Page 27

Chapter 6: Wiring 6-1

Precautions for wiring (1) Separate signal lines and power line of the module from high voltage lines and power lines as far as possible. Do not run signal lines and power lines in parallel with high voltage or power lines. (2) Provide easy-to-detach wiring thoroughly considering operability at maintenance and repair. (3) M3 terminal screws are applied for either of power terminals, input terminals, and output terminals. Use crimp-style terminals equivalent to JIS standard 1.25-3, and securely fix with tightening torque 4 to 8 kgf-cm. [Recommended crimp-style terminals] JAPAN SOLDERLESS TERMINAL MFG. CO., LTD Model: 1.25-B3A 1.25-C3A 3 mm (MIN) 6 mm (MAX) 1.25-3 1.25-MS3

3 mm (MIN) 6 mm (MAX)

6 (4) Execute wiring work while opening the terminal block cover. Close this cover after the wiring work. Terminal block cover closed condition

Terminal block cover opened condition

Terminal block cover

Terminal block cover Terminal block cover

6-2

Wiring to power, FG terminals, and halt output terminals • Use twisted-pair lines of 1.25 mm2 sectional area for power lines. • Connect the halt output to the emergency stop circuit. (See "10-2 Cautions on system design") Terminal block’s lower row of JW-1624K AC-L AC-N COM.B COM.C COM.D COM.E 405 407 410 412 COM.G 415 417 420 422 424 426 COM.I HLT-C L2 FG 400 401 402 403 404 406 COM.F 411 413 414 416 COM.H 421 423 425 427 HLT L1 SHLD

(Twisted pair cables) Class-3 grounding Halt output Connect to the emergency stop circuit

85 to 250 VAC

Note 1: JW-1324K/1342K does not have halt output. 6-1

Page 28

6-3

Wiring to input terminal • Separate input lines from power lines, output lines, and power lines. • Use cables of 0.75 to 1.25 mm2 sectional area and connect using crimp-style terminals.

[1] Basic module • Upper row of the terminal block of each module is input side. (1) JW-1324K/1342K [ DC input : 16 points]

6

Terminal 0 to 3 Terminal 4 to 17 Terminal connection diagram 4 points 12 points No. of input 24 VDC Rated input voltage 12/24 VDC 10 to 26.4 VDC 20 to 26.4 VDC Input voltage range 3.6 mA TYP. (12 V) 4.8 mA TYP. Rated input current 7.6 mA TYP. (24 V) (24 V) +24V COM.A 0 2 4 6 10 12 14 16 10 V (3 mA) max. 20 V (3.5 mA) max. OV COM.A 1 3 5 7 11 13 15 17 Input ON level 5 V (1.5 mA) min. 8 V (1.5 mA) min. Input OFF level 10 ms max.(JW-1324K) Response OFF→ON 1 ms max. 1 ms max.(JW-1342K) 10 ms max.(JW-1324K) time ON→OFF 1 ms max. 1 ms max.(JW-1342K) Common system 1 common line for 16 points (no polarity) Power capacity of 24 VDC for the integrated 24 VDC ± 10%, 300mA sensor.

(2) JW-1424K/1442K [ DC input : 24 points] Terminal 0 to 3 Terminal 4 to 27 Terminal connection diagram 4 points 20 points 12/24 VDC 24 VDC 10 to 26.4 VDC 20 to 26.4 VDC 3.6 mA TYP. (12 V) 4.8 mA TYP. 7.6 mA TYP. (24 V) (24 V) +24V COM.A 0 2 4 6 10 12 14 16 20 22 24 26 10 V (3 mA) max. 20 V (3.5 mA) max. Input ON level OV COM.A 1 3 5 7 11 13 15 17 21 23 25 27 5 V (1.5 mA) min. 8 V (1.5 mA) min. Input OFF level 10 ms max.(JW-1424K) Response OFF→ON 1 ms max. 1 ms max.(JW-1442K) 10 ms max.(JW-1424K) time ON→OFF 1 ms max. 1 ms max.(JW-1442K) Common system 1 common line for 24 points (no polarity) No. of input Rated input voltage Input voltage range Rated input current

Power capacity of 24 VDC for the integrated 24 VDC ± 10%, 400mA sensor.

