Page 126

F-14 OR Symbol

OR register with register (1 byte) (OR) F-14 OR

S

STR F-14

Function

The contents of the register S (8 bits) are ORed with the contents of the register D (8 bits) and its result is stored in the register D.

Operation

S∪D→D

Range of S

Range of D

04002

F-14 OR

09000

09000 09002

09002

When the input condition 04002 changes from OFF to ON, the 8 bits contents of the register 09000 are ORed with the 8 bits contents of the register 09002 and its result is stored in the register 09002. The contents of the register 09000 remain unchanged.

コ0000 to コ1577 b0000 to b0777 09000 to 09777 19000 to 19777 29000 to 29777 39000 to 39777 コ0000 to コ1577 b0000 to b0777 09000 to 09777 19000 to 19777 29000 to 29777 39000 to 39777

Before operation

After operation -ditto-

09000 0 1 0 1 0 0 1 1

09000

OR 09002 1 0 1 1 1 0 0 1

Condition

Rising edge of input signal (OFF to ON)

After operation

Contents Unchanged of S Contents Result of D

Flag

Instruction 04002

〔Example for use〕

D

1 1 1 1 1 0 1 1 09002

OR truth table Symbol A C B

Unchanged

A 0 1 0 1

B 0 0 1 1

C 0 1 1 1

9

Similarity instructions: F-14w, Fc14, Fc14w

F-14w OR Symbol

OR register with register (1 word) (OR) F-14w OR

S

〔Example for use〕

D

Function

The 16 bits contents of the registers S, S+1 are ORed with the 16 bits contents of the registers D, D+1 and its result is stored in the registers D, D+1.

Operation

S, S+1∪D, D+1→D, D+1

Range of S

Range of D

04000

Instruction 04000

STR F-14w F-14w 09000 09002 OR

09000 09002

When the input condition 04000 changes from OFF to ON, the 16 bits contents of the registers 09000 and 09001 are ORed with the 16 bits contents of the registers 09002 and 09003 and its result is stored in the registers 09002 and 09003. The contents of the registers 09000 and 09001 remain unchaged.

コ0000 to コ1576 b0000 to b0776 09000 to 09776 19000 to 19776 29000 to 29776 39000 to 39776 コ0000 to コ1576 b0000 to b0776 09000 to 09776 19000 to 19776 29000 to 29776 39000 to 39776

09001

09000

0101100101011101 OR

Before operation

Condition

After operation

09003

Rising edge of input signal (OFF to ON)

1101010010100110

Contents of S, S+1

Unchanged

Contents of D, D+1

Result

Flag

09002

09003 After operation

Unchanged

Note 1: Be sure to use even addresses for registers S and D. Similarity instructions: F-14, Fc14, Fc14w

9-51

09002

1101110111111111

Page 127

Fc14 OR Symbol

OR register with constant (1 byte) (OR) Fc14 OR n

D

Function

An octal constant "n" is ORed with the contents of the register D and its result is stored in the register D.

Operation n∪D→D

Range of "n"

000 to 377(8)

Range of D

コ0000 to コ1577 b0000 to b0777 09000 to 09777 19000 to 19777 29000 to 29777 39000 to 39777

Condition After operation

04001

Fc14 OR

123

STR Fc14

123 09002

09002

When the input condition 04001 changes from OFF to ON, the octal constant 123 is ORed with the contents of the register 09002 and its result is stored in the register 09002. Before operation 09002 1 0 1 0 1 0 1 0

After operation

OR

1 1 1 1 1 0 1 1 09002

1 2 3 Octal constant 0 1 0 1 0 0 1 1 (123)

Rising edge of input signal (OFF to ON)

OR truth table Symbol

Contents Result of D

Flag

Instruction 04001

〔Example for use〕

A 0 1 0 1

A C B

Unchanged

B 0 0 1 1

C 0 1 1 1

Similarity instructions: F-14, F-14w, Fc14w

9

Fc14w OR Symbol

OR register with constant (1 word) (OR) Fc14w OR n

D

Function

An octal constant "n" is ORed with the 16 bits contents of the registers D and D+1 and its result is stored in the registers D and D+1.

