The text of a manual · part 2 of 2

Integrated Type/For Output Series EX120/121/122 and EX123/124/126: How to Order SI Unit EX123/124/126

Pages 4 to 6 of 6, from Integrated Type/For Output Series EX120/121/122 and EX123/124/126

The original document is the PDF (422 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the SMC EX120-SDN1

Page 4

P1650-P1724-E.qxd

08.9.2 4:10 PM

Page 1653

Integrated Type/For Output

Series EX123/124/126

Series EX123

Series EX124

Series EX126

VQ2000/4000/5000

VQ2000/4000/5000

SV1000/2000/3000

VQC1000/2000/4000

D D D D D

How to Order SI Unit

EX12 3 U S SL1 Unit specifications 3

Common power supply of unit and valve Enclosure IP65 Compatible with VQ valves

Mounting specifications U D

Communication protocol SL1 SL2 UW1 UH1

SUNX Corp.: S-LINK (16 outputs) SUNX Corp.: S-LINK (8 outputs)

EX

NKE Corp.: Uni-wire System NKE Corp.: Uni-wire H System

Mount a unit to the U side of the manifold Mount a unit to the D side of the manifold

EX12 4 U S DN1 Unit specifications 4

Separate power supply of unit and valve Enclosure IP65 Compatible with VQ valves

Mounting specifications U D

Mount a unit to the U side of the manifold Mount a unit to the D side of the manifold

Communication protocol DN1 DN1-X26 MJ1 CS1 CS2

DeviceNet Note) DeviceNet Note) CC-Link OMRON Corp.: CompoBus/S (16 outputs) OMRON Corp.: CompoBus/S (8 outputs)

Note) DN1’s occupied points are 16 inputs and 16 outputs, while DN1-X26 has 0 inputs and 16 outputs.

EX12 6 D S MJ1 Unit specifications 6

Separate power supply of unit and valve Enclosure IP67 Compatible with SV/VQC valves

Communication protocol MJ1 CC-Link

Mounting specifications D

Mount a unit to the D side of the manifold

1653

Page 5

P1650-P1724-E.qxd

08.9.2 4:10 PM

Page 1654

Series EX123/124/126 How to Order Option Fuse for replacement A fuse for replacement used for EX126D-SMJ1.

Fuse

EX9 FU20 Applicable model

EX126D-SMJ1

Rated current

2.0 A

Dripproof plug assembly Use for the unused conduit port (G1/2).

AXT100 B04A

SI Unit Specifications The electrical specification is the same for EX12쏔. Refer to page 1651. 4 unit mounting screws (M4 x 10) are included when shipped.

1654

Page 6

P1650-P1724-E.qxd

08.9.2 4:10 PM

Page 1655

Integrated Type/For Output Series

EX123/124/126

SI Unit Dimensions/Parts Description EX123쏔-S쏔쏔쏔, EX124쏔-S쏔쏔쏔 Screw terminal block

Position indicator LED

53.8

19

11.6

56.4

Housing cover diagram 19

114

EX123쏔: 2 x G1/2 EX124쏔: 4 x G1/2 Conduit port

67

(72.5)

19.8

5.5

Housing cover

EX

EX126D-SMJ1

Position indicator LED

Screw terminal block

Housing cover

Housing cover diagram

19.8

67

(72.5)

114

5.5

34.8 Power supply fuse for solenoid valve

Power supply fuse for communication

6.6

30.4

65.2

42

4 x G1/2 Conduit port

Housing bottom diagram

1655