Spec sheet · Hitachi
Variable Frequency Drive X200 Series
Spec sheet20 pagesPDF 969 KB
Product brochure for the Hitachi X200 Series compact variable frequency drives (inverters): features, specifications, wiring.
Covers · 1 model
The models it covers
Summary
What is in it
Hitachi brochure for the X200 Series compact variable frequency drives (inverters) in 1-/3-phase 200 V and 3-phase 400 V classes, US, European and Japanese versions. It describes features such as trip avoidance, energy saving, the integrated EMC filter and emergency stop, then gives the model configuration, standard specifications, dimensions, operation and programming, terminal functions, the function list, protective functions, connecting diagrams, wiring and accessories, torque and derating curves and notes for correct operation.
Its parts
- Features
- Standard Specifications
- Dimensions
- Operation and Programming
- Operation / Terminal Functions
- Function List
- Protective Functions
- Connecting Diagram
- Wiring and Accessories
- Torque characteristics/Derating Curves
- For Correct Operation
From the sheet
Key facts from this sheet
Each line names its page in the PDF.
Brochure and specification sheet for the Hitachi X200 series variable frequency drives, from 0.2 kW to 7.5 kW, in 200V and 400V classes with US, European and Japanese versions. It lists the models, general specifications, dimensions, keypad operation, terminal functions, protective functions, wire sizes and optional accessories.
- Device
- Compact variable frequency drive (inverter) p. 2
- Motor size
- 0.2 kW (1/4 HP) to 7.5 kW (10 HP) p. 3
- Power source
- S: 1-phase 200V; N: 1- or 3-phase 200V; L: 3-phase 200V; H: 3-phase 400V p. 3
- Versions
- U: US, E: European, R: Japanese p. 3
- Control
- Sine wave PWM, V/f control (constant or reduced torque) p. 4
- Accel/decel time
- 0.01 to 3000 sec., linear or sigmoid, two-stage p. 4
- Logic inputs
- Five programmable input terminals (1 to 5) p. 7
- Outputs
- One open collector output, 27V DC 50mA max; one 1c relay (AL0, AL1, AL2), 250V AC/30V DC 2.5A p. 4
- Analog inputs
- 0 to 10V DC (10kohm input impedance) or 4 to 20mA DC (250ohm) p. 7
- Analog output
- 0 to 10V DC, 10-bit, frequency or current monitor p. 3, 4
- Network
- RS-485 Modbus-RTU built in p. 3
- Keypad
- 4-digit 7-segment LEDs; potentiometer, RUN, STOP/RESET, UP, DOWN, FUN and STR keys p. 4
- Ambient
- -10 to 50°C, carrier derating above 40°C, no freezing; 20 to 90% RH p. 4
- Accessories
- SRW-0EX remote operator with copy function; ICS-1, 3 communication cables; OPE-SRmini keypad; 4X-KITmini NEMA 4X kit p. 4, 6, 7
What this sheet walks you through
- Choosing a model by motor size and regional version p. 2
- Standard and general specifications p. 4
- Mounting dimensions of each frame size p. 5
- Setting the maximum frequency, running by potentiometer and monitoring current from the keypad p. 6
- Setting the RS-485 and emergency stop switches SW7 and SW8 p. 7
- Power and control terminal functions and ratings p. 7
- Protective functions and reading the details of a fault p. 11
- Wire sizes and fuses for each model p. 14
- What the optional reactors, filters and braking parts do p. 14
Good to know
- Turning SW8 on changes the logic input terminal assignments automatically. p. 7
- Only terminal 5 can take the PTC thermistor function. p. 4
- A ground fault error (E14) cannot be cleared by reset; switch off power and check the wiring. p. 11
- Side-by-side mounting needs derating of carrier frequency and output current. p. 3
- Use larger power wire if the run is longer than 20m (66ft). p. 14
Questions this sheet answers
What does the N, S, L or H in an X200 model number mean?
It is the power source: N is 1- or 3-phase 200V, S is 1-phase 200V, L is 3-phase 200V and H is 3-phase 400V. p. 3
Does the Hitachi X200 support Modbus?
Yes. RS-485 Modbus-RTU is standard, and switch SW7 selects the RS-485 port or the keypad. p. 3, 7
Which X200 terminal takes a PTC motor thermistor?
Only terminal 5 can be assigned the PTC thermistor function. p. 4
Is there a remote keypad for the X200?
The options list a remote operator with copy function (SRW-0EX) and communication cables (ICS-1, 3). p. 4
What ambient temperature can the X200 run in?
-10 to 50°C without freezing, with carrier derating above 40°C. p. 4