Page 111

B375, 4-20 mA Analog Input Module Block Diagram

B375, 4-20 mA Analog Input Module Terminal

Numbering and Input Connections I

Environment Operating Temperature

/

0 to 60°C

Humidity

0 to 95% (noncondensing)

Shock

15 G for 11 ms

Vibration

0.625 G, 50-500 Hz

EMI

M I L-STD-461 B

Ml

Helmholtz Gauss)

RFI

FCC Class A

Surge withstand capability (SWC)

IEEE STD 472-1974 and ANSI C37.90-1974 (2500 V, 1.5 mHz for 6 ps) Coupled coil (20

Dimension (W x H x D)1.63 in x 10.50 in x 5.50 in (41.40 mm x 266.70 mm x 139.70 mm)

J

Weight

1 lb (0.45 kg)

Termination

Screw Terminals; Fanning Strip Compatible

Wire Size

Two #14 AWG (max)

Construction

Lexan

Indicator

OUT OF RANGE

NUMERICAL VALUE 999

-

750

-

500

-

250

-

-----

--A

EACH NUMERICAL EQUALS 4V/l6pA

__-----

VALUE

0 I

2

3

4

5

6

VOLTS

4

8

12

16

20

24

MILLlAMPS

Relationship Between Numerical Value and Voltage/Current Inputs

Page 112

,

Network No. 1 - Simple Set Point Control

Network #l compares the value from an analog input in register 3001 with a preset value in register 4009. If the input value is greater than or equal to the preset value, coil 0001 is ON. Conversely, if the input is less than or equal to the preset value, coil 0002 is ON. This comparison is performed on every Micro-84’” scan.

Network No, 3 l

“Dead Band” Set Point Control

Network #3 will turn ON coil 0001 when the analog input value is less than or equal to the preset value in register 4009. Coil 0002 is ON when the input value is greater than or equal to the preset in register 4011. The preset value in register 4011 is greater than the preset value in register 4009. Values between these will turn both coils OFF.

Natwork No. 2 . Set Point Control

Network #2 performs a similar set point function as Network #l, but both coils do not go ON when the input value in register 3001 is equal to the preset value in register 4009. Coil 0002 is ON only when the input is less than the preset value. Greater than or equal input values turn on coil 0001. Alternatively, a normally closed 0002 contact positioned prior to coil 0001 (while removing contact 0001) will prevent equal values from turning ON coil 0001.

Network #4 performs the inverse of Network #3. Coil 0001 is ON only when the analog input is between or equal to preset values in registers 4009 and 4011. The preset value in register 4011 is greater than the preset value in register 4009.

+

GOULD Electronics

Page 113

PI-J3/8-Uul nev u

J378 Modem DATA SHEET Y

The J378 Modem allows shielded cable network.

a J375 Modbus @ Adapter

FEATURES Allows short-haul data transfer plant Micro 84’” controller Allows transmission twisted pair cable to be used with a 4-wire, twisted pair, fully for in- over a 4-wire,

Designed for harsh industrial environment Low cost Easy to install Operates asynchronously to 19,200 bps at speeds up

Uses frequency shift keying (FSK) to maximize noise immunity Tolerates dB a maximum

Operates mode in half-duplex signal loss of 35 transmission

Does not require an additional power supply Monitors LEDs certain

EIA control

Mounting and packaging Micro 84 l/O modules Compatible

GENERAL signals similar via to with Gould J478 Modem

DESCRIPTION

The J378 Modem allows a J375 Modbus Adapter to be used with a 4-wire, twisted pair cable network, when the cable is used in a multipoint environment. It attaches to the right side of the J375 and receives both power and W-232-C signals from the adapter. It connects to the 4-wire, twisted pair cable by way of a terminal strip on the front of the modem.

i

The J378 uses FSK modulation that is compatible with the J478 Stand-alone Modem. The J378 meets or exceeds the specifications for the J478 Modem, except for voice communications. The J378 does not have voice communication capability.

