The text of a spec sheet · part 4 of 5

POWERLINK AS Lighting Control System Catalog, pages 31 to 40

Pages 31 to 40 of 49

The original document is the PDF (2.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Square D AS42C and Schneider AS42C

Page 31

Dimensions 20 in. (508 mm) Wide Enclosures NEHB Main Lug Panelboards (225 Ampere Maximum Main Lugs) 2.00

2.50

8.50

51

64

216

Flush Lock

Interior Trim

A

B

H

Flush Mounting H + 1.50 38

Surface Mounting H + .13 3

Directory Card Holder

2.50 64

TYPICAL FRONT

2.50

10.44 4.78

265

121

20.00

5.75

64

146

4.78 121

508

TYPICAL BOX SIDE VIEW

TYPICAL BOX WITH INTERIOR

3.06 78

7.69 195

Flush Mounting 21.50 546

3.06

1.38 TYP.

78

35 15 ( 1 2, 3 4 ) Concentric KO.

20.13

6 ( 1 2, 3 4 ) Concentric KO.

Surface Mounting 511

Concealed Trim Clamps 1 (11 4, 11 2, 2, 21 2, 3, 31 2 ) Concentric KO.

1 (11 4, 11 2, 2, 21 2, 3) Concentric KO.

Concealed Door Hinges

TYPICAL MOUNTING OF EH OR EHB BREAKERS

TYPICAL ENDWALL

Dimensions:

Note: Refer to page 34 for keyhole and endwall detail.

Maximum Maximum Main Lug Number of Ampere PowerLink Rating Circuits 125

225

32

Required Panel Interior Size

H Box Height

INCHES mm

A B Mounting Studs Mounting Holes

IN mm

IN mm

IN mm

12

18

29.00

737

24.00

610

25.00

635

24

30

35.00

889

30.00

762

31.00

787

24

30

35.00

889

30.00

762

31.00

787

36

42

41.00

1041

36.00

914

37.00

940

42

54

47.00

1194

42.00

1067

43.00

1092

S/N

TYPICAL WIRING DIAGRAM

SQUARE D

9/98

Page 32

Dimensions 20 in. (508 mm) Wide Enclosures NEHB Main Circuit Breaker Panelboards (250 Ampere Maximum Main Breaker) 2.00

2.50

8.50

51

64

216

B

A

H minus 7.22 183

Flush Lock

H

TYPICAL BOX SIDE VIEW

TYPICAL BOX WITH INTERIOR

Flush = H plus 1.50 38

Interior Trim

Surface = H plus .13 3

Directory Card Holder

2.50 64

12.68 2.50

10.44

64

265

4.78

78

TYPICAL FRONT

121

508

3.06

146

4.78

20.00

121

322

5.75

7.69 195

TYPICAL MOUNTING OF EH OR EHB BREAKERS

3.06

1.38 TYP.

78

35 15 ( 1 2, 3 4 ) Concentric KO.

6 ( 1 2, 3 4 ) Concentric KO.

Flush Mounting 21.50 546

20.13

Surface Mounting 511

TYPICAL ENDWALL Concealed Trim Clamps 1 (11 4, 11 2, 2, 21 2, 3, 31 2 ) Concentric KO.

1 (11 4, 11 2, 2, 21 2, 3) Concentric KO.

Dimensions:

Note: Refer to page 34 for keyhole and endwall detail.

Maximum Main Maximum Circuit Breaker Number of PowerLink Ampere Rating Circuits 125

250

Required Panel Interior Size

H Box Height

INCHES mm

A B Mounting Studs Mounting Holes

IN mm

IN mm

IN mm

12

18

38.00

965

33.00

838

34.00

864

24

30

44.00

1118

39.00

991

40.00

1016

24

30

47.00

1194

42.00

1067

43.00

1092

36

42

53.00

1346

48.00

1219

49.00

1245

42

54

59.00

1449

54.00

1372

55.00

1397

SQUARE D

9/98

Concealed Door Hinges

S/N

TYPICAL WIRING DIAGRAM

33

Page 33

Dimensions 20 in. (508 mm) Wide Enclosures NQOD and NEHB Keyhole and Endwall Detail 0.31 8

