Summary

What is in it

Allen-Bradley user manual for the 1771-OFE Series B Analog Output Module, a four-channel block transfer module for the 1771 I/O chassis. It covers the three versions (1771-OFE1 voltage, 1771-OFE2 and 1771-OFE3 current), installation and configuration jumpers, wiring, configuration and scaling, block transfer programming for PLC-2, PLC-3 and PLC-5 processors, reading status data, calibration, troubleshooting with indicator lights, specifications and data table formats.

Its parts

  1. Overview of the Analog Output Module
  2. Module Installation
  3. Module Configuration
  4. Module Programming
  5. Module Status and Input Data
  6. Calibrating Your Output Module
  7. Diagnostics and Troubleshooting

From the manual

Key facts from this manual

Some pages are scans or cannot be read; this says only what the readable text supports. Each line names its page in the PDF.

User manual for the Allen-Bradley 1771-OFE Series B analog output module, covering the 1771-OFE1 voltage version and the 1771-OFE2 and 1771-OFE3 current versions. It explains installing, configuring, programming, calibrating and troubleshooting the four-channel module in a 1771 I/O chassis.

Read for this summary: pages 1 to 9, 11 to 25, 65 to 73 and 81 of 84.

Module type
Intelligent block transfer module that turns binary or four-digit BCD values from the processor into analog outputs p. 11
Outputs
4 individually isolated differential outputs p. 12
Voltage ranges
1771-OFE1: +1 to +5V DC, 0 to +10V DC or -10 to +10V DC, set per channel by jumpers p. 17, 69
Power
Drawn from the 1771 I/O chassis backplane; no external supply needed p. 12
Chassis and slots
Any 1771 I/O chassis; uses one I/O slot p. 6, 12
Resolution
12-bit binary, 1 part in 4095 p. 69
Current ranges
1771-OFE2: +4 to +20mA; 1771-OFE3: 0 to +50mA; both factory set p. 12, 69
Max output current
1771-OFE1: 10mA per channel in voltage mode p. 69
Isolation
1000V rms between output channels p. 69
Block transfer
Write of up to 13 words; read of 5 words for diagnostics p. 11
Wiring arm
1771-WC field wiring arm; screw torque 7-9 pound-inches (0.6-1.1Nm) p. 23, 70
Signal cable
Belden 8761 shielded twisted pair, shield grounded at the chassis end only p. 24
Indicators
Green RUN and red FLT (fault) p. 25
Environment
Operating 0 to +60°C (+32 to +140°F); humidity 5% to 95% non-condensing p. 70

What this manual walks you through

  • Choosing a slot and module group in the I/O chassis p. 17
  • Setting the last state jumpers for loss of communication p. 17, 18, 19, 20
  • Setting the voltage range jumpers on the 1771-OFE1 p. 20, 21
  • Installing the keying bands p. 21
  • Installing the module and the 1771-WC wiring arm p. 22
  • Wiring analog devices to the field wiring arm p. 23
  • Grounding the cable shield at the chassis p. 24
  • Troubleshooting with the RUN and FLT indicators p. 65, 66
  • Reading the five-word status block transfer p. 66, 67
  • Block transfer with Mini-PLC-2 and PLC-2/20 processors using multiple GET instructions p. 71, 72, 73

Good to know

  • Do not insert or remove the module while system power is on; it can damage the module circuitry. p. 16
  • The module is open equipment and must be mounted in an enclosure during operation. p. 16
  • Do not place the module in the same module group as a discrete high-density module. p. 17
  • A read block transfer for more or fewer than five words is not performed. p. 66
  • Outputs are protected against short circuits lasting no more than one minute. p. 69

Questions this manual answers

What voltage ranges does the 1771-OFE1 output?

+1 to +5V DC, 0 to +10V DC or -10 to +10V DC, chosen per channel with configuration jumpers. It ships with the jumpers in the +10V position. p. 17, 69

What do 1771-OFE outputs do when communication with the processor is lost?

Depending on the LAST STATE jumpers and rack switch 1, they go to the minimum, middle or maximum of the range or hold the last value. Modules ship with the jumpers in MID. p. 17, 18

Which wiring arm and cable does the 1771-OFE use?

The 1771-WC field wiring arm, with Belden 8761 shielded twisted-pair cable whose shield is grounded at the chassis end only. p. 23, 24

Does the 1771-OFE1 need an external power supply?

No. It takes its power through the 1771 I/O chassis backplane from the chassis power supply. p. 16

What does a steady red FLT light on the 1771-OFE mean?

The module found a fault during its power-up self-check or later. The troubleshooting chart suggests cycling power and replacing the module if necessary. p. 65, 66

The whole text · 9 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 101-10
  2. Pages 11 to 2011-20
  3. Pages 21 to 3021-30
  4. Pages 31 to 4031-40
  5. Pages 41 to 5041-50
  6. Pages 51 to 6051-60
  7. Pages 61 to 7061-70
  8. Pages 71 to 8071-80
  9. Pages 81 to 8481-84

The file

Revision and size

RevisionPublication 1771-6.5.30, November 1998
PublisherAllen-Bradley
Pages84
PDF555 KB
TextText from the PDF itself; 11 pages are scans, read by OCR, which may hold reading errors.

The first pages · 3 of 84

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 84
Page 2
Page 2of 84
Page 3
Page 3of 84