Page 1 of PLC-5 Programmable Controllers Selection Guide 1785 and 1771

Manual · Allen-Bradley

PLC-5 Programmable Controllers Selection Guide 1785 and 1771

Manual60 pagesPDF 4.2 MB

Selection guide for Allen-Bradley PLC-5 programmable controllers with 1771 and other I/O, networks, chassis, power supplies and software.

Download the PDF4.2 MB

Filed with · 1 model

Also filed with these models on the old site

Summary

What is in it

The Allen-Bradley PLC-5 selection guide for 1785 controllers and 1771 I/O. It opens with a comparison table of PLC-5 controllers by memory, I/O and ports, then steps through laying out a system and selecting I/O modules (1771, 1746, FLEX, POINT and others), network communications, controllers, chassis, power supplies and software. The 1771 section lists digital and analog module catalog numbers with their points, voltages and backplane current.

Its parts

  1. PLC-5 Comparison
  2. Introduction
  3. Select I/O Modules
  4. Select Network Communications
  5. Select Controllers
  6. Select Chassis
  7. Select Power Supplies
  8. Select Software
  9. Summary

From the manual

Key facts from this manual

Each line names its page in the PDF.

An Allen-Bradley selection guide (publication 1785-SG001B-EN-P, June 2006) for PLC-5 programmable controllers (1785) and the 1771 chassis, power supplies and I/O modules, with the networks and software that go with them. It does not list the 1771-OGC; its 1771 digital output table names the TTL modules 1771-OG and 1771-OGD. It helps the reader lay out a PLC-5 system and pick controllers, I/O modules, chassis and power supplies.

Read for this summary: pages 2 to 6, 10 to 14 and 38 to 42 of 60.

Document type
Selection guide for 1785 PLC-5 controllers with 1771 I/O, chassis, power supplies, networks and software p. 3
Minimum system
A controller and I/O modules in one 1771 chassis with a power supply; up to 512 I/O in the controller's chassis p. 4
Controller range
PLC-5/11 (1785-L11B): 8000 words, 512 I/O, up to PLC-5/80 (1785-L80B): 100,000 words, 3072 I/O p. 2
Ethernet controllers
PLC-5/20E (1785-L20E), PLC-5/40E (1785-L40E), PLC-5/80E (1785-L80E), each with 1 Ethernet port p. 2
ControlNet controllers
PLC-5/20C (1785-L20C15), PLC-5/40C (1785-L40C15), PLC-5/80C (1785-L80C15), PLC-5/46C (1785-L46C15) p. 2
TTL output modules
1771-OG: 8, 5.0...5.3V, 168 mA backplane current; 1771-OGD: 16, 5.0...5.3V, 230 mA p. 11
TTL input module
1771-IG: 8 inputs, 122 mA backplane current p. 10
DeviceNet
Needs a 1771-SDN DeviceNet Scanner Module p. 4
Memory backup
EEPROM modules 1785-ME16, 1785-ME32, 1785-ME64, 1785-CHBM; not for ControlNet PLC-5 controllers p. 38
Battery
1770-XYC for all PLC-5 programmable controllers p. 38
Chassis
1771-A1B (4 slots), 1771-A2B (8), 1771-A3B and 1771-A3B1 (12), 1771-A4B (16) p. 39
Power supplies
5V dc to the backplane, up to 8 A per supply, one or two chassis slots; can be paralleled p. 41
Power supply models
1771-P4S: 120V ac, 8 A @ +5V dc, 1 slot; 1771-P5: 24V dc, 8 A, 2 slots; 1771-P7: 16 A @ +5V dc, standalone p. 41
Chassis spacing
Mount horizontally; 153 mm (6 in.) above and below, 102 mm (4 in.) at the sides p. 40

What this manual walks you through

  • Choosing a PLC-5 controller by memory, I/O count and ports p. 2
  • Laying out controllers, I/O and networks p. 6
  • Selecting 1771 digital, analog and intelligent I/O modules p. 10, 11, 12, 13, 14
  • Backing up controller memory and estimating battery life p. 38
  • Choosing a 1771 chassis and spacing it in the enclosure p. 39, 40
  • Choosing power supplies and sizing the transformer p. 41, 42

Good to know

  • A PLC-5 controller can control only I/O modules attached directly to the same network. p. 6
  • A transformer that is too small clips the sine wave and can make the power supply shut down modules early. p. 42
  • Leave any excess enclosure space at the top, where the temperature is highest. p. 40
  • Each ac power supply signals a backplane shutdown when line voltage drops below its lower limit. p. 42

Questions this manual answers

How much backplane current does the 1771-OG TTL module draw?

168 mA; the guide lists it with 8 points at 5.0...5.3V. p. 11

Which battery does a PLC-5 controller use?

The 1770-XYC, which applies to all PLC-5 programmable controllers. p. 38

How much current can a 1771 power supply provide?

Up to 8 A per supply at 5V dc to the backplane; the standalone 1771-P7 gives 16 A @ +5V dc. p. 41

How many I/O can a PLC-5/80 handle?

3072 I/O, with 100,000 words of user memory. p. 2

What sizes do 1771 chassis come in?

1, 2, 4, 8, 12 and 16 module slots. p. 39

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. PLC-5 Selection Guide - 1785 and 17711
  2. PLC-5 Comparison2
  3. Introduction3
    1. 1785 PLC-5 Programmable Controller: The Foundation of Control Architecture3
    2. PLC-5 System Overview4
    3. Lay Out the System6
  4. Select I/O Modules9
    1. 1771 I/O Modules10
    2. 1746 I/O Modules15
    3. 1794 FLEX I/O Modules16
    4. 1797 FLEX Ex I/O Modules17
    5. 1791D CompactBlock I/O Modules18
    6. 1734 POINT I/O Modules19
    7. Additional I/O Selections20
  5. Select Network Communications21
    1. EtherNet/IP Protocol23
    2. ControlNet Network25
    3. DeviceNet Network27
    4. Serial Network28
    5. Data Highway Plus31
    6. Remote I/O32
  6. Select Controllers33
    1. Enhanced PLC-5 Controllers34
    2. Ethernet PLC-5 Controllers35
    3. ControlNet PLC-5 Controllers36
    4. Protected PLC-5 Controllers37
    5. Back Up Controller Memory38
    6. Battery Replacement and Life Estimates38
  7. Select Chassis39
  8. Select Power Supplies41
    1. Power Requirements and Transformer Sizing42
    2. Notes44
  9. Select Software45
    1. Programming Software46
    2. RSLinx Sotware47
    3. Network Configuration Software48
    4. RSLogix Emulate 5 Software49
    5. PLC-5 Controller and Training Software50
    6. ViewAnyWare Products52
  10. Summary55
1 more line, from page 60 on
  1. Back Cover60

From the PDF’s own bookmarks.

The whole text · 7 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 81-8
  2. Select I/O Modules9-20
  3. Select Network Communications21-32
  4. Select Controllers33-38
  5. Pages 39 to 4439-44
  6. Select Software45-54
  7. Pages 55 to 6055-60

The file

Revision and size

RevisionPublication 1785-SG001B-EN-P, June 2006
PublisherRockwell Automation
Pages60
PDF4.2 MB
TextText from the PDF itself; page 1 is a scan, read by OCR, which may hold reading errors.

The first pages · 3 of 60

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 60
Page 2
Page 2of 60
Page 3
Page 3of 60