The J378 attaches to the right side of the J375 Modbus Adapter through the RS-232-C port on the adapter. Attaching the modem to the adapter dedicates for use by the modem.

the RS-232-C port

The J378 interfaces with the Modbus twisted-pair cable network through four terminals on the front of the modem. You simply connect the twisted-pairs directly to the terminals on the front of the unit. The terminals are clearly marked as to which is receive and which is transmit. The J378 supports the Modbus 4-wire, twisted pair cable network only. The J378 uses four LED indicator display operating status. XMIT D RCV D CD RTS lights to

(Transmit Data to cable) (Receive Data from cable) (Carrier Detect from cable) (Request to Send from J375 Adapter) 1

=!!!!!!GOULD Nectronics

Page 114

SLAVE PROGRAYYISLE CONTROLLER WITH MODEM m J375

J37S

7 ‘ t,:‘!::?:::

P3ro

Showing

Typical Modbus Network Placement of J378 Modem Within Network

*ADAPTER CAN BE MOUNTED EITHER ABOVE OR BELOW THE COHTROLLER AS A STAND-ALONE DEVICE

Two Possible

Mounting

Configurations

SPECIFICATIONS Electrical

Characteristics

Mark Frequency

50 kHz

Space

80 kHz

Frequency

Maximum

Data Rate

Form of Modulation

15,000 ft*

Transmission

Four conductor, fully shielded twisted-pair cable (i.e., Belden 8777)

Media

20 kHz Frequency Keying

Allowable Signal Attenuation

35 dB

Max. No. of Drops

32*

Shift

Environment Ambient Temperature Operating Storage Humidity

Max. Cable Length

Type of Transmission

Asynchronous

*Main cable, drop lengths, and number of slaves are all inter-related parameters. For instance, the 15,000 ft. maximum length can be increased if less than 32 slaves are used. Dimensions

0’ to 60°C -5OOto +85OC 0 to 95% (noncondensing)

(W x H x D) 1.63 in x 10.50 in x 5.50 in (41.40 mm x 266.70 mm x 139.70 mm)

Weight 1 lb, 5.5 oz (0.610 kg)

NOTES 1. Install as the last module in the l/O structure. 2. Install anywhere within the range of the Micro 84 cable (cable is 6 ft. long and interchangeable with P370 cable).

-i

GOULD Electronics

Page 115

PI-M84A-002

Rev A

Micro 84/Pl90 Programmer/Tape Loader DATA SHEET ,

The Gould Modicon Programmer/Tape Controller

Loader cartridge permits programming of the Micro 84 Programmable by the P190 CRT Programmer.

FEATURES searching. Network

Programmer and Tape Loader Functions

Editing offers the additional capability of deleting, replacing, exchanging, compressing, and expanding networks.

Element Editing Network

Editing

Four Tape Loader functions

4 x 7 Ladder Logic Display Element Status Display

1. 2.

Partial and Full Reference Screens Network

Create, Replace, Exchange and Delete

Program Documentation

7j

Record the Micro 84 memory onto the P190

3.

Compare the Micro 84 memory with the P190 tape.

4.

Write the Micro 84 memory onto the program track.

GENERAL DESCRIPTION

The Load function allows the user to construct new programs by loading and later editing selected

The Gould Modicon Programmer/Tape Loader cartridge, used in conjunction with the Micro 84 Programmable Controller, the J375 Modbus Adapter, and the P190 full-family CRT Program-networks from a previously prepared program. Record enables the user to preserve a copy of the program on a P 190 tape for later use. A program may also be recorded on a Micro 84 program pack by Writing the program pack function.

mer, provides programming functions for program preparation, editing, documentation, debug, and system maintenance.

With Programmer/Tape

Loader, the user can perform local programming functions on the plant floor or expand the Micro 84 controller’s versatility by performing remote programming and tape loading operations. In addition, it provides control for starting and stopping the Micro 84 controller, reporting its configuration, and writing the program pack. There are two programming options: Element Editing and Network Editing. Element Editing permits the user to make entries and/or changes directly into the Micro 84 controller’s memory. Network Editing permits the user to make changes in the PI90 programmer’s memory before making changes in the Anicro 84 controller’s memory. With Network Editing, the user can experiment with network changes while preserving existing logic. Both editors can read existing networks, create new networks, edit networks, disable and force elements, report full or partial reference tables, j

Load from the P190 tape to the Micro 84.

tape.

Logic Expand and Compress Program Load, Record and Compare allow the user to:

report coil usage tables, and perform element

Compare is used to verify that the Micro 84 controller’s memory contains the same program as that on a P190 tape. Comparison may be performed on all memory, selected networks, or selected registers. The user may also select a log-and-pause or continuous-log mode for reporting miscompares.

The Programmer/Tape Loader cartridge plugs directly into the PI90 tape transport. Local use requires a Gould Modicon J375 Modbus Interface. Remote use requires a J375 plus Gould Modicon J378 and J478 modems (or commercial equivalents). A P190 cable (either AS-W806-OXX or AS-W364-OXX) provides the communications link between the PI90 and J375. When using a J375, the user must set port parameters and address selection on both the J375 and P190 programmer. A hard copy printout of the P190 programmer’s CRT screen is obtained by connecting an RS-232-C compatible printer to the PI 90 programmer’s second communications port.