1.12 1.75 44

28

0.50 13

3.06 78

3.00

1.38 Typ.

76

1.38

24 (1⁄2, 3⁄4) Concentric KO

1 (3⁄4, 11⁄2, 2, 21⁄2) Concentric KO

35

7.69 195

3.06 78

35

1 (11⁄4, 11⁄2, 2, 21⁄2, 3, 31⁄2) Concentric KO

15 (1⁄2, 3⁄4) Concentric KO 9

⁄32 KO

14" Wide Endwall with Knockouts (Other Endwall is Blank)

6 (1⁄2, 3⁄4) Concentric KO

1 (11⁄4, 11⁄2, 2, 21⁄2, 3) Concentric KO

20" Wide Endwall with Knockouts (Other Endwall is Blank)

Keyhole Detail (2 Holes Typical)

Dimensions:

34

INCHES mm

SQUARE D

9/98

Page 34

Accessories Desktop Power Supply POWERLINK AS desktop programming power supplies allow POWERLINK AS control modules to be programmed without being installed in the panel. The desktop power supply operation is very similar to a standard calculator type power supply. Simply plug the power supply into a standard 120V, 60 Hz wall outlet, and insert the 9-pin connector into the back of the module. Desktop power supply connected to control module

When powering up, the control module will follow its initialization sequence, and then display the status screen. Since the control module is not installed in a panel, it will assume that 42 1-pole POWERLINK AS circuit breakers are present. This permits all 42 circuit breaker locations to be programmed. Multi-pole breakers can be programmed by selecting the pole number corresponding to the motor location (see figure 7 below). Desktop programming of the control module can be done by either of the methods listed below: Using application software: • Connect a PC directly to the RS-232 port on the control module via the AS42CM-SC cable. • Download programs from either PLK 101 or CMS 1000 software. From control module: • Program the control module by manually selecting the desired functions using the module’s 24-button keypad. (For more information, see the control module section on page 20.

Control module connected to PC via AS42CM-SC cable

After the control module is programmed, it is ready for installation in the panelboard.

AS42CM-SC Cable

Figure 7 - Motor Location (

Indicates motor pole)

SELECTION DATA Description Desktop Power Supply RS-232 Download Cable

Catalog Number AS42CM-DPK AS42CM-SC

SQUARE D

9/98

35

Page 35

Accessories Input Expansion Cabinet The POWERLINK system input expansion cabinet allows you to multiply the benefits of the POWERLINK AS remote power switching system without complicated installation or operation procedures. It provides as many as 48 additional inputs over the 16 inputs available within the POWERLINK AS system. The POWERLINK system input expansion cabinet is ideal for new or retrofit lighting applications. Its efficient design significantly reduces installation and maintenance time, while its low voltage switching (24V) provides safe and easy operation.

Input Expansion Cabinet

The input expansion cabinet provides 42 additional outputs and 48 additional inputs over the 16 inputs available within the

Installation costs are reduced because the system accepts low voltage Class 2 wiring, which typically requires no conduit. Inputs used with Class 2 wiring include low voltage switches, motion detectors, and photo cells, which can be 2-wire maintained, 2-wire momentary, or 3-wire momentary. In most lighting applications, low voltage switches operating at 24Vdc will be used. These switches can be conveniently programmed to provide a variety of tasks, including simple on/off switching, overriding a programmed event, or acting as a simple timer. The POWERLINK system input expansion cabinet is easily reprogrammed to meet a facility’s changing requirements without rewiring. Each of the 48 inputs can be individually activated by input control devices. And with the system’s superior design flexibility, there can be as few as one or as many as 48 inputs per zone. If your objective is to reduce energy costs and take advantage of remote low voltage switching, the POWERLINK system input expansion cabinet is your best solution.

POWERLINK AS COMPONENTS system. It’s a simple and low cost way to multiply your system’s capabilities.

AS48EXP • Input/output expansion cabinet • Accepts (2) AS24IN and (1) AS42OUT modules • Sources control power for dry contact type inputs and outputs AS24IN • Provides for 24 additional 2-wire maintained or 3-wire momentary contact inputs AS48OUT • Provides for 42 additional outputs • 115 mA maximum current per output • Total current load not to exceed 1.65 A on all outputs

36

SQUARE D

9/98

Page 36

Accessories Input Expansion Cabinet SELECTION DATA Description

Catalog Number

Input Expansion Chassis, accepts up to two AS24IN and one AS42OUT Modules

AS48EXP*

Input Module, contains provisions for 24 inputs

AS24IN**

Output Module, contains provisions for 42 outputs

AS42OUT

Expander Enclosure

MH26-BEPL

Surface Cover for AS48EXP

MHC26PL-S

Flush Cover for AS48EXP

MHC26PL-F

* Input Expansion Cabinet includes power supply, interior, and serial communication board for connection to the power interface module.