Operation n∪D, D+1→D, D+1

Range of "n"

000000 to 177777(8)

Range of D

コ0000 to コ1576 b0000 to b0776 09000 to 09776 19000 to 19776 29000 to 29776 39000 to 39776

Condition After operation

Rising edge of input signal (OFF to ON) Contents of D, D+1

Flag

04001

STR Fc14w Fc14w 026562 コ0040 OR

026562 コ0040

When the input condition 04001 changes from OFF to ON, the octal constant 026562 is ORed with the16 bits contents of the registers コ0040 and コ0041 and its result is stored in the registers コ0040 and コ0041. Octal constant 026562 0010110101110010

0

2

6

コ0041

5

6

2

コ0040

Before operation

1001100011001000

After operation

1011110111111010

Result Unchanged

Instruction 04001

〔Example for use〕

コ0041

Note 1: Be sure to use even addresses for registers D. Similarity instructions: F-14, F-14w, Fc14

9-52

コ0040

OR

Page 128

F-15 MUL Symbol

Multiply register by register (BCD 4 digits) (MULtiply) F-15 MUL

S1

S2

Function

The contents of the registers S1 and S1+1 (BCD 4 digits) are multiplied by the contents of the registers S2 and S2+1 (BCD 4 digits) and its result is stored in the 4 bytes area starting from the register D.

Operation

(S1, S1+1) × (S2, S2+1) →D, D+1, D+2, D+3

Range of S1

Range of S2

Range of D

Condition

STR F-15 04001

Before operation

09000

Tens

Ones

0

0

After operation

0

0

09020

3

4

09001

1

2

09022

0

0

09023

Thousands Hundresds

09001

0

1

× 09010

Rising edge of input signal (OFF to ON)

Tens

Ones

3

4

9

Thousands Hundresds

09011

Contents of Unchanged S1, S1+1 Contents of Unchanged S2, S1+2

1

2

The above example shows the operation of 100×1234=123400.

Contents of Result (in ones and tens) D

Contents of Result (in millions and ten millions) D+3 Zero S1, S1+1, S2, S2+1 07357 Flag BCD code 0 Not BCD code

09000 09010 09020

F-15 09000 09010 09020 MUL

When the input condition 04001 changes from OFF to ON, the BCD 4 digits in registers 09000 and 09001 are multiplied by the BCD 4 digits of registers 09010 and 09011 and its result is stored in the 4 bytes area starting from the registers 09020.

コ0000 to コ1576 b0000 to b0776 09000 to 09776 19000 to 19776 29000 to 29776 39000 to 39776 コ0000 to コ1576 b0000 to b0776 09000 to 09776 19000 to 19776 29000 to 29776 39000 to 39776 コ0000 to コ1574 b0000 to b0774 09000 to 09774 19000 to 19774 29000 to 29774 39000 to 39774

Contents of Result (in hundreds After and thousands) D+1 operation Contents of Result (in ten thousands and hundred thousands) D+2

Instruction 04001

〔Example for use〕

D

Unchanged if the contents of registers S1, S1+1, S2, and S2+1 are not BCD code.

Carry 07356

0

Error Non-carry 07354 07355

0 1

0

Similarity instructions: Fc15

9-53

Page 129

Fc15 MUL Symbol

Multiply register (BCD 4 digits) by constant (BCD 3 digits) (MULtiply) Fc15 MUL

S1 n

〔Example for use〕

D

Function

The contents of the registers S1 and S1+1 (BCD 4 digits) are multiplied by a 3 digits BCD constant "n" and its result is stored in the 4 bytes area starting from the register D.

