The text of a manual · part 2 of 2
Integrated Type/For Output Series EX120/121/122 and EX123/124/126: How to Order SI Unit EX123/124/126
Pages 4 to 6 of 6, from Integrated Type/For Output Series EX120/121/122 and EX123/124/126
The original document is the PDF (422 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the SMC EX120-SDN1
Page 4
P1650-P1724-E.qxd
08.9.2 4:10 PM
Page 1653
Integrated Type/For Output
Series EX123/124/126
Series EX123
Series EX124
Series EX126
VQ2000/4000/5000
VQ2000/4000/5000
SV1000/2000/3000
VQC1000/2000/4000
D D D D D
How to Order SI Unit
EX12 3 U S SL1 Unit specifications 3
Common power supply of unit and valve Enclosure IP65 Compatible with VQ valves
Mounting specifications U D
Communication protocol SL1 SL2 UW1 UH1
SUNX Corp.: S-LINK (16 outputs) SUNX Corp.: S-LINK (8 outputs)
EX
NKE Corp.: Uni-wire System NKE Corp.: Uni-wire H System
Mount a unit to the U side of the manifold Mount a unit to the D side of the manifold
EX12 4 U S DN1 Unit specifications 4
Separate power supply of unit and valve Enclosure IP65 Compatible with VQ valves
Mounting specifications U D
Mount a unit to the U side of the manifold Mount a unit to the D side of the manifold
Communication protocol DN1 DN1-X26 MJ1 CS1 CS2
DeviceNet Note) DeviceNet Note) CC-Link OMRON Corp.: CompoBus/S (16 outputs) OMRON Corp.: CompoBus/S (8 outputs)
Note) DN1’s occupied points are 16 inputs and 16 outputs, while DN1-X26 has 0 inputs and 16 outputs.
EX12 6 D S MJ1 Unit specifications 6
Separate power supply of unit and valve Enclosure IP67 Compatible with SV/VQC valves
Communication protocol MJ1 CC-Link
Mounting specifications D
Mount a unit to the D side of the manifold
1653
Page 5
P1650-P1724-E.qxd
08.9.2 4:10 PM
Page 1654
Series EX123/124/126 How to Order Option Fuse for replacement A fuse for replacement used for EX126D-SMJ1.
Fuse
EX9 FU20 Applicable model
EX126D-SMJ1
Rated current
2.0 A
Dripproof plug assembly Use for the unused conduit port (G1/2).
AXT100 B04A
SI Unit Specifications The electrical specification is the same for EX12쏔. Refer to page 1651. 4 unit mounting screws (M4 x 10) are included when shipped.
1654
Page 6
P1650-P1724-E.qxd
08.9.2 4:10 PM
Page 1655
Integrated Type/For Output Series
EX123/124/126
SI Unit Dimensions/Parts Description EX123쏔-S쏔쏔쏔, EX124쏔-S쏔쏔쏔 Screw terminal block
Position indicator LED
53.8
19
11.6
56.4
Housing cover diagram 19
114
EX123쏔: 2 x G1/2 EX124쏔: 4 x G1/2 Conduit port
67
(72.5)
19.8
5.5
Housing cover
EX
EX126D-SMJ1
Position indicator LED
Screw terminal block
Housing cover
Housing cover diagram
19.8
67
(72.5)
114
5.5
34.8 Power supply fuse for solenoid valve
Power supply fuse for communication
6.6
30.4
65.2
42
4 x G1/2 Conduit port
Housing bottom diagram
1655