Page 51
Appendix B. EVM32 Installation Connect to the 6K’s “EXPANSION I/O” connector (use the provided cable).
EVM32 Brick #1 st (1 unit in serial chain)
EVM32 Brick #2 nd (2 unit in serial chain)
2-foot (0.61 m) cable is provided with the baseboard (EVM32-BASE). SIM boards are ordered separately from the baseboard.
Baseboard (EVM32-BASE).
g
EVM32 Description The EVM32-Base and EVM32-ll is a family of I/O modules (or “bricks”) that is sold as accessories to the 6K Controllers. The EVM32 provides additional I/O for 6K controller. Up to eight DIN-rail mountable EVM32 bricks can be connected in a serial chain to the 6K. Each EVM32 brick can hold from 1 to 4 of the I/O SIM boards in any combination (each SIM board provides 8 I/O points, for a total of 32 I/O points per I/O brick): • Digital inputs • Digital outputs • Analog inputs Order an EVM32 brick and up to four I/O SIM boards per brick (see table below): Product (p/n)
Description
EVM32-Base EVM32-ll SIM8-IN-EVM32 SIM8-OUT-NPN SIM8-OUT-PNP SIM8-OUT-SSR SIM8-OUT-HCR SIM8-AN-IN SIM8-AN-OUT SIM8-IN SIM8-OUT-EVM32 71-016949-02 71-016949-100
EVM32 baseboard, extrusion with built-in DIN rail mount (includes 2-foot cable). EVM32 baseboard, extrusion with built-in DIN rail mount (includes 2-foot cable). Digital input SIM board (8 inputs). Color code: RED Digital output SIM board (8 outputs), sinking. Color code: BLUE Digital output SIM board (8 outputs), sourcing. Color code: BLUE Solid State Relay SIM board (8 outputs). Color code: BLUE High Current Relay SIM board (8 outputs). Color code: BLUE Analog (+/- 10V) input SIM board (8 inputs). Color code: GREEN Analog (+/- 10V) output SIM board (8 outputs). Color code: BLACK SIM board with 8 digital inputs. Color code: RED SIM board with 8 digital outputs. Color code: BLUE 2-foot cable for connection to 6K or between I/O bricks (included with EVM32-BASE) 100-foot cable for connection to 6K or between I/O bricks
Page 52
EVM32 Specifications Parameter
Specification
Power (DC input) V+ ....................................................................... User-supplied voltage that drives output circuitry. V+ range ............................................................. 12-24 VDC. (If using SIM8-AN-OUT, you must use a 24 VDC supply.) V+ current ........................................................... 1.8A @ 12 VDC or 0.9A @ 24 VDC; plus the sum of the load current on the PNP outputs. Environmental Operating temperature........................................ 32 to 122°F (0 to 50°C) Storage temperature........................................... -22 to 185°F (-30 to 85°C) Humidity.............................................................. 0 to 95% non-condensing Dimensions (see dimension drawing on page 48). Digital Inputs (SIM8-IN-EVM32)Inputs are not optically isolated. Switching levels .................................................. Low ≤ 1/3 V+ voltage; High ≥ 2/3 V+ voltage. Voltage range ..................................................... Voltage range = 0-24 VDC. Voltage of input signals should not exceed voltage level of V+. (Input circuitry of EVM32 has diodes to protect against voltages that exceed V+, but performance may degrade.) Sinking/Sourcing................................................. Sinking: Connect jumper for selected SIM board to position 1. Sourcing: Connect jumper for selected SIM board to position 3 (factory default). Impedance .......................................................... 6 KΩ, minimum. Requires input current (sinking or sourcing) of 0.111 mA per volt of user-supplied voltage to V+ (e.g., 2.67 mA if V+ = 24V). Active level.......................................................... Set by the 6K controller (INLVL command setting), default is active low, but can be set to active high. Input frequency ................................................... 50 kHz (the maximum frequency is limited practically to 500 Hz by the 2 ms update rate of the 6K controller). Status.................................................................. Check with the TIO command. LED illuminates when at least [2/3 * V+] volts is present on the input: If sinking (jumper in position 1), the default LED state is off. The LED illuminates when the voltage at the input is at least [2/3 * V+] volts. If sourcing (jumper in position 3), the default LED state is on. The LED goes off when the voltage at the input is below [1/3 * V+] volts. Reed Relay Outputs (SIM8-OUT-RLY10), OBSOLETE (replaced by SIM8-OUT-SSR and SIM8-OUT-HCR) Current rating...................................................... Maximum of 10 Watts. Switching voltage to 200 VDC or 200 VAC peak resistive Switching current to 0.5A Operate time, including bounce – typical............ 0.4 milliseconds Release time – typical......................................... 0.1 milliseconds Capacitance – typical.......................................... 0.7 pF Status.................................................................. Check with the TIO command. LED is on when the relay contact is closed. Digital Outputs (SIM8-OUT-NPN and SIM8-OUT-PNP) Sinking/Sourcing................................................. SIM8-OUT-NPN provides 8 sinking outputs. SIM8-OUT-PNP provides 8 sourcing outputs. Voltage (sinking, SIM8-OUT-NPN) ................. Output voltage level is less than or equal to 0.4 VDC when sinking up to 50 mA. (≤ 0.4 VDC for 50 mA). Output voltage level is less than or equal to 2.5 VDC when sinking up to 300 mA. (≤ 2.5 VDC for 300 mA). Voltage (sourcing, SIM8-OUT-PNP) ............... Output voltage level may be up to 2 volts less than the user-supplied voltage V+ when sourcing up to 50 mA. Output voltage level may be up to 2.5 volts less than the user-supplied voltage V+ when sourcing up to 300 mA. Current................................................................ 300 mA maximum per output; continuous duty at 50°C ambient temperature. NOTE: For PNP outputs, the actual current is subject to derating, based on load current, duty cycle, and number of simultaneously active outputs (see graph below). Improved performance may be achieved by lowering the ambient temperature and/or staggering the physical order of the outputs that are simultaneously active (for details, refer to page __).
