Page 11

RS-485 Setup (Optional) READ THIS FIRST - The “RS-232/485” connector (also referred to as “COM2”) is factory-configured for RS-232 communication; this makes it compatible with an RP240 remote operator panel. If you are not using RS-485 communication, skip this section and proceed to Mounting.

Caution, Remove power before removing the 6K controller’s enclosure. While handling the 6k controller’s printed circuit assemblies, be sure to observe proper grounding techniques to prevent electrostatic discharge (ESD).

DIP Switch 8 7 6 5 4 3 2 1

2-wire RS-485 4-wire RS-485 Reserved Enable RS-485 120Ω Rx termination resistor 120Ω Tx termination resistor 681Ω Tx+ bias resistor 681Ω Tx- bias resistor

RS-485 2Wire ON OFF OFF ON ON * ON * ON ON

RS-485 4Wire OFF ON OFF ON ON ON ON ON

RS-232 OFF OFF OFF OFF OFF OFF OFF OFF

* For 2-wire RS-485, use switch #3 or switch #4 for 120Ω termination (not both).

Chapter 1. Installation

5

Page 12 read from a scan by OCR; it may hold reading errors

6K Series Dimensions & Mounting

Dimensions 7.416 [188.37], - - - - - _ > 6K2 & 6K4 > <2 See O0000OO00000 | | 20000 » O0000 0UC_tUu

3.184 [80.87] il nr nm ne Mm oS oe Oe oe a | (| r > 1.000 [25.40] 5 0.00000 = OmromrO=) eto] 4 ae joia\ieC_ js Ale 00 0 aeOe|o\eC>2 to) 5.430 [137.92] || G <elalee mI @Cpa\ale_ 9 Fe [BRAN] compuneir MU Ne 3.680 [93.46], 4 000000 6K6 & 6K8 14.217 [361.11] 3275 (e319) | 20000000000000000000 \SgPL LP 200000000000 ACT RAT oe ee _ - oe ee, 3.184 [80.87] will 1.000 [25.40], ity 000 0 ® iN 0 q) 00 0 5.430 [137.92] 0 0 0 se WW 0 00 0 3.680 (93.46) -| 000000

6 6K Hardware Installation Guide

Page 13

Mounting Environmental Considerations Temperature - Operate the 6K in ambient temperatures between 32°F (0°C) and 122°F (50°C). Provide a minimum of 4 inches (100.6 mm) of unrestricted air-flow space around the 6K chassis. Fan cooling may be necessary if adequate air flow is not provided. Humidity - Keep below 95%, non-condensing. Airborne Contaminants, Liquids - Particulate contaminants, especially electrically conductive material, such as metal shavings and grinding dust, can damage the 6K. No not allow liquids or fluids to come in contact with the 6K or its cables.

Mounting Option, DIN Rail

Mounting Option, Brackets (brackets provided in ship kit)

Chapter 1. Installation

7

Page 14

6K Series Electrical Connections Encoder Connections. See page 19. Drive Connections. See page 10 for servos, page 15 for steppers. RS-232 (“COM1”). See page 25.

Master Encoder Connections. See page 19. Ethernet Connection. See page 25. Expansion I/O Connection. (“EVM32”) See page 43. “COM2”: RP240 (page 28). RS-485 (page 5 & 26)

Trigger Input Connections. See page 21. Programmable Outputs. See page 21. Limit Input Connections. See page 20.

