The text of a manual · part 3 of 31
X200 Series Inverter Instruction Manual, pages 21 to 30
Pages 21 to 30 of 305
The original document is the PDF (8.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Hitachi X200 Series
Page 21
Page 22
1−1
In This Chapter…
GettingGetting started started
Getting Started
1 page
-
Introduction...................................................................................... 2
-
X200 Inverter Specifications ........................................................... 5
-
Introduction to Variable-Frequency Drives.................................. 19
-
Frequently Asked Questions ........................................................ 24
Page 23
1−2
Getting started
Getting started
Introduction Main Features Congratulation on your purchase of an X200 Series Hitachi inverter! This inverter drive features state-of-the-art circuitry and components to provide high performance. The housing footprint is exceptionally small, given the size of the corresponding motor. The Hitachi X200 product line includes more than a dozen inverter models to cover motor sizes from 1/4 horsepower to 10 horsepower, in either 240VAC or 480VAC power input versions. The main features are: x 200V and 400V class inverters
X200-004LFU
X200-037LFU x US or EU versions available (country-specific input voltage range and default values) x Built-in RS485 MODBUS RTU as standard x New current suppressing function x Sixteen programmable speed levels x PID control adjusts motor speed automatically to maintain a process variable value x Integrated CE filter for SFE and HFE versions The design in Hitachi inverters overcomes many of the traditional trade-offs between speed, torque and efficiency. The performance characteristics are: x High starting torque of 100% at 6Hz x Continuous operation at 100% torque within a 1:10 speed range (6/60Hz / 5/50Hz) without motor derating. x Fan has ON/OFF selection to provide longer life for cooling fan. A full line of accessories from Hitachi is available to complete your motor application: x Digital remote operator keypad x Panel-mount keypad bezel kit and DIN rail mounting adapter (35mm rail size) x Dynamic braking unit with resistors x Radio noise filters
Page 24
1−3
Operator Interface Options
Hitachi offers a panel mount keypad kit for the OPE-SRmini (below, right). It includes the mounting flange, gasket, keypad, and other hardware. You can mount the keypad with the potentiometer for a NEMA1 rating. The kit also provides for removing the potentiometer knob to meet NEMA4X requirements, as shown (part no. 4X-KITmini).
Digital Operator Copy Unit – The optional digital operator / copy unit (part no.SRW-0EX) is shown to the right. It has a 2-line display that shows parameters by function code and by name. It has the additional capability of reading (uploading) the parameter settings in the inverter into its memory. Then you can connect the copy unit on another inverter and write (download) the parameter settings into that inverter. OEMs will find this unit particularly useful, as one can use a single copy unit to transfer parameter settings from one inverter to many. NOTE: Copy is possible between X200 series. It is not possible to copy between X200 series and other models. Other digital operator interfaces may be available from your Hitachi distributor for particular industries or international markets. Contact your Hitachi distributor for further details. NOTE: Never turn power OFF while copying (display “Copy CMD!!”). Otherwise the inverter may lose functionality at next power ON.
GettingGetting started started
The X200 inverter can utilize a remote keypads, such as the OPE-SRmini (right) or SRW-0EX (below). This allows the keypad to operate the inverter remotely, as shown (below, left). A cable (part no. ICS-1 or ICS-3, 1m or 3m) connects the modular connectors of the keypad and inverter.
Page 25
1−4
Getting started
Getting started
Inverter Specification Label The Hitachi X200 inverters have product labels located on the right side of the housing, as pictured below. Be sure to verify that the specifications on the labels match your power source, and application safety requirements.
Specifications label Regulatory agency approval labels (opposite side)
Inverter model number Motor capacity for this model Power Input Rating: Frequency, voltage, current Output Rating: Frequency, voltage, current Manufacturing codes: Lot number, date, etc.
