SHARP Programmable Controller New Satellite W series: Network module JW-20CM, Remote I/O slave module JW-20RS User's Manual: Chapter 9: Data Link, pages 149 to 158

Pages 149 to 158 of 230, from SHARP Programmable Controller New Satellite W series: Network module JW-20CM, Remote I/O slave module JW-20RS User's Manual

The original document is the PDF (2.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

Filed in the catalog under the Sharp ZW-1PU, Sharp ZW-32IO2 and Sharp ZW-32S2T

Page 149

From the previous page Set top address of flag area

File address: OCT (octal), word File number/flag: HEX (hexadecimal), byte

• Set the top address of the flag area (24 bytes) in order to monitor the communication condition and PC operation condition on the parameter address 007764 to 007767(8). • Flag area uses 24 bytes regardless number of connecting stations.

007764(8) 007765(8) 007766(8)

Initial value

Contents

Lower

E0(H)

Upper

01(H)

File number

007767(8) D7

Byte address 01E0(H)→000740(8)→コ0740

00(H)

File number 0

80(H)

Output flag

Output flag : ON Do not output flag : OFF

• In case of setting “コ0740, output flag” using JW-13PG.

Write “740(コ740)” in parameter addresses 007764 to 007765(8).

After switching to byte display, write file No. 0 with HEX (hexadecimal)

Screen display of JW-13PG 07765 07766 I PARAM. >07767

Write 80(H) to address 007767(8)

Enter communication error detection interval

HEX HEX

01 00

HEX

80

[DCM (decimal), byte]

• If the JW-20CM does not receive data from a station within the specified time (initial value: 250 ms when fewer than 32 stations are connected, 450 ms when more than 33 stations are connected), it turns OFF the communication monitor flag corresponding to this station. The specified time can be changed by entering a different value at parameter address 007771(8) (communication error detection time). Use the same value for all the stations. Normally, this value does not need to be changed. Use the modules with the initial value (00(H)).

Set value(D)

Communication error detection time (ms) ※

000

Initial value: 250 ms for fewer than 32 stations, 450 ms for more than 33 stations.

001

100

⁝

⁝

010

1000

⁝

⁝

255

2500

※ Detection time precision :, 100 ms to +0 ms Ex.: If the PC scan time is extremely long (exceeds the time specified above), the communication monitor flag will turn OFF, even though there is no communication error. In this case, change the value at parameter address 007771(8) to a larger number.

To the next page

9·51

9

Page 150

From the previous page Writing to the EEPROM of the JW-22CM, start operation [HEX (hexadecimal), byte] • Write “81(H)” into parameter address 007777(8) and write the set parameter contents into the EEPROM of the JW-20CM. • Then start the JW-20CM. After starting operation, the setting value changes to “01(H).” Setting value (H)

Contents

00

Stop operation of the JW-20CM

01

Start operation of the JW-20CM

80

Writing to the EEPROM of the JW-20CM, stop operation

81

Writing to the EEPROM of the JW-20CM, start operation

08

Initialize parameters

(Operation example of JW-13PG) Screen display of JW-13PG Display the contents of address 007777(8)

Write 81(H)

07765 07766 I PARAM. >07767

HEX HEX

01 00

HEX

80

Remarks

9

· Writing time to EEPROM is approximately 0.7 sec. When any error is found for parameter settings, the JW-20CM lights the error code (6F(H)) by the indication lamp. To recover from this condition. ■ Treatment when error code 6F(H) appears and COMM is turned OFF. ① Check number of top addresses/bytes of master station “relay link” and “register link.” ② Check the set value for number of connected stations. ③ Check the set value for master station flag top address. ④ Check whether the function is set to “relay register link.” · Written contents into the EEPROM are automatically written to the RAM of the JW-22CM when turning ON the power of the PC. At reading, the PC checks BCC and compares BCC check code of the parameter memory address (007776(8)). When an error is found, the JW20CM lights the error code (6E(H)) by the indication lamp. · If "parameter initialization" is selected, the module initializes parameter addresses 004000 to 007776(8).