Operation

(S1, S1+1) × n→D, D+1, D+2, D+3

Range of S1

コ0000 to コ1576 b0000 to b0776 09000 to 09776 19000 to 19776 29000 to 29776 39000 to 39776

Range of D

Condition

Rising edge of input signal (OFF to ON)

09000

100

00010010

1 09001

2

00110100

3

09000 100 09020

09020

4

00000000

0

00010010

1

09020

0 09021

2

×

Contents of Unchanged S1, S1+1

BCD constant 100

Contents of Result (in ones and tens) D

Contents of Result (in millions and ten millions) D+3 Zero S1, S1+1 07357 Flag BCD code 0 Not BCD code

Fc15 09000 MUL

3412×100=341200

コ0000 to コ1574 b0000 to b0774 09000 to 09774 19000 to 19776 29000 to 29774 39000 to 39774

Contents of Result (in hundreds and thousands) D+1 After Contents of Result (in ten thousands operation and hundred thousands) D+2

04001

When the input condition 04001 changes from OFF to ON, the BCD 4 digits in registers 09000 and 09001 are multiplied by the 3 digits BCD constant 100 and its result is stored in the 4 bytes area starting from the registers 09020.

Range of "n" 000 to 999

9

Instruction 04001

STR Fc15

Unchanged when the contents of registers S1 and S1+1 are not BCD code.

Carry 07356

0

Error Non-carry 07354 07355

0 1

0

Similarity instructions: F-15

9-54

00110100

3

09022

4

000100000000 00000000

0

0

09023

Page 130

Divide register (BCD 4 digits) by register (BCD 2 digits) (DIVide)

F-16 DIV

F-16 DIV

Symbol

S1

S2

〔Example for use〕

D

Function

The contents of the registers S1 and S1+1 (BCD 4 digits) are divied by the contents of the register S2 (BCD 2 digits) and the quotient is stored in the 2 bytes area starting from the register D and the remainder in the third byte area.

Operation

(S1, S1+1) ÷S2→D, D+1, D+2

Range of S2

Range of D

Condition

04001

09000 09010 09020

F-16 09000 09010 09020 DIV

When the input condition 04001 changes from OFF to ON, the BCD 4 digits in registers 09000 and 09001 are divided by the BCD 2 digits in registers 09010 and the quotient is stored in the 2 bytes area starting from the registers 09020 with the remainder in the 3 bytes area.

コ0000 to コ1576 b0000 to b0776 09000 to 09776 19000 to 19776 29000 to 29776 39000 to 39776 コ0000 to コ1577 b0000 to b0777 09000 to 09777 19000 to 19777 29000 to 29777 39000 to 39777 コ0000 to コ1575 b0000 to b0775 09000 to 09775 19000 to 19775 29000 to 29775 39000 to 39775

Range of S1

Instruction 04001

STR F-16

Before operation

09000

Tens

Ones

Tens

Ones

3

4

5

8

Thousands Hundresds

09001

1

09020

Quotient

Thousands Hundresds

2

0

0

Tens

Ones

Tens

Ones

2

1

1

6

09021

÷ 09010

09022 Remainder

Rising edge of input signal (OFF to ON)

Contents of Unchanged S1, S1+1 Contents of Unchanged S2

The above example shows the operation of 1234 divided by 21 equals 58 with the remainder of 16.

Contents of Quotient (in ones and tens) D After Contents of Quotient (in hundreds operation D+1 and thousands) Contents of Remainder D+2

Flag

Unchanged when the contents of registers, S1, S1+1, and S2 are not BCD code or the contents of S2 is 00.

S1, S1+1, S2

Zero 07357

Carry 07356

BCD code Not BCD code If S2 is 00

0

0

Error Non-carry 07355 07354

0 1

• If denominator is not greater than numerator (S1<S2, S1+1=0), the quotient (contents of D, D+1) is 0 and remainder (contents of D+2) is numerator (contents of S1). For instance, 20/30 will produce the result of 0 with a remainder of 20.