** AS24IN accepts either 2-wire maintained, 2-wire momentary, or 3-wire momentary input signals.

Selection Criteria Mounting Options • Expander can be mounted as a stand-alone cabinet up to 50 feet away from a POWERLINK panel. • Expander can also be mounted directly above or below the POWERLINK panel. Covers • Choice of flush or surface covers Modular Construction • Allows unit to be configured as needed. Either one or two input modules and be provided for 24 or 48 inputs. • Optional output card can also be easily installed. POWERLINK Input Expansion Cabinet Enclosure Dimensions NEMA Type 1 Enclosure (Indoor) W

H

D

20*

26*

5.75*

* Dimensions in inches

SQUARE D

9/98

37

Page 37

Network Options General Information Individual POWERLINK AS panelboards can be easily integrated into a single system, using a variety of flexible network options. Such systems combine the power of network communications with personal computers to provide centralized setup, monitoring, and control. POWERLINK AS panelboards can easily be integrated with Square D POWERLOGIC circuit monitors to form a complete power monitoring and control system. In addition, a number of third party building automation companies, including Honeywell, Johnson Controls, Landis & Stafa, and Siebe, have developed interface modules that will allow POWERLINK panels to be remotely operated directly from their systems.

Figure 8 - Configuration example: POWERLINK lighting control system using RS-485

Square D panelboards are designed to operate using either of two distinct protocols. The POWERLOGIC network provides an excellent system for controlling POWERLINK panels from Square D Circuit Manager or System Manager software. POWERLOGIC networks can support both POWERLINK AS panelboards and other POWERLOGIC compatible products. For additional information on POWERLOGIC networks, refer to the Power Monitoring and Control System Planning Guide Bulletin #3000CT9601. The POWERLINK AS lighting control system offers connection to Ethernet TCP/IP networks to make lighting control available over new and existing local and wide area networks. From a central location, you can now better manage your energy cost using Ethernet technology as well as the internet. Additional information on using Ethernet networks can be found in the Power Monitoring and Control System Catalog Bulletin 3000CT9701.

Figure 9 - Configuration example: POWERLINK lighting control system using Ethernet

The POWERLINK AS system also supports LONWORKS communications. This peer-to-peer protocol is quickly becoming the industry standard for building controls, as it ensures system flexibility and interoperability between devices connected to the network. Refer to page 39 for additional information on the LonWorks Gateway.

38

SQUARE D

9/98

Page 38

Network Options LonWorks Gateway What is LONWORKS? LONWORKS represents the future of field bus communication between intelligent devices. Past means of communicating between devices were usually developed by manufacturers of specific hardware products, and were highly proprietary. Equipment from one manufacturer usually could not communicate well with equipment made by another. In addition, older protocols were generally slow and often did not allow different pieces of equipment to communicate directly with each other as peers. In contrast, LONWORKS was independently developed and is completely open to all manufacturers. And LONWORKS takes advantage of the latest technology to provide high-speed, peer-to-peer communications.

LONWORKS Communication Module

The high speed peer-

The open LONWORKS protocol allows users to select and integrate the best equipment from each manufacturer. It allows manufacturers to concentrate on their expertise, rather than be diverted making proprietary interfaces, modems, and software.

LONWORKS Connections to-peer nature of

All new and existing POWERLINK AS panels can operate with the LONWORKS communication module, which connects directly to the POWERLINK AS power interface module’s RS-232 expander port. A POWERLINK AS control module may be needed for panel setup, but not for routine operation with LONWORKS.

LONWORKS makes many things possible. For example, an input

Network Setup/Programming switch in one panel

Logically connecting I/O and circuit breakers in different panels or devices is done through a process called “binding.” This process is accomplished using any number of third party software tools.

can control circuit breakers in any panel

Setup and programming within a POWERLINK AS panel is still performed using POWERLINK PLK-101 or CMS 1000 software, or the optional display control module.

on the network. A time-of-day control can control breakers

POWERLINK AS panels equipped for network communication can use the network for monitoring and programming while connected to LONWORKS for control.

in many panels. And

Configuration module in one panel

The remote-control circuit breakers and dry-contact switch inputs of the POWERLINK AS system are available for use as LONWORKS objects through the POWERLINK AS-to-LONWORKS network interface.

third party I/O and software can interface directly with POWERLINK AS inputs and breakers.