I)

GOULD

Page 116

LOCAL

PROGRAMMING

MA-liO5-000 CABLE

SPECIFICATIONS Operations Start PC stop PC Program Tape Loader Attach Detach Clear PC. (logic and/or references) PC Configuration

Network Editor (only) Create Network Delete Network Dummy References or Presets Replace Network Flip Network Exchange Network Expand/Compress Network

Element and Network Editor Read Network Edit Network Force On/Off Enable/Disable Hold/Release Reference Display Coils Used Full Reference Display Partial Reference Display Search Display Search List Print (any PI90 display)

Tape Loader Load Record Compare Program Pack

Compare PC All Memory Selected Networks Selected Registers Error Halt Mode Error Log Mode Maximum Miscompare Count

Media 3 “son” ready-to-use cartridge tapes (nonreproducible) Scotch DClOOA or equivalent.

Load PC All Memory Selected Networks Selected Registers Record PC Set Title Set Date Set Serial Number

-i

GOULD Electronics

Page 117

MICRO

84 SELF-STUDY

FEATURES l l l l l l l

Low cost Convenient scheduling Use with or without a CM84A I/O Simulator Frequent progress checks Written / lab exercises Audio/text format Educationally tested and proven

COURSE

DESCRIPTION

Audience

Objectives

Designed for the student wishing to learn how to use the Gould Modicon Micro 84 and the fundamentals of automatic control theory including ladder logic diagramming.

The student successfully completing this course should be able to: l l

Prerequisites The student taking this course should be able to: l l c

Apply basic electricity theory Use common hand tools for cabling l l

Plan an automatic control system using the Modicon Micro 84 as system base. Install and cable all modules of the Micro 84 system. Write, debug, and implement ladder logic programs for the Micro 84. Take remedial action if the system fails.

Duration

Media

Individual learning time is approximately 15 hours.

Instructional text supported by audio tapes and reference cards.

TOPICAL l l l l l

OUTLINE

Self-Study Program Overview Automatic Control Methods Control System Planning Micro 84 PC System Micro 84 Application l l l l l l

MODEL

Register and Analog I/O Progam Elements Programming the Micro 84 Programming Techniques Micro 84 Troubleshooting Modbus Interfacing

AND PRICE $200.00 s 75.00

SS-MSQA-SPl SS-lOOO-TRH ORDERING

Micro 84 Self Study Tape Recorder

INFORMATION:

Call (603) 893-0400 X3101 to place order. Orders will be shipped within 10 working days from receipt of check or purchase order. State and local taxes must be included with order.

-ii= GOULD Electronics

Page 118

INDEX A

AC Power Connector, 3-6 Addition, 7-9 A Key, 6-7 Arithmetic Operations, 78 6

G

Glossary, C-l H HOLD Key, 6-9 Holding Register, 7-9 Horizontal Connector, 7-6

0 Key, 6-7 I

C Call Register A, 6-7 Call Register B, 6-7 Cascading, 78 Change Register A, 6-8 Change Register B, 6-8 Checkout, 41 CLEAR Key, 6-9 Coil, 7-5 COMM-OK, 65 Component Mounting, 3-6 Configuration, 2-l Connectors, 7-6 Connections, 36, D-l Contact, 7-5, 76 Continue SRCH (Search) Key, 6-11 Controller, 33 Control System Maintenance, 43 Cursor Control Keys, 6-6 Counter, 7-7 D Data Display, 6-3 Data Sheet, D-l Define A, 6-7 Define 6, 6-7 Diagnostic Tests, 4-1 Dimensions, 3-3 DISABLE Key, 6-14 Discrete Input, 7-1 Discrete Modules, 5-2, D-l Display Area, 6-2 Double-Node Logic Element, 6-12 Dump, 81 Dump Memory, 8-2 E Element Display, 6-3 Element Status, 6-3 ENTER Key, 6-11 Enter Mode, 6-2 Enter Status, 6-5 ENTER VALUE Key, 6-13 Entry Rules, 6-13 Environmental Requirements, 3-3 Error Codes, A-l Error Mode, 6-15 Examine Mode, 6-9, 6-15 Examine Status, 65 Examples, B-1 Exit Supervisor, 68 F FORCE Key, 6-14 Function Keys, 6-7