0

Similarity insturctions: Fc16 Reference To obtain a result of 2 places under the decimal point, the following programming is suggested. Example:1983/58=34.18 … remainder 0.56 04001

09000 09001

F-16 09000 09010 09020 DIV

①

F-01 BCD

09023

②

F-02 09022 09023 XCH

③

F-16 09022 09010 09015 DIV

④

83 19 ÷

09010

09022 09023

09000 09021 09022

34 00 11

09023

00

②

09022 09023

00 11

③

09015 09016 09017

18 00 56

Quotient

①

Remainder

58

00 11 ÷

09010

00

Quotient

Instruction 04001 STR F-16 09000 09010 09020 F-01 00 09023 F-02 09022 09023 F-16 09022 09010 09015

④

Remainder

58

9-55

① When the input condition 04001 changes from OFF to ON, the contents of registers 09000 and 09001 are divided by the contents of the register 09010 and the quotient is stored in 09020 and 09021 and remainder is stored in 09022. ② Enter data 00 in 09023. ③ The contents of 09022 are exchanged with 09023 and a remainder is converted into thousands and hundreds. ④ The data in ③ is divided by the contents of 09010 again, and a quotient is stored in 09015 and 09016 with a remainder stored in 09017. The result under 2 digits of decimal place is then stored in 09015.

9

Page 131

Fc16 DIV Symbol

Divide register (BCD 4 digits) by constant (BCD 2 digits) (DIVide) Fc16 DIV

S1 n

〔Example for use〕

D

Function

The contents of the registers S1 and S1+1 (BCD 4 digits) are divided by a 2 digits BCD contents "n" and the quotient is stored in the 2 bytes area starting from the register D and the remainder in the 3 bytes area.

Operation

(S1, S1+1) ÷ n→D, D+1, D+2

Range of S1

コ0000 to コ1576 b0000 to b0776 09000 to 09776 19000 to 19776 29000 to 29776 39000 to 39774

04001

Condition

Fc16 09000 DIV

コ0000 to コ1575 b0000 to b0775 09000 to 09775 19000 to 19775 29000 to 29775 39000 to 39775

09000 0 1 1 0 0 1 0 1

6

5

09001 1 0 0 0 0 1 1 1

8

Rising edge of input signal (OFF to ON)

09000 21 09020

7

0 0 0 1 0 1 1 1 09020

1

7

Quotient

0 0 0 0 0 1 0 0 09021

0

4

÷

Contents of Quotient (in ones and tens) D

Unchanged when the contents of registers Contents of Quotient (in hundreds S1 and S1+1 are not and thousands) D+1 After BCD code or the operation Contents of contents of "n" is 00. Remainder D+2

Flag

09020

8765÷21=417……8

Contents of Unchanged S1, S1+1

9

21

When the input condition 04001 changes from OFF to ON, the BCD 4 digits in registers 09000 and 09001 are divided by the BCD constant 21 and the quotient is stored in the 2 bytes area starting from the register 09020 with the remainder in the 3 bytes area.

Range of "n" 00 to 99

Range of D

Instruction 04001

ST R Fc16

S1, S1+1, "n"

Zero 07357

Carry 07356

BCD code Not BCD code If "n" is 00

0

0 1

BCD constant 00100001 21

Error Non-carry 07354 07355

0

0

Similarity instructions: F-16

9-56

2

●

1

0 0 0 0 1 0 0 0 09022

0

Remainder

8

If denominator is not greater than numerator (S1<n, S1+1=0), the quotient (contents of D, D+1) is 0 and remainder (contents of D+2) is numerator (contents of S1). For instance, 20/30 will produce the result of 0 with a remainder of 20.

Page 132

F-18 XOR Symbol

Exclusive OR register with register (1 byte) (eXclusive OR) F-18 XOR

S

D

Function

The contents of the register S are XORed with the contents of the register D and its result is stored in the register D.

Operation

S D→D

Range of S

Range of D

Condition

After operation

STR F-18 04001

F-18 09000 09001 XOR

09000 09001

When the input condition 04001 changes from OFF to ON, the contents of the register 09000 are XORed with the contents of the register 09001 and its result is stored in the register 09001. The contents of the register 09000 remain unchanged.

