The text of a manual · part 3 of 7
6K Series Hardware Installation Guide, pages 21 to 30
Pages 21 to 30 of 70
The original document is the PDF (3.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Parker Compumotor 6K4
Page 21
CONNECTIONS TO THE OEM670T & OEM675T DRIVE 6K Connections
OEM67x Drive Connections Signal Name
Pin
CMD +
1
CMD –
2
FAULT
9
ENABLE
10
GND
11
Signal Name Connector ↔ CMD + ↔ CMD – ↔ DFT ↔ SHTNO
GND
16
↔ COM ↔ AGND
GND
7
↔ GND
Pin
Drive
3
Drive
6
Drive
5
Drive
7
Drive
14
Drive
15
Drive
13
CONNECTIONS TO THE SV DRIVE SV Drive Connections
Connect the SV’s GND (X13 pin 05) to the ground from the external 24 VDC power supply.
6K Connections
Signal Name
Connector Pin
SOLL +
X8
1
SOLL –
X8
2
N
X13
2
B
X13
3
A
X13
4
GND
X13
5
N/
X13
9
B/
X13
10
A/
X13
11
+5V In
X13
13
ENABLE
X10
1
Signal Name Connector ↔ CMD + ↔ CMD – ↔ Z+ ↔ B+
Pin
Drive
3
Drive
6
Encoder
6
Encoder
4
↔ A+ ↔ ISO GND
Encoder
2
Drive
13
↔ Z– ↔ B–
Encoder
7
Encoder
5
↔ A– ↔ +5V Out
Encoder
3
Encoder
1
Drive
14
Drive
5
Drive
7
FAULT OUTPUT X10
15
↔ COM ↔ DRIVE FLT
+24V OUT
X10
9
↔ SHTNO *
ENABLE GND +24V OUT GND
X10 X10
8 10
+24V IN GND for +24V
X10 X10
14 16
Short these term inals together
–
+
External 24VDC Power Supply
* The SHTNO relay output is active (disabling the drive) when no power is applied to the 6K. When the 6K is powered up, the shutdown relay remains active until you issue a DRIVE1 command to the axis. NOTE: Adding the 500Ω resistor assumes the drive fault input is pulled up. (CNTRL-P is internally pulled up to the voltage at the VINref terminal, if no voltage is connected to VINref, CNTRL-P is pulled up internally to 24 VDC.) However, if all axes are SV drives, do not connect the 500Ω resistor; instead, connect the CNTRL-P pin to GND.
Chapter 1. Installation
15
500Ω
See note below.
Page 22
CONNECTIONS TO THE TQ10 DRIVE 6K Connections
TQ Drive Connections
Jumper pins 04 and 10.
Signal Name
Pin
ENABLE IN
1
↔
Signal Name Connector Pin SHTNO
Drive
ENABLE GND
2
↔
COM
Drive
14
FAULT OUT +
3
↔
DFT
Drive
5
FAULT OUT –
4
↔
AGND
Drive
15
COMMAND +
7
↔
CMD +
Drive
3
COMMAND –
8
↔
CMD –
Drive
COMMAND SHLD
9
↔
(Cable Shield) ---------
GND
10
7
6 ----
CONNECTIONS TO THE Vix DRIVE Vix Drive Connections
16
6K Connections
Signal Name
Connector
Pin
Signal Name Connector
Pin
ANA1+ IN
X4
1
↔
CMD+
Drive
3
ANA1- IN
X4
2
↔
CMD-
Drive
6
↔
COM
Drive
14
0V
X4
3
↔
GND
Drive
13
ENABLE
X4
11
↔
SHTNO
Drive
7
FAULT OUTPUT
X4
6
↔
DRF
Drive
5
ENC. A+ OUT
X4
14
↔
A+
Encoder
2
ENC. A- OUT
X4
9
↔
A-
Encoder
3
ENC. B+ OUT
X4
15
↔
B+
Encoder
4
ENC. B- OUT
X4
10
↔
B-
Encoder
5
ENC. Z+ OUT
X4
5
↔
Z+
Encoder
6
ENC. Z- OUT
X4
4
↔
Z-
Encoder
7
6K Hardware Installation Guide
Jumper COM to ground (GND).
