Page 81
PI-B354-001
Rev C
B354=001 I 220 VAC Output Module DATA SHEET The Gould
B354-001
Output
Module consists of eight independent and isolated
220 VAC output v circuits.
FEATURES Eight independent Circuit isolation
Field side status Transient
220 VAC outputs of 1500 VAC indicators protection
Surge withstand capability pliance with IEEE 472-1974 C37.90A in comand ANSI
Optional Fanning Strip permits module removal without disturbance to field wiring UL listed and CSA certified High current per output (2 Amp)
Designed for harsh plant floor environments
GENERAL d
DESCRIPTION
The Gould B354-001, 220 VAC Output Module converts logic signals used within the Micro 84’” Programmable Controller into 8 independent 220 VAC outputs. Each output is capable of loads up to 2.0 amperes. The module uses 8 triac switches to control loads connected to an external power source. These switches are designed to withstand the high surge currents typical of industrial loads. Each output is electrically isolated from the controller by an optical coupler. This enables the module and controller to withstand the severe voltage transients prevalent in an industrial environment. Both IEEE and ANSI standards for surge withstand capability (SWC) tests are fully satisfied.
The output circuits are divided into two groups of four outputs each. Each group is driven by a separate voltage source. A neon , lamp connected to each circuit’s field side ri displays the ON/OFF status of the output. The lamp indicates the output’s true state.
The module is housed in a light weight, durable LEXAN case. A structural chimney within the module provides flow-through convection cooling and protection from moisture build-up. Self-contained mounting brackets eliminate the need for special l/O housings. A termination connecter shipped with the Micro 84 is required when using the module at the extreme right bus location. The module is also compatible with the B355 Input Module without the use of additional components. User connections are made to a standard screw terminal strip. The strip is compatible with an optional Fanning Strip (P/N 0212-012) which allows quick module replacement without disturbing field wiring. Data bus connections are made with standard interface connectors. These connectors allow the B354 module to be placed in any location in the l/O structure without interference to other module operation.
=i!> GOULD Electronics
Page 82
TRIAC
SNUBBER
OUTPUT
OUTPUT INDICATOR
NEUTRAL
6354 220 VAC Output Module Terminal Numbering and Connections
B354 220 VAC Output Module Simplified Schematic
SPECIFICATIONS Load Ratings
Circuit Characteristics
Electrical Characteristics
Topology:
2.OA (max) per output (iO.OA max for 8 outputs)
ON Current: Load Current
(Min): 50 mA
Surge Current:
50A (max) for 1 cycle (60 Hz)
Working
Voltage:
180 to 260V rms 47 to 63 Hz
Transient
Voltage:
300V rms (max) for 10 sec. 400V rms (max) for 1 cycle
ON Voltage Drop:
1.2V rms at 2A (typical)
OFF Current:
5 mA (max)
8 outputs per module 4 outputs per group
Isolation
Voltage:
1500 VAC RMS for 60 sec.
Response
Time:
ON to OFF, 8.3 msec.(max) OFF to ON, 1 msec. (max)
Surge Withstand Capability:
Per IEEE 472-1974 and ANSI C37.90A (2500V decaying in 6 microsec at 1.5 mHz)
Physical Characteristics Environment: Temperature Humidity Shock Vibration EMI RFI
0 to 60°C (ambient) 0 to 95% (non-condensing) 10 G for 11 msec. .625 G, 50-500 Hz Per MIL-STD 4616 Per FCC Class A
Dimensions:
1.62 in. (41.8 mm) X 6.00 in. (152.4 mm) X 11.00 in. (279.4 mm)
Weight:
2.0 Ibs. (.91 kg)
CAUTION During the power-up sequence, AC output modules loads for one half cycle. The loads most susceptible and latching circuits.
may cause the false triggering of certain are latching relays, fast-acting solenoids,
Special circuit designs have been incorporated to minimize this false triggering. However, applications using fast reacting or latching devices that initiate mechanical action may be a hazard.
+
GOULD Electronics
Page 83
PI-B355001
B355001
The Gould B355001
J
Input Module consists of eight independent
I220
Rev B
VAC Input Module DATA SHEET and isolated
220 VAC input circuits.
FEATURES Eight independent Circuit isolation
Field side status Transient
220 VAC inputs of 1500 VAC indicators protection
Surge withstand capability pliance with IEEE 472-1974 C37.90A in comand ANSI
Optional Fanning Strip permits module removal without disturbance to field wiring UL listed and CSA certified Designed for harsh plant floor environments
GENERAL d
DESCRIPTION
The Gould B355-001, 220 VAC Input Module senses and converts switched input signals into logic voltage levels used by the Micro 84’” Controller. The module allows for up to eight independently sensed inputs. Eight independent threshold switches sense inputs from an external power source. Inputs can be received from push buttons, limit and proximity switches, temperature and pressure switches, as well as other 220V sources. Each input is electrically isolated by an optical coupler. A neon lamp connected to the circuit’s field side displays the ON/OFF status of the input. The lamp indicates the input’s true state. Both IEEE and ANSI standards for surge withstand capability (SWC) tests are fully satisfied. The module is designed to withstand the severe voltage transients prevalent in industrial environments.
