Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact

The text of a manual · part 23 of 27

SHARP Programmable Controller New Satellite W series: Network module JW-20CM, Remote I/O slave module JW-20RS User's Manual: Chapter 11: Suuport Tools

Pages 188 to 197 of 230, from SHARP Programmable Controller New Satellite W series: Network module JW-20CM, Remote I/O slave module JW-20RS User's Manual

The original document is the PDF (2.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

Filed in the catalog under the Sharp ZW-1PU, Sharp ZW-32IO2 and Sharp ZW-32S2T

Page 188

Chapter 11 Support Tools The following support tools are available to record (store), and load the contents of the parameter memory. (Make sure to save the set parameters onto a floppy diskette.) Model name

Applicable floppy diskettes

Ladder software (JW-50SP)

3.5-inch 2DD/2HD, 5-inch 2DD/2HD

Multipurpose programmer (JW-50PG)

3.5-inch 2DD

Ladder processor II (Z-100LP2S)

3.5-inch 2DD

11-1 Record and load by ladder software (JW-50SP) (1) Record ① Stop operation of the JW-20CM Select “PC TRANS.” Select “Read.” Select “DL. M. stn. PARAM.” or “DL. S. stn. PARAM.” Set as the function setting condition of the connected network module. After selecting “PC stop,” press the “Enter” key.

· Communication adaptor supplied with JW-50SP Convertor supplied with JW-50SP · Control module connection cable

② Record onto the personal computer After stopping operation, record the parameters of the JW-20CM onto the memory of the personal computer. Select “Read out PARAM” and press the “Enter” key. Start reading to memory of the personal computer. ③ Start operation of the JW-20CM After recording the parameters onto the personal computer, start operation of the JW-20CM. After selecting “Start write EEPROM” or “Execution start,” press the “Enter” key.

Start operation of the JW-20CM

After selecting “PC Run,” press the “Enter” key.

Start PC operation

11·1

11

Page 189

④ Record onto a floppy diskette Write (record) the memory contents of the personal computer onto a floppy diskette. Select “FD TRANS.” Select “Save.” Select “DL. M. PARAM.” or “DL. S. PARAM.” Set as the function setting condition of the connected network module. Input a file name to record. Input comments. Press the “Enter” key. Start recording onto the floppy diskette.

11

11·2

Page 190

(2) Load ① Load to the personal computer Load the contents of the floppy diskette into the memory of the personal computer. Select “FD TRANS.”

Select “Load.”

Select a file name.

Press the “Enter” key.

Start loading into the personal computer. ② Stop operation of the JW-22CM After stopping operation, load the memory contents of the personal computer into the JW-20CM. Select “PC TRANS.”

Select “Write.” Select “DL M. stn. PARAM.” or “DL S. stn. PARAM.” Set as the function setting condition of the connected network module.

· Communication adaptor supplied with JW-50SP Convertor supplied with JW-50SP · Control module connection cable

After selecting “PC stop,” press the “Enter” key.

After selecting “Execution stop,” press the “Enter” key.

11·3

11

Page 191

③ Load to the JW-20CM After stopping operation, load the memory contents of the personal computer into the JW-20CM. After selecting “Parameter writing,” press the “Enter” key. Start loading into the JW-20CM. ④ Start operation of the JW-20CM After loading the parameters from the personal computer, start operation of the JW-20CM. After selecting “Start: write EEPROM” or “Execution start,” press the “Enter” key.

Start operation of the JW-20CM

After selecting “PC Run,” press the “Enter” key.

Start PC operation

11

11·4

Page 192

11-2 Remote function (1) Remote programming and remote monitor This paragraph describes the operation procedure of any other station's PC which is connected in the satellite net. The following support tools are available: Hand-held programmer .................. JW-13PG/12PG Multipurpose programmer .............. JW-50PG Ladder software ............................. JW-50SP

Note 1 • If the JW-20CM remotely programs or monitors the new JW30H model (JW-31CUH1/32CUH1/ 33CUH1/33CUH2/33CUH3), they should be used in the combination below. JW30H Conventional models JW-22CM (with 30Hn mark)

JW50H/70H/100H

JW-20CM (with 30Hn mark)

(Support tool) JW-13PG (with B mark) JW-50SP

If the JW-20CM, to which a support tool is connected, has a 30H sticker, the JW-20CM will identify the new JW30H model as conventional model (JW-31CUH/32CUH/33CUH). If the JW-20CM, to which a support tool is connected, does not have a 30H 30Hn sticker, it must be used with the following limitations. Ex.: · If the JW-13PG has a B sticker, it will identify the new JW30H model as JW20H (JW-22CU). · If a support tool JW-50SP is used, it will identify the new JW30H model properly. However, it cannot handle the secret function. • If the JW-20CM remotely programs or monitors the conventional JW30H model (JW-31CUH/32CUH/ 33CUH), they should be used in the combination below. JW30H Conventional models JW-22CM (with 30H 30Hn mark)

JW50H/70H/100H

JW-20CM (with 30H 30Hn mark)

(Support tool) JW-13PG (with B mark) JW-50SP

If the JW-20CM, to which a support tool is connected, does not have a 30H be used with the following limitations.