Page 23
Drives: Step & Direction Drives
(“DRIVES” connectors)
INTERNAL SCHEMATICS
Drive Cable: Maximum recommended length is 50 feet (15.24 m). Use 22 AWG wire.
Chapter 1. Installation
17
Page 24
PIN OUTS & SPECIFICATIONS, STEPPER DRIVES ONLY (15-pin “DRIVE” connectors) Pin * Name
In/Out
1
OUT
Step +
Description Differential output. Step (pulse) output to the drive. Step + signal is active high. Signal levels: Low ≤ 1.0 VDC @ -30 mA, High ≥ 3.5 VDC @ +30 mA.
2
Direction +
OUT
Differential output. High signal on Direction + specifies motion in the positive direction; Low signal on direction + specifies motion in the negative direction. Signal levels: Low ≤ 1.0 VDC @ -30 mA, High ≥ 3.5 VDC @ +30 mA.
4
Stall
IN
5
DFT
IN
Encoder-less Stall Detection input for use with the GEMINI drive. Drive fault input. Set active level with the DRFLVL command (default is active low). The drive fault input will not be recognized until you send a DRFEN1 command (enables the input) to the axis. Voltage range for the DFT input is 0-24V. Switching levels: Low ≤ 1/3 VINref voltage, High ≥ 2/3 VINref voltage (factory default VINref voltage is +24 VDC, but you can connect a different voltage to the VINref terminal**). To make DFT a sinking input, connect the CNTRL-P terminal** to the GND terminal**.
9
Step –
OUT
10
Direction –
OUT
Differential output. Step (pulse) output to the drive. Step – signal is active low. Differential output. Low signal on Direction – specifies motion in the positive direction; High signal on direction – specifies motion in the negative direction.
11
Shutdown + OUT
Differential output. This signal is used to turn off current in the motor windings. High signal on Shutdown + indicates the motor winding current should be off. Signal levels: Low ≤ 1.0 VDC @ -30 mA, High ≥ 3.5 VDC @ +30 mA.
12
Shutdown – OUT
Differential output. This signal is used to turn off current in the motor windings. Low signal on Shutdown – indicates the motor winding current should be off.
13
ISO GND
-----
Isolated logic ground.
* Pin 3-4, 6-8, and 15 are reserved for connection to a ±10V analog servo drive (see page 10). ** The VINref, CNTRL-P, and GND terminals are located on the screw-terminal connector on top of the 6K chassis.
CONNECTIONS TO THE ARIES SERIES DRIVE Aries Drive Connections
18
Signal Name
Connector
Pin
GND
Drive/I/O
2
Enc outA+
Drive/I/O
3
Enc outA-
Drive/I/O
4
Enc outB+
Drive/I/O
5
Enc out B-
Drive/I/O
6
Enc out Z+
Drive/I/O
7
Enc out Z-
Drive/I/O
8
ENABLE+
Drive/I/O
1
FAULT+
Drive/I/O
9
STEP+
Drive/I/O
10
STEP-
Drive/I/O
11
DIRECTION+
Drive/I/O
12
DIRECTION-
Drive/I/O
13
FAULT-
Drive/I/O
16
6K Hardware Installation Guide
6K Connections Signal Name Connector
Pin
↔ GND ↔ A+
