The text of a manual · part 29 of 31

X200 Series Inverter Instruction Manual, pages 281 to 290

Pages 281 to 290 of 305

The original document is the PDF (8.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Hitachi X200 Series

Page 281

Appendix B

B−38

C102

Reset selection

C141

Input A select for logic output Input B select for logic output Logic function select

C142 C143

Determines response to Reset input [RS]. Three option codes: 00}Cancel trip state at input signal ON transition, stops inverter if in Run Mode 01}Cancel trip state at signal OFF transition, stops inverter if in Run Mode 02}Cancel trip state at input ON transition, no effect if in Run Mode R/W R/W

See “Output Logic and Timing” on page 3–63

R/W Applies a logic function to calculate [LOG] output state, Three options: 00}[LOG] = A AND B 01}[LOG] = A OR B 02}[LOG] = A XOR B

0, 1, 2

1150h 0, 1, 2, 3, 4, 5, 6, 7, 1151h 8, 10, 43

1152h

114Ah

0, 1, 2

Page 282

B−39

List of Holding Registers Func. Code C144 C145 C148 C149

Name Terminal [11] ON delay Terminal [11] OFF delay Output relay ON delay Output relay OFF delay

Note 1:

R/W

Description

R/W Range is 0.0 to 100.0 sec. R/W Range is 0.0 to 100.0 sec. R/W Range is 0.0 to 100.0 sec. R/W Range is 0.0 to 100.0 sec.

Network Data Reg. Range Res. 1153h 0 to 1000 0.1 sec 1154h 0 to 1000 0.1 sec 1157h 0 to 1000 0.1 sec 1158h 0 to 1000 0.1 sec

Assume that the inverter current rating is 10000 (for C041).

List of Holding Registers Func. Name Code H003 Motor capacity

H203 Motor capacity, 2nd motor

H004 Motor poles setting H204 Motor poles setting, 2nd motor H006 Motor stabilization constant H206 Motor stabilization constant, 2nd motor

R/W

Description

R/W 0…0.20kW 1…0.37kW 2…0.40kW 3…0.55 kW 4…0.75 kW 5…1.10 kW R/W 6…1.50 kW 7…2.2 kW 8…3.0 kW 9…3.7 kW 10…4.0 kW 11…5.5 kW 12…7.5 kW 13…11.0kW R/W Four selections: 2/4/6/8 R/W R/W Motor constant (factory set), range is 0 to 255 R/W

Network Data Reg. Range Res. 1165h 0 to 13

1541h

0 to 13

1166h

2, 4, 6, 8

1 pole

1542h

2, 4, 6, 8

1 pole

1168h

0 to 255

1

1544h

0 to 255

1

Appendix B Appendix B

The following table lists the holding registers for the “H” Group Motor Constants.

Page 283

This page is a scan with no text; see it in the PDF.

Page 284

C−1

Drive Parameter Setting Tables In This Appendix…

C page

-

Introduction...................................................................................... 2

-

Parameter Settings for Keypad Entry ............................................ 2

AppendixAppendix C C

Page 285

C−2

Introduction This appendix lists the user-programmable parameters for the X200 series inverters and the default values for European and U.S. product types. The right-most column of the tables is blank, so you can record values you have changed from the default. This involves just a few parameters for most applications. This appendix presents the parameters in a format oriented toward the keypad on the inverter.

Parameter Settings for Keypad Entry

Appendix C

Appendix C

X200 series inverters provide many functions and parameters that can be configured by the user. We recommend that you record all parameters that have been edited, in order to help in troubleshooting or recovery from a loss of parameter data.

Inverter model

This information is printed on the specification label located on the right side of the inverter

X200

MFG. No.

Main Profile Parameters NOTE:. Mark “9” in B031=10 shows the accessible parameters when B031 is set “10”, high level access. “F” Group Parameters Func. Name Code F001 Output frequency setting F002 Acceleration (1) time setting F202 Acceleration (1) time setting, 2nd motor F003 Deceleration (1) time setting F203 Deceleration (1) time setting, 2nd motor F004 Cumulative power-on time monitor

Default Setting -FE -FU (EU) (USA) 0.0 0.0 10.0 10.0 10.0 10.0

B031 =10 9 9 9

10.0 10.0

10.0 10.0

9 9

00

00

U

User Setting

Page 286

C−3

Standard Functions NOTE:. Mark “9” in B031=10 shows the accessible parameters when B031 is set “10”, high level access. “A” Group Parameters