Inverter Specification Label The model number for a specific inverter contains useful information about its operating characteristics. Refer to the model number legend below: X200
007
S
F
E
F Integrated Filter F= With EMC filter No mark = No integrated filter
Series name
Restricted distribution E=Europe, U=USA, R=Japan Configuration type F=with keypad Input voltage: S=Single-phase 200V class L=Three-phase 200V class N=Single/Three-phase 200V class H=Three-phase 400V class Applicable motor capacity in kW 002=0.2kW 022=2.2kW 004=0.4kW 030=3.0kW 005=0.55kW 037=3.7kW 007=0.75kW 040=4.0kW 011=1.1kW 055=5.5kW 015=1.5kW 075=7.5kW
Page 26
1−5
X200 Inverter Specifications The following tables are specific to X200 inverters for the 200V and 400V class model groups. Note that “General Specifications” on page 1-10 apply to both voltage class groups. Footnotes for all specification tables follow the table below. Item X200 inverters, EU version 200V models USA version Applicable motor size *2
200V class Specifications 002SFEF 004SFEF 005SFEF 007SFEF 011SFEF 002NFU 004NFU – 007NFU – kW 0.2 0.4 0.55 0.75 0.11 HP 1/4 1/2 3/4 1 1.5 Rated capacity 230V 0.5 1.0 1.1 1.5 1.9 (kVA) 240V 0.5 1.0 1.2 1.6 2.0 Rated input voltage - SFEF type: 1-phase input only - NFU type: 1-phase or 3-phase input 1-phase: 200V-15% to 240V +10%, 50/60Hz r5% 3-phase: 200V-15% to 240V r10%, 50/60Hz r5% Integrated EMC EU version SFEF series : EN61800-3 category C1 filter filter USA version – Rated input EU version 3.1 5.8 6.7 9.0 11.2 current (A) USA version 1.8 3.4 5.2 Rated output voltage *3 3-phase: 200 to 240V (proportional to input voltage) Rated output current (A) 1.4 2.6 3.0 4.0 5.0 Efficiency at 100% rated output 89.0% 92.3% 93.2% 94.1% 94.7% 18 24 26 33 42 Watt loss (fc=3kHz) at 70% output Approximate (W) at 100% output 22 31 34 44 58 Starting torque *7 100% at 6Hz Braking Dynamic braking, 100%: d 50Hz approx. % torque 50%: d 60Hz (short time stop Capacitive feedback type, dynamic braking unit and from 50/60Hz) *8 braking resistor optional, individually installed DC braking Variable operating frequency, time, and braking force Weight EU version Kg 0.8 1.0 1.5 1.5 2.4 (-SFEF) lb 1.77 2.21 3.31 3.31 5.30 USA version Kg 0.8 0.9 – 1.5 – (-NFU) lb 1.77 1.99 – 3.31 –
GettingGetting started started
Model-specific tables for 200V and 400V class inverters
Page 27
1−6
Getting started
Getting started
Footnotes for the preceding table and the tables that follow: Note1:
The protection method conforms to JEM 1030.
Note2:
The applicable motor refers to Hitachi standard 3-phase motor (4p). When using other motors, care must be taken to prevent the rated motor current (50/60Hz) from exceeding the rated output current of the inverter.
Note3:
The output voltage decreases as the main supply voltage decreases (except when using the AVR function). In any case, the output voltage cannot exceed the input power supply voltage.
Note4:
To operate the motor beyond 50/60Hz, consult the motor manufacturer for the maximum allowable rotation speed.
Note5:
EU version inverters (-SFE and -HFE) have integrated EMC filter.
Note6:
For achieving approved input voltage rating categories: x 460 to 480VAC – Over-voltage category 2 x 380 to 460VAC – Over-voltage category 3 To meet the Over-voltage category 3, insert an EN or IEC standard compliant isolation transformer that is earth grounded and star connected (for Low Voltage Directive).
Note7:
At the rated voltage when using a Hitachi standard 3-phase, 4-pole motor.
Note8:
The braking torque via capacitive feedback is the average deceleration torque at the shortest deceleration (stopping from 50/60Hz as indicated). It is not continuous regenerative braking torque. The average deceleration torque varies with motor loss. This value decreases when operating beyond 50Hz. If a large regenerative torque is required, the optional regenerative braking unit and a resistor should be used.
Note9:
The frequency command is the maximum frequency at 9.8V for input voltage 0 to 10VDC, or at 19.6mA for input current 4 to 20mA. If this characteristic is not satisfactory for your application, contact your Hitachi representative.
Note10:
If the inverter is operated outside the region shown in the graph in the derating curve, the inverter may be damaged or its service life may be shortened. Set B083 Carrier Frequency Adjustment in accordance with the expected output current level. See derating curve section for the detailed information of the inverter operating range.
Note11:
The storage temperature refers to the short-term temperature during transportation.
Note12:
Conforms to the test method specified in JIS C0040 (1999). For the model types excluded in the standard specifications, contact your Hitachi sales representative.
