Page 231
6−12
General Inverter Electrical Measurements The following table specifies how to measure key system electrical parameters. The diagrams on the next page show inverter-motor systems and the location of measurement points for these parameters. Parameter Supply voltage E1
Supply current I1 Supply power W1 Supply power factor Pf1 Output voltage EO Output current IO Output power WO Output power factor PfO
Circuit location of measurement ER – across L1 and L2 ES – across L2 and L3 ET – across L3 and L1
Ir – L1 Is – L2 It – L3 W11 – across L1 and L2 W12 – across L2 and L3
Pf1
Maintenance
Notes
Reference Value
Fundamental wave effective value
Commercial supply voltage 200V class: 200–240V, 50/60 Hz 400V class: 380–460V, 50/60 Hz, Total effective value Total effective value
W1 u100% 3 u E1 u I1
EU – across U and V Rectifier type Total effective EV – across V and W voltmeter value EW – across W and U IU – U Moving-coil type Total effective IV – V ammeter value IW – W WO1 – across U and V Electronic type Total effective WO2 – across V and W wattmeter value Calculate the output power factor from the output voltage E, output current I, and output power W.
Pf O
Troubleshooting and Maintenance Troubleshooting and
Measuring instrument Moving-coil type voltmeter or rectifier type voltmeter, - - - - - W1 u 100% 3 u EO u I O
Note 1:
Use a meter indicating a fundamental wave effective value for voltage, and meters indicating total effective values for current and power.
Note 2:
The inverter output has a distorted waveform, and low frequencies may cause erroneous readings. However, the measuring instruments and methods listed above provide comparably accurate results.
Note 3:
A general-purpose digital volt meter (DVM) is not usually suitable to measure a distorted waveform (not pure sinusoid).
Page 232
6−13
The figures below show measurement locations for voltage, current, and power measurements listed in the table on the previous page. The voltage to be measured is the fundamental wave effective voltage. The power to be measured is the total effective power. Single-phase Measurement Diagram
Three-phase Measurement Diagram
Troubleshooting and Troubleshooting and MaintenanceMaintenance
Page 233
6−14
Inverter Output Voltage Measurement Techniques
Maintenance
Troubleshooting and Maintenance Troubleshooting and
Taking voltage measurements around drives equipment requires the right equipment and a safe approach. You are working with high voltages and high-frequency switching waveforms that are not pure sinusoids. Digital voltmeters will not usually produce reliable readings for these waveforms. And, it is usually risky to connect high voltage signals to oscilloscopes. The inverter output semiconductors have some leakage, and no-load measurements produce misleading results. So, we highly recommend using the following circuits to measure voltage for performing the equipment inspections.
HIGH VOLTAGE: Be careful not to touch wiring or connector terminals when working with the inverters and taking measurements. Be sure to place the measurement circuitry components above in an insulated housing before using them.
Page 234
6−15
IGBT Test Method The following procedure will check the inverter transistors (IGBTs) and diodes: 1. Disconnect input power to terminals [R, S, and T] and motor terminals [U, V, and W]. 2. Disconnect any wires from terminals [+] and [–] for regenerative braking. 3. Use a Digital Volt Meter (DVM) and set it for 1Ÿ resistance range. You can check the status of the charging state of terminals [R, S, T, U, V, W, +, and –] of the inverter and the probe of the DVM by measuring the charging state.
Table Legend Part D1 D2
D4
DVM Measured Part DVM Measured Part DVM Measured Value Value Value + – + – + – [R] [+1] D5 [S] [–] TR3 [W] [+] #’Ÿ #0Ÿ #’Ÿ [+1] [R] [–] [S] [+] [W] #0Ÿ #’Ÿ #0Ÿ [S] [+1] D6 [T] [–] TR4 [U] [–] #’Ÿ #0Ÿ #0Ÿ [+1] [S] [–] [T] [–] [U] #0Ÿ #’Ÿ #’Ÿ [T] [+1] TR1 [U] [+] TR5 [V] [–] #’Ÿ #’Ÿ #0Ÿ [+1] [T] [+] [U] [–] [V] #0Ÿ #0Ÿ #’Ÿ [R] [–] TR2 [V] [+] TR6 [W] [–] #0Ÿ #’Ÿ #0Ÿ [–] [R] [+] [V] [–] [W] # ’ Ÿ #’Ÿ #0Ÿ
NOTE: The resistance values for the diodes or the transistors will not be exactly the same, but they will be close. If you find a significance difference, a problem may exist. NOTE: Before measuring the voltage between [+] and [–] with the DC current range, confirm that the smoothing capacitor is discharged fully, then execute the tests.
