Page 41

What’s Next? By now, you should have completed the following tasks, as instructed earlier in this chapter: 1. Check the ship kit to make sure that you have all the items (see page 3). 2. Review the general specifications table (see page 4). 3. (optional) Set internal DIP switches for using the “RS-232/485” connector as an RS-485 serial port (default function is RS-232 and configured for connection to an RP240). 4. Mount the 6K controller (see page 6). 5. Connect all electrical system components (see pages 8-33). Installation instructions for the EVM32 expansion I/O are provided on page 45. 6. Test the installation (see page 34).

Next… 1. Mount the motors and/or couple the loads. 2. Tune any servo axes or axes using the ZETA drive. Use the tuning facility in Motion Planner (see page 59).

And Finally… After completing all necessary hardware installation tasks, you are ready to program your motion control functions. Knowing your system’s motion control requirements, refer now to the 6K Series Programmer’s Guide for descriptions of the 6K’s software features and instructions on how to implement them in your application. Be sure to keep the 6K Series Command Reference at hand as a reference for the 6K Series command descriptions. For assistance with your programming effort, we recommend that you use the programming tools provided in Motion Planner for Windows (found in your ship kit).

Chapter 1. Installation

35

Page 42

CHAPTER TWO

Troubleshooting

Chapter 2. Troubleshooting IN THIS CHAPTER

Troubleshooting basics................................................................................ 37 Solutions to common problems ................................................................... 38 Resolving RS-232 & RS-485 communication problems.............................. 42 Product return procedure............................................................................. 43

Page 43

Troubleshooting Basics When your system does not function properly (or as you expect it to operate), the first thing that you must do is identify and isolate the problem. When you have accomplished this, you can effectively begin to resolve the problem. The first step is to isolate each system component and ensure that each component functions properly when it is run independently. You may have to dismantle your system and put it back together piece by piece to detect the problem. If you have additional units available, you may want to exchange them with existing components in your system to help identify the source of the problem. Determine if the problem is mechanical, electrical, or software-related. Can you repeat or re-create the problem? Random events may appear to be related, but they are not necessarily contributing factors to your problem. You may be experiencing more than one problem. You must isolate and solve one problem at a time. Log (document) all testing and problem isolation procedures. You may need to review and consult these notes later. This will also prevent you from duplicating your testing efforts. Once you isolate the problem, refer to the problem solutions contained in this chapter. If the problem persists, contact your local technical support resource (see Technical Support below).

Technical Support If you cannot solve your system problems using this documentation, contact your local Automation Technology Center (ATC) or distributor for assistance. If you need to talk to our in-house application engineers, please contact us at the numbers listed on the inside cover of this manual.

Chapter 2. Troubleshooting

37

Page 44

Solutions to Common Problems Note: Some software-related causes are provided because it is sometimes difficult to identify a problem as either hardware or software related. Problem

Cause

Solution

Communication

1. Ethernet card not installed

1. Refer to the user instructions that came with your Ethernet card.

(Ethernet) errors.

correctly. 2. Ethernet or IP address conflict.

2. Refer to the configuration instructions in the 6K Programmer’s Guide.

3. Connection to Ethernet port is

3. Check the connections according to page 28.

compromised or mis-wired. Communication (serial)

1. Improper interface connections or not operative, or receive communication protocol.

1. Check the connections according to page 28.

garbled characters. NOTE: Refer also to the

2. COM port disabled.

diagnostic procedures on

2.a. Enable serial communication with the E1 command. 2.b. If using RS-485, make sure the internal jumpers are set page 42.

accordingly (see page 5). Make sure COM 2 port is enabled for sending 6K language commands (execute the PORT2 and DRPCHKØ commands). 3. In daisy chain, unit may not be set

3. Verify proper application of the ADDR command.

to proper address. Direction is reversed.

1. Direction connections to the drive

(stepper axes only)

are reversed.