Auxiliary Connections • +24 VDC PWR ......... +24 VDC power input. See page 29. • 24 VDC RTN............. 24 VDC power return. See page 29. • VINref ....................... Voltage reference for trigger, limit, drive fault, and enable inputs (default is 24 VDC; if 24 VDC is desired, it is not necessary to connect an external power source to the VINref terminal). Switching: ≤ 1/3 VINref = Low; ≥ 2/3 VINref = High. • TRIG-P * ................... Pull-up for trigger inputs. No connection necessary for pull-up to 24 VDC. See page 21. • LIM-P *...................... Pull-up for limit inputs. No connection necessary for pull-up to 24 VDC. See page 20. • CNTRL-P *................ Pull-up for drive fault inputs. No connection necessary for pull-up to 24 VDC. See page 10 and 15. • GND.......................... Isolated logic ground. • MASTER TRIG ......... Master Trigger Input. See page 10. • OUT DIODE.............. The 6K is shipped from the factory with this pin connected to 24 VDC power with an external jumper; this uses the internal flyback diode for onboard outputs that are driving inductive loads. DISCONNECT the jumper if the onboard outputs are not driving inductive loads. • ENABLE ................... Enable Input (must be connected to GND to allow motion). See page 9. • GND.......................... Isolated logic ground. • SHIELD..................... Internally connected to chassis earth ground. * The only reason to use the pull-up terminals is to change the respective inputs from sourcing VINref (factory default) to sinking. If sourcing inputs is appropriate for your application, then leave the pull-ups not connected. Note that the factory default is for the inputs to source 24 VDC; if sourcing other than 24 VDC is desired, connect the other voltage to the VINref terminal (e.g., to source 12VDC, connect a user-supplied 12VDC supply to the VINref terminal.

8

6K Hardware Installation Guide

Page 15

Enable Input The 6K controller is shipped from the factory with the ENABLE input jumpered to ground, thus allowing motion “out of the box” for bench-testing purposes. Use the diagram below as a guide for connecting the ENABLE input according to your application’s needs.

Chapter 1. Installation

9

Page 16

Drives: Servo (±10V) Drives

(“DRIVES” connectors)

Internal Schematics

Drive Cable: Maximum recommended length is 15 feet (4.56 m). Use 22 AWG wire.

10

6K Hardware Installation Guide

Page 17

Pin Outs & Specifications, Servo Drives Only (15-Pin “Drive” Connectors) Pin * Name

In/Out

71-017003-10 Description Cable Colors ***

3

OUT

Black

CMD +

Command signal output to the drive. ±10VDC analog output. 12-bit DAC. Load should be >2kΩ impedance.

5

DFT

IN

Drive fault input. Set active level with the DRFLVL command (default is active low). The drive

Green fault input will not be recognized until you send a DRFEN1 command (enables the input) to the axis. Voltage range for the DFT input is 0-24V. Switching levels: Low ≤ 1/3 VINref voltage, High ≥ 2/3 VINref voltage (factory default VINref voltage is +24 VDC, but you can connect a different voltage to the VINref terminal**). To make DFT a sinking input, connect the CNTRL-P terminal** to the GND terminal**. 6

CMD –

IN

Red

7

SHTNO

OUT

Brown

Command signal return. Shutdown relay output to drives that require an open contact to disable the drive. The shutdown relay is active (disabling the drive) when no power is applied to the 6K. When the 6K is powered up, the shutdown relay remains active until you issue the DRIVE1 command to the axis. Max. rating: 175 VDC, 0.25A, 3W. Shutdown active (DRIVEØ): this output is disconnected from COM. Shutdown inactive (DRIVE1): this output is internally connected to COM. (see schematic above)

8

SHTNC

OUT

Gray

Shutdown relay output to drives that require a closed contact to disable the drive. The shutdown relay is active (disabling the drive) when no power is applied to the 6K. When the 6K is powered up, the shutdown relay remains active until you issue the DRIVE1 command to the axis. Max. rating: 175 VDC, 0.25A, 3W. Shutdown active (DRIVEØ): this output is internally connected to COM. Shutdown inactive (DRIVE1): this output is disconnected from COM. (See schematic above)

13

ISO GND -----

White

Isolated logic ground.

14

COM

Yellow

Signal common for shutdown. Not connected to any ground or other COM.

15 * ** ***

AGND ----Blue Analog ground. Pin 1, 2, 4, and 9-12 are reserved for connection to a step & direction drive (see page 17). The VINref, CNTRL-P, and GND terminals are located on the screw-terminal connector on top of the 6K chassis. The servo drive cable (p/n 71-017003-10) is a 10-foot cable with no connector on the drive end of the cable. It is sold as an accessory.