PC operation Turning a master module to monitor or change mode (PC operation). (Operation example of JW-13PG)

Screen display of JW-13PG

Monitor mode Change mode

9·52

C00000 >

Page 151

9-8 Error and treatment Operation status of the JW-20CM can be check by indication lamps, flags, or system memory. (1) Indication lamp

JW–20CM COMM○ SD○ RD○ CD○ LT○ TEST○ ERROR○ FAULT○

○S0 ○S1 ○S2 ○S3 ○S4 ○S5 ○S6 ○S7

Indication lamp

Name

Operation

Recovery

COMM

Lights while the remote I/O is operating

--------------------------------------------------

SD

Flickers while sending data

--------------------------------------------------

RD

Flickers while receiving data

--------------------------------------------------

CD

Flickers while detecting a carrier

--------------------------------------------------

LT

Lights when the termination resistance switches turned ON

--------------------------------------------------

TEST

Lights while testing

--------------------------------------------------

ERROR

· Check disconnection of communication cable Lights while an error is detected (Indicate · Check settings of switches · Check settings of parameter error code by S0 to S7 LEDs) · Check power supply voltage.

FAULT

Lights when the watchdog timer is time up (JW-20CM is faulty)

Replace the JW-20CM

S0 to S7

Indicates error codes by hexadecimal when an error is occurred

See the next page

9·53

9

Page 152

(Error code) ● : ON, ○ : OFF

LED name 80 40 20 10 8 4 2 1

Error code (HEX)

Cause

Measure

○ ○ ○ ○ ○ ○ ○ ● 01(H) ROM error, upper CPU ○ ○ ○ ○ ○ ○ ● ○ 02(H) RAM error, upper CPU Replace the JW-20CM ○ ○ ○ ○ ○ ○ ● ● 03(H) 2 port RAM error against PC, upper CPU 2 port RAM error against communication CPU, upper CPU ○ ○ ○ ○ ○ ● ○ ○ 04(H)

○ ○ ○ ● ○ ○ ○ ● 11(H) ROM error, communication CPU ○ ○ ○ ● ○ ○ ● ○ 12(H) RAM error, communication CPU ○ ○ ○ ● ● ○ ○ ○ 18(H) Communication LSI error, communication CPU ○ ○ ○ ● ● ● ● ● 1F(H) No response, communication CPU

• Check the communication cable • Check for doubled allocation of slave station number • Replace the JW-20CM

○ ○ ● ○ ○ ○ ○ ○ 20(H) More than one token detected ○ ○ ● ○ ○ ○ ○ ● 21(H) Doubled address detected

Check the parameter setting, switch

○ ○ ● ○ ○ ○ ● ○ 22(H) Fault of sending section Replace the JW-20CM Token does not return within the rated interval ○ ○ ● ○ ○ ○ ● ● 23(H) Check the communication cable ○ ○ ● ○ ● ○ ● ○ 2A(H)

Over flow of receiving buffer. Occurs when the upper CPU processing is delayed. Check the communication

○ ○ ● ○ ● ○ ● ● 2B(H) Flame length error • Occurs because of a media execution cable error or noise from outside. ○ ○ ● ○ ● ● ○ ○ 2C(H) Media error ○ ○ ● ● ○ ○ ○ ○ 30(H) EEPROM error ● ○ ● ● ● ● ● ○ BE(H) BCC error ● ○ ● ● ● ● ● ● BF(H) Parameter setting error ● ● ○ ○ ○ ○ ○ ● ※C1(H) Communication error to ●● ● ● ●● ● ●

9

• After converting into octal, the lower two digits represent the slave station number of the current ※ FF(H) error. (Ex. C1(H) = 301(8) = slave station 01)

to

Check the communication cable Replace the JW-20CM Check the parameter contents

Check the communication cable and slave module

※ You need to select the "output error code for a slave station connection condition" at the master station parameter addresses 007750 to 007757(8). If more than one slave station has an error, the slave station with the lowest station number will be displayed.