-i
GOULD Electronics
Page 84
AC
.._ NEUTRAL
B355 220 VAC Input Module Terminal Numbering and Connections
B355 220 VAC Input Module Simplified Schematic SPECIFICATIONS
Electrical
Characteristics
ON Level:
180 to 260V rms (less than 1000 ohms source impedance)
OFF Level:
Input Wetting Current: Source
Resistance:
Threshold
Voltage:
Circuit
Characteristics
Topology:
8 inputs
Isolation Voltage:
1500 VAC RMS for 60 set
Response
Time:
ON to OFF, 26 ms (max) OFF to ON, 14 ms (max)
Visual Indicators:
One neon lamp per input ON when input is ON
0 to 9OV rms (less than 1000 ohms source impedance) 0-260V rms (greater than 80K ohms source impedance)
Surge Withstand Capability:
5 mA (typical) @ 180 to 260V rms input
Physical
1000 ohm (max)
Environment:
125V rms (approx.)
Max Input Voltage:
260V rms continuous 300V rms 10 sec. 400V rms 1 cycle
Frequency:
47 to 63 Hz per module
Per IEEE 472-1974 and ANSI C37.90A (2500V decaying in 6 microsec)
Characteristics
Temperature Humidity Shock Vibration EMI RFI
0 to 60°C (ambient) 0 to 95% (non-condensing) 10 G for 11 msec .625 G, 50-500 Hz Per MIL-STD 461 B Per FCC Class A
Dimensions:
1.5 in. (42 mm) X 6.00 in. (152 mm) X 11.00 in. (279 mm)
Weight:
2.0 Ibs. (.91 kg)
NOTES The B355-001 Input Module is compatible with the B354-001 Output Module without the use of additional components. If a direct connection exists, a 50 mA loading resistor is required to guarantee the output module’s 50 mA minimum load current.
-i
GOULD
Page 85
PI-B356-001
Rev B
B356-001 I 24 VDC Output Module (True High) DATA SHEET ’
The Gould 8356-001, Micro 84’” Controller
24 VDC Output Module into eight, independent
FEATURES Eight independent Circuit isolation
Field side status Transient
(True High) converts 24 VDC outputs.
logic signals used within the
24 VDC outputs of 1500 VAC indicators protection
Surge withstand capability pliance with IEEE 472-1974 C37.90A in comand ANSI
Optional Fanning Strip permits module removal without disturbing field wiring High 2 Amp current per output
Designed for harsh plant floor environments
GENERAL
J
DESCRIPTION
The Gould B356-001, 24 VDC Output Module converts logic signals used within the Micro 84 Programmable Controller into eight independent 24 VDC outputs. Logic format for the module is “true high”. Each output is capable of driving relays, pilot lamps, motor starters, solenoids, or other loads up to 2.0 Amperes. The module uses eight transistor switches to control loads connected to an external power source. These switches are designed to withstand the high surge currents typical of industrial loads. Each output is electrically isolated from the controller by an optical coupler. This enables the module and controller to withstand the severe voltage transients prevalent in an industrial environment. Both IEEE and ANSI standards for surge withstand capability (SWC) tests are fully satisfied.
r,
The output circuits are divided into two groups of four outputs each. Each group is driven by a separate voltage source. An
LED indicator connected to each circuit’s field side displays the ON/OFF status of the output. The LED indicates the output’s true state. The module is housed in a light weight, durable LEXAN case. A structural “chimney” within the module provides flowthrough convection cooling and protection from moisture build-up. Self-contained mounting brackets eliminate the need for special I/O housings. A termination connector is shipped with the Micro 84 mainframe to be used when the module is attached to the extreme right bus location. User connections are made to a standard screw terminal strip. This strip is compatible with an optional Fanning Strip (P/N 0212-012) which allows quick module replacement without disturbing field wiring. Data bus connections are made with standard interface connectors. These connectors allow the B356 Output Module to be placed in any location in the l/O structure without interfering with other module operations.
