Page 61

Specification

AS-B849-016

Specification

AS-B853-016

Description Number of Points Operating Voltage

48 Vac / DC input 16 41 ... 53 Vac / 47 ... 63 Hz; 39 ... 58 Vdc 2 8

Description Number of Points Operating Voltage Number of Groups Inputs per Group Max. Input Voltage Continuous Surge 280 V for 10 ms ON Conditions w/Inp Z of 1 K max. OFF Conditions < 130 Vac w/Inp Z > 40 K < 150 Vac w/Inp Z > 80 K Wetting Current Max. Response Time OFF to ON ON to OFF Power Required +5 V +4.3 V 5V Dimensions Space Required Weight Terminal Connector

115 Vac 16 80 ... 130 Vac / 47 ... 63 Hz; 2 8

Number of Groups Inputs per Group Max. Input Voltage Continuous Surge ON Conditions OFF Conditions Wetting Current Max. Response Time OFF to ON ON to OFF Power Required +5 V +4.3 V 5V External Power Supply Dimensions Space Required Weight Terminal Connector

AS-B849-016 Terminal Numbering and Wire Connections

53 Vac / 58 Vdc 63 Vac / 70 Vdc for 10 sec 110 V for 10 ms > 41 Vac or 39 Vdc w/Inp Z of 1 K max. < 15 Vac / 20 Vdc < 53 Vac w/Inp Z > 25 K < 58 Vac w/Inp Z > 50 K 6.5 mA (typical) @ 48 Vdc 6 ms 18 ms 40 mA 1 mA 15 mA 48 Vac/DC, 200 mA 1 slot 2.75 lbs (1.25 kg) AS-8534-000

AS-B849-016 Mechanical Keying for Housings

AS-B853-016 Terminal Numbering and Wire Connections

130 Vac 150 Vac > 80 Vac < 35 Vac 6 mA (typical) @ 125 Vdc 6 ms 18 ms 40 mA 1 mA 15 mA 1 slot 2.75 lbs (1.25 kg) AS-8534-000

AS-B853-016 Mechanical Keying for Housings

TOP TOP

BOTTOM BOTTOM

(When facing housing, place pins in holes shown by black circles.)

3-62

(When facing housing, place pins in holes shown by black circles.)

Page 62

Specification Description Mode of Operation Number of Points Operating Voltage Number of Groups Inputs per Group Max. Input Voltage Continous Surge ON Conditions OFF Conditions Max. Response Time OFF to ON ON to OFF Power Required +5 V +4.3 V 5V External Power Supply Dimensions Space Required Weight Terminal Connector Agency

AS-B855-016 Terminal Numbering and Wire Connections

AS-B855-016

Specification

AS-B863-032

12 Vdc intrinsically safe input True Low 16 11.4 ... 12.6 Vdc 1 16

Description Type of Operation Number of Points Operating Voltage Number of Groups Inputs per Group Max. Input Voltage Continuous Surge ON Conditions OFF Conditions Wetting Current Max Response Time OFF to ON ON to OFF Power Required +5 V +4.3 V 5V External Power Supply Dimensions Space Required Weight Terminal Connector

24 Vdc hi-density monitored input True High 32 18 ... 30 Vdc 2 16

12 Vdc (± 5%) 500 Vdc for 3 ms ≤ 100 Ω total impedance >100,000 Ω; 0 Vdc 1 ms 5 ms 80 mA 1 mA 1.5 mA 12 Vdc±5%, 1 A minimum 1 slot 2.4 lbs (1.1 kg) AS-8535-000 Factory mutual 3610 (Requires use of key pins and MD-8741-000 barrier strip, included with module)

AS-B855-016 Mechanical Keying for Housings

AS-B863-032 Terminal Numbering and Wire Connections

30 Vdc 40 Vdc for 10ms 8 ... 11 kΩ 6 ... 8 kΩ 2 mA (typical) @ 24 Vdc 10 ms 10 ms 250 mA 0 mA 0 mA 24±6 Vdc, 20 mA 1 slot 2.31 lbs (1.05 kg) AS-8535-000

AS-B863-032 Mechanical Keying for Housings

TOP

TOP

BOTTOM

BOTTOM

(When facing housing, place pins in holes shown by black circles.)