Indicating Lights - Controller, 3-3 Indicating Lights - l/O Module,. 3-5 Input Registers, 7-4 Input/Output Modules, 2-2 Installation, 3-1 l/O Modules, 5-2 l/O Module Addressing, 3-8 l/O Wiring, 3-7, D-l Interlocks, 3-5 Internal Register Reference Numbers, 7-4 K Keyboard, 65 Function, 6-7 Cursor Movement, 6-7 Logic Element, 6-3 Numeric, 6-6 L Ladder Logic Programming Pad, 7-3 Liquid Crystal Display (LCD), 6-l Load, 8-2 Logic Element, 7-l Logic Elements, 5-l Logic Element Entry Rules, 6-13 Logic Element Keys, 6-6 M Memory Protect Keylock Switch, 6-14 Memory Size, 3-2 Module Addressing, 2-2 Motor Control Seal Circuit, B-l Mounting, 3-6 N Network, 5-1, 7-l Network Display, 6-4 NETwork Key, 6-10 Node, 61, 7-l Node Display, 6-2 Numeric Keys, 6-2 0 Oscillator, B-2 Output Register Reference Numbers, 7-4 P

Power Down Sequence, 4-2 Power Flow, 7-2 Power Light, 3-3 Power Requirements, 3-3

Power Supply, 2-1 Power Up Sequence, 4-1 Preset, 7-9 PREVious NETwork Key, 6-10 PREVious REF Key, 6-10 Processor, 2-l Programming, 7-1 Program Pack, 2-4, 8-1 Programmer Operating Modes, 6-l Programmer Operations, 6-14 P370 Programmer, 6-l P371 Program Pack, 23, 8-l R Real-Time Clock, B-3 Reference Data Area, 6-2 Reference Display, 6-3 Reference Numbers, 7-3, 7-4 REF Key, 6-10 Register Contents, 6-3 Register Modules, 5-2, D-l RESET Key, 69 Result Register, 7-9 Rules, 6-13 RUN Light, 3-3 S Scan, 5-l Scan Time, 5-l Search Types, 6-11 Sequencer, 7-9, B-5 Sequencer Reference Numbers, 7-4, 7-10 SHIFT Key, 6-7 Single-Node Logic Element, 6-12 Specifications, 3-2 SRCH (Search) Key, 6-11 Start Controller, 6-8 Starting the Controller, 4-l Status Indicators, 6-4 Stop Controller, 6-8 Subtraction, 7-9 Supervisory Mode, 615 System Block Diagram, 5-l System Checkout, 4-3 System Checkout, 4-l System Requirement, 3-l T Terminator Plug, 3-5 Theory of Operation, 5-l Timers, 7-6 Time Delay Circuit, B-4 U User Control Devices, 3-7 User Memory, 2-1 V Vertical Connector, 7-6 W Weight, 3-3 Wiring, 3-6, D-l

Page 119

I)

GOULD

INDUSTRIAL

AUTOMATION

SYSTEMS

PUBLICATIONS COMMENT FORM

Document Part Number

ML-M~~*-USE rev

1

Title Micro 84 Programmable Cont. User’s Manual We are constantly striving to improve the content and usability of our technical documents. You can help us by answering the questions below and mailing this form to us. Also, if you find any errors or have any suggestions for improvement, please let us know. How do you use this document? q

Introduction to the product q

Classroom resource q

Self-study

0

Programming Procedures

0

Advanced programming techniques q

Operating instructions

0

Reference

0

Other

How did you get this document? 0

Received with equipment

0 Ordered from Gould PC Division

0

Received from Sales or Customer Service Representative

0

Do not know

0

Other

Please rate this document.

Very Good

Fair

Poor

Technical Accuracy

- Does the system work the way it is described in the manual?

0

0

0 cl

0

Readability

- Is the manual easy to read and understand?

0

Cl

0

0

Cl

Clarity

- Are the instructions easy to follow?

I2

0

0

0

0

Examples

- Are the examples helpful and realistic? Are there enough examples?

0 cl

0 0 cl 0

0 0

0

Organization

0 0

II cl

13 0

0 cl

0 q

Illustrations

- Is the organization of the manual logical? Is it easy to find what you are looking for? - Are the illustrations clear and useful?

Physical

- What did you think of the layout,

Attractiveness

~~

Excellent

Good

” printing, binding, etc?

~

Are there any terms or concepts that are not defined clearly?

Y 0

N 0

Y 0

N El

If so, what are they?

After reading this document, are you able to use the equipment?

What errors did you find in the manual? (Please include page numbers. Attach an extra sheet if necessary.)

Do you have any comments or suggestions?

Name

Street

Title

City

Dept./Mail

Stop

Company Thank you for your help.

State/Country Zip Code

Telephone

Page 120