(3) JW-1624K/1642K [ DC input : 36 points] Terminal 0 to 3 Terminal 4 to 43 Terminal connection diagram 4 points 32 points No. of input 24 VDC Rated input voltage 12/24 VDC 20 to 26.4 VDC Input voltage range 10 to 26.4 VDC 3.6 mA TYP. (12 V) 4.8 mA TYP. Rated input current 7.6 mA TYP. (24 V) (24 V) 10 V (3 mA) max. 20 V (3.5 mA) max. Input ON level +24V COM.A 0 2 4 6 10 12 14 16 20 22 24 26 30 32 34 36 40 42 OV COM.A 1 3 5 7 11 13 15 17 21 23 25 27 31 33 35 37 41 43 5 V (1.5 mA) min. 8 V (1.5 mA) min. Input OFF level 10 ms max.(JW-1624K) Response OFF→ON 1 ms max. 1 ms max.(JW-1642K) 10 ms max.(JW-1624K) time ON→OFF 1 ms max. 1 ms max.(JW-1642K) Common system 1 common line for 36 points (no polarity) Power capacity of 24 VDC for the integrated 24 VDC ± 10%, 400mA sensor.

6-2

Page 29

■

In case of using an external power supply • If 24 VDC power for the integrated sensor is insufficient capacity, supply power from outside.

Output External power

JW-1324K

+V In case of sensor input

+24V COM.A 0

2

0V COM.A 1

4 3

300 mA

JW-1342K

6 5

Power capacity of 24 VDC for integrated sensor

Basic module

Internal circuit

0V

JW-1424K 7

JW-1442K In case of switch input

400 mA

JW-1624K JW-1642K

■

In case of using 12 V power supply • Rated input voltage of input terminals 0 to 3 is 12/24 VDC. (Available for the high-speed counter input) • In case of providing two power supplies (12 VDC and 24 VDC) separately, wire as shown below. In case of common use with 24 VDC power for the integrated sensor

In case of common use with an external 24 VDC power

0V

0V

Output

Output

Rotary encoder

External power +12V

12V

+24V COM.A 0 0V COM.A 1

Rotary encoder

External power

2

4 3

+12V

12V

6 5

+24V COM.A 0

7

0V COM.A 1

2

4 3

6 5

7

External power 24V

Note: In this case, the external 12 VDC power Note: In this case, the external 12 VDC power supply and the 24 VDC power for the supply and the external 24 VDC power integrated sensor are common for their are common for their positive (+) line positive (+) line side. Therefore, make side. Therefore, make sure to separate sure to separate them at their negative them at their negative (-) line side. (-) line side.

6-3

6

Page 30

[2] Expansion module • In JW-1124NS and JW-1324NS, upper row of the terminal block is input side. In JW-112N, upper and lower rows of the terminal block are input side. [ DC input : 16 points] ] (1) JW-112N[

Common system

Terminal connection diagram (Upper terminal)

(Lower terminal)

COM.A 0

COM.B 0

COM.A 1

2

4 3

6 5

7

COM.B 1

2

4 3

6 5

7

Power

Terminal 0 to 7 × 2 16 points 24 VDC 20 to 26.4 VDC 4.8 mA TYP. (24 V) 20 V (3.5 mA) max. 8 V (1.5 mA) min. 10 ms max. 10 ms max.

Power

No. of input Rated input voltage Input voltage range Rated input current Input ON level Input OFF level Response OFF→ON time ON→OFF

Relay numbers are allocated from 0 to 16 from upper to lower 1 common line for 8 points × 2 rows of the terminal block.

(2) JW-1124NS[ DC input : 8 points] Terminal connection diagram

COM.A 0 COM.A 1

2

4 3

6 5

7

Power

Terminal 0 to 7 No. of input 8 points Rated input voltage 24 VDC Input voltage range 20 to 26.4 VDC Rated input current 4.8 mA TYP. (24 V) Input ON level 20 V (3.5 mA) max. Input OFF level 8 V (1.5 mA) min. Response OFF→ON 10 ms max. time ON→OFF 10 ms max. Common system 1 common line for 8 points

(3) JW-1324NS[ DC input : 16 points] Terminal connection diagram Terminal 0 to 7 × 2 No. of input 16 points (Left terminal) (Right terminal) Rated input voltage 24 VDC Input voltage range 20 to 26.4 VDC Rated input current 4.8 mA TYP. (24 V) COM.ACOM.A 0 2 4 6 0 2 4 6 COM.ACOM.A 1 3 5 7 1 3 5 7 Input ON level 20 V (3.5 mA) max. Input OFF level 8 V (1.5 mA) min. Response OFF→ON 10 ms max. time ON→OFF 10 ms max. Relay numbers are allocated from 0 to 16 from left to right points Common system 1 common line for 16 points of the terminal block. Power

6

6-4

Page 31

[3] Precautions for connecting input device (1) ON/OFF time of the input signal • In order to ensure ON/OFF condition of the input device correctly (limit switch etc.) on the operation of the JW10, ON or OFF time should meet the following conditions.

