Summary

What is in it

Gould user's manual for the Modicon Micro 84 Programmable Controller, a microprocessor-based controller made to replace relay control systems. It describes the system components (controller, B300 series I/O modules and programming devices), installation and wiring, system checkout, theory of operation, the P370 Programmer and its keyboard, ladder logic programming with contacts, coils, timers, counters, arithmetic and sequencers, and the P371 Program Pack, with appendices on error codes, program examples, terms and I/O module data sheets.

Its parts

  1. Introduction
  2. System Configuration
  3. System Installation
  4. System Checkout
  5. Theory of Operation
  6. P370 Programmer
  7. Programming
  8. Using the P371 Program Pack

From the manual

Key facts from this manual

Some pages are scans or cannot be read; this says only what the readable text supports. Each line names its page in the PDF.

Gould (Modicon) user's manual, Rev I of April 1987, for the Micro 84 Programmable Controller: the M84A mainframe, its I/O modules, the P370 Programmer and the P371 Program Pack. It covers configuring, installing, checking out and programming a Micro 84 system, with error codes and I/O module data sheets.

Read for this summary: pages 1 to 8, 11 to 13, 16 to 17, 20, 23 to 24 and 57 to 59 of 124.

Device
Programmable controller: M84A mainframe (processor, user memory, power supply), up to fourteen I/O modules and a P370 Programmer p. 16
Memory sizes
M84A-001 (1K): 8 I/O modules (basic system), 9 networks; M84A-002 (2K): 14 I/O modules (expanded system), 18 networks p. 16
I/O capacity
Up to 112 input and output points; eight points per module; up to fourteen modules p. 12
Power supply versions
AC (AS-M84A-001 or -002): 115 VAC or 220 VAC, jumper selectable; DC (AS-M84A-101 or -102): 24 VDC p. 11
Power ranges
AC: 115 or 220 VAC, 47 to 63 Hz, 50 watts max; DC: 24 VDC, +20%, -15% (20.4 to 28.8 VDC) p. 17
Programming devices
P370 Programming Panel on a cable to the controller housing; P371 Program Pack for transferring programs p. 4, 11
Front panel
Five-screw power terminal strip; POWER and RUN lights p. 17
Mounting
Metal housing that screw mounts in a standard 8 in. deep NEMA rack or on a wood panel p. 17
Program retention
The program is kept through power failure or power off p. 11
Basic or expanded
A serial number ending in A marks an expanded system; without it, a basic system p. 12
Expanded system rules
Up to 14 discrete modules (eight input or eight output at most); 2 analog or register input and 4 output modules, mounted right of the discrete modules p. 13
Analog modules
B374 4-20mA analog output, B375 4-20mA analog input, B373 analog input p. 12
Error codes
E plus a code from 00 to 99 in the data display; codes with an asterisk are controller errors p. 57
Arithmetic
Addition and subtraction p. 11

What this manual walks you through

  • Configuring I/O modules for basic and expanded systems p. 12, 13
  • Mounting the controller and interlocking the I/O modules p. 20
  • Wiring AC or DC power to the controller p. 20
  • Starting the controller and what happens at power up and power down p. 23, 24
  • Reading and clearing error codes p. 57, 58, 59
  • Finding a faulty I/O module after an I/O error p. 57
  • Storing and loading programs with the P371 Program Pack p. 4, 7
  • Programming timers, counters, arithmetic and sequencers p. 7

Good to know

  • At power up, AC output modules may falsely trigger loads such as latching relays and fast-acting solenoids for one-half cycle. p. 23
  • Remove power from the controller first; cutting the I/O power first or at the same time can store incorrect data. p. 24
  • Separate power sources are recommended for the controller and the I/O modules. p. 20
  • Reversed DC polarity blows the power supply fuse without damaging the supply, controller or I/O modules. p. 17
  • Before reloading a program into the same controller, remove and reinsert the P371 Program Pack to avoid false error conditions. p. 13

Questions this manual answers

How many I/O points can a Modicon Micro 84 handle?

Up to 112 input and output points, on up to fourteen modules of eight points each. The 1K M84A-001 takes 8 modules and the 2K M84A-002 takes 14. p. 12, 16

What does error 61 mean on a Micro 84?

An error in the controller's I/O section. Check the terminator plug, then remove the I/O modules and reinstall them one at a time to find the faulty one. p. 57

What power does the Micro 84 controller need?

It depends on the supply: AC versions (AS-M84A-001 or -002) run on 115 VAC or 220 VAC, set by a jumper; DC versions (AS-M84A-101 or -102) run on 24 VDC. p. 11, 20

How do I clear an error on the Micro 84 P370 programmer?

Errors marked with an asterisk are cleared with SHIFT/RESET, the others with RESET; SHIFT/RESET clears all errors. p. 57

The whole text · 13 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 101-10
  2. Pages 11 to 2011-20
  3. Pages 21 to 3021-30
  4. Pages 31 to 4031-40
  5. Pages 41 to 5041-50
  6. Pages 51 to 6051-60
  7. Pages 61 to 7061-70
  8. Pages 71 to 8071-80
  9. Pages 81 to 9081-90
  10. Pages 91 to 10091-100
  11. Pages 101 to 110101-110
  12. Pages 111 to 120111-120
  13. Pages 121 to 124121-124

The file

Revision and size

RevisionML-M84A-USE Rev I, April 1987
PublisherGould Inc.
Pages124
PDF6.0 MB
TextText from the PDF itself; pages 1, 16, 32 and 44 are scans, read by OCR, which may hold reading errors.

The first pages · 3 of 124

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 124
Page 2
Page 2of 124
Page 3
Page 3of 124