastest alarm No. of occurences Alarm history No. of occurences Updated at alarm occurence. If the cause of an alarm is the same as the previous one, only the number og occurences is incremented.
Page 50
4.3.12 Alarm History and Factors Select 8. Alarm Cause on the Program Menu screen, to display the alarm history. Press FUNC/DATA to display troubleshooting information for the alarm selected.
60.00
RUN
FWD
PRG > PRG MENU F/D > LED SHIFT
60.00
60.00 PRG
1.DATA SETTING 2.DATA CHECK 3. OPR MNTR 4. I/O CHECK
FUNC DATA
0.1=xxx xxx -1=xxx xxx -2=xxx xxx -3=xxx xxx
5. MAINTENANCE 6. LOAD FCTR 7. ALM INF > 8. ALM CAUSE
OC1 xxxxxxxxxxxxx xxxxxxxxxxxxx xxxxxxxxxxxxx xxxxxxxxxxxxx
Alarm code of the selected alarm Alarm occurence factor of the selected alarm
Lastest alarm Alarm history
60.00
FUNC DATA
5=xxx 4=xxx 3=xxx 2=xxx
Multiple alarms (simultaneously occuring alarms)
0.1=xxx xxx -1=xxx xxx -2=xxx xxx -3=xxx xxx alarm occured
4-12
Move the cursor using and to select one of the
Data subject to change without notice 9/00. © 2000 GE Fuji Drives USA