(When facing housing, place pins in holes shown by black circles.)

3-63

Page 63

Specification

AS-B863-132

Specification

AS-B864-001

Description

24 Vdc Supervised wire input Senses & reports broken wire faults for each I/O point to PLC True High 32 4 (8 inputs per group) 9 to 15 mA per group 11 to 15 Vdc 0 to 30 Vdc 19.2 to 30 Vdc 1.8 to 3 mA low state 5.75 to 7.1 mA high state

Description Number of Points Operating Voltage Number of Groups Outputs per Group ON Current Max. per Point Max. per Group Max. per Module Leakage Current Max. Response Time OFF to ON ON to OFF Power Required +5 V +4.3 V -5 V Dimensions Space Required Weight Terminal Connector

TTL register ouput 8 channels, 16 data lines 5V TTL NA NA

Type of Operation Number of Points Number of Groups Reference Current Threshold Voltage Working Voltage Reference Voltage Input Current Transition Time ON OFF Max. Response Time OFF to ON ON to OFF Power Required + 5V +4.3V -5V External Power Supply Dimensions Space Required Weight Terminal Connector AS-B863-132 Terminal Numbering and Wire Connections

Vin = 20 Vdc 200 ms minimum Vin = 30 Vdc 25 ms minimum Vin = 20 Vdc 100 ms maximum Vin = 30 Vdc 250 ms maximum 2.0 ms, contact opening and/or closing 100 ms, fault detection time maximum 350 mA 10 mA 0mA (not used) 30 Vdc maximum 1 slot 2 lbs (0.91 kg.) AS-8535-000 AS-B863-132 Mechanical Keying for Housings

11.3 ms 11.3 ms 220 mA 180 mA 0 mA 1 slot 3.99 lbs (1.81 kg) AS-8535-000

AS-B864-001 Mechanical Keying for Housings

TOP

TOP

BOTTOM

BOTTOM

(When facing housing, place pins in holes shown by black circles.)

3-64

AS-B864-001 Terminal Numbering and Wire Connections

NA NA NA NA

(When facing housing, place pins in holes shown by black circles.)

Page 64

Specification

B865-001

Specification

AS-B872-100

Description Number of Inputs Operating Voltage Max. Response Time OFF to ON ON to OFF Power Required +5 V +4.3 V -5 V Dimensions Space Required Weight Terminal Connector

TTL register input 8 channels, 16 data lines 5 VTTL

Description Number of Channels Operating Range Max. Loop Supply Voltage Resolution Accuracy Linearity Update Times Isolation Channel to Channel Channel to Case Channel to Module Power Required +5 V +4.3 V -5 V Dimensions Space Required Weight Terminal Connector

D/A; 4 ... 20 mA 4 4 ... 20 mA 60 Vdc 12 bit ± 0.1% of full scale at 25°C 0 to 60°C, ± 1 LSB <1 ms, all 4 channels

B865-001 Terminal Numbering and Wire Connections

20 ms 20 ms 400 mA 600 mA 0 mA 1 slot 2.75 lbs (1.25 kg) AS-8535-000

B865-001 Mechanical Keying for Housings

AS-B872-100 Terminal Numbering and Wire Connections

1000 V continuous 1000 V continuous 1000 V continuous 475 mA 5 mA 0 mA 1 slot 3 lbs (1.4 kg) AS-8535-000

AS-B872-100 Mechanical Keying for Housings

TOP

TOP

BOTTOM

BOTTOM

(When facing housing, place pins in holes shown by black circles.)

(When facing housing, place pins in holes shown by black circles.)