1. Switch DIR+ with DIR- connection to drive (see page 17).

2. Phase of step motor reversed

2. Switch A+ with A- connection from drive to motor.

(motor does not move in the

SOFTWARE ALTERNATIVE: If the motor (and the encoder if one is used) is reversed, use the CMDDIR1 command to reverse the commanded direction).

polarity of both the commanded direction and the polarity of the encoder counts). 3. Phase of encoder reversed (reported TPE direction is reversed).

3. Swap the A+ and A– connection at the ENCODER connector.

Direction is reversed,

1. Command output (CMD)

1. Software remedy: Issue the CMDDIR1 command to the affected servo condition is stable.

connections and feedback device axis. This reverses the polarity of the commanded direction and the

(servo axes only)

connections or mounting are feedback direction so that servo stability is maintained.

reversed.

Hardware remedy: Switch CMD- with the CMD+ connection to drive or valve (if your drive or valve does not accept differential outputs this will not work). You will also have to change the feedback device wiring or mounting so that it counts in same direction as the commanded direction.

Direction is reversed,

1. Not tuned properly.

1. Refer to tuning instructions on page 59.

2. Phase of encoder reversed or mounting of ANI input is such that it

2. Software remedy for encoder feedback only: For the affected axis, issue ENCPOL1.

counts in the opposite direction as the

Hardware remedy: If using encoder feedback, swap the A+ and A-servo condition is unstable. (servo axes only)

commanded direction.

connections to the 6K product. If using ANI feedback, change the mounting so that the counting direction is reversed.

38

6K Hardware Installation Guide

Page 45

Problem

Cause

Solution

Distance, velocity, and

1. Incorrect resolution setting.

accel are incorrect as

1.a. Stepper axes: Set the resolution on the to match the 6K product’s DRES command setting (default DRES setting is 25,000 programmed.

steps/rev). 1.b. Match the 6K product's ERES command setting (default ERES setting is 4,000 counts/rev) to match the post-quadrature resolution of the encoder. ERES values for Parker Hannifin encoders: Stepper axes: RE, -RC, -EC, & -E Series Encoders: ................. ERES4000 HJ Series Encoders: ........................................... ERES2048 Servo axes (SM, N or J Series Servo Motors): SM/N/JxxxxD-xxxx: ............................................. ERES2000 SM/N/JxxxxE-xxxx: ............................................. ERES4000 Dynaserv (stepper and servo): DR10xxB............................................................. ERES507904 DR1xxxE ............................................................. ERES614400 DR1xxxA ............................................................. ERES819200 DR5xxxB ............................................................. ERES278528 DR5xxxA ............................................................. ERES425894 DM10xxB ............................................................ ERES655360 DM1xxxA............................................................. ERES1024000 DM1004x............................................................. ERES655360 2. Pulse width too narrow.

2. Set pulse width to drive specifications using the PULSE command.

(stepper axes) 3. Wrong scaling values.

3. Check the scaling parameters (SCALE1, SCLA, SCLD, SCLV, SCLMAS).

Erratic operation.

Feedback device

1. Electrical Noise.

1. Reduce electrical noise or move product away from noise source.

2. Improper shielding.

2. Shield for noise immunity.

3. Improper wiring.

3. Check wiring for opens, shorts, & mis-wired connections.

1. Improper wiring.

1. Check wiring.

2. Feedback device slipping.

2. Check and tighten feedback device coupling.

3. Encoder too hot.

3. Reduce encoder temperature with heatsink, thermal insulator, etc.

4. Electrical noise.

4a. Shield wiring.

(encoder or ANI) counts missing.

4b. Use encoder with differential outputs. 5. Encoder frequency too high.

5. Peak encoder frequency must be below 12.0 MHz postquadrature. Peak frequency must account for velocity ripple.

Joystick mode:

1. Joystick Release input not

Motor does not move.

grounded.

1.a. If an input is not assigned the “Joystick Release” input function, do so with the INFNCi-M command. 1.b. Ground the Joystick Release input.

