Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact

The text of a manual · part 1 of 14

Optimation OptiLogic Driver Help: Table of Contents

Pages 1 to 5 of 119, from Optimation OptiLogic Driver Help

The original document is the PDF (1.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Optimation OL4054 and Optimation OL4058

Page 1

Optimation OptiLogic Driver Help © 2012 Kepware Technologies

Page 2

Optimation OptiLogic Driver Help

2

Table of Contents Table of Contents

2

Optimation OptiLogic Driver Help

5

Overview

5

Device Setup

6

Optimizing Your Optimation OptiLogic Communications

8

Data Types Description

9

Address Descriptions

10

Digital I/O Bit Mapping

10

4 Digital Input Module

11

8 Digital Input Module

11

16 Digital Input Module

12

24 Digital Input Module

13

32 Digital Input Module

13

4 Digital Output Module

14

8 Digital Output Module

16

16 Digital Output Module

19

24 Digital Output Module

21

32 Digital Output Module

23

2 Channel Analog Input Module

25

4 Channel Analog Input Module

26

8 Channel Analog Input Module

26

16 Channel Analog Input Module

27

2 Channel Analog Output Module

27

4 Channel Analog Output Module

28

8 Channel Analog Output Module

29

16 Channel Analog Output Module

29

High Speed Counter Module

30

2 Channel High Speed Counter Module

35

Base RS232 Port

38

Dual RS232 Port Module

42

OL3406 Operator Panel

47

OL3420 Operator Panel

50

OL3440 Operator Panel

54

OL3850 Operator Panel

54

4 Digital Output Module

59

8 Digital Output Module

61

8 Digital Output Module

63

8 Digital Output Module

66 www. kepware.com

Page 3

Optimation OptiLogic Driver Help

3

8 Digital Input Module

68

4 Digital Input Module

68

8 Digital Input Module

69

8 Digital Input Module

70

2 Channel High Speed Counter Module

70

High Speed Counter Module

73

4 Channel Analog Output Module

79

8 Channel Analog Input Module

80

8 Channel Analog Input Module

80

Dual RS232 Port Module

81

OL3406 Operator Panel

85

OL3420 Operator Panel

89

OL3440 Operator Panel

92

OL3850 Operator Panel

93

Base RS232 Port

97

Error Descriptions

103

OptiLogic Device Error Codes

104

Driver Error Messages

104

Winsock initialization failed (OS Error = n)

104

Winsock V1.1 or higher must be installed to use the OptiLogic device driver

104

Memory allocation error

104

Driver Warning Messages

104

Device '<device name>' is not responding

105

Device address <address> contains a syntax error

105

Address <address> is out of range for the specified device or register

105

Device address <address> is not supported by model <model name>

105

Device address <address> is Read Only

106

Array size is out of range for address <address>

106

Array support is not available for the specified address: <address>

106

Data type <type> is not valid for device address <address>

106

Base with type=<type> Major ver.=<major> Minor ver.=<minor> is currently not supported. Contact Technical Support

106

Module in slot <slot> w/ type=<type>, subtype=<subtype> is currently not supported. Contact Technical Support

107

Panel with type=<type>, subtype=<subtype> is currently not supported. Contact Technical Support

107

Read Errors

107

Frame received from device <device name> contains errors

107

Base module referenced in address <address> on device <device name> does not exist

108

Slot module referenced in address <address> on device <device name> does not exist

108

Panel module referenced in address <address> on device <device name> does not exist

108 www. kepware.com

Page 4

Optimation OptiLogic Driver Help

4

Address <address> contains an invalid address type for RTU module, device <device name>

108

Address <address> contains an invalid address type for module <subtype>, slot <slot>, device <device name>

108

Address <address> contains an invalid address type for panel module <subtype>, device <device name>

109

Address <address> is out of range for module <subtype> in slot <slot>, device <device name>

109

Address <address> is out of range for panel module <subtype>, device <device name>

109

Port <port> of the base module returned an error with value = <error value>

109

Module <subtype> in slot <slot> returned an error with value = <error value>

109

Port <port> of module <subtype> in slot <slot> returned an error with value = <error value>

110

Panel module <subtype> returned an error with value = <error value>

110

Write Errors

110

Unable to write to <address> on device <device name>

111

Write failed. Frame received from device <device name> contains errors

111

Write rejected. Base module referenced in address <address> on device <device name> does not exist

Write rejected. Slot module referenced in address <address> on device <device name> does not exist

Write rejected. Panel module referenced in address <address> on device <device name> does not exist Write rejected. Address <address> contains an invalid address type for RTU module, device <device name>

111 111 112 112

Write rejected. Address <address> contains an invalid address type for module <subtype>, slot <slot>, device <device name> 112 Write rejected. Address <address> contains an invalid address type for panel module <subtype>, device <device name>

112

Write rejected. Address <address> is out of range for module <subtype> in slot <slot>, device <device name> 112 Write rejected. Address <address> is out of range for panel module <subtype>, device <device name>

113

Write failed. Port <port> of the base module returned an error with value = <error value>

113

Write failed. Module <subtype> in slot <slot> returned an error with value = <error value>

113

Write failed. Port <port> of module <subtype> in slot <slot> returned an error with value = <error value>

113

Write failed. Panel module <subtype> returned an error with value = <error value>

114

Index

115 www. kepware.com

Page 5

Optimation OptiLogic Driver Help

5 Optimation OptiLogic Driver Help Help version 1.012

CONTENTS Overview What is the Optimation OptiLogic Driver? Device Setup How do I configure a device for use with this driver? Optimizing Your Optimation OptiLogic Communications How do I get the best performance from the Optimation OptiLogic Driver? Data Types Description What data types does this driver support? Address Descriptions How do I address data locations? Error Descriptions What error messages does the Optimation OptiLogic Driver produce?

Overview The Optimation OptiLogic Driver provides an easy and reliable way to connect Optimation OptiLogic devices to OPC Client applications, including HMI, SCADA, Historian, MES, ERP and countless custom applications. It is intended for use with Optimation OptiLogic Series Remote Terminal Units, I/O Modules and Operator Panels.

www. kepware.com