3-65

Page 65

Specification

AS-B872-200

Specification

AS-B873-001

Description

D/A; ± 10 Vdc, ± 5 Vdc, 0 ... 10 Vdc, 0 ... 5 Vdc 4

Description Number of Channels Operating Range Voltage/Current Impedance

A/D: 4 ... 20 mA; 1 ... 5 Vdc 4

Number of Channels Operating Range Voltage Resolution Accuracy Linearity Update Times Isolation Channel to Channel Channel to Case Channel to Module Power Required +5 V +4.3 V -5 V Dimensions Space Required Weight Terminal Connector

AS-B872-200 Terminal Numbering and Wire Connections

-10 to 10 Vdc; -5 to 5 Vdc; 0 ... 5 Vdc, 0 ... 10 Vdc, selectable per channel 12 bit ± 0.1% at 25°C ± 0.17% at 0-60°C 0 to 60°C, ±1 LSB <1 ms, all 4 channels 1000 V continuous 1000 V continuous 1000 V continuous 750 mA 5 mA 0 mA

Resolution Accuracy Linearity Update Time Isolation Channel to Channel Channel to Module Power Required +5 V +4.3 V -5 V Dimensions Space Required Weight Terminal Connector

1 ... 5 Vdc / 4 ... 20 mA 1 MΩ (voltage mode) 250 Ω (current mode) 12 bit 7 mV ± .05% of full scale @ 25°C 400 ms for 4 channels 250 Vac coninuous 300 Vac continuous 300 mA 300 mA 0 mA 1 slot 3.3 lbs (1.5 kg) Included

1 slot 3 lbs (1.4 kg) AS-8535-000

AS-B872-200 Mechanical Keying for Housings

AS-B873-001 Terminal Numbering and Wire Connections

AS-B873-001 Mechanical Keying for Housings

TOP TOP

BOTTOM BOTTOM

(When facing housing, place pins in holes shown by black circles.)

3-66

(When facing housing, place pins in holes shown by black circles.)

Page 66

Specification

AS-B873-011

Specification

AS-B875-002

Description Number of Channels Operating Range Voltage/Current Impedance Resolution Accuracy Linearity Update Time Isolation Channel to Channel Channel to Module Power Required +5 V +4.3 V -5 V Dimensions Space Required Weight Terminal Connector

A/D: -10 to 10 Vdc 4

Description Number of Channels Operating Range Voltage/Current Impedance

A/D: 4 ... 20 mA; 1 ... 5 Vdc 8

AS-B873-011 Terminal Numbering and Wire Connections

-10 to 10 Vdc 1 MΩ 13 bit 17 mV ± .05% of full scale @ 25°C 400 ms for 4 channels 250 Vac continuous 300 Vac continuous 300 mA 300 mA 0 mA 1 slot 3.3 lbs (1.5 kg) Included

AS-B873-011 Mechanical Keying for Housings

TOP

BOTTOM

(When facing housing, place pins in holes shown by black circles.)

Resolution Accuracy Linearity Update Time Isolation Channel to Channel Channel to Module Transfer Times Power Required +5 V +4.3 V -5 V Dimensions Space Required Weight Terminal Connector

AS-B875-002 Terminal Numbering and Wire Connections

1 ... 5 Vdc / 4 ... 20 mA 1 MΩ (voltage mode) 250 Ω (current mode) 12 bit 7 mV ± .05% of full scale @ 25°C 710 ms for 8 channels 250 Vac continuous 300 Vac continuous 300 mA 300 mA 0 mA 1 slot 3.3 lbs (1.5 kg) Included

AS-B875-002 Mechanical Keying for Housings

TOP

BOTTOM

(When facing housing, place pins in holes shown by black circles.)

3-67

Page 67

Specification

AS-B875-012

Specification

AS-B875-102

Description Number of Channels Operating Range Voltage/Current Impedance Resolution Accuracy Linearity Update Time Isolation Channel to Channel Channel to Module Power Required +5 V +4.3 V -5 V Dimensions Space Required Weight Terminal Connector

A/D: -10 to 10 Vdc 8

Description

-10 to 10 Vdc 1 MΩ 13 bit 17 mV ± .05% of full scale @ 25°C 710 ms for 8 channels