Troubleshooting and Troubleshooting and MaintenanceMaintenance
D3
Almost infinite resistance: # ’ Ÿ Almost zero resistance: # 0 Ÿ
Page 235
6−16
Warranty
Warranty Terms The warranty period under normal installation and handling conditions shall be two (2) years from the date of manufacture, or one (1) year from the date of installation, whichever occurs first. The warranty shall cover the repair or replacement, at Hitachi's sole discretion, of ONLY the inverter that was installed. 1. Service in the following cases, even within the warranty period, shall be charged to the purchaser: a. Malfunction or damage caused by mis-operation or modification or improper repair b. Malfunction or damage caused by a drop after purchase and transportation c. Malfunction or damage caused by fire, earthquake, flood, lightening, abnormal input voltage, contamination, or other natural disasters 2. When service is required for the product at your work site, all expenses associated with field repair shall be charged to the purchaser.
Maintenance
Troubleshooting and Maintenance Troubleshooting and
3. Always keep this manual handy; please do not lose it. Please contact your Hitachi distributor to purchase replacement or additional manuals.
Page 236
Glossary and Bibliography
In This Appendix... Sa C] (0S-5-\- | 6 rere 2 - Bibliography.............0....ccccceeeceeee eee eeeeneeeeeeeeeeeeceeeeeeeeeeesaaeeeeeeeeeeeeae 8
Page 237
A−2
Appendix A
Appendix A
Glossary Ambient Temperature
The air temperature in the chamber containing a powered electronic unit. A unit’s heat sinks rely on a lower ambient temperature in order to dissipate heat away from sensitive electronics.
Arrival Frequency
The arrival frequency refers to the set output frequency of the inverter for the constant speed setting. The arrival frequency feature turns on an output when the inverter reaches the set constant speed. The inverter has various arrival frequencies and pulsed or latched logic options.
Auto-tuning
The ability of a controller to execute a procedure that interacts with a load to determine the proper coefficients to use in the control algorithm. Auto-tuning is a common feature of process controllers with PID loops. Hitachi inverters feature auto tuning to determine motor parameters for optimal commutation. Auto-tuning is available as a special command from a digital operator panel. See also Digital Operator Panel.
Base Frequency
The power input frequency for which an AC induction motor is designed to operate. Most motors will specify a 50 to 60 Hz value. The Hitachi inverters have a programmable base frequency, so you must ensure that parameter matches the attached motor. The term base frequency helps differentiate it from the carrier frequency. See also Carrier Frequency and Frequency Setting.
Braking Resistor
An energy-absorbing resistor that dissipates energy from a decelerating load. Load inertia causes the motor to act as a generator during deceleration. For the L200 inverter models, the braking unit and braking resistor are optional (external) components. See also Four-quadrant Operation and Dynamic Braking.
Break-away Torque
The torque a motor must produce to overcome the static friction of a load, in order to start the load moving.
Carrier Frequency
The frequency of the constant, periodic, switching waveform that the inverter modulates to generate the AC output to the motor. See also PWM.
CE
A regulatory agency for governing the performance of electronic products in Europe. Drive installations designed to have CE approval must have particular filter(s) installed in the application.
Choke
An inductor that is tuned to react at radio frequencies is called a “choke,” since it attenuates (chokes) frequencies above a particular threshold. Tuning is often accomplished by using a movable magnetic core. In variable-frequency drive systems, a choke positioned around high-current wiring can help attenuate harmful harmonics and protect equipment. See also Harmonics.
Page 238
A−3
The inverter DC braking feature stops the AC commutation to the motor, and sends a DC current through the motor windings in order to stop the motor. Also called “DC injection braking,” it has little effect at high speed, and is used as the motor is nearing a stop.
Deadband
In a control system, the range of input change for which there is no perceptible change in the output. In PID loops, the error term may have a dead band associated with it. Deadband may or may not be desirable; it depends on the needs of the application.
Digital Operator Panel
For Hitachi inverters, “digital operator panel” (DOP) refers first to the operator keypad on the front panel of the inverter. It also includes hand-held remote keypads, which connect to the inverter via a cable. Finally, the DOP Professional is a PC-based software simulation of the keypad devices.
Diode
A semiconductor device that has a voltage-current characteristic that allows current to flow only in one direction, with negligible leakage current in the reverse direction. See also Rectifier.
Duty Cycle
1. The percent of time a square wave of fixed frequency is ON (high) versus OFF (low). 2. The ratio of operating time of a device such as a motor to its resting time. This parameter usually is specified in association with the allowable thermal rise for the device.
Dynamic Braking
For the L200 inverter models, the braking unit and braking resistor are optional (external) components. The dynamic braking feature shunts the motor-generated EMF energy into a special braking resistor. The added dissipation (braking torque) is effective at higher speeds, having a reduced effect as the motor nears a stop.
Error
In process control, the error is the difference between the desired value or setpoint (SP) and the actual value of a the process variable (PV). See also Process Variable and PID Loop.