=ii
GOULD Electronics
Page 86
B356-001 OUTPUT MODULE TERMINAL NUMBERING AND CONNECTIONS
8356-001 OUTPUT MODULE SIMPLIFIED SCHEMATIC I
SPECIFICATIONS Electrical Characteristics ON Current 2.OA (max) continuous per output (10.0 A max per module)
Surge Withstand Capability
Per IEEE 472-1974 and ANSI C37.90A (25OOV decaying in 6 ,US)
Surge Current
5 A (max) for 10 ms
Working
Voltage
18 to 30 VDC
Temperature
0 to 60°C (ambient)
Transient
Voltage
50 VDC for 10 ms
Humidity
0 to 95OC (noncondensing)
Shock
10G
Vibration
0.625 G, 50-500 Hz
EMI
Per MILSTD
ON Voltage
Drop
1.2 V at 2 A
OFF Load Current
1 mA (max)
Module Characteristics Topology
8 outputs per module
Environment for 11 ms
461B
Isolation
Voltage
1500 VDC for 10 sec.
RFI
Per FCC Class A
Response
Time
ON to OFF, 1 ms OFF to ON, 1 ms
Dimensions (W x H x D)
1.62 in x 6.00 in x 11.00 in (41.8 mm x 152.4 mm x 279.4 mm)
One LED per input ON when input is ON
Weight
2.0 Ibs (0.91 kg)
Visual
Indicators
(high)
NOTES The B356-001 Output Module of additional components.
is compatible with the B353-001 Input Module without the use
=!i!i GOULD Electronics
Page 87
PI-B357-001
B357-001 I24 r
VDC Input Module (True High) DATA SHEET
The Gould B357-001, 24 VDC Input Module senses and converts 24 VDC switched signals into logic voltage levels used by the Micro 84’” Controller. FEATURES Eight independent Circuit isolation
Field side status Transient
Rev B input
24 VDC inputs of 1500 VAC indicators protection
Surge withstand capability pliance with IEEE 472-1974 C37.90A in comand ANSI
Optional Fanning Strip permits module removal without disturbing field wiring UL listed Designed for harsh plant floor environments
J
GENERAL
DESCRIPTION
The Gould B357-001, 24 VDC Input Module senses and converts switched input signals into logic voltage levels used by the Micro 84 Controller. The logic format for the module is “true high”. Inputs can be received from push buttons, limit and proximity switches, termperature and pressure switches, as well as other 24 VDC sources. Eight independent threshold switches sense inputs from an external power source. Each input is electrically isolated by an optical coupler. An LED indicator connected to the circuit’s field side displays the true ON/OFF state of the input. Both the IEEE and ANSI standards for surge withstand capability (SWC) tests are fully satisfied. This enables the module and controller to withstand severe voltage transients prevalent in industrial environments.
The module is housed in a light weight, durable LEXAN case. A structural “chimney” within the module provides flowthrough convection cooling and protection from moisture build-up. Self-contained mounting brackets eliminate the need for special l/O housings. A termination connector is shipped with the Micro 84 mainframe to be used when the module is attached to the extreme right bus location. User connections are made to a standard screw terminal strip. This strip is compatible with an optional Fanning Strip (P/N 0212-012) which allows quick module replacement without disturbing field wiring. Data bus connections are made with standard interface connectors. These connectors allow the B357 Input Module to be placed in any location in the I/O structure without interfering with other module operation.
=!i!i
GOULD Electronics
Page 88
+V
SOURCE
8357401 INPUT MODULE SIMPLIFIED SCHEMATIC
TERMINAL
6357-001 INPUT MODULE NUMBERING AND CONNECTIONS
SPECIFICATIONS Electrical Characteristics OFF Level Less than 30% of V source ON Level
Greater source
Source
1000 ohm (max) at 10 VDC
Resistance
Threshold
Voltage
30-70% than 70% of V of V source
External
Power
24 VDC at 100 mA
SUPPlY
(max)
Surge Withstand Capability
Per IEEE 472-1974 and ANSI C37.90A (25OOV decaying in 6 ps)
Physical Characteristics Environment
Max Input Voltage
50 VDC, 10 ms
Temperature
0 to 60°C (ambient)
V Source Range
18 to 30 VDC
Humidity
0 to 95% (noncondensing)
8 inputs per module, true high
Shock
IO G for 11 ms
Vibration
0.625 G, 50-500 Hz
EMI
Per MIL-STD
RFI
Per FCC Class A
Dimensions (W x H x D)
1.62 in x 6.00 in. x 11.00 in (41.8 mm x 152.4 mm x 279.4 mm)
Weight
2.0 Ibs (0.91 kg)
Module Characteristics Topology Isolation
Voltage
1500 VDC for 10 sec.
Response
Time
ON to OFF, 12 ms (max) OFF to ON, 12 ms (max)
Visual
Indicators
One LED indicator per input ON when input is ON
4616
(high)
NOTES The 6357-001 Input Module of additional components.
is compatible with the 8356-001
Output
Module
I)
without the use
GOULD Electronics
Page 89
B370-001 BCD Register Output Module DATA SHEET The 8370-001 receives binary data from the Micro 84’” controller and converts it to a BCD output. It applies this output to any TTLICMOS device such as an LED or LCD display.
