Page 11
RS-485 Setup (Optional) READ THIS FIRST - The “RS-232/485” connector (also referred to as “COM2”) is factory-configured for RS-232 communication; this makes it compatible with an RP240 remote operator panel. If you are not using RS-485 communication, skip this section and proceed to Mounting.
Caution, Remove power before removing the 6K controller’s enclosure. While handling the 6k controller’s printed circuit assemblies, be sure to observe proper grounding techniques to prevent electrostatic discharge (ESD).
DIP Switch 8 7 6 5 4 3 2 1
2-wire RS-485 4-wire RS-485 Reserved Enable RS-485 120Ω Rx termination resistor 120Ω Tx termination resistor 681Ω Tx+ bias resistor 681Ω Tx- bias resistor
RS-485 2Wire ON OFF OFF ON ON * ON * ON ON
RS-485 4Wire OFF ON OFF ON ON ON ON ON
RS-232 OFF OFF OFF OFF OFF OFF OFF OFF
* For 2-wire RS-485, use switch #3 or switch #4 for 120Ω termination (not both).
Chapter 1. Installation
5
Page 12
6K Series Dimensions & Mounting
Dimensions 7.416 [188.37], - - - - - _ > 6K2 & 6K4 > <2 See O0000OO00000 | | 20000 » O0000 0UC_tUu
3.184 [80.87] il nr nm ne Mm oS oe Oe oe a | (| r > 1.000 [25.40] 5 0.00000 = OmromrO=) eto] 4 ae joia\ieC_ js Ale 00 0 aeOe|o\eC>2 to) 5.430 [137.92] || G <elalee mI @Cpa\ale_ 9 Fe [BRAN] compuneir MU Ne 3.680 [93.46], 4 000000 6K6 & 6K8 14.217 [361.11] 3275 (e319) | 20000000000000000000 \SgPL LP 200000000000 ACT RAT oe ee _ - oe ee, 3.184 [80.87] will 1.000 [25.40], ity 000 0 ® iN 0 q) 00 0 5.430 [137.92] 0 0 0 se WW 0 00 0 3.680 (93.46) -| 000000
6 6K Hardware Installation Guide
Page 13
Mounting Environmental Considerations Temperature - Operate the 6K in ambient temperatures between 32°F (0°C) and 122°F (50°C). Provide a minimum of 4 inches (100.6 mm) of unrestricted air-flow space around the 6K chassis. Fan cooling may be necessary if adequate air flow is not provided. Humidity - Keep below 95%, non-condensing. Airborne Contaminants, Liquids - Particulate contaminants, especially electrically conductive material, such as metal shavings and grinding dust, can damage the 6K. No not allow liquids or fluids to come in contact with the 6K or its cables.
Mounting Option, DIN Rail
Mounting Option, Brackets (brackets provided in ship kit)
Chapter 1. Installation
7
Page 14
6K Series Electrical Connections Encoder Connections. See page 19. Drive Connections. See page 10 for servos, page 15 for steppers. RS-232 (“COM1”). See page 25.
Master Encoder Connections. See page 19. Ethernet Connection. See page 25. Expansion I/O Connection. (“EVM32”) See page 43. “COM2”: RP240 (page 28). RS-485 (page 5 & 26)
Trigger Input Connections. See page 21. Programmable Outputs. See page 21. Limit Input Connections. See page 20.