SELECTION DATA Description

Catalog Number

LONWORKS Communication Module

ASLCM-F

SQUARE D

9/98

39

Page 39

Software Overview POWERLINK AS software makes controlling lighting and power intuitive and easy to understand. From small, stand-alone applications to complete power monitoring and control installations, graphical software from Square D helps you save time and money.

Ease of Use The two levels of POWERLINK AS system software are PLK 101 or Circuit Manager Software (CMS). Simple point-and-click icons and graphical panels mean that you do not need to understand lighting industry jargon. Just change the picture until it shows what you want to happen.

Point-and-click graphical screens make programming a cinch, especially for nonexperts.

POWERLINK AS software runs on a personal computer under either Windows® 3.1, 95, 98, or NT. A cable that comes with the software is used to connect the serial port of the PC directly to a control module’s RS-232 port. Or, for larger systems, the PC can be connected to the panels via a POWERLOGIC network. Of the two software platforms, CMS offers the more advanced functionality. CMS features allow you to: • View multiple panelboards simultaneously • Use system approach to panelboard setup • Remotely verify circuit breaker status • Remotely override circuit breakers and zones • Globally synchronize time clocks • Print panel schedules and directory cards • Enter password protection

Documenting Your Work Better than being there! Monitor circuit breaker, input, and panel status from a remote PC with CircuitManager or PLK software. Operate single circuit breakers or entire zones for temporary or permanent changes.

A practical problem with traditional hardwired control is that the wiring diagrams become lost or out of date. When changes later need to be made, the wiring must then be hand traced - or, in frustration, ripped out and new wiring installed. POWERLINK AS lets you leave those days behind. Square D software lets you save all of your panel configurations on a floppy disk. In addition, CircuitManager software can print out your programs, panel schedules, and more. Lost your program? No problem; just connect your PC to the panel and download it all. Because POWERLINK AS is completely integrated, there is a single panel schedule and control setup. POWERLINK AS offers the most programming options. Desktop mode allows programming to be done in the comfort of an office, with the module and program later snapped into place.

CircuitManager software allows you to print out all of your panel schedules, and system configuration information. In addition, PLK and CircuitManager software can store all of your data on a floppy disk.

40

SQUARE D

9/98

Page 40

Software Features (PLK/CMS) Software Feature Comparison Features

CircuitManager System Manager

PLK-101

Program panel

✔

✔

Future Version

Panel diagnostics

✔

✔

Future Version

Save programs on disk

✔

✔

Future Version

Print programs and schedules

✔

Future Version

Synchronize panel clocks

✔

Future Version

Monitor status

✔

✔

✔

Operate circuits

✔

✔

✔

Password protection

✔

✔

Multipanel systems

✔

✔

Integrate POWERLOGIC data

✔

Event Logging

✔

Alarms

✔ ✔

Custom graphics

System Requirements Operating system Operating System

PLK-101 Windows 3.1 Windows 95

RAM

Windows 95

VGA

VGA

VGA

VGA [Super VGA]

386 [486]

386 [486]

386 [486]

Pentium

4M [8M] 5M free space

4M [8M]

32M

5M free space

500M †

4M [8M] 5M free space

Hard Disk

Windows NT

Windows 95

Display Mode Model

Windows 3.1 System Windows 3.1 WindowsSystem 3.1 Windows 95 CircuitManager Manager Manager® Windows 95 Windows 95 Windows NT SMS-770 3000 (different versions) Windows 3.1 Windows 3.1

SY/LINK Card optional optional optional optional

RS-232 Port required required required required optional optional required required required required

Sound Card 3.5" Drive

Order Information Class

Type

Description

3080 3080 3080 3080 3080

PLK-101 CMS-1000 SMS-770 GFX-700 SMS-3000

POWERLINK AS Communications Software CircuitManager Software POWERLOGIC System Manager Software POWERLOGIC Interactive Graphics Module POWERLOGIC System Manager 3000 Software

SQUARE D

9/98