Encoder
9
Encoder
2
↔ A↔ B+
Encoder
3
Encoder
4
↔ B↔ Z+
Encoder
5
Encoder
6
↔ ZEncoder ↔ SHUTDOWN- Drive
12
↔ DRF ↔ STEP+
Drive
5
Drive
1
↔ STEPDrive ↔ DIRECTION+ Drive
9
↔ Direction↔ GND
Drive
10
Drive
13
7
2
Page 25
CONNECTIONS TO THE COMPAX3 DRIVE Compax3 Drive Connections Signal Name Step+ (5V)
Connector x11
Pin 7
6K Connections
Step- (5V)
x11
6
Signal Name Connector Drive ↔ STEP+ ↔ STEPDrive
Dir + (5V)
x11
8
DIRECTION- Drive
10
Dir - (5V)
x11
12
↔ DIRECTION+ Drive
2
Output 0 Jumper pins 6 & 8. GND 24 V x12
2
↔ DFT
Drive
5 x12
15
↔ GND
Drive
13
Input 0 x12
6
↔ COM
Drive
14
Input 1 x12
7
↔ SHTNO
Drive
7
Input 2 x12
8
24 V+ Out x12
1
24V In for Outputs x12
11
Pin 1 9
Jumper pins 1, 7, & 11. CONNECTIONS TO THE DYNASERV DRIVE 6K Connections
Dynaserv Drive Connections Signal Name
Connector
Pin
Step +
DN1
45
Step –
DN1
46
Direction +
DN1
20
Direction –
DN1
19
Servo On –
DN1
23
Servo On +
DN1
24
Servo Ready +
DN1
15
Servo Ready –
DN1
16
A+
DN1
13
A–
DN1
14
B+
DN1
29
B–
DN1
30
Z+
DN1
43
Z–
DN1
44
Signal Name Connector ↔ Step + ↔ Step – ↔ Direction + ↔ Direction –
Pin
Drive
1
Drive
9
Drive
2
Drive
10
↔ Shutdown + ↔ Shutdown –
Drive
11
Drive
12
↔ Drive Fault ↔ Ground
Drive
5
Drive
13
↔ A+ ↔ A–
Encoder
2
Encoder
3
↔ B+ ↔ B–
Encoder
4
Encoder
5
↔ Z+ ↔ Z–
Encoder
6
Encoder
7
NOTE: These connections assume that the Dynaserv is left in its factory default setting for Position Mode (for accepting step and direction command signals). Refer to your Dynaserv user guide for verification.
Chapter 1. Installation
19
Page 26
CONNECTIONS TO THE DYNASERV GE DRIVE Dynaserv GE Drive Connections Signal Name
Connector
Pin
ACMD IN+
CN4
35
ACMD IN-
6K Connections Signal Name Connector
Pin
↔
CMD+
Drive
3
CN4
36
↔
CMD-
Drive
6
DRV RDY OUT CN4
4
↔
DFT
Drive
5
COMPN1
CN4
2
↔
GND
Drive
13
COMPN1
CN4
2
↔
COM
Drive
14
SERVO ON IN
CN4
20
↔
SHTNO
Drive
7
COMP1
CN4
1
↔
5 VOLTS+
Encoder
1
UA OUT+
CN4
9
↔
A+
Encoder
2
UA OUT-
CN4
10
↔
A-
Encoder
3
DB OUT+
CN4
11
↔
B+
Encoder
4
DB OUT-
CN4
12
↔
B-
Encoder
5
Z OUT+
CN4
13
↔
Z+
Encoder
6
Z OUT-
CN4
14
↔
Z-
Encoder
7
COMPN1
CN4
2
↔
GND
Encoder
9
CONNECTIONS TO THE EAC, EDC, OEM750, S, PDS, and ZETA DRIVES Drive Connections
6K Connections
Signal Name
Connector Pin
Step +
25-pin
1
↔
Signal Name Connector Step +
Drive
Pin 1
Step –
25-pin
14
↔
Step –
Drive
9
Direction +
25-pin
2
↔
Direction +
Drive
2
Direction –
25-pin
15
↔
Direction –
Drive
10
Shutdown +
25-pin
16
↔
Shutdown +
Drive
11
Shutdown –
25-pin
17
↔
Shutdown –
Drive
12
Fault Output
25-pin
9
↔
Drive Fault
Drive
5
Fault Return
25-pin
21
↔
Ground
Drive
13
NOTES
• The PDS drive requires a PULSE command setting of 1.0 (PULSE1.0). • Use the 10-foot cable (p/n 71-016137-10) for plug compatibility.