Remarks • Error codes “23” and “2A(H)” may occur when applying power. This is not an error. • To check the communication cable, remove both connectors and short the connector terminals at one end. Then measure the conductivity using a tester. • Check the parameter and switch settings for all stations. If the settings are correct, replace the JW-20CM or JW-20RS.

9·54

Page 153

(2) Flag Flag area is 24 bytes from the “flag top address” set in the master station/slave station parameters. ① Flag table [ In case of flag top address is コ0740 (initial value) ] Slave station 01 (8)

Master station

コ0740

07

06

05

04

03

02

01

00

コ0741

17

16

15

14

13

12

11

10

コ0742

27

26

25

24

23

22

21

20

コ0743

37

36

35

34

33

32

31

30

コ0744

47

46

45

44

43

42

41

40

コ0745

57

56

55

54

53

52

51

50

コ0746

67

66

65

64

63

62

61

60

コ0747

77

76

75

74

73

72

71

70

コ0750

07

06

05

04

03

02

01

00

コ0751

17

16

15

14

13

12

11

10

コ0752

27

26

25

24

23

22

21

20

コ0753

37

36

35

34

33

32

31

30

コ0754

47

46

45

44

43

42

41

40

コ0755

57

56

55

54

53

52

51

50

コ0756

67

66

65

64

63

62

61

60

コ0757

77

76

75

74

73

72

71

70

コ0760

07

06

05

04

03

02

01

00

コ0761

17

16

15

14

13

12

11

10

コ0762

27

26

25

24

23

22

21

20

コ0763

37

36

35

34

33

32

31

30

コ0764

47

46

45

44

43

42

41

40

コ0765

57

56

55

54

53

52

51

50

コ0766

67

66

65

64

63

62

61

60

コ0767

77

76

75

74

73

72

71

70

① Communication monitor flag

Slave station 70 (8)

Master station

Slave station 01 (8)

② Operation condition monitor flag [1]

Slave station 70 (8)

Remarks • Even a slave station can monitor 24 bytes of flag.

9·55

Master station

Slave station 01 (8)

② Operation condition monitor flag [1]

Slave station 70 (8)

9

Page 154

② In the case of a master station (PC 00) · Communication monitor flag This flag is used to monitor the communication condition with other stations. Non-connected station keeps this flag as “OFF.” Flag operation Flag Condition for flag operation Own When the link start switch is set to “01(H),” and the master station is operating ON station normally. flag When the link start switch is set to “00(H).” (master OFF Improper setting of parameter, BCC check error, or other errors. station) Flag

Condition for flag operation

Normal communication with slave stations. Other Stopped communication or unable to station’s flag communicate with slave stations. (01 to 77) Communication monitor flag (1) of the master station is turned “OFF.”

Flag operation Specific slave station

ON

OFF

All slave stations

The master station periodically executes communication recovery operation with the communication error slave station. When the error situation is recovered, the master station returns to normal communication.

· Operation condition monitor flag [1] This flag is used to monitor the operation condition of slave stations when the communication with each slave station is normal. Non-connected station keeps this flag as “OFF.” Flag

9

Flag operation

Condition for flag operation

Own station flag Communication monitor flag (1) of the master station is turned “ON.” (master station) Communication monitor flag (1) of the master station is turned “OFF.”

Flag

Condition for flag operation Slave station is operating.

OFF

Flag operation ON

Other Slave station stops operation (not by an error cause). station’s Communication monitor flag (1) of the master flag station is turned “OFF.” (01 to 77) Slave station that communication monitor flag (1) is turned to “OFF.”

※ON

OFF

Specific slave station All slave stations

Not specified

※ Even if a master station PC has stopped operation normally or by an error, the JW-20CM turns “ON” this flag while communicating.