A012 A013 A014 A015 A016 A020 A220 A021 A022 A023 A024 A025 A026 A027 A028 A029 A030 A031 A032 A033 A034 A035 A038 A039 A041 A241 A042 A242

Name Frequency source setting Frequency source setting, 2nd motor Run command source setting Run command source setting, 2nd motor Base frequency setting Base frequency setting, 2nd motor Maximum frequency setting Maximum frequency setting, 2nd motor [AT] selection Pot./O-L input active range start frequency Pot./O-L input active range end frequency Pot./O-L input active range start voltage Pot./O-L input active range end voltage Pot./O-L input start frequency enable External frequency filter time constant Multi-speed 0 setting Multi-speed 0 setting, 2nd motor Multi-speed 1 setting Multi-speed 2 setting Multi-speed 3 setting Multi-speed 4 setting Multi-speed 5 setting Multi-speed 6 setting Multi-speed 7 setting Multi-speed 8 setting Multi-speed 9 setting Multi-speed 10 setting Multi-speed 11 setting Multi-speed 12 setting Multi-speed 13 setting Multi-speed 14 setting Multi-speed 15 setting Jog frequency setting Jog stop mode Torque boost select Torque boost select, 2nd motor Manual torque boost value Manual torque boost value, 2nd motor

Default Setting -FE -FU (EU) (USA) 01 00 01 00 01 02 01 02 50.0 60.0 50.0 60.0 50.0 60.0 50.0 60.0 02 02 0.0 0.0

B031 =10 U U U U U U U U 9 9

0.0

0.0

9

0. 100. 01 8. 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 1.00 00 00 00 1.8 0.0

0. 100. 01 8. 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 1.00 00 00 00 1.8 0.0

9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 U U 9 9

User Setting

AppendixAppendix C C

Func. Code A001 A201 A002 A202 A003 A203 A004 A204 A005 A011

Page 287

Appendix C

Appendix C

C−4

“A” Group Parameters Func. Name Code A043 Manual torque boost frequency adjustment A243 Manual torque boost frequency adjustment, 2nd motor A044 V/f characteristic curve selection A244 V/f characteristic curve selection, 2nd motor A045 V/f gain setting A245 V/f gain setting, 2nd motor A051 DC braking enable A052 DC braking frequency setting A053 DC braking wait time A054 DC braking force for deceleration A055 DC braking time for deceleration A056 DC braking / edge or level detection for [DB] input A061 Frequency upper limit setting A261 Frequency upper limit setting, 2nd motor A062 Frequency lower limit setting A262 Frequency lower limit setting, 2nd motor A063, Jump (center) frequency setting A065, A067 A064, Jump (hysteresis) frequency width A066, setting A068 A071 PID enable A072 PID proportional gain A073 PID integral time constant A074 PID derivative time constant A075 PV scale conversion A076 PV source setting A077 Reverse PID action A078 PID output limit A081 AVR function select A082 AVR voltage select A085 Operation mode selection A086 Energy saving mode tuning A092 Acceleration (2) time setting A292 Acceleration (2) time setting, 2nd motor A093 Deceleration (2) time setting A293 Deceleration (2) time setting, 2nd motor

Default Setting -FE -FU (EU) (USA) 10.0 10.0

B031 =10 9

0.0

0.0

9

00 00

00 00

U U

100. 100. 00 0.5 0.0 0. 0.0 01

100. 100. 00 0.5 0.0 0. 0.0 01

9 9 9 9 9 9 9 9

0.0 0.0

0.0 0.0

9 9

0.0 0.0

0.0 0.0

9 9

0.0 0.0 0.0 0.5 0.5 0.5 00 1.0 1.0 0.0 1.00 00 00 0.0 00 230/400 00 50.0 15.00 15.00 15.00 15.00

0.0 0.0 0.0 0.5 0.5 0.5 00 1.0 1.0 0.0 1.00 00 00 0.0 00 230/460 00 50.0 15.00 15.00 15.00 15.00