-----

CONNECTIONS TO THE APEX SERIES DRIVE 6K Connections

APEX Drive Connections Signal Name Enable In

Signal Name Connector ↔ SHTNO Drive

Fault Out

↔ DFT

Drive

5

GND

↔ AGND

Drive

15

COM

Drive

14

Command +

↔ CMD +

Drive

3

Command –

↔ CMD –

Drive

6

CHA +

↔ A+

Encoder

2

CHA –

↔ A–

Encoder

3

CHB +

↔ B+

Encoder

4

CHB –

↔ B–

Encoder

5

CHZ +

↔ Z+

Encoder

6

CHZ – GND

↔ Z– ↔ GND

Encoder Encoder

7 9

Chapter 1. Installation

11

Pin 7 Jumper AGND to COM.

Page 18

CONNECTIONS TO THE ARIES SERIES DRIVE Aries Drive Connections

6K Connections

Signal Name

Connector

Pin

GND

Drive I/O

2

Enc out A+

Drive I/O

3

Enc out A-

Drive I/O

4

Enc out B+

Drive I/O

5

Enc out B-

Drive I/O

6

Enc out Z+

Drive I/O

7

Enc out Z-

Drive I/O

8

ENABLE+

Drive I/O

1

FAULT+

Drive I/O

9

AIN+

Drive I/O

14

AIN-

Drive I/O

15

FAULT-

Drive I/O

16

GND

Drive I/O

ENABLE-

Drive I/O

Signal Name Connector

Pin

↔ GND ↔ A+

Encoder

9

Encoder

2

↔ A↔ B+

Encoder

3

Encoder

4

↔ B↔ Z+

Encoder

5

Encoder

6

↔ ZEncoder ↔ SHUTDOWN- Drive ↔ DRF Drive

12

7 5

↔ CMD+ ↔ CMD-

Drive

3

Drive

6

Drive

13

17

↔ GND ↔ GND

Drive

13

21

↔ SHUTDOWN+ Drive

11

CONNECTIONS TO THE BD-E DRIVE BD-E Drive Connections

6K Connections

Signal Name

Connector Pin

Signal Name Connector

V2

User I/O

1

Pin

↔

CMD –

Drive

6

V1

User I/O

GND

User I/O

2

↔

CMD +

Drive

3

4

↔

GND

Encoder

RST

9

User I/O

5

↔

COM

Drive

14

+15V

User I/O

6

↔

SHTNO

Drive

7

SHTNC

Drive

8

FT

User I/O

9

↔

DFT

Drive

5

AOP

User I/O

10

↔

A+

Encoder

2

AOP

User I/O

11

↔

A–

Encoder

3

BOP

User I/O

12

↔

B+

Encoder

4

BOP

User I/O

13

↔

B–

Encoder

5

ZOP

User I/O

14

↔

Z+

Encoder

6

ZOP

User I/O

15

↔

Z–

Encoder

7

NOTE: These connections will work only of the BD-E’s jumper LK2 is set to position B (this is not the factory default setting).

12

6K Hardware Installation Guide

Jumper SHTNC to ground (GND).

Page 19

CONNECTIONS TO THE COMPAX3 DRIVE Compax3 Drive Connections

Jumper pins 6 & 8.

Jumper pins 1, 7, & 11.

