Manual · SMC
Integrated Type/For Output Series EX120/121/122 and EX123/124/126
Manual6 pagesPDF 422 KB
Catalog pages for SMC EX120 to EX126 integrated output SI units, including the EX120-SDN1 DeviceNet unit: ordering, specs, dimensions.
What this file really is
The old site listed this file as a manual for the SMC EX120-SDN1 and EX240-IE1. Filed as an EX240-IE1 manual, but these are SMC catalog pages for the EX120 to EX126 integrated output SI units; the EX240 is not mentioned.
Names · 1 model
The models it names
Filed with · 1 model
Also filed with these models on the old site
Summary
What is in it
Six SMC catalog pages for the Series EX120, EX121 and EX122 and the Series EX123, EX124 and EX126 integrated type serial interface (SI) units for output to solenoid valve manifolds. They give how-to-order codes for each communication protocol (DeviceNet, CC-Link, CompoBus/S, S-LINK, Uni-wire), SI unit specifications such as communication speed, power supply, number of outputs and environmental ratings, replacement fuse and dripproof plug options, and dimensions with parts descriptions.
Its parts
- How to Order SI Unit EX120/121/122
- How to Order SI Unit EX123/124/126
From the manual · read page by page
Key facts from this manual
Each line names its page in the PDF.
Six catalog pages from SMC on the integrated type SI units for output, series EX120/121/122 and EX123/124/126, including the EX120-SDN1. It does not cover the EX240-IE1. It shows how to order each unit by protocol, the specifications, options and dimensions.
- Product
- SMC SI unit, integrated type for output, series EX120/121/122 and EX123/124/126 p. 1, 4
- DeviceNet versions
- DN1: 16 inputs and 16 outputs occupied; DN1-X26: 0 inputs and 16 outputs p. 1
- Output type
- NPN output (+COM.) p. 2
- Connection load
- SMC solenoid valves with light/surge voltage suppressor, 24 VDC, 2.1 W or less p. 2
- Operating temperature
- 0 to +55°C with 8 valve points on, 0 to +50°C with 16 on; 35 to 85%RH p. 2
- Enclosure
- EX120/121/122: IP20; EX123 and EX124: IP65; EX126: IP67 p. 2, 4
- Other protocols
- Also offered for CC-Link, OMRON CompoBus/S, SUNX S-LINK, NKE Uni-wire and Uni-wire H p. 1
- EX124
- EX124: separate unit and valve power, IP65, for VQ valves; mounts on the U or D side of the manifold p. 4
- EX123
- EX123: common unit and valve power, IP65, for VQ valves p. 4
- EX126D-SMJ1 fuse
- EX126D-SMJ1: replacement fuse EX9 FU20, 2.0 A p. 5
- Dripproof plug
- AXT100 B04A, for an unused G1/2 conduit port p. 5
- Conduit ports
- EX123: 2 x G1/2; EX124: 4 x G1/2 p. 6
- Mounting screws
- EX123/124/126: four M4 x 10 unit mounting screws included p. 5
- Withstand voltage
- 1500 VAC for 1 min. between external terminals and case p. 2
What this manual walks you through
- Ordering an EX120, EX121 or EX122 SI unit by protocol p. 1
- Comparing SI unit specifications across protocols p. 2
- EX120, EX121 and EX122 dimensions and parts p. 3
- Ordering an EX123, EX124 or EX126 and choosing the mounting side p. 4
- Ordering a replacement fuse and dripproof plug p. 5
- EX123, EX124 and EX126 dimensions and parts p. 6
Good to know
- The XP version is not available with DN1 or DN1-X26. p. 1
- The protocol version listed may change. p. 2
- Detailed specifications are in a separate technical operation manual. p. 2
- No manifold part number is given for the integrated type, since it is a special product. p. 2
Questions this manual answers
How many I/O points does the SMC EX120-SDN1 occupy on DeviceNet?
The DN1 version occupies 16 inputs and 16 outputs; the DN1-X26 version occupies 0 inputs and 16 outputs. p. 1, 3
What valves can these SMC SI units drive?
SMC solenoid valves with a light/surge voltage suppressor, 24 VDC and 2.1 W or less, through NPN outputs. p. 2
What is the difference between the SMC EX123 and EX124?
The EX123 shares one power supply for unit and valves while the EX124 has separate supplies; both are IP65 and fit VQ valves. p. 4
What replacement fuse does the EX126D-SMJ1 take?
Fuse EX9 FU20, rated 2.0 A. p. 5
What operating temperature do the EX120 series SI units allow?
0 to +55°C with 8 valve points on, or 0 to +50°C with 16 on. p. 2
Contents
Chapters and sections
Each line opens the PDF at its page.
The whole text · 2 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
The file