30Hn sticker, it must

Ex.: · If a support tool JW-13PG is used, it will identify the conventional JW30H model as JW20H (JW22CU). · If a support tool JW-50SP is used, it will identify the conventional JW30H model properly. However, it cannot handle the secret function.

11·5

11

Page 193

Note 2 • If you want to use the remote programming and monitoring functions with the JW50H/70H/100H, use the modules in the combinations shown below. If they are arranged in some other fashion, you cannot use the JW50H/70H/100H expansion function properly (with the JW50/70/100). JW50H/70H/100H JW13PG/12PG JW-50SP

JW-20CM JW-20RS

JW-20CM

Ex.: If remote programming or remote monitoring is executed with the combination below (enter 200(8) or 201(8) at station A system memory address #0201), there are the following limitations: · TMR/CNT1000 to 1777 will not be displayed properly. · You will be unable to write/insert/delete programs using the TMR/CNT instructions. JW50H/70H/100H Station A JW-20CM

Programmer ②

①

(

· If ① is a ZW-20CM and ② is a JW-12PG. · If ① is a ZW/JW-20CM and ② is a JW-11PG.

)

① Function <Standard network connection> Support tool n– 2 n– 1 n n+ 1 n+ 2 n+ 1

※ n+ 2

Satellite net

11

<Expansion network connection> Support tool n– 2 n– 1

Satellite net n m m+ 1 m+ 2

※ The JW-22CM is unusable as a junction station (“n + 2” station and “m” station in the figure above). Use JW30H (JW-22CM), JW50H/70H/100H (JW20CM)

The following operations are possible for “n” station and other stations using a support tool which is connected to the “n” station for standard/expansion network connection. · Change program Writing data (change program) during operation of the PC is not available for · Monitor hazard prevention reasons. Stop operation of the PC prior to writing data. · Change of parameter memory (only available for JW-13PG/12PG)

11·6

Page 194

② Operation example This paragraph describes an operation example using the multipurpose programmer: JW-50PG. For operations with other support tools, see the attached instruction manuals. • Connect the JW-50PG to the JW-20CM on the satellite net.

(JW-50PG)

• Set communication mode Set the communication mode of the JW-50PG to “Network CONCT.” and this enables remote programming and remote monitor. Select “Initial setting.”

Select “COM. set.”

Select “Network CONCT.” • Network setting Select whether the target station for remote programming or remote monitor is on the standard network connection or on the extension network connection. 10(8) In the case below, 10 to 12(8) are standard network connections. 01 to 03(8) are extension network connections.

(JW-50PG)

12(8) 11(8)

00(8)

01(8)

02(8)

03(8)

Satellite net

11

11·7

Page 195

<Standard network connection> Set “standard” in network configuration.

Set “satellite net” or “SUMINET” in target station model.

Set the target station number (00 to 77(8)). <Expansion network connection> (JW-50PG) 12(8) (Junction station) 10(8)

00(8)

11(8)

01(8)

Satellite net 0

Slot number

1

2 3

Satellite net

Set “extension” in network configuration.

Set “satellite net” or ”SUMINET” in junction station model.

Set the target station number (00 to 77(8)). (In the case of the above figure: 02(8)) Set the junction station number (00 to 77(8)).

11

(In the case of the above figure: 12(8)) Set the junction station rack number. (Keep the initial value “0”) Set the station slot number. Set the installed slot number of the master station on the target station side. In the case of the above figure: 3.

11·8

Target station 02(8)

03(8)

Page 196

(2) Parameter setting by remote function This paragraph describes how to set the parameters of other stations’ network module connected on the satellite net. This is only available when the target station is within the standard network connection. Usable support tools are JW-13PG/12PG. <An operation example using the JW-13PG> ① Connect the programmer to the network module Connect the programmer to the network module on the satellite net. ② Setting mode Select initial mode. →

Display initial mode.

③ Assign the link Assign the parameter setting remotely. → Select “LINK” in initial. → Select display mode of “1PG, 2PG1 MODE” in specified link. → Select “TARGET STA.” in 1PG, 2PG1 MODE.

④ Setting target station Select the target station to set the parameter remotely. → Change the code from hexadecimal(H) display to octal(O) display and input the target station (00(8) to 77(8)). ⑤ Communication with the target station → Initiate communication with the target station.

11·9

11

Page 197

⑥ Setting parameter After finishing communication with the target station, set the parameters remotely. → Return to initial menu. Turn the PC of the target station to program mode (stop PC operation). Select “PARAM.” in the initial mode. <<In case of remote I/O function>> →

Display contents of parameter address 003777(8).

→ Write in 00(H), stop operation of the JW-20CM. <<In case of data link function>> →

Display contents of parameter address 007777(8).

→ Write in 00(H), stop operation of the JW-20CM.

Input address

→

Display contents of address to set the parameters.

Input setting value

→

Setting parameter remotely.

⑦ Writing to the EEPROM, start operation After setting the parameter remotely in step ⑥, write 81(H) at parameter address 003777(8) (when at remote I/O function), or at 00777(8) (when at data link function), to start the "writing operation to EEPROM."

11

11·10