46
6K Hardware Installation Guide
Page 53
mA Graph data is applicable to an EVM32 (cover installed) with PNP SIMs at 50 degrees C.
350 Operation above 300mA is not recommended. 300
Load Current (mA)
300 250
240
Limit to Number of Simultaneously Active Outputs Contiguous * Alternately Staggered * up to 2 up to 10 up to 8 up to 16 up to 32 up to 32
200 150 100
180
* "Contiguous" means sequentially numbered I/O points on the EVM32 (for example: 1, 2, 3, 4, 5, 6, 7, 8, 9 ... ). "Alternately Staggered" means alternate even or odd numbered I/O points (for example: 1, 3, 5, 7, 9, 11, 13, 15 ... or 2, 4, 6, 8, 10, 12, 14 ... )
50 0 0
10
20
30
40
50
60
70
80
90
100
% Duty Cycle
Active level ......................................................... Set with the OUTLVL command. On power-up or reconnect, SIM8-OUT-NPN is set to active low (OUTLVL0), and SIM8-OUT-PNP is set to active high (OUTLVL1). Thermal shutdown .............................................. Thermal shutdown protects the drive devices from excessive heat. The NPN SIM has 2 drive devices (4 output channels per device); the PNP SIM has 4 drive devices (2 output channels per device). When a drive device reaches 165°C, it will shut down (PNP: shut down two output channels; NPN: shut down four channels). The device driver will again become active when its temperature cools to 150°C. Short-circuit protection........................................ Digital outputs are short-circuit protected. Short-circuit protection only shuts down the affected output channel. To recover, remove the fault and cycle power to the EVM32. Status.................................................................. Check with the TIO command. With default OUTLVL, LED is on when output is active (set to 1 with OUT command). Solid State Relay (SIM8-OUT-SSR) Voltage rating...................................................... Maximum of 130V AC/DC. Current rating...................................................... Maximum of 100 mA. Operate (On) time - Typical................................ 0.1 ms at 50 mA Load, 100V Release time - Typical........................................ 0.11 ms at 50 mA Load, 100V On-state resistance............................................. 24 Ohms (pulsed), 50 ma Load 10 Off-state resistance............................................. 10 Ohms Capacitance........................................................ 6 pF at 50V Status.................................................................. Check with the TIO command. LED is on when the relay is energized. Technology ......................................................... Power MOSFET Photovoltaic Relay, Single-Pole, Normally Open, Bounce-Free Operation. High Current Relay (SIM8-OUT-HCR) Operating voltage range ..................................... 0 to 60 VDC (or AC Peak). Voltage rating...................................................... Maximum of 130V AC/DC. Current rating...................................................... Maximum of 0.600 Amps. Operate (On) time - Typical................................ 0.2 ms at 500 mA Load, 50V Release time - Typical........................................ 0.5 ms at 500 mA Load, 50V On-state resistance............................................. 500 mOhms 8 Off-state resistance............................................. 10 Ohms Capacitance........................................................ 150 pF at 50V Status.................................................................. Check with the TIO command. LED is on when the relay is energized. Technology ......................................................... Power MOSFET Photovoltaic Relay, Single-Pole, Normally Open, Bounce-Free Operation. Analog Inputs (SIM8-AN-IN) Input voltage range ............................................. 12-bit A/D converter, ±10 VDC; unipolar/bipolar range selectable ANIRNG command. Unipolar: 0V to 10 VDC, or 0V to 5V; Bipolar: -10 to +10V (factory default), or -5V to +5V. Input current (worst case load) ........................... Unipolar: 720µA @ 0V to 10 VDC range; 360µA @ 0V to 5V range. Bipolar: -1200µA @ -10V and 720µA @ +10V; -600µA @ -5V and 360µA @ +5V. Input dynamic resistance .................................... Unipolar: 21KΩ; Bipolar: 16KΩ Fault tolerance .................................................... ±16.5V Sample rate ........................................................ Each input requires 2ms (e.g., 4 ms for 2 inputs, 16ms for 8 inputs); therefore, to maximize performance, you should disable unused inputs with ANIEN command. Status.................................................................. Check with the TIO command. Analog Outputs (SIM8-AN-OUT) Output voltage range .......................................... 10-bit DAC, ±10 VDC, 8 channels total. Load.................................................................... 2KΩ resistive at 5 mA maximum. Linearity error...................................................... 0.66% (typical), 1.3% maximum, over the ±10 VDC range. Status.................................................................. Check with the TIO command or the TANO command.