FEATURES .
Generates
.
Popular true high BCD format two, 3-digit channels
. TTL and CMOS .
12-bit BCD resolution
.
Self-contained
.
Short-circuit proof
.
Continuous on-line diagnostics
.
Removable wiring strip
.
Designed for harsh industrial environments a
UL listed
GENERAL rJ compatible power supply
DESCRIPTION
The B370-001 BCD Register is a dual channel output module for the Micro 84 Controller. It receives data from two output registers in the controller at the end of every scan. It converts the data into a 12.bit binary coded decimal (BCD) signal. This value ranges from 000 to 999. BCD outputs are directly proportional to output register data. Typically the B370 is used in applications to interface timer, counter, sequencer, or other register numerical data with BCD controlled field devices. It is also used with displays on operator control panels. Most TTL or CMOS compatible (latched) BCD displays will directly interface with the B370 without the use of additional components. Similarly, it can drive BCD field devices such as valves, positioners, temperature controllers, monitors, or other BCD transducers. The B370 receives numerical data from output registers 4010, 4012, 4014, and 4016 from both 1K and 2K Micro 84 controllers, and output registers 4018, 4020, 4022, and
4024 in the 2K controller. Since there are two BCD channels per module, the 1K controller supports up to two B370 modules. The 2K controller supports up to four 8370 modules. Similar to the discrete output modules, the first register output module interfaces the first output registers (4010 and 4012), and each successive module interfaces successive output registers. The B370 is organized in a channel strobe architecture: There are 12 data lines and two strobe lines. The data lines are shared by both receiving devices. The strobe lines select which device is to receive data. Both channels are strobed on each scan of the Micro 84. The format of the output data (BCD 1 through BCD 800) is true high (positive). The output data is valid only when the strobe is true low (negative). The B370 BCD Register Output Module easy to install. It is housed in a light-
=> is
GOULD Electronics
Page 90
weight, durable, drip-proof lexan case. It contains mounting brackets which simplify installation. It can be mounted anywhere in the l/O structure. Connectors located on the left- and right-rear sides of the case plug into similar connectors on adjacent modules.
the B370’s front panel. This indicator is a troubleshooting aid. It turns on whenever the internal diagnostic tests detect a failure. These tests continuously exercise random access memory (RAM), read only memory (ROM), and communications circuitry.
This plugging action automatically connects the 8370 to the data bus of the Micro 84 Controller. If the B370 is the right-most module in the l/O structure, plug a termination connector into the connector located on the right-rear side. This termination connector is shipped with the Micro 84 Controller.
The RAM and ROM tests are performed
The B370 does not require a separate power supply. It receives power from the Micro 84. Field wiring is also easy to install. (See the “Terminal Numbering and Output Connections” diagram for wiring your B370 to field devices.) You can use shielded or unshielded wires having a size of 14 to 22 AWG. Just terminate the wires to a removable, 15screw terminal male plug, which is mounted on the front of the B370. This plug is easily removed, which allows you to quickly replace the B370 without disturbing field wiring. Besides the connector with its removable plug, a FAULT indicator is also located on when the 8370 is first powered up and are performed continuously during operation.
Every data and strobe transfer to the field wiring is verified by diagnostic tests for integrity. Potential errors are immediately corrected. For safety, three consecutive diagnostic errors will automatically shut down system scanning (approx. 15 ms.). In addition to the FAULT indicator, the B370 is protected against both over voltages and high current. The B370 is able to withstand the accidental application of 0 to +24 VDC on any data or strobe output. Each output has current limited, short circuit protection. The B370-001 BCD Register Output Module meets the stringent requirements of both IEEE and ANSI standards for radiated surge withstand capability (SWC). The module also withstands the severe voltage transients, electromagnetic interference, and magnetic fields commonly encountered in an industrial environment.
SPECIFICATIONS Electrical Characteristics
Strobe Frequency
Synchronized to Micro 84 scan
TTL & CMOS compatible (2 unit loads) Logic “0“ 0.4 VDC @ 4 mA sink Logic “1” 3.3 VDC @ 1 mA source
Strobe Width
1 ms (typical)
Response Time
<8 ms (both channels)
Data/Strobe Format
0 to 999 counts in BCD Data - true high Strobe - true low
Short Circuit Protection
Oto +24VDC continuous
Throughput Rate
Both channels updated on each scan
Current limit
8 mA (typical)
Topology
Two, 3-digit channels
Module isolation
1500 VRMS/2500 VDC for one minute
Register Format
Nos. 4010, 4012, 4014, 4016, 4018, 4020, 4022, 4024
Output Levels
Circuit Characteristics