Operation guide for the OMRON SYSMAC C200H-AD001 Analog Input Unit and C200H-DA001 Analog Output Unit for C200H and C200HS PCs.
What this file really is
The old site listed this file as a manual for the Omron C500-AD001. Linked as the C500-AD001 manual, but it is the operation guide for the C200H-AD001 and C200H-DA001 Analog I/O Units for the C200H and C200HS PCs.
Filed with · 1 model
Also filed with these models on the old site
Summary
What is in it
OMRON's operation guide for the C200H-AD001 Analog Input Unit and the C200H-DA001 Analog Output Unit, analog-digital and digital-analog converters for the C200H or C200HS PC. After precautions and a system design section, each unit gets its own section covering nomenclature, switch settings, wiring, bit and DM area allocations, functions such as scaling, mean value, peak value, square root, output limits and pulse output, programming examples and troubleshooting. Appendices list standard models, specifications and data memory coding sheets.
Its parts
- Precautions
- System Design
- C200H-AD001 Analog Input Unit
- C200H-DA001 Analog Output Units
From the manual
Key facts from this manual
Each line names its page in the PDF.
Operation guide for the Omron SYSMAC C200H-AD001 Analog Input Unit and C200H-DA001 Analog Output Unit, used with C200H and C200HS PCs. The site files it under the C500-AD001, but the guide covers only the two C200H units. It explains switch settings, wiring, the built-in functions, troubleshooting, and the specifications of both units.
- Devices
- C200H-AD001 Analog Input Unit (A/D) and C200H-DA001 Analog Output Unit (D/A) for C200H or C200HS PCs p. 4
- Analog inputs
- C200H-AD001: up to 4 inputs, converted to 12-bit binary p. 4, 55
- Input ranges
- C200H-AD001: 1 to 5 V, 4 to 20 mA, or 0 to 10 V (voltage inputs only) p. 4
- Input resolution
- C200H-AD001: 1/4000 max. (full scale); conversion time 2.5 ms max. per point p. 55
- Analog outputs
- C200H-DA001: 2 outputs from 12-bit binary data; 1 to 5 V, 4 to 20 mA, or 0 to 10 V p. 4, 57
- Output accuracy
- C200H-DA001: resolution 1/4095 max.; accuracy ±0.5% max. at 25°C, ±1.0% max. at 0° to 55°C (full scale) p. 57
- Output drive
- C200H-DA001: voltage output 15 mA max., 0.5 Ω max. output impedance; current output 400 Ω max. load p. 57
- Power consumption
- C200H-AD001: 550 mA max. at 5 VDC; C200H-DA001: 650 mA max. at 5 VDC p. 55, 57
- Terminals
- 19-pin removable terminal block on both units p. 55, 57
- Size and weight
- 34.5 x 130 x 128 (W x H x D) mm, 450 g max., same for both units p. 55, 57, 58
- Input functions
- C200H-AD001: scaling, mean value, peak value, square root, and input disconnection detection p. 4, 16
- Output functions
- C200H-DA001: output limit, output limit alarm, and a 0 V to 5 V pulse output separate from the analog output p. 4, 37
- Alarm outputs
- C200H-DA001: open-collector upper and lower limit alarm outputs, 100 mA max. per circuit, 5 to 24 VDC p. 40, 41
- Unit number
- 0 to 9 on the front switch, a different number for each unit; factory set to 0 p. 18
What this manual walks you through
- Planning how many Special I/O Units a PC and its Slave Racks can hold p. 14
- Setting the unit number and the number of enabled inputs p. 18
- Wiring analog inputs to keep out noise p. 22
- Troubleshooting disconnection, setting and CPU errors on the input unit p. 34, 35
- Restarting a Special I/O Unit with the AR restart bits p. 35
- Wiring the analog, pulse and alarm outputs of the C200H-DA001 p. 40, 41
Good to know
- Input signals beyond the maximum ratings damage the C200H-AD001. p. 55
- On a C200H, an Analog I/O Unit must not go in the two slots next to the CPU, or the Programming Console cannot be connected. p. 14
- Special I/O Units cannot be used on a C200H Remote I/O Slave Rack connected to a C500, C1000H, or C2000H PC. p. 14
- A single C200H-DA001 output line cannot give voltage and current output at the same time. p. 41
- Turn off the PC power before installing or disconnecting units or connecting lines. p. 14
Questions this manual answers
What input ranges does the C200H-AD001 accept?
1 to 5 V, 4 to 20 mA, or 0 to 10 V. The 0 to 10 V range is for voltage inputs only. p. 4
Why is the BROKEN WIRE light on my C200H-AD001 lit?
An input signal wire is disconnected. The indicator works only with the 1 to 5 V or 4 to 20 mA range; check the input wires, terminal block and input voltage. p. 16, 34
How many analog outputs does the C200H-DA001 have?
Two, each set to 1 to 5 V, 4 to 20 mA, or 0 to 10 V. p. 57
What causes an I/O UNIT OVER error?
Two or more Special I/O Units set to the same unit number. The PC then will not operate. p. 18
Contents
Chapters and sections
Each line opens the PDF at its page.
The whole text · 9 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
- Pages 1 to 41-4
- Pages 5 to 95-9
- SECTION 1 - System Design10-14
- SECTION 2 - C200H-AD001 Analog Input Unit, pages 15 to 2115-21
- SECTION 2 - C200H-AD001 Analog Input Unit, pages 22 to 2822-28
- SECTION 2 - C200H-AD001 Analog Input Unit, pages 29 to 3529-35
- SECTION 3 - C200H-DA001 Analog Output Units, pages 36 to 4436-44
- SECTION 3 - C200H-DA001 Analog Output Units, pages 45 to 5345-53
- Pages 54 to 6154-61