Spec sheet · GE
Control Catalog, Section 6: IEC Manual Motor Starters
Spec sheet48 pagesPDF 16 MB
GE Control Catalog section on Surion IEC manual motor starters (GPS1 and GPS2 series), with selection tables, accessories and specifications.
Covers · 6 models
The models it covers
Summary
What is in it
Section 6 of the GE Control Catalog, covering Surion GPS1 and GPS2 IEC manual motor starters, including catalog numbers such as GPS1BHAA and GPS2BHAP. It gives an overview of the range, a selection guide, front, side and group mounted accessories, enclosures, starters integrated with AC or DC operated contactors, enclosed starters, outline drawings, accessory wiring diagrams, short circuit ratings, specifications and time current curves.
Its parts
- Overview
- Selection Guide
- Accessories
- Enclosures and Enclosure Accessories
- Integrated with Contactor, Open
- Enclosed
- Integrated with Contactor, Enclosed
- Outline Drawings
- Wiring Diagrams – Accessories
- Short Circuit Current Rating, Rating Breaking Capacity
- Type 2 Short Circuit Rating, Individual Group and Combination Starters
- Specifications
- Time Current Curves
From the sheet
Key facts from this sheet
Each line names its page in the PDF.
This is Section 6 of a GE Control Catalog, revision 4/16, on Surion IEC manual motor starters: the GPS1BS and GPS1BH series in 45 mm frames and the GPS2BH series in 55 mm frames, including the GPS1BHAA and GPS2BHAP. It gives selection tables, accessories, enclosures, short circuit ratings and specifications for choosing and applying a starter.
- Product type
- Surion IEC manual motor starters with rotary operator, high interruption capacity: GPS1BHAA in the 45 mm frame, GPS2BHAP in the 55 mm frame p. 6
- Current range
- GPS1: 0.1A to 32A, motors up to 30hp at 600V; GPS2: up to 63A, motors up to and including 50 hp p. 2
- Frame width
- GPS1: 45mm, up to 32 amps; GPS2: 55mm, rated to 63 amps p. 2
- Operator and trip
- OFF-TRIP-ON operator, padlockable in OFF; Class 10 overload trip; trip test; single-phase sensitivity p. 2
- Combination use
- The catalog states GPS1BH* and GPS2BH* were evaluated by UL as manual self-protected combination starters (Type E), 277/480 and below p. 4
- Combination rating
- GPS1BH: 50kA short circuit interruption rating for 277/480V and below in combination installations p. 2
- Voltage
- The catalog states the UL, cUL listing allows use in installations up to 600 volts p. 3
- Ambient compensation
- -20°C to +60°C p. 2
- Mounting
- 35mm DIN rail p. 2
- GPS1 ratings
- GPS1: 32A max. rated current, 20 Hp @ 460V, 15 kW @ 400V, 3 poles p. 46
- Terminal torque
- GPS1: 2.0 Nm/18 lb. in.; GPS2: 4.0 Nm/36 lb. in. p. 46
- Contact accessories
- Front auxiliary contacts GPAC_ _FBA; side auxiliary contacts GPAC_ _LLA/GPAC_ _LRA; side alarm/auxiliary GPAD_ _ _ _LLA; side short circuit alarm GPAE11LLA p. 7
- Handle operators
- GPA_HA_ handle operators work GPS1BH_ _ and GPS2BH_ _ through a panel door; shaft depth 139.8-289.8 mm (GPS1BH) or 161-311 mm (GPS2BH) p. 10
- GPS2 terminal covers
- GPS2: GPAPTP2A terminal covers p. 10
What this sheet walks you through
- Choosing the starter current range from motor full load current and service factor p. 5, 6
- Wiring a starter for a single-phase motor p. 5
- Applying starters in individual and group installations p. 3
- Assembling combination starters with contactors, bases and links p. 4
- Adding front and side mounted auxiliary and alarm contacts p. 7
- Looking up short circuit ratings and maximum fuse and breaker sizes by product number p. 44
- Picking contactor and link sizes for Type 2 coordination p. 45
- Operating a starter through a panel door with an external handle p. 10
Good to know
- In panels with multiple motor circuits, combination use needs a main disconnect in sight and within 50 feet. p. 4
- The GPAE11LLA short circuit alarm may not be used with non-metallic enclosures, because of reset button interference. p. 7
- Contactors used with the starters must not be applied above their nameplate HP/current ratings. p. 3
- Maximum voltage for combination control is 277/480. p. 6
- Single-phase use requires all three overload legs to be energized. p. 5
Questions this sheet answers
How do I wire a Surion manual motor starter for a single-phase motor?
Connect terminal T2 to L3 with a separate conductor, connect power to L1 and L2, and apply the load between T1 and T3. p. 5
What current setting do I use for a motor with a service factor under 1.15?
Multiply the normal full load current by .9; for a service factor of 1.15 or greater, use the motor full load current. p. 5
Can the GPS1BH and GPS2BH starters be used without upstream branch circuit protection?
As Type E combination starters at 277/480 and below, the catalog says they may control motors without additional upstream branch circuit protection, in motor circuits only. p. 4
What does the GPAE11LLA short circuit alarm accessory do?
It indicates that the starter tripped on a short circuit rather than an overload, and it includes a manual reset. p. 4
What current range does the GPS1 line cover?
0.1A to 32A, for motors up to 30hp at 600V; the GPS2 series extends the range to 63A. p. 2
Contents
Chapters and sections
Each line opens the PDF at its page.
- Section 6: IEC Manual Motor Starters1
- Table of Contents......6-11
- Overview......6-22
- Selection Guide......6-55
- Accessories – Front Mounted......6-77
- Accessories – Side Mounted......6-77
- Accessories – Group Mounted......6-99
- Accessories – External Handle Operators......6-1010
- Accessories – Other......6-1010
- Accessories – Integrated Starter Components......6-1111
- Enclosures and Enclosure Accessories......6-1313
- Integrated with Contactor, Open, AC Operated Contactors, Standard Interruption Capacity......6-1515
- Integrated with Contactor, Open, DC Operated Contactors, Standard Interruption Capacity......6-1616
- Integrated with Contactor, Open, AC Operated Contactors, High Interruption Capacity......6-1717
- Integrated with Contactor, Open, DC Operated Contactors, High Interruption Capacity......6-1818
- Integrated with Contactor, Factory Installed Accessories......6-1919
- Enclosed, Non-metal Enclosures, Standard Interruption Capacity......6-2020
- Enclosed, Factory Installed Accessories......6-2121
- Enclosed, Metal Enclosures, High Interruption Capacity......6-2222
- Enclosed, Factory Installed Accessories......6-2323
- Integrated with Contactor, Enclosed, AC Operated Contactors, High Interruption Capacity......6-2424
- Integrated with Contactor, Enclosed, DC Operated Contactors, High Interruption Capacity......6-2626
- Integrated with Contactors, Factory Installed Accessories......6-2828
- Outline Drawings......6-3030
- Wiring Diagrams – Accessories......6-4242
- Short Circuit Current Rating, Rating Breaking Capacity......6-4444
- Type 2 Short Circuit Rating, Individual Group and Combination Starters......6-4545
- Specifications......6-4646
- Time Current Curves......6-4747
The whole text · 5 parts
Read the sheet here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
The file