2. Improper wiring.

Chapter 2. Troubleshooting

39

2. Check wiring for opens, shorts, and mis-wired connections.

Page 46

Problem

Cause

LEDs:

All other LED states indicate hardware

Solution conditions; refer to your product's Installation Guide for details. “POWER” LED is

1. No power.

1. Check 24 VDC power connection and restore power.

“POWER” LED is

1. General fault.

red.

2. ENABLE input not grounded.

1. Reset the controller by one of these methods: • Cycle power • Issue the RESET command off.

2. Ground the ENABLE input. An “AXIS” LED is on (red).

1. Drive was commanded to shut down (DRIVE0). If Disable Drive on Kill mode is enabled (KDRIVE1), a kill command or kill input will also disabled the drive.

1. Re-enable the drive by sending a DRIVE1 command to the affected axis. 2. (verify position error by checking to see if TAS/TASF bit #23 is set) Check feedback device connection and mounting and re-enable drive by sending DRIVE1 command to the affected axis.

2. Servo Axes: Maximum position error (SMPER value) exceeded. Could be caused by disconnected or mismounted feedback device. Motion does not occur.

1. “AXIS” LED is red, or “POWER”

1. See LED troubleshooting as noted above.

LED is off or red. 2. End-of-travel limits are active.

2.a. Move load off of limits or disable limits by sending the LHØ command to the affected axis. 2.b. Software limits: Set LSPOS to a value greater than LSNEG.

3. Step pulse too narrow for drive to

3. Set pulse width to drive specifications using the PULSE command.

recognize (stepper axes only). 4. Drive fault level incorrect. 5. Improper wiring.

4. Set drive fault level using the DRFLVL command. 5. Check drive fault & limit connections. Stepper Axes: check step and direction connections. Servo Axes: check command and shutdown connections.

Power-up Program does

6. ENABLE input is not grounded.

6. Ground the ENABLE input connection.

7. Load is jammed.

7. Remove power and clear jam.

8. No torque from motor.

8. See problem: Torque, loss of.

9. Max. position error (SMPER value)

9. Check to see if TAS/TASF bit #23 is set, and issue the DRIVE1 exceeded. (servo axes only)

command to the axis that exceeded the position error limit.

10. Drive has activated the drive fault

10. Check to see if TAS/TASF bit #14 is set, and check the drive fault input.

level (DRFLVL).

1. ENABLE input is not grounded.

1. Ground the ENABLE input to GND and reset the product.

not execute.

(see page 9) 2. STARTP program is not defined.

2. Check the response to the STARTP command. If no program is reported, define the STARTP program and reset (refer to the STARTP command description).

40

6K Hardware Installation Guide

Page 47

Problem

Cause

Solution

Runaway

1. Direction connections reversed.

1. Switch CMD– with the CMD+ connection to drive or valve.

(SERVOS ONLY)

(if encoder counts positive when

NOTE:

turned clockwise or extended). Torque, loss of.

The CMD+/– Connection is not differential. Do not connect

CMD+ to ground on your drive.

1. Improper wiring.

1. Check wiring to the drive, as well as other system wiring.

2. No power to drive .

2. Check power to drive.

3. Drive failed.

3. Check drive status.

4. Drive faulted.

4. Check drive status.

5. Shutdown issued to drive.

5. Re-enable drive by sending the DRIVE1 command to the affected axis.

Chapter 2. Troubleshooting

41

Page 48 read from a scan by OCR; it may hold reading errors

Resolving Serial Communication Problems

General Notes Power up your computer or terminal BEFORE you power up the 6K. Make sure the serial interface is connected as instructed on page 28. Shield the cable to earth ground at one end only. The maximum RS-232 cable length is 50 feet (15.25 meters). RS-232: Handshaking must be disabled. Most software packages allow you to do this. You can also disable handshaking by jumpering some terminals on the computer’s/ terminal’s serial port: connect RTS to CTS (usually pins 4 and 5) and connect DSR to DTR (usually pins 6 and 20). RS-485: Make sure the internal DIP switches are configured as instructed on page 5.