9

9

9 9 9 9 9 9 9 9 U U U U 9 9 9 9

User Setting

Page 288

C−5

Default Setting -FE -FU (EU) (USA) 00 00

B031 =10

User Setting

U

00

00

U

0.0 0.0

0.0 0.0

U U

0.0 0.0

0.0 0.0

U U

00 00 0.0

00 00 0.0

U U 9

0.0

0.0

9

0. 100. 01 01 02 00 0.0 00 0.0 0.0 0. 100. 01

0. 100. 01 01 02 00 0.0 00 0.0 0.0 0. 100. 01

9 9 9 9 9 9 9 9 9 9 9 9 9

AppendixAppendix C C

“A” Group Parameters Func. Name Code A094 Select method to switch to Acc2/Dec2 profile A294 Select method to switch to Acc2/Dec2 profile, 2nd motor A095 Acc1 to Acc2 frequency transition point A295 Acc1 to Acc2 frequency transition point, 2nd motor A096 Dec1 to Dec2 frequency transition point A296 Dec1 to Dec2 frequency transition point, 2nd motor A097 Acceleration curve selection A098 Deceleration curve selection A101 [OI]-[L] input active range start frequency A102 [OI]-[L] input active range end frequency A103 [OI]-[L] input active range start current A104 [OI]-[L] input active range end voltage A105 [OI]-[L] input start frequency enable A141 A input select for calculate function A142 B input select for calculate function A143 Calculation symbol A145 ADD frequency A146 ADD direction select A151 POT active range start frequency A152 POT input active range end frequency A153 POT input active range start A154 POT input active range end A155 POT input start frequency enable

Page 289

C−6

Fine Tuning Functions

Appendix C

Appendix C

“B” Group Parameters Func. Name Code B001 Selection of automatic restart mode B002 Allowable under-voltage power failure time B003 Retry wait time before motor restart B004 Instantaneous power failure / undervoltage trip alarm enable B005 Number of restarts on power failure / under-voltage trip events B011 Start freq to be used in case of freq matching restart B012 Level of electronic thermal setting B212 B013 B213 B021 B221 B022 B222 B023 B223 B028 B228 B029 B030 B031 B050 B051 B052 B053 B054 B055 B056

Level of electronic thermal setting, 2nd motor Electronic thermal characteristic Electronic thermal characteristic, 2nd motor Overload restriction operation mode Overload restriction operation mode, 2nd motor Overload restriction level setting Overload restriction operation mode, 2nd motor Deceleration rate at overload restriction Overload restriction operation mode, 2nd motor Source of overload restriction selection Source of overload restriction selection, 2nd motor Deceleration rate of frequency matching restart setting Current level of frequency matching restart setting Software lock mode selection Selection of the non stop operation Non stop operation start voltage setting OV-LAD Stop level of non stop operation setting Deceleration time of non stop operation setting Frequency width of quick deceleration setting DC bus AVR P-gain DC bus AVR I-time

Default Setting -FE -FU (EU) (USA) 00 00 1.0 1.0

B031 =10 9 9

1.0 00

1.0 00

9 9

00

00

9

00

00

U

Rated current for each inverter Rated current for each inverter 01 01 01 01 01 01

01 01

Rated current x 1.5 Rated current x 1.5

9 9 9 9 9 9 9 9

1.0 1.0

30.0 30.0

9 9

00 00

00 00

9

0.5

0.5

U

Rated current

U

01 00 0.0 0.0

01 00 0.0 0.0

9 9 9 U

1.0

1.0

U

0.0

0.0

U

0.2 0.2

0.2 0.2

9 9

User Setting

Page 290

C−7

“B” Group Parameters Func. Code B080 B082 B083 B084 B085 B086 B087 B088 B089

B140 B150 B151

[AM]analog signal gain Start frequency adjustment Carrier frequency setting Initialization mode (parameters or trip history) Country for initialization Frequency scaling conversion factor STOP key enable Restart mode after FRS Monitor display select for networked inverter Stop mode selection Cooling fan control Over-voltage LADSTOP enable Over-voltage LADSTOP level DC bus AVR selection Threshold voltage of DC bus AVR setting Over-current trip suppression Carrier mode Selection of RDY function

Default Setting -FE -FU (EU) (USA) 100. 100. 0.5 0.5 3.0 3.0 00 00 01 1.0 00 00 01

02 1.0 00 00 01

00 00 00 00 00 00 380 / 760 380 / 760 00 00 380/760 380/760 00 00 00

00 00 00

B031 =10

User Setting

9 9 U U U 9 9 9 9 U U 9 9 9 9 9 9 9

AppendixAppendix C C

B091 B092 B130 B131 B133 B134

Name