Auxiliary Connections • +24 VDC PWR ......... +24 VDC power input. See page 29. • 24 VDC RTN............. 24 VDC power return. See page 29. • VINref ....................... Voltage reference for trigger, limit, drive fault, and enable inputs (default is 24 VDC; if 24 VDC is desired, it is not necessary to connect an external power source to the VINref terminal). Switching: ≤ 1/3 VINref = Low; ≥ 2/3 VINref = High. • TRIG-P * ................... Pull-up for trigger inputs. No connection necessary for pull-up to 24 VDC. See page 21. • LIM-P *...................... Pull-up for limit inputs. No connection necessary for pull-up to 24 VDC. See page 20. • CNTRL-P *................ Pull-up for drive fault inputs. No connection necessary for pull-up to 24 VDC. See page 10 and 15. • GND.......................... Isolated logic ground. • MASTER TRIG ......... Master Trigger Input. See page 10. • OUT DIODE.............. The 6K is shipped from the factory with this pin connected to 24 VDC power with an external jumper; this uses the internal flyback diode for onboard outputs that are driving inductive loads. DISCONNECT the jumper if the onboard outputs are not driving inductive loads. • ENABLE ................... Enable Input (must be connected to GND to allow motion). See page 9. • GND.......................... Isolated logic ground. • SHIELD..................... Internally connected to chassis earth ground. * The only reason to use the pull-up terminals is to change the respective inputs from sourcing VINref (factory default) to sinking. If sourcing inputs is appropriate for your application, then leave the pull-ups not connected. Note that the factory default is for the inputs to source 24 VDC; if sourcing other than 24 VDC is desired, connect the other voltage to the VINref terminal (e.g., to source 12VDC, connect a user-supplied 12VDC supply to the VINref terminal.
8
6K Hardware Installation Guide
Page 15
Enable Input The 6K controller is shipped from the factory with the ENABLE input jumpered to ground, thus allowing motion “out of the box” for bench-testing purposes. Use the diagram below as a guide for connecting the ENABLE input according to your application’s needs.
Chapter 1. Installation
9
Page 16
Drives: Servo (±10V) Drives
(“DRIVES” connectors)
Internal Schematics
Drive Cable: Maximum recommended length is 15 feet (4.56 m). Use 22 AWG wire.
10
6K Hardware Installation Guide
Page 17
Pin Outs & Specifications, Servo Drives Only (15-Pin “Drive” Connectors) Pin * Name
In/Out
71-017003-10 Description Cable Colors ***
3
OUT
Black
CMD +
Command signal output to the drive. ±10VDC analog output. 12-bit DAC. Load should be >2kΩ impedance.
5
DFT
IN
Drive fault input. Set active level with the DRFLVL command (default is active low). The drive
Green fault input will not be recognized until you send a DRFEN1 command (enables the input) to the axis. Voltage range for the DFT input is 0-24V. Switching levels: Low ≤ 1/3 VINref voltage, High ≥ 2/3 VINref voltage (factory default VINref voltage is +24 VDC, but you can connect a different voltage to the VINref terminal**). To make DFT a sinking input, connect the CNTRL-P terminal** to the GND terminal**. 6
CMD –
IN
Red
7
SHTNO
OUT
Brown
Command signal return. Shutdown relay output to drives that require an open contact to disable the drive. The shutdown relay is active (disabling the drive) when no power is applied to the 6K. When the 6K is powered up, the shutdown relay remains active until you issue the DRIVE1 command to the axis. Max. rating: 175 VDC, 0.25A, 3W. Shutdown active (DRIVEØ): this output is disconnected from COM. Shutdown inactive (DRIVE1): this output is internally connected to COM. (see schematic above)
8
SHTNC
OUT
Gray
Shutdown relay output to drives that require a closed contact to disable the drive. The shutdown relay is active (disabling the drive) when no power is applied to the 6K. When the 6K is powered up, the shutdown relay remains active until you issue the DRIVE1 command to the axis. Max. rating: 175 VDC, 0.25A, 3W. Shutdown active (DRIVEØ): this output is internally connected to COM. Shutdown inactive (DRIVE1): this output is disconnected from COM. (See schematic above)
13
ISO GND -----
White
Isolated logic ground.
14
COM
Yellow
Signal common for shutdown. Not connected to any ground or other COM.
15 * ** ***
AGND ----Blue Analog ground. Pin 1, 2, 4, and 9-12 are reserved for connection to a step & direction drive (see page 17). The VINref, CNTRL-P, and GND terminals are located on the screw-terminal connector on top of the 6K chassis. The servo drive cable (p/n 71-017003-10) is a 10-foot cable with no connector on the drive end of the cable. It is sold as an accessory.