Number of Channels Operating Range Voltage/Current

Fast A/D: ± 10 Vdc; ± 5 Vdc; 0 ... 10 V; 0 ... 5 Vdc; 1 ... 5 Vdc user selectable 4 or 8

250 Vac continuous 300 Vac continuous

Output Impedance

AS-B875-012 Terminal Numbering and Wire Connections

Resolution Accuracy Linearity Update Time

300 mA 300 mA 0 mA 1 slot 3.3 lbs (1.5 kg) Included

AS-B875-012 Mechanical Keying for Housings

AS-B875-102 Terminal Numbering and Wire Connections

30 Vac continuous 1500 Vac for 1 minute 650 mA 975 mA 0 mA 1 slot 4 lbs (1.8 kg) Included AS-B875-102 Mechanical Keying for Housings

TOP

TOP

BOTTOM

BOTTOM

(When facing housing, place pins in holes shown by black circles.)

3-68

Isolation Channel to Channel Channel to Module Power Required +5 V +4.3 V -5 V Dimensions Space Required Weight Terminal Connector

1 ... 5 Vdc / 4 ... 20 mA 0 ... 5 Vdc / 0 ... 20 mA 0 ... 10 V / 0 ... 40 mA -5 ... 5 V / -20 ... 20 mA -10 ... 10 V / -40 ... 40 mA 10 MΩ (voltage mode) 250 Ω (current mode) 12 bit ± 0.1% of full scale @ 25°C ± .02% of full scale @ 25°C 2.4 ms for 4 channels 3.0 ms for 8 channels

(When facing housing, place pins in holes shown by black circles.)

Page 68

Specification

AS-B875-111

Description

A/D: 4 ... 20 mA; 1 ... 5 Vdc; -10 to 10 Vdc; 0 ... 20 mA; -5 to 5 Vdc 8 differential or 16 single-ended (user selectable)

Number of Channels Operating Range Voltage/Current

Output Impedance Resolution Accuracy Linearity Update Time 8 inputs 16 inputs

-5 Vdc to +5 Vdc 0 to 5 Vdc 1 Vdc to 5 Vdc -10 Vdc to +10 Vdc 0 to 10 Vdc -20 mA to +20 mA 0 to 20 mA 4 to 20 mA > 10 MΩ (voltage mode) 250 Ω (current mode) 14 bit ± 0.1% ± .05%

Isolation Channel to Channel Channel to Module Power Required +5 V +4.3 V -5 V Dimensions Space Required Weight Terminal Connector

30 Vac 1500 Vac for 1 minute 500 mA 900 mA 0 mA 1 slot 3.52 lbs (1.6 kg) AS-8535-000

10 ms 20 ms

AS-B875-111 Terminal Numbering and Wire Connections 8 Differential Inputs

16 Single-Ended Inputs

AS-B875-111 Mechanical Keying for Housings TOP

BOTTOM

(When facing housing, place pins in holes shown by black circles.)

3-69

Page 69

List of 5B Packs

Specification

AS-B875-200

Description

A/D; Thermocouples, RTD Strain Gauges, 4 ... 20 mA Various Input Voltage Ranges 4/8 Selectable per channel 12 bit

Number of Channels Operating Range Resolution Accuracy Calibration Accuracy Non-Linearity Gain Drift Zero Drift Update Times Isolation Channel to Channel Power Required +5 V +4.3 V -5 V Dimensions Space Required Weight Terminal Connector

AS-B875-200 Terminal Numbering and Wire Connections

± .15% at 25° C ± .05% ± .01%/° C ± .002%/° C 4 ms, all 4 channels 1500 V continuous < 600 mA < 10 mA 0 mA 2 slots 3 lbs (1.4 kg) AS-8535-000

AS-B875-200 Mechanical Keying for Housings

TOP

BOTTOM

(When facing housing, place pins in holes shown by black circles.)