コ0000 to コ1577 b0000 to b0777 09000 to 09777 19000 to 19777 29000 to 29777 39000 to 39777 コ0000 to コ1577 b0000 to b0777 09000 to 09777 19000 to 19777 29000 to 29777 39000 to 39777

Before operation

After operation -ditto-

09000 0 0 0 0 1 1 1 1

09000

XOR 09001 1 0 0 0 1 1 1 0

1 0 0 0 0 0 0 1 09001

Bit matched in 09000 and 09001 (0 for 0, 1 for 1) is turned to 0 and unmatched bit (0 and 1) is turned to 1.

Rising edge of input signal (OFF to ON)

Exclusive OR truth table

Contents of S

Unchanged

Contents of D

Result

Flag

Instruction 04001

〔Example for use〕

Symbol

A 0 1 0 1

A C B

Unchanged

B 0 0 1 1

C 0 1 1 0

Similarity instructions: F-18w, Fc18, Fc18w

F-18w XOR Symbol

Exclusive OR register with register (1 word) (eXclusive OR) F-18w XOR

S

Function

The 16 bits contents of the registers S, S+1 are XORed with the 16 bits contents of the registers D, D+1 and its result is stored in the registers D, D+1.

Operation

S, S+1 D, D+1→D, D+1

After operation

STR F-18w 04000

F-18w 09000 09002 XOR

09001

Unchanged

Contents of D, D+1

Result

Flag

09000

0101100101011101 XOR 09003

Rising edge of input signal (OFF to ON) Contents of S, S+1

09000 09002

When the input condition 04000 changes from OFF to ON, the 16 bits contents of the registers 09000 and 09001 are XORed with the 16 bits contents of the registers 09002 and 09003 and its result is stored in the registers 09002 and 09003. The contents of the registers 09000 and 09001 remain unchanged.

コ0000 to コ1576 b0000 to b0776 Range of S 09000 to 09776 19000 to 19776 29000 to 29776 39000 to 39776 コ0000 to コ1576 b0000 to b0776 to 09776 Range of D 09000 19000 to 19776 29000 to 29776 39000 to 39776

Condition

Instruction 04000

〔Example for use〕

D

Before operation

1101010010100110

After operation

1000110111111011

09003

Unchanged

Note 1: Be sure to use even addresses for registers S and D. Similarity instructions: F-18, Fc18, Fc18w

9-57

09002

09002

9

Page 133

Fc18 XOR

Exclusive OR register with constant (1 byte) (eXclusive OR) Fc18 XOR

Symbol n

D

Function

An octal constant "n" is XORed with the contents of the register D and its result is stored in the register D.

Operation n D→D

04001

Fc18 XOR

017

STR Fc18

017 09001

09001

When the input condition 04001 changes from OFF to ON, the octal constant 017 is XORed with the contents of the register 09001 and its result is stored in the register 09001.

Range of "n" 000 to 377(8)

Range of D

コ0000 to コ1577 b0000 to b0777 09000 to 09777 19000 to 19777 29000 to 29777 39000 to 39777

Condition

Rising edge of input signal (OFF to ON)

After operation

Instruction 04001

〔Example for use〕

Before operation 09001 1 0 1 0 1 0 1 0

After operation

XOR

1 0 1 0 0 1 0 1 09001

0 1 7 Octal constant 0 0 0 0 1 1 1 1 (017)

Exclusive OR truth table Symbol

Contents Result of D

A 0 1 0 1

A C B

Flag

Unchanged

B 0 0 1 1

C 0 1 1 0

Similarity instructions: F-18, F-18w, Fc18w

9

Fc18w XOR

Exclusive OR register with constant (1 word) (eXclusive OR) Fc18w XOR

Symbol n

〔Example for use〕

D

Function

An octal constant "n" is XORed with the 16 bits contents of the registers D and D+1 and its result is stored in the registers D and D+1.