-----
CONNECTIONS TO THE APEX SERIES DRIVE 6K Connections
APEX Drive Connections Signal Name Enable In
Signal Name Connector ↔ SHTNO Drive
Fault Out
↔ DFT
Drive
5
GND
↔ AGND
Drive
15
COM
Drive
14
Command +
↔ CMD +
Drive
3
Command –
↔ CMD –
Drive
6
CHA +
↔ A+
Encoder
2
CHA –
↔ A–
Encoder
3
CHB +
↔ B+
Encoder
4
CHB –
↔ B–
Encoder
5
CHZ +
↔ Z+
Encoder
6
CHZ – GND
↔ Z– ↔ GND
Encoder Encoder
7 9
Chapter 1. Installation
11
Pin 7 Jumper AGND to COM.
Page 18
CONNECTIONS TO THE ARIES SERIES DRIVE Aries Drive Connections
6K Connections
Signal Name
Connector
Pin
GND
Drive I/O
2
Enc out A+
Drive I/O
3
Enc out A-
Drive I/O
4
Enc out B+
Drive I/O
5
Enc out B-
Drive I/O
6
Enc out Z+
Drive I/O
7
Enc out Z-
Drive I/O
8
ENABLE+
Drive I/O
1
FAULT+
Drive I/O
9
AIN+
Drive I/O
14
AIN-
Drive I/O
15
FAULT-
Drive I/O
16
GND
Drive I/O
ENABLE-
Drive I/O
Signal Name Connector
Pin
↔ GND ↔ A+
Encoder
9
Encoder
2
↔ A↔ B+
Encoder
3
Encoder
4
↔ B↔ Z+
Encoder
5
Encoder
6
↔ ZEncoder ↔ SHUTDOWN- Drive ↔ DRF Drive
12
7 5
↔ CMD+ ↔ CMD-
Drive
3
Drive
6
Drive
13
17
↔ GND ↔ GND
Drive
13
21
↔ SHUTDOWN+ Drive
11
CONNECTIONS TO THE BD-E DRIVE BD-E Drive Connections
6K Connections
Signal Name
Connector Pin
Signal Name Connector
V2
User I/O
1
Pin
↔
CMD –
Drive
6
V1
User I/O
GND
User I/O
2
↔
CMD +
Drive
3
4
↔
GND
Encoder
RST
9
User I/O
5
↔
COM
Drive
14
+15V
User I/O
6
↔
SHTNO
Drive
7
SHTNC
Drive
8
FT
User I/O
9
↔
DFT
Drive
5
AOP
User I/O
10
↔
A+
Encoder
2
AOP
User I/O
11
↔
A–
Encoder
3
BOP
User I/O
12
↔
B+
Encoder
4
BOP
User I/O
13
↔
B–
Encoder
5
ZOP
User I/O
14
↔
Z+
Encoder
6
ZOP
User I/O
15
↔
Z–
Encoder
7
NOTE: These connections will work only of the BD-E’s jumper LK2 is set to position B (this is not the factory default setting).
12
6K Hardware Installation Guide
Jumper SHTNC to ground (GND).
Page 19
CONNECTIONS TO THE COMPAX3 DRIVE Compax3 Drive Connections
Jumper pins 6 & 8.
Jumper pins 1, 7, & 11.