3-70

Part Number Description Voltage Input, 4 Hz. AS-5B30001A 0 to +10 mV AS-5B30002A 0 to +50 mV AS-5B30003A 0 to +100 mV AS-5B30004A -10 to +10 mV AS-5B30005A -50 to +50 mV AS-5B30006A -100 to +100 mV AS-5B31001A 0 to +1 V AS-5B31002A 0 to +5 V AS-5B31003A 0 to +10 V AS-5B31004A -1 to +1 V AS-5B31005A -5 to +5 V AS-5B31006A -10 to +10 V Voltage Input, 10KHz. AS-5B40001A 0 to +10 mV AS-5B40002A 0 to +50 mV AS-5B40003A 0 to +100 mV AS-5B40004A -10 to +10 mV AS-5B40005A -50 to +50 mV AS-5B40006A -100 to +100 mV AS-5B41001A 0 to +1 V AS-5B41002A 0 to +5 V AS-5B41003A 0 to +10 V AS-5B41004A -1 to +1 V AS-5B41005A -5 to +5 V AS-5B41006A -10 to +10 V Current Input, 4 Hz. AS-5B32001A 4 to 20 ma AS-5B32002A 0 to 20 ma Thermocouple Input, Linear, 4 Hz. AS-5B47J01A (Type J) 0 to +760°C AS-5B47J02A (Type J) -100 to +300°C AS-5B47J03A (Type J) 0 to +500°C AS-5B47K04A (Type K) 0 to +1000°C AS-5B47K05A (Type K) 0 to +500°C AS-5B47T06A (Type T) -100 to +400°C AS-5B47T07A (Type T) 0 to +200°C AS-5B47E08A (Type E) 0 to +1000°C AS-5B47R09A (Type R) +500 to +1750°C AS-5B47S10A (Type S) +500 to +1750°C AS-5B47B11A (Type B) +500 to +1800°C RTD Input, Isolated, 4 Hz. AS-5B34P01A -100 to +100°C AS-5B34P02A 0 to +100°C AS-5B34P03A 0 to +200°C AS-5B34P04A 0 to +600°C AS-5B34C01A 0 to +120°C, 10 Ω @ 0°C AS-5B34C02A 0 to +120°C, 10 Ω @ 25°C AS-5B34N01A 0 to +300°C Strain Gauge, 10 KHz. AS-5B38002A Full Bridge, 3 mV/V 300 Ω min. AS-5B38004A Half Bridge, 3 mV/V 300 Ω min. AS-5B38005A Full Bridge, 2 mV/V 300 Ω min.

Page 70

Specification

AS-B881-001

Specification

AS-B881-108

Description Type of Operation Number of Points Operating Voltage Number of Groups Inputs per Group Max. Input Voltage Continuous Surge Wetting Current Min. Pulse Width Repetition Rate Power Required +5 V +4.3 V -5 V External Power Supply Dimensions Space Required Weight Terminal Connector Fusing

24 Vdc (LATCH) input True High 16 20 ... 28 Vdc 1 16

Description Number of Points Operating Voltage Number of Groups Outputs per Group ON Current Max. per Point

115 Vac protected output 8 80 ... 130 Vac / 47 ... 63 Hz 8 1

AS-B881-001 Terminal Numbering and Wire Connections

30 Vdc 40 Vdc for 10ms 6 mA (typical) @ 24 Vdc 0.5 ms One per second 30 mA 1.1 mA 0 mA 24± 4 Vdc, 310 mA 1 slot 2.75 lbs (1.25 kg) AS-8534-000 One per group

AS-B881-001 Mechanical Keying for Housings

Max. per Group Max. per Module Leakage Current Max. Response Time OFF to ON ON to OFF Power Required +5 V +4.3 V -5 V Dimensions Space Required Weight Terminal Connector

AS-B881-108 Terminal Numbering and Wire Connections

2 A continuous 30 A for one cycle 2A 16 A 5 mA max @ 130 Vac 9 ms @ 60 Hz 9 ms @ 60 Hz 285 mA 240 mA 0 mA 1 slot 2.4 lbs (1.1 kg) AS-8535-000

AS-B881-108 Mechanical Keying for Housings

TOP

TOP

BOTTOM

BOTTOM

(When facing housing, place pins in holes shown by black circles.)

(When facing housing, place pins in holes shown by black circles.)

3-71