6K Connections

Signal Name

Connector

Pin

Analog input + x11

9

↔ CMD+

Drive

3

Analog input - x11

11

↔ CMD-

Drive

6

Output 0 x12

2

↔ DFT

Drive

5

GND 24V x12

15

↔ GND

Drive

13

Input 0 x12

6

↔ COM

Drive

14

Input 1 x12

7

↔ SHTNO

Drive

7

2

Input 2 x12

8

24 V+ Out x12

1

Signal Name Connector

Pin

24V In for Outputs x12

11

A x11

7

↔ A+

Encoder

A/ x11

6

↔ A-

Encoder

3

B x11

8

↔ B+

Encoder

4

B/ x11

12

↔ B-

Encoder

5

N x11

14

↔ Z+

Encoder

6

N/ x11

13

↔ Z-

Encoder

7

GND x11

15

↔ GND

Encoder

9

CONNECTIONS TO THE DYNASERV DRIVE Dynaserv Drive Connections

6K Connections

Signal Name

Connector

Pin

DN1 DN1

13 14

Signal Name Connector ↔ A+ Encoder ↔ A– Encoder

Pin

A+ V1 SRVON

DN1

23

↔ SHTNO

Drive

7

VCC

DN1

24

↔ +5V

Encoder

1

B+

DN1

29

↔ B+

Encoder

4

B–

DN1

30

↔ B–

Encoder

5

Z+

DN1

43

↔ Z+

Encoder

6

Z–

DN1

44

↔ Z–

Encoder

7

VIN

DN1

49

↔ CMD +

Drive

3

AGND

DN1

50

↔ AGND

Drive

15

COM

Drive

14

GND

Encoder

9

2 3

NOTE: The Dynaserv’s default setting is for Position Mode (for accepting step and direction command signals). The connections above assume the Dynaserv is reconfigured for Velocity Mode or Torque Mode. Refer to the Dynaserv user guide for additional information.

Chapter 1. Installation

13

Jumper COM to ground (GND).

Page 20

CONNECTIONS TO THE DYNASERV GE DRIVE Dynaserv GE Drive Connections Signal Name

Connector

Pin

ACMD IN+

CN4

35

ACMD IN-

6K Connections Signal Name Connector

Pin

↔

CMD+

Drive

3

CN4

36

↔

CMD-

Drive

6

DRV RDY OUT CN4

4

↔

DFT

Drive

5

COMPN1

CN4

2

↔

GND

Drive

13

COMPN1

CN4

2

↔

COM

Drive

14

SERVO ON IN

CN4

20

↔

SHTNO

Drive

7

COMP1

CN4

1

↔

5 VOLTS+

Encoder

1

UA OUT+

CN4

9

↔

A+

Encoder

2

UA OUT-

CN4

10

↔

A-

Encoder

3

DB OUT+

CN4

11

↔

B+

Encoder

4

DB OUT-

CN4

12

↔

B-

Encoder

5

Z OUT+

CN4

13

↔

Z+

Encoder

6

Z OUT-

CN4

14

↔

Z-

Encoder

7

COMPN1

CN4

2

↔

GND

Encoder

9

Jumper pins 13 & 14.

CONNECTIONS TO THE LINEARSERV DRIVE Linearserv Connections

6K Connections

Signal Name

Connector Pin

Com +

CN1

1

↔

Signal Name Connector +5V

Encoder

Pin 1

Servo On –

CN1

5

↔

SHTNO

Drive

7

A+

CN1

17

↔

A+

Encoder

2

B+

CN1

19

↔

B+

Encoder

4

Z+

CN1

21

↔

Z+

Encoder

6

Agnd-TQ

CN1

22

↔

CMD –

Drive

6

Vin-TQ

CN1

23

↔

CMD +

Drive

3 6

Agnd-VEL

CN1

24

↔

CMD –

Drive

Vin-VEL

CN1

25

↔

CMD +

Drive

3

Com –

CN1

26

↔

AGND

Drive

15

Ready +

CN1

31

↔

DFT

Drive

5

A–

CN1

41

↔

A–

Encoder

3

B–

CN1

43

↔

B–

Encoder

5

Z–

CN1

45

↔

Z–

Encoder

7

COM

Drive

14

GND

Encoder

9

NOTE: The Linearserv’s default setting is for Position Mode (for accepting step and direction command signals). The connections above assume the Linearserv is reconfigured for Velocity Mode or Torque Mode. Refer to the Linearserv user guide for additional information.

14

6K Hardware Installation Guide

When the Linearserv is in Torque Mode, connect Agnd-TQ to CMD –, and connect Vin-TQ to CMD +.

When the Linearserv is in Velocity Mode, connect Agnd-VEL to CMD –, and connect Vin-VEL to CMD +.