6K Connections
Signal Name
Connector
Pin
Analog input + x11
9
↔ CMD+
Drive
3
Analog input - x11
11
↔ CMD-
Drive
6
Output 0 x12
2
↔ DFT
Drive
5
GND 24V x12
15
↔ GND
Drive
13
Input 0 x12
6
↔ COM
Drive
14
Input 1 x12
7
↔ SHTNO
Drive
7
2
Input 2 x12
8
24 V+ Out x12
1
Signal Name Connector
Pin
24V In for Outputs x12
11
A x11
7
↔ A+
Encoder
A/ x11
6
↔ A-
Encoder
3
B x11
8
↔ B+
Encoder
4
B/ x11
12
↔ B-
Encoder
5
N x11
14
↔ Z+
Encoder
6
N/ x11
13
↔ Z-
Encoder
7
GND x11
15
↔ GND
Encoder
9
CONNECTIONS TO THE DYNASERV DRIVE Dynaserv Drive Connections
6K Connections
Signal Name
Connector
Pin
DN1 DN1
13 14
Signal Name Connector ↔ A+ Encoder ↔ A– Encoder
Pin
A+ V1 SRVON
DN1
23
↔ SHTNO
Drive
7
VCC
DN1
24
↔ +5V
Encoder
1
B+
DN1
29
↔ B+
Encoder
4
B–
DN1
30
↔ B–
Encoder
5
Z+
DN1
43
↔ Z+
Encoder
6
Z–
DN1
44
↔ Z–
Encoder
7
VIN
DN1
49
↔ CMD +
Drive
3
AGND
DN1
50
↔ AGND
Drive
15
COM
Drive
14
GND
Encoder
9
2 3
NOTE: The Dynaserv’s default setting is for Position Mode (for accepting step and direction command signals). The connections above assume the Dynaserv is reconfigured for Velocity Mode or Torque Mode. Refer to the Dynaserv user guide for additional information.
Chapter 1. Installation
13
Jumper COM to ground (GND).
Page 20
CONNECTIONS TO THE DYNASERV GE DRIVE Dynaserv GE Drive Connections Signal Name
Connector
Pin
ACMD IN+
CN4
35
ACMD IN-
6K Connections Signal Name Connector
Pin
↔
CMD+
Drive
3
CN4
36
↔
CMD-
Drive
6
DRV RDY OUT CN4
4
↔
DFT
Drive
5
COMPN1
CN4
2
↔
GND
Drive
13
COMPN1
CN4
2
↔
COM
Drive
14
SERVO ON IN
CN4
20
↔
SHTNO
Drive
7
COMP1
CN4
1
↔
5 VOLTS+
Encoder
1
UA OUT+
CN4
9
↔
A+
Encoder
2
UA OUT-
CN4
10
↔
A-
Encoder
3
DB OUT+
CN4
11
↔
B+
Encoder
4
DB OUT-
CN4
12
↔
B-
Encoder
5
Z OUT+
CN4
13
↔
Z+
Encoder
6
Z OUT-
CN4
14
↔
Z-
Encoder
7
COMPN1
CN4
2
↔
GND
Encoder
9
Jumper pins 13 & 14.
CONNECTIONS TO THE LINEARSERV DRIVE Linearserv Connections
6K Connections
Signal Name
Connector Pin
Com +
CN1
1
↔
Signal Name Connector +5V
Encoder
Pin 1
Servo On –
CN1
5
↔
SHTNO
Drive
7
A+
CN1
17
↔
A+
Encoder
2
B+
CN1
19
↔
B+
Encoder
4
Z+
CN1
21
↔
Z+
Encoder
6
Agnd-TQ
CN1
22
↔
CMD –
Drive
6
Vin-TQ
CN1
23
↔
CMD +
Drive
3 6
Agnd-VEL
CN1
24
↔
CMD –
Drive
Vin-VEL
CN1
25
↔
CMD +
Drive
3
Com –
CN1
26
↔
AGND
Drive
15
Ready +
CN1
31
↔
DFT
Drive
5
A–
CN1
41
↔
A–
Encoder
3
B–
CN1
43
↔
B–
Encoder
5
Z–
CN1
45
↔
Z–
Encoder
7
COM
Drive
14
GND
Encoder
9
NOTE: The Linearserv’s default setting is for Position Mode (for accepting step and direction command signals). The connections above assume the Linearserv is reconfigured for Velocity Mode or Torque Mode. Refer to the Linearserv user guide for additional information.
14
6K Hardware Installation Guide
When the Linearserv is in Torque Mode, connect Agnd-TQ to CMD –, and connect Vin-TQ to CMD +.
When the Linearserv is in Velocity Mode, connect Agnd-VEL to CMD –, and connect Vin-VEL to CMD +.
Jumper COM to ground (GND).