ON time of the input device (TON) OFF time of the input device (TOFF)

Ton > ∆t + ton Toff > ∆t + toff ∆t 1 scanning time of PC ton OFF to ON response time of the input port toff ON to OFF response time of the input port

Ton

TOFF

Contact point of the input device

6 ton toff

Logic side of the input port Δt min.

Δt min.

• In the input/output process at the beginning of each scanning cycle, ON/OFF state of the logic side of the input port is written in the data memory and used as input data for operation of the user's program within its scanning cycle. Therefore, if ON or OFF time of the logic side of the input port is less than 1 scanning time (∆t), ON/OFF data may not be included in the data memory. Note 1: The response time of the input port is made by the electricity charge/discharge characteristics of the integral circuit of the input port, and it varies depending on the time of duration of ON or OFF.

Contact point of the input device

100% charge Upper limit value of the logic side

Electricity charge/discharge characteristics of the integral circuit toff Logic side of the input port ton toff

• toff shows the difference, shown in the above, between the case when the ON time of the contact point of the input device is longer as shown by dotted lines and the case when the ON time is shorter as shown by solid line. (Calculation example in case the JW-1324K is used as basic module) If 1 scanning time is 5ms, Ton > ∆t + ton = 5 + 10 = 15 (ms) Toff > ∆t + toff = 5 + 10 = 15 (ms)

6-5

Page 32

(2) Connectable input device • The followings are sensors and switches which can be connected as input. See below for selection and connection of the input device.

①

② NPN open-collector output type

DC 2-lines system

Input port

+

IN

IN

Ourput

Proximity switch

Input port

Sensor power supply

COM

COM 0V

③

④ PNP current output type

NPN current output type

+

6

Constant current circuit

Input port

Input port

+

Sensor power supply

Output

IN

Output

COM

0V

Sensor power supply

IN COM

0V

⑤ Contact point output type Input port IN COM

• Use a transistor having current driving capacity larger than that of the constant input current of the input port. • In case of ① , pay attention to leakage current at OFF. (When leakage current is higher than the OFF input current level of the Voltage output type input port, the proximity switch may not turn OFF.) + Positive side of power line

• Be careful that voltage output type DC input device shown in the right may not be connected. (Driving capacity of an output transistor should be higher than the ON level of the input port).

6-6

Output

0V

Page 33

(3) Countermeasure for leakage current on input device In case of connecting with limit switch with LED or the like, there is also leakage current at OFF. If the leakage current is higher than the OFF level of the input port, the input port may not turn OFF, or noise margin at OFF state may drop. (Reference)

Limit switch with LED

Calculation of leakage current iL

Input port IN RS iL=

VF

V :Power supply voltage VF:Voltage drop in the forward direction of LED RS:Current limit resistance Rin:Input impedance of input port

Rin Leakage current V

V−VF Rs+Rin iL

COM

Input port

Countermeasure Connection of bleeder resistance As a countermeasure, a bleeder resistance can be inserted in the input side of the input port as shown below.

IN

Input power supply Input device with leakage current Bleeder resistance

Choose the bleeder resistance value R to meet the following conditions:

R

6 Rin iL COM

Rin×R iL= Rin+R <Vin OFF Composite impedance of the bleeder resistance and the input impedance Vin OFF×Rin ×0.5 Rin×iL−Vin OFF

R<

Margin iL:Current leakage of the input device Vin OFF:Input of the input port OFF level voltage Rin:Input impedance of the input port V:Input power supply voltage

In this case, the rating electric power W is, W>

V2 ×3 R Margin

[Example]

In case that the JW-1324K is used as a basic module at the input power supply voltage of 24 V, and that the leakage current of the input device is 6 mA, iL = 6 mA Vin OFF = 8 V Rin = 5 kohm V = 24 V R<

8×5 5×6−8

× 0.5 = 0.909 kohm

If R is 0.9 kohm

W>

242 0.9×103

× 3 = 1.92 W

W will be 2 W.