Page 28
1−7
X200 Inverter Specifications, continued… 200V class Specifications 015SFEF 022SFEF – – – 015NFU 022NFU 037LFU 055LFU 075LFU kW 1.5 2.2 3.7 5.5 7.5 HP 2 3 5 7.5 10 Rated capacity 230V 2.8 3.9 6.3 9.5 12.7 (kVA) 240V 2.9 4.1 6.6 9.9 13.3 Rated input voltage - SFEF type: 1-phase input only - NFU type: 1-phase or 3-phase input - LFU type: 3-phase input only 1-phase: 200V-15% to 240V +10%, 50/60Hz r5% 3-phase: 200V-15% to 240V r10%, 50/60Hz r5% Integrated EMC EU version SFE series : EN61800-3 category C1 filter filter USA version – Rated input EU version 16.0 22.5 – – – current (A) USA version 9.3 13.0 20.0 30.0 40.0 Rated output voltage *3 3-phase: 200 to 240V (proportional to input voltage) Rated output current (A) 7.1 10.0 15.9 24 32 Efficiency at 100% rated output 94.5% 96.0% 96.4% 96.1% 96.1% 58 61 91 138 186 Watt loss (fc=3kHz) at 70% output Approximate (W) at 100% output 83 87 133 215 295 Starting torque *7 100% at 6Hz Braking Dynamic braking, 50%: d 60Hz 20%: d 60Hz approx. % torque Capacitive feedback type, dynamic braking unit and (short time stop braking resistor optional, individually installed from 50/60Hz) *8 DC braking Variable operating frequency, time, and braking force Weight EU version Kg 2.4 2.5 – – – (-SFEF) lb 5.30 5.52 – – – 2.3 2.4 2.3 4.2 4.2 USA version Kg (-N/LFU) lb 5.08 5.30 5.08 9.27 9.27
GettingGetting started started
Item X200 inverters, EU version 200V models USA version Applicable motor size *2
Page 29
Getting started
Getting started
1−8
Item X200 inverters, EU version 400V models USA version Applicable motor size *2
400V class Specifications 004HFEF 007HFEF 015HFEF 022HFEF 004HFU 007HFU 015HFU 022HFU kW 0.4 0.75 1.5 2.2 HP 1/2 1 2 3 Rated capacity 380V 0.9 1.6 2.5 3.6 (kVA) 480V 1.2 2.0 3.1 4.5 Rated input voltage *6 3-phase: 380V-15% to 480V r10%, 50/60Hz r5% Integrated EMC EU version SFE series : EN61800-3 category C2 filter filter USA version – Rated input current (A) 2.0 3.3 5.0 7.0 Rated output voltage *3 3-phase: 380 to 480V (proportional to input voltage) Rated output current (A) 1.5 2.5 3.8 5.5 Efficiency at 100% rated output 93.8% 94.9% 96.4% 96.9% 20 29 40 49 Watt loss (fc=3kHz) at 70% output Approximate (W) at 100% output 25 38 54 68 Starting torque *7 100% at 6Hz Braking Dynamic braking, 50%: d 60Hz 20%: d 60Hz approx. % torque Capacitive feedback type, dynamic braking unit and braking (short time stop resistor optional, individually installed from 50/60Hz) *8 DC braking Variable operating frequency, time, and braking force Weight EU version Kg 1.5 2.3 2.4 2.4 (-HFEF) lb 3.31 5.08 5.30 5.30 USA version Kg 1.4 2.2 2.3 2.3 (-HFU) lb 3.09 4.86 5.08 5.08
Page 30
1−9
400V class Specifications 030HFEF 040HFEF 055HFEF 075HFEF – 040HFU 055HFU 075HFU kW 3.0 4.0 5.5 7.5 HP 4 5 7.5 10 Rated capacity 380V 5.1 5.6 8.5 10.5 (kVA) 480V 6.4 7.1 10.8 13.3 Rated input voltage *6 3-phase: 380V-15% to 480V r10%, 50/60Hz r5% Integrated EMC EU version SFE series : EN61800-3 category C2 filter filter USA version – Rated input current (A) 10.0 11.0 16.5 20.0 Rated output voltage *3 3-phase: 380 to 480V (proportional to input voltage) Rated output current (A) 7.8 8.6 13 16 Efficiency at 100% rated output 96.8% 97.3% 97.3% 98.3% 68 74 101 127 Watt loss (fc=3kHz) at 70% output Approximate (W) at 100% output 96 107 150 189 Starting torque *7 100% at 6Hz Braking Dynamic braking, 20%: d 60Hz approx. % torque Capacitive feedback type, dynamic braking unit and braking (short time stop resistor optional, individually installed from 50/60Hz) *8 DC braking Variable operating frequency, time, and braking force Weight EU version Kg 2.4 2.4 4.2 4.2 (-HFEF) lb 5.30 5.30 9.27 9.27 USA version Kg – 2.3 4.2 4.2 (-HFU) lb – 5.08 9.27 9.27
Torque characteristics Base frequency = 60Hz
Base frequency = 50Hz
Short time performance
150 130
Short time performance
150 0.2~4kW
0.2~4kW
130
Output torque (%)
Output torque (%)
5.5, 7.5kW 100 95 80 0.2~4kW 55 45 35
0
5.5, 7.5kW
Continuous performance
16
20
60
Output frequency (Hz)
5.5, 7.5kW
100 90 75 0.2~4kW 55 45 35
5.5, 7.5kW
Continuous performance 120
0
15
16.7
50
120
Output frequency (Hz)
NOTE: The data are based on the Hitachi standard induction motor (4p). The torque performance depends on the characteristics of the motor to be used.
GettingGetting started started
Item X200 inverters, EU version 400V models USA version Applicable motor size *2