For the SMC EX120-SDN1

Page 1

P1650-P1724-E.qxd

08.9.2 4:10 PM

Page 1650

Integrated Type/For Output

Series EX120/121/122 - - - Series EX120

Series EX121

Series EX122

SV1000/2000/3000/4000

SY3000/5000

SY3000/5000

D

D

D

D

D

D

VQ1000/2000

How to Order SI Unit

EX12 0 S DN1 Valve interface 0 1 2

Dustproof

Plug-in

Nil

Non-dustproof

Flat ribbon cable DIN rail mounting

-XP

Dustproof

Plug-in DIN rail mounting

Note) XP is not available for DN1 and DN1-X26.

Communication protocol DN1 DN1-X26 MJ1 CS1 CS2 SL1 SL2 UW1 UH1

DeviceNet Note 1) DeviceNet Note 1) CC-Link OMRON Corp.: CompoBus/S (16 outputs) OMRON Corp.: CompoBus/S (8 outputs) SUNX Corp.: S-LINK (16 outputs) SUNX Corp.: S-LINK (8 outputs) NKE Corp.: Uni-wire System NKE Corp.: Uni-wire H System

Note 1) DN1’s occupied points are 16 inputs and 16 outputs, while DN1-X26 has 0 inputs and 16 outputs. Note 2) Please consult SMC for networks other than those mentioned above.

1650

Page 2

P1650-P1724-E.qxd

08.9.2 4:10 PM

Page 1651

Integrated Type/For Output Series

EX120/121/122

SI Unit Specifications Note 4)

Communication specification

Model

EX12쏔-SDN1 EX12쏔-SDN1-X26 EX12쏔-SMJ1

Applicable Protocol system Version Note 1)

DeviceNet

CC-Link

OMRON Corp.: CompoBus/S

SUNX Corp.: S-Link

Release 2.0

Ver. 1.10, - - - Communication speed

125 k/250 k/500 kbps

156 k/625 kbps 2.5 M/5 M/10 Mbps

750 kbps

28.5 kbps

28.5 kbps

29.4 kbps

0/16

0/16

Specified file Note 2) Occupied area (Number of inputs/outputs)

16/16

For unit

32/32 (1 station, remote I/O stations)

0/16

SCS1: 0/16 SCS2: 0/8

15 to 30 VDC 24 VDC+10%/–5%

14 to 26.4 VDC 24 VDC+10%/–5% (Common power supply) 100 mA or less

Output type

NPN output (+COM.)

Output specification

Internal current consumption (Unit)

Environmental resistance

SSL1: 0/16 SSL2: 0/8

Not applicable 11 to 25 VDC

For valve

24 VDC±10% (Common power supply)

SCS1/SSL1: 16 points SCS2/SSL2: 8 points

16 points

Number of outputs

16 points

SMC: Solenoid valve with light/surge voltage suppressor (24 VDC, 2.1 W or less)

Connection load Output when communication error occurs

NKE Corp.: NKE Corp.: Uni-wire System Uni-wire H System, EDS file

Terminal resistor Power supply

EX12쏔-SCS1 EX12쏔-SSL1 EX12쏔-SUW1 EX12쏔-SUH1 EX12쏔-SCS2 EX12쏔-SSL2

Clear

Hold/Clear (Switch setting)

Clear

Enclosure

Hold/Clear (Switch setting)

Clear

IP20

Operating temperature range

0 to +55°C (Valve 8 points ON) 0 to +50°C (Valve 16 points ON)

Operating humidity range

35 to 85%RH (With no condensation)

EX

Withstand voltage

1500 VAC for 1 min. between external terminals and case

Insulation resistance

2 MΩ or more (500 VDC) between external terminals and case

Vibration resistance

10 to 55 Hz with a 0.5 mm amplitude in each X, Y, Z direction for 2 hrs (De-energized)

Impact resistance

98 m/s2, in each X, Y, Z direction, 3 times (De-energized)

Standard Accessory

CE marking Communication connector 1 pc., Power connector 1 pc., - Note 1) Please note that the version is subject to change. Note 2) Each file can be downloaded from SMC’s website (http://www.smcworld.com/). Note 3) For detailed specifications other than the above, refer to the separate technical operation manual that can be downloaded from SMC’s website (http://www.smcworld.com/). Note 4) Since this is a special product, a manifold part number is not specified. Please consult SMC for the manifold integrated type.

1651

Page 3

P1650-P1724-E.qxd

08.9.2 4:10 PM

Page 1652

Series EX120/121/122 SI Unit Dimensions / Parts Description EX120 EX120-SMJ1, SCS쏔, SSL쏔, SUW1, SUH1

EX120-SDN1(-X26)

EX120-S쏔쏔쏔-XP Position indicator LED

Position indicator LED

Position indicator LED Terminal block cover

Terminal block cover 54

Terminal block cover

Power supply connector

64

Communication connector

Housing cover

64

1.2

63.8 64

28.8

10.2

22.5

36

60.8

60.8

5.4

Screw terminal block

28.8

15

G1/2 Conduit port

EX121 EX121-SMJ1, SCS쏔, SSL쏔, SUW1, SUH1

EX121-SDN1(-X26)

EX121-S쏔쏔쏔-XP

Position indicator LED

Position indicator LED

Position indicator LED Terminal block cover

Terminal block cover 54

Terminal block cover

Power supply connector

64

9.5

28.8

64

2

10.2

28.8

2

DIN rail mounting bracket

63.8 22.5

36

60.8

64 DIN rail mounting bracket

MIL connector (20 pins, socket) Housing cover

60.8

Screw terminal block

MIL connector (20 pins, socket) Communication connector

5.4

MIL connector (20 pins, socket)

G1/2 Conduit port

9.5

15

DIN rail mounting bracket

EX122 EX122-SMJ1, SCS쏔, SSL쏔, SUW1, SUH1

EX122-SDN1(-X26)

EX122-S쏔쏔쏔-XP

Position indicator LED

Position indicator LED

Position indicator LED

Terminal block cover

Terminal block cover 54

Terminal block cover

Power supply connector

64

36 64 DIN rail mounting bracket

1652

9.5

28.8

64 DIN rail mounting bracket

10.2

28.8

G1/2 Conduit port

63.8

Housing cover

22.5

5.4

Communication connector

60.8

60.8

Screw terminal block

9.5

15

DIN rail mounting bracket