6-7

Page 34

6-4

Wiring to output terminal • Use cables of 0.75 to 1.25 mm2 sectional area and connect using crimp-style terminals. • Make sure to insert fuses which match each load in order to secure safety for every output circuit for common.

[1] Basic module • Lower row of terminal block of each module is output side. (1) JW-1324K [ Relay output : 12 points]

L

L

L

L

Power

Load L

L

AC-L AC-N 401 403 405 407 410 412 COM.C L2 FG 400 402 404 406 COM.B 411 413 L1 SHLD

L

L

L

L

(400 to 407) 1 common line for 4 points × 1 (404 to 413)

L

L

(2) JW-1342K [ Transistor output : 12 points]

Load L

L

L

L

L

Power

Terminal connection diagram

L

AC-L AC-N 401 403 405 407 410 412 COM.C L2 FG 400 402 404 406 COM.B 411 413 L1 SHLD

L

L

L

L

L

Power

Terminal 400 to 413 12 points No. of output Rated load voltage 5/12/24 VDC Load voltage range 4.5 to 27 VDC 0.3A/point Rated max. load 1.6A/8 points common(400 to 407) current 0.8A/4 points common(410 to 413) Response OFF→ON 1 ms max.(resistance load) time ON→OFF 1 ms max.(resistance load) 1 common line for 8 points ×1 Common system (400 to 407) 1 common line for 4 points × 1 (404 to 413)

L

(3) JW-1424K [ Relay output : 16 points]

6・8

L

L

Power

Power

L

L

L

L Load

AC-L AC-N COM.B COM.C COM.D COM.E 405 407 410 412 COM.G 415 417

L

L

L

L

L

L

L

L

L

L

Power

FG 400 401 402 403 404 406 COM.F 411 413 414 416 COM.H

Power

(400 to 403) 1 common line for 4 points × 3 (404 to 417)

Power

Terminal connection diagram

Power

Terminal 400 to 417 16 points No. of output 250 VAC/30 VDC Max. open-close voltage and current 2 A/point 2 A/common 5 VDC 10 mA Min. load Response OFF→ON 10 ms max. time ON→OFF 10 ms max. 1 common line for 1 point × 4 Common system

Power

6

Terminal connection diagram

Power

Terminal 400 to 413 12 points No. of output 250 VAC/30 VDC Max. open-close voltage and current 2 A/point 2 A/common 5 VDC 10 mA Min. load Response OFF→ON 10 ms max. time ON→OFF 10 ms max. 1 common line for 8 points ×1 Common system

HLT-C L2 HLT L1 SHLD

Page 35

(4) JW-1442K [ Transistor output : 16 points]

Rated max. load current

Terminal 400 to 417 16 points 5/12/24 VDC 4.5 to 27 VDC 0.3A/point 0.8A/4 points common(404 to 417)

L

L

L

Power

Power

Power

Power

Terminal connection diagram

Power

No. of output Rated load voltage Load voltage range

L

L

L Load

AC-L AC-N COM.B COM.C COM.D COM.E 405 407 410 412 COM.G 415 417

HLT-C L2

FG 400 401 402 403 404 406 COM.F 411 413 414 416 COM.H

L

L

L

L

L

L

L

L

L

Power

L

Power

Response OFF→ON 1 ms max.(resistance load) time ON→OFF 1 ms max.(resistance load) 1 common line for 1 point ×4 Common system (400 to 403) 1 common line for 4 points × 3 (404 to 417)

HLT L1 SHLD

(5) JW-1624K [ Relay output : 24 points] Terminal 400 to 427

Terminal connection diagram

L

L

L

L

L

L

L

L

L

Power

L

Power

Power

Power

Power

Power

6

24 points No. of output 250 VAC/30 VDC Max. open-close voltage and current 2 A/point 2 A/common 5 VDC 10 mA Min. load Response OFF→ON 10 ms max. time ON→OFF 10 ms max. 1 common line for 1 point × 4 Common system

AC-L AC-N COM.B COM.C COM.D COM.E 405 407 410 412 COM.G 415 417 420 422 424 426 COM.I HLT.C L2 FG 400 401 402 403 404 406 COM.F 411 413 414 416 COM.H 421 423 425 427 HLT L1 SHLD