Power up the computer or terminal and launch the terminal emulator.

Power up the 6K. A power-up message should be displayed, followed by a prompt (>).

Type “TREV” and press the ENTER key. (The TREV command reports the software revision.) The screen should now look as follows (if not, see Problem/Remedy table below).

*PARKER HANNIFIN 6K MOTION CONTROLLER

Test the Interface

ON>

>TREV *TREV92-016740-01-5.0 6K

Problem Remedy (based on the possible causes)

No Response COM port not enabled for 6000 language communication. If RS-232 connected to “RS-232” connector : issue “PORT1” and “DRPCHK9” commands. If RS-232 connected to “RS-232/485” connector: issue “PORT2” and “DRPCHK9” commands. If RS-485 connected to “RS-232/485” connector: issue “PORT2” and “DRPCHK” commands. Serial communication may be disabled; enable with the E1 command. RS-232: Echo may be disabled; enable with the ECHO1 command. If you are using an RS-232 connection between the host computer and the master 6K connected to multiple 6Ks in an RS-485 multi-drop, make sure the master 6K has these settings executed in the order given (you should place these settings in your power-up STARTP program): PORT1 (select RS-232 port, COM1, for configuration) ECHO3 (echo to both COM ports) PORT2 (select RS-232/485 port, COM2, for configuration) ECHO2 (echo to the other COM port, COM1) Faulty wiring. See instructions on page 28. RS-485: verify internal DIP switch settings on page 5. Also check for shorts or opens. Is the cable or computer/terminal bad? Here’s a test: 1. Disconnect the serial cable from the 6K end only. 2. Connect the cable’s Rx and Tx lines together (this echoes the characters back to the host). 3. Issue the TREV command. If nothing happens, the cable or computer/terminal may be faulty. The controller may be executing a program. Issue the !K command or the <ctr L>K command to kill the program.

Garbled Characters Verify setup: 9600 baud (range is 9600-1200), 8 data bits, 1 stop bit, no parity; RS-232: Full duplex; RS- 485: Half duplex (verify internal DIP switch settings on page 5). RS-485: Transmission line not properly terminated. See page 5 for internal DIP switch settings. See page 28for connections and calculating termination resistors (if not using the internal resistors via internal DIP switches). Faulty wiring. See instructions on page 28. RS-485: verify internal DIP switch settings on page 5. Also check for shorts or opens.

Double Characters Your terminal emulator is set to half-duplex; set it to full-duplex.

42 6K Hardware Installation Guide

Page 49

Product Return Procedure Step 1

Obtain the serial number and the model number of the defective unit, and secure a purchase order number to cover repair costs in the event the unit is determined by the manufacturers to be out of warranty.

Step 2

Before you return the unit, have someone from your organization with a technical understanding of the 6K system and its application include answers to the following questions: • • • •

What is the extent of the failure/reason for return? How long did it operate? Did any other items fail at the same time? What was happening when the unit failed (e.g., installing the unit, cycling power, starting other equipment, etc.)? How was the product configured (in detail)? Which, if any, cables were modified and how? With what equipment is the unit interfaced? What was the application? What was the system environment (temperature, enclosure, spacing, contaminants, etc.)? What upgrades, if any, are required (hardware, software, user guide)?

• • • • • • Step 3

Call for return authorization. Refer to the Technical Assistance phone numbers provided on the inside front cover of this document. The support personnel will also provide shipping guidelines.

Chapter 2. Troubleshooting

43

Page 50

Appendix A. VM25 Installation The VM25 provides screw-terminal connections for the I/O on the 25-pin connectors, which are the “TRIGGERS/OUTPUTS” and “LIMITS/HOME” connectors. The VM25 comes with a 2-foot cable that provides easy connection between the VM25 and the 6K’s 25-pin connector. The VM25 is ordered separately (part number is “VM25”).