Page 13

Chapter 3 System Configuration (Example of system configuration)

Personal computer slave station 02(8) Master station 00(8) Slave station 01(8) JW-20CM JW-20CM PC

PC

Slave station JW20 Slave station 77(8) 03(8) JW20H JW-22CM J-board V5 JW30H Network module

Z-335J

3

Data link system (64 stations max., Total extension length: 1km max.) Compuer link system

Slave station 01(8) JW-20RS

Slave station 02(8) ZW-20RS

Slave station 77(8) JW-20RS

Remote I/O system (slave station : 63 stations max., Total extension length: 1km max.)

“PC” indicates W70H/100H, JW50/70/100, and JW50H/70H/100H.

3·1

Page 14

Chapter 4 Name and Function of Each Part 4-1

JW-20CM ①

②

⑦

③

4

④ (View removing the cover on the setting section)

⑤ ⑥

① Indication lamps Lamps light ON/OFF indicates operation condition. Name

JW–20CM COMM○ SD○ RD○ CD○ LT○ TEST○ ERROR○ FAULT○ 30Hn

○S0 ○S1 ○S2 ○S3 ○S4 ○S5 ○S6 ○S7

Operation

COMM

Lights during communicating

SD

Lights when data sending

RD

Lights when data receiving

CD

Lights when detecting carrier

LT

Lights when turning "ON" the termination resistance

TEST

Lights during testing

ERROR

Lights at a communication error

FAULT

Lights at time up of the watchdog timer

S0 to S7

Lights error code when error occurs.

② 30Hn mark (Applied to JW30H) JW-20CMs having 30Hn mark can communicate with JW30H. JW-20CMs having 30H can communicate with conventional modules of JW30H (JW-31CUH/32CUH/ 33CUH). However, when they will communicate with new modules of JW30H (JW-31CUH1/32CUH1/ 33CUH1/33CUH2/33CUH3), they recognizes these new modules as conventional modules.

4·1

Page 15

③ Support tool connection connector Connect a support tool and set parameter etc. ④ Setting switch Set functions of JW-20CM. · MODE switch .... Select functions

67

2 3 2 3

4 5 6

45

7 8

LG (ON)

Set at delivery

1

Remote I/O

0 3 OFF

Function

0

2 9 0 1

4 5 6

0

23

7 8

LT (ON)

4

0

9 0 1

×1

01

STA.NO. ×10

Number

BCD

EF

MODE

8 9A

Set at delivery

4 to F

Data link (standard function) Computer link Data link (memory capacity save function) Computer link Do not set.

ON

· S T A . N O. .... Set station number × 10, × 1 · L T .... Set ON/OFF of termination resistance · L G .... Set shield ground ON/OFF of communication cable

⑤ Communication cable connection connector BNC type receptacle (jack) ⑥ Connector protective cap ⑦ Rating plate

4·2

Page 16

4-2

JW-20RS ①

②

⑦

③

④

4 ⑤ ⑥

① Indication lamps Lamps light ON/OFF indicates operation condition.

JW–20RS COMM○ SD○ RD○ CD○ LT○ TEST○ ERROR○ FAULT○ 30Hn

○S0 ○S1 ○S2 ○S3 ○S4 ○S5 ○S6 ○S7

Name

Operation

COMM

Lights during communicating

SD

Lights when data sending

RD

Lights when data receiving

CD

Lights when detecting carrier

LT

Lights when turning "ON" the termination resistance

TEST

Lights during testing

ERROR

Lights at a communication error

FAULT

Lights at time up of the watchdog timer

S0 to S7

Indicates error code.

② 30Hn mark (Applied to JW30H) JW-20RSs having 30Hn mark can communicate with JW30H. JW-20RSs having 30H can communicate with conventional modules of JW30H (JW-31CUH/32CUH/ 33CUH). However, when they will communicate with new modules of JW30H (JW-31CUH1/32CUH1/ 33CUH1/33CUH2/33CUH3), they recognizes these new modules as conventional modules.

4·3

Page 17

③ Support tool connection connector Connect a support tool and set parameter etc. ④ Setting switch Set functions of JW-20RS. · MODE switch .... Select functions

67

0

23

45

7 8 2 3

7 8 2 3

4 5 6

0

9 0 1

4 5 6

2

9 0 1

LT (ON)

ON

LG (ON)

Output hold switch

0

Do not set.

1

Remote I/O (ZW-I/O)

2

Remote I/O (JW-I/O)

3 to F

OFF

HOLD

Do not set.

· S T A . N O. .... Set station number × 10, × 1 · L T .... Set ON/OFF of termination resistance · L G .... Set shield ground ON/OFF of communication cable

⑤ Communication cable connection connector BNC type receptacle (jack) ⑥ Connector protective cap ⑦ Rating plate ⑧ Output hold switch Set the status of the output module when the JW-20RS stops operation. ※ RST

Output hold switch ⑧

HOLD

4

Function

RST

×1

01

STA.NO. ×10

Number

BCD

EF

MODE

8 9A

Set at delivery

· In case of using ZW-I/O HOLD: Holds operation condition RST: All points is OFF · In case of using JW-I/O Be sure to setting at HOLD.

Keep the switch marked with ※ as the setting at delivery (condition in the figure above).

4·4