For the Siemens SCALANCE XB005

Page 21

Description of the device 3.2 Product characteristics

3.2.8

SCALANCE XB008G

Possible attachments The SCALANCE XB008G has eight RJ-45 jacks capable of Gigabit for the connection of end devices or other network segments.

Figure 3-8

SCALANCE XB008G

SCALANCE XB-000 Operating Instructions, 07/2014, A2B00077300-04

21

Page 22

Description of the device 3.3 TP ports (twisted pair)

3.3

TP ports (twisted pair)

3.3.1

Pin assignment With IE switches of the SCALANCE XB-000 product line, the twisted-pair ports are designed as RJ-45 jacks with MDI-X pin assignment (Medium Dependent Interface Autocrossover) of a network component.

Pin number

Assignment for SCALANCE XB-000

Assignment for SCALANCE XB-000G

Pin 8 n. c.

D4-

Pin 7 n. c.

D4+

Pin 6

TD-

D2-

Pin 5 n. c.

D3-

Pin 4 n. c.

D3+

Pin 3

TD+

D2+

Pin 2

RD-

D1-

Pin 1

RD+

D1+

Note TP cords or TP-XP cords with a maximum length of 10 m can be connected to the TP port with the RJ-45 jack. With the IE FC cables and IE FC RJ-45 plug 180, an overall cable length of a maximum of 100 m is permitted between two devices depending on the cable type.

SCALANCE XB-000

22

Operating Instructions, 07/2014, A2B00077300-04

Page 23

Description of the device 3.3 TP ports (twisted pair)

3.3.2

Functions

Autonegotiation With the autonegotiation mechanism, repeaters and end devices can automatically determine the transmission speed and the transmission mode of the partner port. This makes it possible to configure different devices automatically. Two components connected to a link segment can exchange information about the data transfer and can adapt their settings to each other. The mode with the highest possible speed is set. Note Devices not supporting autonegotiation must be set to 1000 Mbps/ half duplex, 100 Mbps/ half duplex or 10 Mbps half duplex. Note The IE switches of the SCALANCE XB-000 product line are plug-and-play devices that require no settings during commissioning.

Auto polarity exchange If the pair of receiving cables is connected incorrectly (RD+ and RD- interchanged), the polarity is adapted automatically.

MDI / MDI-X autocrossover function With the MPI/MDI-X autocrossover function, the send and receive contacts of an Ethernet port are assigned automatically. The assignment depends on the cable with which the communications partner is connected. This means that it does not matter whether the port is connected using a patch cable or crossover cable. This prevents malfunctions resulting from mismatching send and receive lines. This makes installation much easier for the user. The IE switches of the SCALANCE XB-000 product line all support the MDI/MDIX autocrossover function. Note Please note that the direct connection of two ports on the IE switch or accidental connection over several IE switches causes an illegal loop. Such a loop can lead to network overload and network failures.

SCALANCE XB-000 Operating Instructions, 07/2014, A2B00077300-04

23

Page 24

Description of the device 3.3 TP ports (twisted pair)

3.3.3

Insulation between the TP ports The insulation between the TP ports is based on the number of TP ports. The SCALANCE XB004 group includes the following devices: ● SCALANCE XB004-1 ● SCALANCE XB004-1LD ● SCALANCE XB004-1G ● SCALANCE XB004-1LDG The SCALANCE XB005 group includes the following devices: ● SCALANCE XB005 ● SCALANCE XB005G The SCALANCE XB008 group includes the following devices: ● SCALANCE XB008 ● SCALANCE XB008G

SCALANCE XB004 There are two TP port groups: Group1: P1 and P4 Group2: P2 and P5 Between ports of different port groups, an insulation voltage of 1.5 kV is adhered to (corresponds to IEEE802.3, Chapter 33.4.1.1, Environment B), e.g. between P1 and P2. The requirements for Environment A are met between ports of the same group, e.g. between P1 and P4.

SCALANCE XB005 There are three TP port groups: Group1: P1 and P4 Group2: P2 and P5 Group3: P3 Between ports of different port groups, an insulation voltage of 1.5 kV is adhered to (corresponds to IEEE802.3, Chapter 33.4.1.1, Environment B), e.g. between P1 and P2. The requirements for Environment A are met between ports of the same group, e.g. between P2 and P5.

SCALANCE XB-000

24

Operating Instructions, 07/2014, A2B00077300-04

Page 25

Description of the device 3.4 FO port (fiber optic)

SCALANCE XB008 There are four TP port groups: Group1: P1 and P5 Group2: P2 and P6 Group3: P3 and P7 Group4: P4 and P8 Between ports of different port groups, an insulation voltage of 1.5 kV is adhered to (corresponds to IEEE802.3, Chapter 33.4.1.1, Environment B), e.g. between P2 and P4. The requirements for Environment A are met between ports of the same group, e.g. between P1 and P5.

3.4

FO port (fiber optic)

3.4.1

SCALANCE XB004-1

Transmission rate The transmission rate of the optical Fast Ethernet port is 100 Mbps.

