Page 24
Chapter 6 Processing of Cables Make sure to use the recommended models shown below for cables and connectors. Name
Cable
High frequency coaxial cable
Crimping tools Stripper for high frequency coaxial cable
Model
Maker
ME-5C-2V
Mitsubishi Cable Industries,. Ltd. Fujikura Cable,. Ltd. Furukawa Denko Corporation Chugoku Cable,. Ltd. Shinagawa Cable,. Ltd.
ME-42H Dice: 67-42H
Toko Denshi Corporation
CST-TM The system consists of the main body, a blade cassette, and a blade setting gauge
“L” jacket
SB-2878
“T” jacket
SB-2879
Self-adhesive tape
NO.11
Jacket Insulation tape
Nihon Weidmüller Co., Ltd.
Shinagawa Shoko Co., Ltd. Nitto Denko Corporation
Connector ME-GP-01 Straight ME-JJ-01 Connectors
Toko Denshi Corporation
Elbow ME-LA-01
DDK Ltd. T’s ME-TA-01
Termination ME-75
6·1
6
Page 25
6-1 Processing cable end ① Applicable cable High frequency coaxial cable: ME-5C-2V ② Required tools Stripper for high frequency coaxial cable: CST-TM ③ Processing procedure <Basic operation> Move the cam wheel of the stripper (amber colored ring) back and forth and the cable holder moves back and forth accordingly. Confirm this movement of the stripper first. To hold the stripper, put your forefinger through the hole and move the cam while pushing back and forth with your thumb.
Cable holder
Front
Cam wheel Rear
<Pressure setting>
6
Set the operation range of the cable holder by moving the slider at the bottom of the body. Move to the left to increase pressure. In this example, set the slider to the cam wheel side’s end (right side) to set the pressure to low.
Blade cassette Blade (slashed area)
Within 1 mm Set the blade to within 1 mm in order not to damage the blade by the blade setting gauge.
<Adjustment of blade cutting depth> Adjust the cutting depth of the blade by turning the two screws at both ends of the screw holder. Set the blade position to within 1 mm from the cutting surface of the blade cassette prior to adjusting the cutting depth. For the cutting depth adjustment, use the “blade setting gauge” supplied as an accessory and match the blade position with the caved position of the gauge. Then move the cam wheel forward and secure firmly. Turn right lightly both adjustment screws at either end of the screw holder for adjustment. (Be careful not to break the blade setting gauge as it is made of aluminum.)
Cam wheel Left Slider
Right
Screw holder
(Fine adjustment is required to get the optimum cutting depth.) To the next page
Blade setting gauge
6·2
Page 26
Internal conductor (annealed copper single wire) Insulator Coating External conductor (semi-transparent) (black) (meshed annealed copper wire)
From the previous page <Cutting of coating, external conductor, and insulator> Put a coaxial cable while remaining approximately 10 mm into the cable stripper and securely tighten the cable with the middle finger, ring finger, and little finger of your left hand in order to hold stable during turning the stripper. Put your right hand forefinger into the cam wheel and execute the procedure in order from step 1 below. Step 1 Press the cam wheel forward 3 times and turn the stripper in the direction of arrow 2 to 3 times. Step 2 Press the cam wheel forward 1 time and then turn the stripper in the direction of arrow a further 2 to 3 times. Step 3 Press the cam wheel forward 1 more time and turn the stripper in the direction of the arrow another 2 to 3 times. <Removal of coating, external conductor, and insulator> While holding the coaxial cable with your left hand, grip the cable stripper so that it keeps a right angle against the coaxial cable, and press out the cable stripper with your left hand’s thumb. When the adjustment of the blade is not required
If the stripper cannot be removed smoothly, adjustment of the blade is not appropriate. In this case slide the cam wheel backward and remove the coaxial cable. Then adjust the blade.
<Fine adjustment of blade cutting depth> When the cutting depth is too shallow or too deep, and damages the external conductor or the internal conductor, turn the screws on the screw holder and adjust the blade depth a little.
To the next page
6·3
10 mm
6
Page 27
From the previous page <Display of blade setting> We recommend that in order to keep the adjusted position of the adjustment screws, after completion of adjustment for the coaxial cable and the screw holder, write the screw position etc. on a sticker and adhere it to the adjustment screws.
K KE AD DA AE AD A FS KA E CA A DA AD FS
FG HH G
<Replacement of blades> Blade cassette
Hold up the upper section of the screw holder with a minus driver, and open the screw holder. Remove the blade cassette and reinsert by turning the current blade back side front or insert a new blade cassette from its top. Screw holder
6 <Processing of cable end> Cut the internal conductor of the coaxial cable, which is already cut by the stripper, using a nipper etc. to the optimum dimension of 4 mm.
10 mm±0.5 mm
A
B
A: 10±0.5 mm B: 4±0.5 mm
6·4
Page 28
6-2 Connector crimping procedure Connector parts
① Required tools: Hand-held crimping tool Model : ME-42H Dice No. : 67-42H Crimping width : 10 mm
Sleeve
Contact
Shell
② Connector: ME-GP-01
③ Processing procedure <Insert a sleeve> Put through a sleeve to an end-processed high frequency coaxial cable.
A
B
A: 10±0.5 mm B: 4±0.5 mm
Sleeve
<Crimping contact>
6
Insert a contact into the internal conductor and crimp. Internal conductor
Contact
Fixing frame
Crimping dice TT- 237 1.
9.
Put a contact into dice having a diamond shape and closely stick its end surface with the insulator and the dice. Pull the moving frame to the fixing frame side and crimp until the ratchet is removed. (Crimping width: 2.2 mm)
Moving frame Crimping dice
Widen a little Crimp Dice blade shape 2.2 mm
Insulator
Contact
Closed contact
Closed contact
6·5
1.
To the next page
TT- 237 9.
* Use the crimping tool in the direction shown in the illustration right. Using the crimping tool in the reverse direction will not crimp correctly.
Page 29
From the previous page <Fixing the connector> Slightly widen the external conductor of the coaxial cable, which is crimped to a contact on the internal conductor, in order to smoothly enter the shell inside the external conductor. Press in the external conductor end of the coaxial cable to just before the crimping part of the shell and put the sleeve into the crimping section. Then press in the coaxial cable until a “click” sound can be heard. Confirm that the contact end point touches your finger cushion.
Shell
Widen a little
Finger Sleeve
<Crimping external conductor>
Completely put into the crimping section.
Crimp the external conductor.
10
Dice blade shape Crimping dice Dice blade shape looking from this side
Push
* Use the crimping tool in the direction shown in the illustration right. Using the crimping tool in the reverse direction will not crimp correctly.
TT- 237 9.
<Insulation test> Insulation test of shell and contact Using a tester, check the conductivity between the internal conductor and the external conductor in the connector. When the indication of the tester shows ∞ ohms, the insulation is appropriate. <Conductivity test> Conductivity test After short-circuiting the one end of the connector crimped to the coaxial cable, check that conductivity is attained.
6·6
1.
6
Insert thoroughly the sleeve into the crimping section of the shell and crimp. Put the sleeve in the hexagonal dice and closely stick the shell to the crimping dice. Pull the moving frame to the fixing frame side while pressing the coaxial cable and shell from both sides, and crimp until the ratchet is removed. (Crimping width: 10 mm)
Crimping section
Closed contact