20
6K Hardware Installation Guide
Jumper pins 13 & 14.
Page 27
CONNECTIONS TO THE LINEARSERV DRIVE 6K Connections
Linearserv Drive Connections Signal Name
Connector
Pin
Step +
CN1
15
Step –
CN1
39
Direction +
CN1
13
Direction –
CN1
37
Servo On –
CN1
5
Servo On +
CN1
1
Servo Ready +
CN1
31
Servo Ready –
CN1
26
A+
CN1
17
A–
CN1
41
B+
CN1
19
B–
CN1
43
Z+
CN1
21
Z–
CN1
45
Signal Name Connector ↔ Step + ↔ Step – ↔ Direction + ↔ Direction – ↔ Ground ↔ Shutdown –
Pin
Drive
1
Drive
9
Drive
2
Drive
10
Drive
13
Drive
12
↔ Drive Fault ↔ Ground
Drive
5
Drive
13
↔ A+ ↔ A–
Encoder
2
Encoder
3
↔ B+ ↔ B–
Encoder
4
Encoder
5
↔ Z+ ↔ Z–
Encoder
6
Encoder
7
NOTE: These connections assume that the Linearserv is left in its factory default setting for Position Mode (for accepting step and direction command signals). Refer to your Linearserv user guide for verification. CONNECTIONS TO THE OEM670SD DRIVE 6K Connections
OEM670SD Connections Signal Name
Connector
Pin
Step +
25-pin
3
↔ Step +
Drive
1
↔ Step – ↔ Direction +
Drive
9
Drive
2
↔ Direction – ↔ Shutdown +
Drive
10
Drive
11
Drive
12
Drive
5
Drive
13
Step –
25-pin
14
Direction +
25-pin
4
Direction –
25-pin
15
Signal Name Connector
Shutdown +
25-pin
12
Shutdown –
25-pin
13
ISO Fault +
25-pin
22
↔ Shutdown – ↔ Drive Fault
Fault Return
25-pin
23
↔ Ground
Pin
CONNECTIONS TO THE PKH130M DRIVE 6K Connections
PKH130 Drive Connections Signal Name
Pin
Clock
6
Direction
5
Fault
2
Reset 0V
Signal Name Connector ↔ Step – ↔ Direction +
9
Drive
2
Drive
5
7
↔ Drive Fault ↔ Shutdown –
Drive
12
8
↔ Ground
Drive
13
NOTE: The PKH130M drive requires a PULSE setting of PULSE8.0.
Chapter 1. Installation
21
Pin
Drive
Page 28
CONNECTIONS TO THE VIX DRIVE Vix Drive Connections
22
6K Connections
Signal Name
Connector
Pin
Signal Name Connector
0V
X4
3
Pin
↔
COM
14
ENABLE
X4
ENC. A+ IN
X4
11
↔
GND
Drive
13
12
↔
SHTNO
Drive
7
ENC. A- IN ENC. B- IN
X4
7
↔
STEP+
Drive
1
X4
8
↔
STEP-
Drive
9
ENC.B+ IN
X4
13
↔
DIRECTION- Drive
10
FAULT OUTPUT
X4
6
↔
DIRECTION+ Drive
2
ENC. A+ OUT
X4
14
↔
DRF
Drive
5
ENC. A- OUT
X4
9
↔
A+
Encoder
2
ENC. B+ OUT
X4
15
↔
A-
Encoder
3
ENC. B- OUT
X4
10
↔
B+
Encoder
4
ENC. Z+ OUT
X4
5
↔
B-
Encoder
5
6K Hardware Installation Guide
Drive
Page 29
Encoders
(“ENCODERS” and “MASTER ENCODER” connectors) ENCODER INPUTS: Differential comparator accepts two-phase quadrature incremental encoders with differential (recommended) or single-ended outputs. Max. frequency is 12.0 MHz post quadrature. TTL-compatible voltage levels: Low ≤ 0.4V, High ≥ 2.4V. Maximum input voltage is 5 VDC. MASTER ENCODER: The master encoder is used for Following, and not for servo feedback or stepper stall detect. The pin outs are the same as the other encoders, except that pin 8 is ISO GND (can’t use a single-ended encoder).