Operation n

Range of "n"

000000 to 177777(8)

Range of D

コ0000 to コ1576 b0000 to b0776 09000 to 09776 19000 to 19776 29000 to 29776 39000 to 39776

Condition After operation

D, D+1→D, D+1

Rising edge of input signal (OFF to ON) Contents of D, D+1

Flag

Fc18w 04001

Fc18w 026562 コ0040 XOR

026562 コ0040

When the input condition 04001 changes from OFF to ON, the octal constant 026562 is XORed with the16 bits contents of the registers コ0040 and コ0041 and its result is stored in the registers コ0040 and コ0041. Octal constant 026562 0010110101110010

0

2

6

コ0041

5

6

2

コ0040

Before operation

1001100011001000

After operation

1011010110111010

Result Unchanged

Instruction 04001 STR

コ0041

Note 1: Be sure to use even addresses for registers D. Similarity instructions: F-18, F-18w, Fc18

9-58

コ0040

XOR

Page 134

F-30 MCS F-31 MCR

Set master control (Master Control Set) Reset master control (Master Control Reset)

MCS and MCR can be used when the circuit is branched to a multiple number of outputs after common operational condition. 00000

00001

00400

00000

00001

00400

00002

00401

00000

00002

00401

(1) In case of a relay board 00000

(2) In case of MCS and MCR not in use

F-30 MCS

STR F-30 STR OUT STR OUT F-31

MCS

00001

00400

00002

00401

MCR

00000 00001 00400 00002 00401

F-31 MCR (3) In case of MCS and MCR in use When the F-30 (MCS) instruction is programmed, the contents of the accumulator are stored in the CPU internal register, and succeeding instructions are ANDed with the contents of the CPU internal register until the F-31 (MCR) instruction is met. The F-31 (MCR) instruction indicates the end of AND operation. It will help to simplify the program when the operational condition indicated in a block is complicated or many branches are set after the common operational condition.

Note 1: Do not directly connect the F-30 (MCS) derived bus line with OUT, TMR, and CNT instructions or application instruction. (1) In case of the relay board 00400

00000

00001

(2) MCS, MCR prohibited program 00000

F-30 MCS

00401 00400

00002

00402 00001

00401

00002

00102

F-31 MCR

Must be programmed in the following manner. 00000

00001

00400

00002

00401

TMR 010

00000

1000

F-30 MCS 00001

00400

00002

00401

F-31 MCR 00000

9-59

TMR 010

1000

Instruction 00000 STR F-30 OUT 00400 00001 STR 00401 OUT 00002 STR 00402 OUT F-31

9

Page 135

Note 2: The F-31 (MCR) instruction is an unconditional instruction. 00010

F-31 MCR

It prohibits the program like shown above. Another MCS may be used in between MCS and MCR. 00000

00001

00400

00002

00003 00401

The relay board ladder chart shown at left can be programmed in the following manner using MCS and MCR. However, there may be a need of changing the program sequence in the example(※).

00004 00402

Instruction 00000 STR F-30 STR 00001 00400 OUT 00006 STR 00404 OUT 00002 STR F-30 00003 STR 00401 OUT STR NOT 00004 00402 OUT 00005 STR 00403 OUT F-31

00005 00403

00404

00006

00000

F-30 ① MCS

00001

00400

00006

00404

00002

9

F-30 MCS

②

00003

00401

00004

00402

00005

00403

②

※

①

• The F-31 (MCR) instruction indicates the termination of the preceding F-30 (MCS) instruction ; ① and ② in the example.

F-31 MCR

Note 3: The desired circuit would not be established if programmed in the following way.

MCS

MCS

MCR MCR

Instruction 00000 STR F-30 STR 00001 00400 OUT 00002 STR F-30 00003 STR 00401 OUT STR NOT 00004 00402 OUT 00005 STR 00403 OUT F-31 00006 STR 00404 OUT F-31

00000

F-30 ① MCS

00001

00400

00002

F-30 ② MCR

00003

00401

00004

00402

00005

00403

F-31 MCR

※ 00006

This MCR is insignificant MCS of ① and ② has been terminated with this MCR.

00404

F-31 MCR

• Although it is possible to insert MCS as many times as required between MCS and MCR (※), the range of MCS terminates with MCR marked with an asterisk (※).

9-60