Manual · Hitachi
X200 Series Inverter Instruction Manual
Manual305 pagesPDF 8.9 MB
Instruction manual for the Hitachi X200 Series inverter (single-phase 200V and three-phase 200V and 400V class): install, set up, run.
Covers · 1 model
The models it covers
Summary
What is in it
The Hitachi X200 Series Inverter Instruction Manual (NT301XC, Sep 2007) covers the single-phase 200V class and three-phase 200V and 400V class models. It gives the safety warnings and fuse sizes, the inverter specifications, mounting, wiring and the powerup test, keypad use, the drive parameter groups, intelligent input and output terminals, analog I/O, PID loop operation, accessories such as dynamic braking, and troubleshooting, trip history and maintenance.
Its parts
- Safety Messages
- Chapter 1: Getting Started
- Chapter 2: Inverter Mounting and Installation
- Chapter 3: Configuring Drive Parameters
- Chapter 4: Operations and Monitoring
- Chapter 5: Inverter System Accessories
- Chapter 6: Troubleshooting and Maintenance
From the manual
Key facts from this manual
Each line names its page in the PDF.
Instruction manual for the Hitachi X200 series inverters, 200V and 400V class models for motors from 1/4 to 10 horsepower. It covers specifications, installation, parameter setup, the intelligent terminals, system accessories, troubleshooting, Modbus network communication and CE-EMC installation.
- Device
- Inverter drive for motors from 1/4 to 10 horsepower, 240VAC or 480VAC input p. 23
- Input power
- 200V to 240V (SFEF 1-phase only, NFU 1- or 3-phase, LFU 3-phase only); 400V class 3-phase 380V to 480V p. 28, 29
- Model code
- S single-phase 200V, L three-phase 200V, N single/three-phase 200V, H three-phase 400V; E Europe, U USA, R Japan; F with EMC filter p. 25
- Overload capacity
- 150% rated current for 1 minute p. 31
- Starting torque
- 100% at 6Hz p. 23
- Carrier frequency
- 2kHz to 12kHz, default 3kHz p. 31
- Accel/decel time
- 0.01 to 3000 seconds, linear or S-curve, second setting available p. 31
- Speed reference
- 0 to 10 VDC (10k Ohms), 4 to 20mA (250 Ohms) or a 1k to 2k Ohm, 2W potentiometer p. 31
- Alarm contact
- 1c contacts, normally open or closed p. 31
- Network
- Built-in RS-485 Modbus RTU, 4800/9600/19200 bps, addresses 1 to 32, RJ45 connector p. 245, 246
- Fault codes
- E 01 and E 02 over-current, E 07 over-voltage, E 08 EEPROM error, E 09 under-voltage, E 11 CPU error, E 12 external trip, E 14 ground fault, E 21 inverter thermal trip, E 35 thermistor, E 60 communications error p. 224, 225
- Remote keypad
- OPE-SRmini keypad with ICS-1 (1m) or ICS-3 (3m) cable; 4X-KITmini for NEMA4X p. 24
- Copy unit
- SRW-0EX digital operator/copy unit with 2-line display; copies settings between X200 inverters p. 24
- Environment
- -10 to 40°C operating, -25 to 70°C storage, 20 to 90% humidity non-condensing p. 31
What this manual walks you through
- Specifications of the 200V and 400V class models p. 26, 28, 29
- Reading the specification label and model number p. 25
- Remote keypad and copy unit options p. 24
- Choosing optional reactors, filters and braking parts p. 213
- Troubleshooting a motor that will not run, runs the wrong way or misses its speed p. 222, 223
- Error codes and clearing a fault p. 224, 225
- Reviewing trip history and conditions at the trip p. 226
- Connecting the inverter to a Modbus network p. 245, 246
Good to know
- Never switch power off while the copy unit is copying, or the inverter may not work at the next power-up. p. 24
- Settings can be copied only between X200 series inverters. p. 24
- Switching power off while the [RS] reset input is ON causes an EEPROM error when power returns. p. 225
- Edits are stored at power down, so wait at least six seconds after editing before turning power off. p. 223
- Ground fault detection protects the inverter, not people. p. 225
Questions this manual answers
How do I clear a fault on a Hitachi X200?
Press the Stop/Reset key. Setting B084=00 clears the trip history but keeps the inverter settings. p. 224
How do I see the last three X200 faults?
Use monitor functions D081, D082 and D083; D081 is the most recent and D083 the oldest. p. 226
What cable connects a remote keypad to the X200?
Part ICS-1 (1m) or ICS-3 (3m) connects the modular connectors of the keypad and the inverter. p. 24
How many X200 inverters can share one Modbus network?
Each inverter needs a unique address from 1 to 32, at 4800, 9600 or 19200 bps. p. 245
Why won't my X200 motor run?
Check the frequency source A001 and run command source A002, power at [L1], [L2] and [L3/N], any error code, and that F001 is above zero. p. 222
The whole text · 31 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
- Pages 1 to 101-10
- Pages 11 to 2011-20
- Pages 21 to 3021-30
- Pages 31 to 4031-40
- Pages 41 to 5041-50
- Pages 51 to 6051-60
- Pages 61 to 7061-70
- Pages 71 to 8071-80
- Pages 81 to 9081-90
- Pages 91 to 10091-100
- Pages 101 to 110101-110
- Pages 111 to 120111-120
- Pages 121 to 130121-130
- Pages 131 to 140131-140
- Pages 141 to 150141-150
- Pages 151 to 160151-160
- Pages 161 to 170161-170
- Pages 171 to 180171-180
- Pages 181 to 190181-190
- Pages 191 to 200191-200
- Pages 201 to 210201-210
- Pages 211 to 220211-220
- Pages 221 to 230221-230
- Pages 231 to 240231-240
- Pages 241 to 250241-250
- Pages 251 to 260251-260
- Pages 261 to 270261-270
- Pages 271 to 280271-280
- Pages 281 to 290281-290
- Pages 291 to 300291-300
- Pages 301 to 305301-305
The file