L

L

L

L

L

(400 to 403) 1 common line for 4 points × 3 (404 to 417) 1 common line for 8 points × 1 (420 to 427)

L

L

L

L

Power

L

Power

L

L

L

L Load

(6) JW-1642K [ Transistor output : 24 points]

L

L

L

L

L

L

L

L

L

Power

L

Power

Power

Power

Power

Terminal connection diagram

AC-L AC-N COM.B COM.C COM.D COM.E 405 407 410 412 COM.G 415 417 420 422 424 426 COM.I HLT.C L2

L

6・9

L

L

L

L

L

L

L

L

L

Power

FG 400 401 402 403 404 406 COM.F 411 413 414 416 COM.H 421 423 425 427 HLT L1 SHLD

Response OFF→ON 1 ms max.(resistance load) time ON→OFF 1 ms max.(resistance load) 1 common line for 1 point ×4 Common system (400 to 403) 1 common line for 4 points × 3 (404 to 417) 1 common line for 8 points × 1 (420 to 427)

Power

Rated max. load current

Terminal 400 to 427 24 points 5/12/24 VDC 4.5 to 27 VDC 0.3A/point 0.8A/4 points common(404 to 417) 1.6A/8 points common(420 to 427)

Power

No. of output Rated load voltage Load voltage range

L

L

L

L Load

Page 36

[2] Expansion module • In JW-1124NS and JW-1324NS, lower row of the terminal block is output side. In JW-112S and JW114S, upper and lower rows of the terminal block are output side. [ Transistor output : 16 points]

L

L

2 C(-)A 5

0

L

L

7

0

L

L

L

2 C(-)C 5

7

1

3

4

6 C(-)B

1

3

4

6 C(-)D

L

L

L

L

L

L

L

L

Power

Response OFF→ON 1 ms max.(resistance load) time ON→OFF 1 ms max.(resistance load) Common system

L

(Lower terminal)

Power

Rated max. load current

Terminal connection diagram (Upper terminal)

Power

Terminal 400 to 417 16 points 5/12/24 VDC 4.5 to 27 VDC 0.3A/point 0.8A/4 points common

No. of output Rated load voltage Load voltage range

Power

(1) JW-112S

1 common line (-) for 4 points ×4 Relay numbers are allocated from 0 to 16 from upper to lower rows of the terminal block.

[ Relay output : 16 points] Terminal connection diagram (Upper terminal) L

L

0

L

2 COM.A 5

(Lower terminal)

L

L

7

0

Power

L

L

L

2 COM.C 5

7

1

3

4

6 COM.B

1

3

4

6 COM.D

L

L

L

L

L

L

L

L

Power

Terminal 0 to 7 × 2 16 points No. of output 250 VAC/30 VDC Max. open-close voltage and current 2 A/point 2 A/common 5 VDC 10 mA Min. load Response OFF→ON 10 ms max. time ON→OFF 10 ms max. 1 common line for 4 point × 4 Common system

Power

(2) JW-114S

Power

Relay numbers are allocated from 0 to 16 from upper to lower rows of the terminal block.

[ Relay output : 8 points]

L

L

0

L

L

2 COM.B 5

7

3

4

6 COM.C

L

L

L

L

Power

1

[ Relay output : 16 points] Terminal connection diagram (Left terminal) (Right terminal) L

L

0

L

2 COM.B 5

L

L

L

L

7

0

2 COM.D 5

L

7

1

3

4

6 COM.C 1

3

4

6 COM.E

L

L

L

L

L

L

L

L

Power

Terminal 0 to 7 × 2 16 points No. of output 250 VAC/30 VDC Max. open-close voltage and current 2 A/point 2 A/common 5 VDC 10 mA Min. load Response OFF→ON 10 ms max. time ON→OFF 10 ms max. 1 common line for 4 point × 4 Common system

Power

(4) JW-1324NS

Terminal connection diagram

Power

Terminal 0 to 7 8 points No. of output 250 VAC/30 VDC Max. open-close voltage and current 2 A/point 2 A/common 5 VDC 10 mA Min. load Response OFF→ON 10 ms max. time ON→OFF 10 ms max. 1 common line for 4 point × 2 Common system

Power

(3) JW-1124NS

Power

6

Relay numbers are allocated from 0 to 16 from left to right points of the terminal block.

6・10