Appendix B. EVM32 Installation
47
Page 54
Page 55
EVM32-ll Dimensions
<4 6.33 >
(160,8)
© (Cees) O
1 i
(_compumotor reextcr) ) Cans OO O O OO Oe C7
Cures OO OO OO OO) <= CC
4.33 (109,9)
4.72 (120)
+ Vs Ve Ve We Ve We Volvo Ve Ve Ve Ve Ve Ve Volvo Ve Ve We Ve Ve Vo Valve Vo Ve We Ve Ve Ve Vell vy yy
12.3 45 6 7 8/9 1082131 4151Gt7 181 92021222324252627282930313, WEE ae
2.21 (56)
Appendix B. EVM32 Installation 49
4.00 (103)
[olelelelelejelele) [olelelelelejelele) OOOOOOOOO
~<a 230 _» (58.4)
Page 56
Installing the SIM Boards Step 1: Remove the Cover Caution, EVM32 SIM boards are static sensitive. Observe proper ESD handling precautions. Remove power to the EVM32 baseboard before installing or removing the SIM boards.
Step 2: Install the SIM boards 3
2
SIM #2 (I/O points 9-16) Snap into place
1
SIM #1 (I/O points 1-8) SIM #3 (I/O points 17-24) SIM #4 (I/O points 25-32)
Notch
Notch
SIM Slot
50
6K Hardware Installation Guide
Page 57
Step 3: (SIM8-IN-EVM32 only) Set the jumpers to select sinking or sourcing %&
%#
%
-
Step 4: Replace the cover and label the SIM locations SIM Board
Color
Label
SIM8-IN-EVM32 (digital inputs)
Red
8 IN
SIM8-OUT-NPN (digital outputs, sinking)
Blue
8 OUT (NPN)
SIM8-OUT-PNP (digital outputs, sourcing)
Blue
8 OUT (PNP)
SIM8-OUT-RLY10 (reed relay outputs)
Blue
RELAY
SIM8-OUT-SSR (Solid State Relay)
Blue
RELAY
SIM8-OUT-HCR (High Current Relay)
Blue
RELAY
SIM8-AN-IN (analog inputs)
Green
ANALOG IN
SIM8-AN-OUT (analog outputs)
Black
ANALOG OUT
Appendix B. EVM32 Installation
51
Page 58
Electrical Connections Caution, Remove power to the 6K controller and the EMV32 baseboard before: Installing or removing SIM boards on the EVM32 baseboard Connecting or disconnecting the EVM32 baseboard to the 6K controller or to other EVM32 units. Connecting inputs and outputs to the EVM32.
Connecting the 6K controller and EVM32 I/O bricks If the EVM32 I/O brick is disconnected (or if it loses power), the 6K will perform a kill (all motion and program execution on all tasks) and set error bit #18 (reported with the TER, TERF and ER commands). The 6K will remember the brick configuration (volatile memory) in effect at the time the disconnection occurred. When you reconnect the I/O brick, the controller checks to see if anything changed (SIM by SIM) from the state when it was disconnected. If an existing SIM slot is changed (different SIM, vacant SIM slot, or jumper setting), the controller will set the digital input SIMs and digital output SIMs to factory default INEN and OUTLVL settings, respectively. If a new SIM is installed where there was none before, the new SIM is auto-configured to factory defaults. When the 6K powers up and detects a digital output SIM on a EVM32, it will set the active level (OUTLVL command) according to the type of SIM. OUTLVL0, active low, is selected for NPN SIMs; OUTLVL1, active high, is selected for PNP SIMs.
Connect to the 6K’s “EXPANSION I/O” connector (use the provided cable).
EVM32 Brick #1 st (1 unit in serial chain)
2-foot (0.61 m) cable is provided with the baseboard (EVM32-BASE).
To check the status of one or more EVM32 I/O bricks, use the TIO command.
52
6K Hardware Installation Guide
Page 59
Jumpers The EVM32-1l includes jumpers for terminating the DATA and ATTN lines on the last I/O brick in a chain. The following equivalent diagram applies to JU5 and JU6.
24 VDC power input
Appendix B. EVM32 Installation
53
Page 60
Reed Relay Outputs (SIM8-OUT-RLY10) External Supply (12 to 24VDC)
+
EVM32
V+
Electronic Device
J1 GND Iso GND
Output Connection
N.O. LED
Return (Use the GND pin for the corresponding output pin. When using the Relay SIM, the GND terminals are not internally connected together.)
54
6K Hardware Installation Guide
Input