Transmission mode The transmission mode for 100Base-FX is specified in the IEEE 802.3 standard. Since the full duplex mode and the transmission rate cannot be modified for optical transmission, autonegotiation cannot be used.

Transmission medium Data transmission is over multimode fiber-optic cable (FOC). The wavelength is 1310 nm. Multimode fiber-optic cables are used with a core of 50 or 62.5 µm; the light source is an LED. The outer diameter of the FOC is 125 µm.

Range The maximum transmission range (segment length) with a signal attenuation of the fiberoptic cable of ≤ 1 dB/km at 1310 nm is: ● with 62.5/125 µm fiber multimode SIMATIC NET cable: 4 km ● with 50.0/125 µm fiber multimode SIMATIC NET cable: 5 km

Connectors The cables are connected to SC sockets.

SCALANCE XB-000 Operating Instructions, 07/2014, A2B00077300-04

25

Page 26

Description of the device 3.4 FO port (fiber optic)

3.4.2

SCALANCE XB004-1LD

Transmission rate The transmission rate of the optical Fast Ethernet port is 100 Mbps.

Transmission mode The transmission mode for 100Base-LX is specified in the IEEE 802.3 standard. Since the full duplex mode and the transmission rate cannot be modified for optical transmission, autonegotiation cannot be used.

Transmission medium Data transmission is over single-mode fiber-optic cable (FOC). The transceiver wavelength is 1310 nm. Single-mode fiber-optic cable with a core diameter of 10 µm is used. The outer diameter of the FOC is 125 µm.

Sender The light source is an "eye safe" class 1 laser with a wavelength of 1310 nm.

Range The maximum transmission range (segment length) is 26 km for a signal attenuation of the fiber-optic cable of ≤ 0.5 dB/km.

Connectors The cables are connected to SC sockets.

SCALANCE XB-000

26

Operating Instructions, 07/2014, A2B00077300-04

Page 27

Description of the device 3.4 FO port (fiber optic)

3.4.3

SCALANCE XB004-1G

Transmission rate The transmission rate of the optical Fast Ethernet port is 1000 Mbps.

Transmission mode The transmission mode for 1000Base-SX is specified in the IEEE 802.3z standard. Since the full duplex mode and the transmission rate cannot be modified for optical transmission, autonegotiation cannot be used.

Transmission medium Data transmission is over multimode fiber-optic cable (FOC). The wavelength is 850 nm. Multimode fiber-optic cable with a core diameter of 50 µm is used. Fiber-optic cables with a core diameter of 62.5 µm are not recommended for 1000Base-SX because this reduces the maximum segment length drastically. The outer diameter of the FOC is 125 µm.

Sender The light source is an "eye safe" class 1 laser with a wavelength of 850 nm (EN60825-1).

Range Depending on the fiber-optic cable used, the maximum transmission range (segment length) is 750 m when using SIMATIC NET fiber-optic multimode cable with SC duplex connectors or 550 m when using a standard multimode FO cable.

Connectors The cables are connected to SC sockets.

SCALANCE XB-000 Operating Instructions, 07/2014, A2B00077300-04

27

Page 28

Description of the device 3.4 FO port (fiber optic)

3.4.4

SCALANCE XB004-1LDG

Transmission rate The transmission rate of the optical Fast Ethernet port is 1000 Mbps.

Transmission mode The transmission mode for 1000Base-LH is specified in the IEEE 802.3z standard. Since the full duplex mode and the transmission rate cannot be modified for optical transmission, autonegotiation cannot be used.

Transmission medium Data transmission is over single-mode fiber-optic cable (FOC). The transceiver wavelength is 1310 nm. Single-mode fiber-optic cable with a core diameter of 10 µm is used. The outer diameter of the FOC is 125 µm.

Sender The light source is an "eye safe" class 1 laser with a wavelength of 1310 nm.

Range The maximum transmission range (segment length) is 10 km for a signal attenuation of the fiber-optic cable of ≤ 0.5 dB/km.

Connectors The cables are connected to SC sockets.

SCALANCE XB-000

28

Operating Instructions, 07/2014, A2B00077300-04

Page 29

Description of the device 3.5 LEDs

3.5

LEDs

Power LED 'L' (green LED) The power LED shows the status of the power supply. LED color

LED status

Meaning

Green

Lit

Power supply is connected

-

Off

Power supply is not connected or the applied voltage is too low. Refer also to the section "Possible sources of errors and eliminating errors (Page 41)"

Port LED 'P' (green LED) The port LEDs indicate the status of the ports. The port LEDs are located directly on the port. LED color

LED status

Meaning

Green

Lit

Link exists, no data reception at port

Green

Flashing

Link exists, data reception at port

Green

Flashing / flash on and Test phase during power on off in sequence

SCALANCE XB-000 Operating Instructions, 07/2014, A2B00077300-04

29

Page 30

Description of the device 3.5 LEDs

SCALANCE XB-000

30

Operating Instructions, 07/2014, A2B00077300-04