EMI
Electromagnetic Interference - In motor/drive systems, the switching of high currents and voltages creates the possibility of generating radiated electrical noise that may interfere with the operation of nearby sensitive electrical instruments or devices. Certain aspects of an installation, such as long motor lead wire lengths, tend to increase the chance of EMI. Hitachi provides accessory filter components you can install to decrease the level of EMI.
Four-quadrant operation
Referring to a graph of torque versus direction, a four-quadrant drive can turn the motor either forward or reverse, as well as decelerate in either direction (see also reverse torque). A load that has a relatively high inertia and must move in both directions and change directions rapidly requires four-quadrant capability from its drive.
Appendix A A Appendix
DC Braking
Page 239
Appendix A
Appendix A
A−4
Free-run Stop
A method of stopping a motor, caused when the inverter simply turns OFF its motor output connections. This may allow the motor and load to coast to a stop, or a mechanical brake may intervene and shorten the deceleration time.
Frequency Setting
While frequency has a broad meaning in electronics, it typically refers to motor speed for variable-frequency drives (inverters). This is because the output frequency of the inverter is variable, and is proportional to the attained motor speed. For example, a motor with a base frequency of 60 Hz can be speed controlled with an inverter output varying form 0 to 60 Hz. See also Base Frequency, Carrier Frequency, and Slip.
Harmonics
A harmonic is a whole number multiple of a base of fundamental frequency. The square waves used in inverters produce high frequency harmonics, even though the main goal is to produce lowerfrequency sine waves. These harmonics can be harmful to electronics (including motor windings) and cause radiated energy that interferes with nearby electronic devices. Chokes, line reactors, and filters are sometimes used to suppress the transmission of harmonics in an electrical system. See also Choke.
Horsepower
A unit of physical measure to quantify the amount of work done per unit of time. You can directly convert between horsepower and Watts as measurements of power.
IGBT
Insulated Gate Bipolar Transistor(IGBT) – A semiconductor transistor capable of conducting very large currents when in saturation and capable of withstanding very high voltages when it is OFF. This high-power bipolar transistor is the type used in Hitachi inverters.
Inertia
The natural resistance a stationary object to being moved by an external force. See also Momentum.
Intelligent Terminal
A configurable input or output logic function on the Hitachi inverters. Each terminal may be assigned one of several functions.
Inverter
A device that electronically changes DC to AC current through an alternating process of switching the input to the output, inverted and non-inverted. A variable speed drive such as the Hitachi L200 is also called an inverter, since it contains three inverter circuits to generate 3-phase output to the motor.
Isolation Transformer
A transformer with 1:1 voltage ratio that provides electrical isolation between its primary and secondary windings. These are typically used on the power input side of the device to be protected. An isolation transformer can protect equipment from a ground fault or other malfunction of nearby equipment, as well as attenuate harmful harmonics and transients on the input power.
Page 240
A−5
Usually done manually, a jog command from an operator’s panel requests the motor/drive system to run indefinitely in a particular direction, until the machine operator ends the jog operation.
Jump Frequency
A jump frequency is a point on the inverter output frequency range that you want the inverter to skip around. This feature may be used to avoid a resonant frequency, and you can program up to three jump frequencies in the inverter.
Line Reactor
A three-phase inductor generally installed in the AC input circuit of an inverter to minimize harmonics and to limit short-circuit current.
Momentum
The physical property of a body in motion that causes it to remain in motion. In the case of motors, the rotor and attached load are rotating and possesses angular momentum.
Multi-speed Operation
The ability of a motor drive to store preset discrete speed levels for the motor, and control motor speed according to the currently selected speed preset. The Hitachi inverters have 16 preset speeds.
Motor Load
In motor terminology, motor load consists of the inertia of the physical mass that is moved by the motor and the related friction from guiding mechanisms. See also Inertia.
NEC
The National Electric Code is a regulatory document that governs electrical power and device wiring and installation in the United States.
NEMA
The National Electric Manufacturer’s Association. NEMA Codes are a published series of device ratings standards. Industry uses these to evaluate or compare the performance of devices made by various manufacturers to a known standard.
Open-collector Outputs
A common logic-type discrete output that uses an NPN transistor that acts as a switch to a power supply common, usually ground. The transistor’s collector is open for external connection (not connected internally). Thus, the output sinks external load current to ground.
Power Factor
A ratio that expresses a phase difference (timing offset) between current and voltage supplied by a power source to a load. A perfect power factor = 1.0 (no phase offset). Power factors less than one cause some energy loss in power transmission wiring (source to load).
PID Loop
Proportional - Integral-Derivative - A mathematical model used for process control. A process controller maintains a process variable (PV) at a setpoint (SP) by using its PID algorithm to compensate for dynamic conditions and vary its output to drive the PV toward the desired value. For variable-frequency drives, the process variable is the motor speed. See also Error.