9·56

Page 155

· Operation condition monitor flag [2] This flag is used to monitor the abnormal stop of each slave station when the communication with each slave station is normal. Non-connected station keeps this flag as “OFF.” Flag

Condition for flag operation

Flag operation

Own Communication monitor flag (1) of the master station is turned “ON.” station flag (master station) Communication monitor flag (1) of the master station is turned “OFF.”

Flag

Condition for flag operation

※ON OFF

Flag operation

Specific Each slave station is normal. ON slave Any of the slave stations is faulty (caused to be Other station station’s stopped abnormally). Communication monitor flag (1) of the master station OFF All slave flag stations (01 to 77) is turned “OFF.” Slave station that communication monitor flag (1) is Not specified turned to “OFF.”

※ Even if a master station PC has stopped operation normally or by an error, the JW-20CM turns “ON” this flag while communicating.

9

9·57

Page 156

③ In the case of slave station (PC 01 to 77(8)) · Communication monitor flag This flag is used to monitor the communication condition with other stations. Non-connected station keeps this flag as “OFF.” Flag

Condition for flag operation When the link start switch is set to “01(H),” and at communicating with a master station normally.

Own station When the link start switch is set to “00(H).” flag When link start switch “00(H)” of the master station is OFF. Flag

Condition for flag operation

Normal communication with each station. Other Stopped communication or unable to station’s communication with each station. flag Communication monitor flag (1) of the master station is turned “OFF.”

Flag operation ON OFF

Flag operation ON

Specific station

OFF

All stations

· Operation condition monitor flag [1] This flag is used to monitor the operation condition of each station when the communication with each station is normal. Non-connected station keeps this flag as “OFF.” Flag

Flag operation

Condition for flag operation

Own Communication monitor flag (1) of the own station is turned “ON.” station Communication monitor flag (1) of the own station is turned “OFF.” flag

9

Flag

Condition for flag operation Each station is operating.

Slave station that communication monitor flag (1) is turned to “OFF.”

OFF

Flag operation ON

Other Each station stops operation (not by an error cause). station’s Communication monitor flag (1) of the own station flag is turned “OFF.”

※ON

OFF

Specific station All slave stations

Not specified

※ Even if the own station PC has stopped operation normally or by an error, the JW-20CM turns “ON” this flag while communicating.

9·58

Page 157

· Operation condition monitor flag [2] This flag is used to monitor the abnormal stop of each station when the communication with each station is normal. Non-connected station keeps this flag as “OFF.” Flag

Condition for flag operation

Flag operation

Own Communication monitor flag (1) of the own station is turned “ON.” station Communication monitor flag (1) of the own station is turned “OFF.” flag Flag

Condition for flag operation

Each station is normal. Any of the stations is faulty (caused to be stopped Other abnormally). station’s Communication monitor flag (1) of the own station flag is turned “OFF.” Slave station that communication monitor flag (1) is turned to “OFF.”

※ON OFF

Flag operation ON

Specific station

OFF

All stations Not specified

※ Even if a own station PC has stopped operation normally or by an error, the JW-20CM turns “ON” this flag while communicating.

9

9·59

Page 158

④ Monitor operation condition by each station PC By creating a program having the flags shown below in each station’s PC, the JW-20CM can monitor the operation condition of each station’s PC. [Ex.: In this case the flag top address is コ0740]

Flag top address 7 コ0740 to コ0747 コ0750 to コ0757 コ0757 to コ0760

6

5

4

3

2

1

0

Master station

07 06 05 04 03 02 01 00 to to to to to to to to

77 76 75 74 73 72 71 70 07 06 05 04 03 02 01 00 to to to to to to to to

(1) Communication monitor flag Slave station 70(8) (2) Operation condition monitor flag [1]

77 76 75 74 73 72 71 70 07 06 05 04 03 02 01 00 to to to to to to to to

(3) Oparation condition monitor flag [2]

77 76 75 74 73 72 71 70

Slave station 01

Slave station 01

Slave station 01 Slave station 01 normal operation

Communication monitor

Operation condition (1)

Operarion condition (2)

07401

07501

07601

9

9·60