NOTE: When connecting a –HJ single-ended encoder to the 6K, be sure to connect the encoder’s white lead (channel A+) to pin #2 (A+). The current Installation Guide incorrectly shows the white lead connected to
Chapter 1. Installation
23
Page 30
Limit Inputs
(“LIMITS/HOME” connectors)
NOTES • Motion will not occur on an axis until you do one of the following: - Install end-of-travel limit switches - Disable end-of-travel limits with the LHØ command (only if load not coupled) - Change the active level of the limits with the LIMLVL command. • End-of-travel input functionality: Mount each switch such that the load forces it to open before it reaches the physical travel limit (leave enough room for the load to stop). When the load opens the switch, the axis stops at the LHAD deceleration. The motor will not be able to move in that same direction until you execute a move in the opposite direction and clear the limit by closing the switch. • Home input functionality: After initiating a homing move with the HOM command, the 6K waits for the home input switch to close, indicating the load has reached the desired “home” reference position. • Refer to the Basic Operation Setup chapter in the 6K Series Programmer’s Guide for in-depth discussions about using end-of-travel limits and homing. • See page 41 for connections to the “VM25” screw-terminal converter (sold separately).
For easy screw-terminal connections, use the “VM25” screw-terminal converter (sold separately, includes 2-foot cable). Connection instructions are provided on page 41. PIN OUTS & SPECIFICATIONS Pin # 25 23 21 19 17 15 13 11 9 7 5 3 1
In/Out ----IN IN IN IN IN IN IN IN IN IN IN IN
Axes 1-4 ----1POS 1NEG 1HOME 2POS 2NEG 2HOME 3POS* 3NEG* 3HOME* 4POS* 4NEG* 4HOME*
Axes 5-8 ----5POS 5NEG 5HOME 6POS 6NEG 6HOME 7POS * 7NEG * 7HOME * 8POS * 8NEG * 8HOME *
Description (input functions programmed by LIMFNC) RESERVED Positive direction end-of-travel limit, axis 1 or 5. Negative direction end-of-travel limit, axis 1 or 5. Home limit, axis 1 or 5. Positive direction end-of-travel limit, axis 2 or 6. Negative direction end-of-travel limit, axis 2 or 6. Home limit, axis 2 or 6. Positive direction end-of-travel limit for axis 3 or 7. Negative direction end-of-travel limit for axis 3 or 7. Home limit, or general purpose input for axis 3 or 7. Positive direction end-of-travel limit for axis 4 or 8. Negative direction end-of-travel limit for axis 4 or 8. Home limit for axis 4 or 8.
All even number pins are connected to isolated logic ground. * On 6K2 and 6K6 products, these pins function as general-purpose inputs (function is set with the LIMFNCi-A command). ** The VINref, LIM-P, and GND terminals are located on the screw-terminal connector on top of the 6K chassis.
24
6K Hardware Installation Guide
Specification for limit inputs • Voltage range is 0-24 VDC. • Switching levels: Low ≤ 1/3 VINref voltage, High ≥ 2/3 VINref voltage (factory default VINref voltage is +24 VDC, but you can connect a different voltage to the VINref terminal**). To make all limit inputs sinking inputs, connect the LIM-P terminal** to the GND terminal**. • Status: Check with TLIM or LIM. • Active level is set with the LIMLVL command. Default is active low: end-of-travel limits which require a n.c. switch and home limits which require a n.o. switch.