The text of a manual ยท part 2 of 14
Optimation OptiLogic Driver Help, pages 6 to 8
Pages 6 to 8 of 119: Device Setup; Optimizing Your Optimation OptiLogic Communications
The original document is the PDF (1.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Optimation OL4054 and Optimation OL4058
Page 6
Optimation OptiLogic Driver Help
6
Device Setup Supported RTUs OL4054 OL4058
Supported Modules OL2208, OL2211, OL2201 OL2108, OL2109, OL2111 OL2408, OL2418 OL2252 OL3406, OL3420, OL3440, OL3850
Communication Protocol Ethernet using Winsock V1.1 or higher.
Device IDs The Device ID is used to specify the device IP address along with an OptiLogic Node Number on the Ethernet network. Device IDs are specified as either YYY.YYY.YYY.YYY:XXX. The YYY designates the device IP address: each YYY byte should be in the range of 0 to 255. The XXX designates the OptiLogic node number of the RTU and can be in the range of 0 to 99. This allows up to 99 devices to be defined on a given channel. Note: Each device on the channel must be uniquely identified by its own IP address and Node ID. Users can use the OptiLogic Update Tool software supplied by Optimation to configure an RTU's IP address. Users can set the RTU Node ID using the address switches under the base unit cover.
Precision The default precision will be used when writing float data to the device. For example, if 50.02 is written from the client, the float value received by the server could be 50.019999. The driver needs to know the precision that should be used for this value. Thus, a bit number (representing the precision) should be appended to the address. A bit number of three would send the previous example as 50.019 with a precision of 3.
Configuration The Optimation OptiLogic Driver automatically detects the location of each module in the RTU. While certain I/O modules are required to use Slot 0, placement of others is flexible. For more information, refer to the specific module's owner manual. The number of slots varies with RTU: 4 for OL4054 and 8 for OL4058. Only one operator panel can be connected per RTU.
Cable Diagrams www. kepware.com
Page 7
Optimation OptiLogic Driver Help
Patch Cable (Straight Through)
TD + 1|OR/WHT ORMWHTI1 TD + TD- 2\|OR OR]? Tp- RD + 3IGRNAWHT GRN/JWHT|3 RD+
4|BLU BLU] 4
5 |BLUWHT BLUMWHT| 5 10 BaseT RD- 6|GRN GRN/6 RD-
7 |BRNWHT BRNMWHIT| 7
8|BRN BRN|g RJ45 RJ45
Crossover Cable 12345678
TD + 1|ORAWHT GRNIWHTI1 TD + TD- 2/OR GRNiotTp- | 8-pin RJ45 RD + 3/IGRN/WHT OR/JWHT!]3 RD +
4|BLU BLU} 4
5 [|BLUAWHT Lo BLUJWHT| 5 RD- 6/GRN OR!g RD-
7 |BRNJWHT BRNJWHT| 7
8 |BRN BRN|8 RJ45 RJ45 www. kepware.com
Page 8
Optimation OptiLogic Driver Help
8
Optimizing Your Optimation OptiLogic Communications The Optimation OptiLogic driver has been designed to provide the best performance with the least amount of impact on the system's overall performance. While the Optimation OptiLogic driver is fast, there are a couple of guidelines that can be used in order to control and optimize the application and gain maximum performance. Our server refers to communications protocols like Optimation OptiLogic as a channel. Each channel defined in the application represents a separate path of execution in the server. Once a channel has been defined, a series of devices must then be defined under that channel. Each of these devices represents a single OptiLogic RTU from which data will be collected. While this approach to defining the application will provide a high level of performance, it won't take full advantage of the Optimation OptiLogic driver or the network. An example of how the application may appear when configured using a single channel is shown below. Each device appears under a single channel. In this configuration, the driver must move from one device to the next as quickly as possible in order to gather information at an effective rate. As more devices are added or more information is requested from a single device, the overall update rate begins to suffer.
If the Optimation OptiLogic driver could only define one single channel, then the example shown above would be the only option available; however, the Optimation OptiLogic driver can define up to 100 channels. Using multiple channels distributes the data collection workload by simultaneously issuing multiple requests to the network. An example of how the same application may appear when configured using multiple channels to improve performance is shown below. Each device has now been defined under its own channel. In this new configuration, a single path of execution is dedicated to the task of gathering data from each device. If the application has 100 or fewer channels, it can be optimized exactly how it is shown here. The performance will improve even if the application has more than 100 channels. While 100 or fewer channels may be ideal, the application will still benefit from additional channels. Although spreading the device load across all channels will cause the server to move from device to device again, it can now do so with far less devices to process on a single channel.
www. kepware.com