Page 187
Relay and Timer Specifications
IEC Control Relays Product Overview
Bulletin No.
700-CF and 700S-CF
700-K
Type
Control Relay
Miniature Control Relay
Features
• Mechanically linked contacts • Timer and latch operations • Switch up to 690V AC and DC • 700S-CF for safety circuits
• Smallest size • Long life • Low power consumption • Switch up to 690V AC and DC
Contact Form
4…12 poles, double break
4...8 Poles Double Break
Contact Type
Cross stamp or bifurcated
Bifurcated
Contact Material
Silver, gold
Silver
Max. Current AC Resistive
20 A (relay) 10 A (adder deck)
10 A
Min. load
17V, 10 mA (Silver) 5V, 3 mA (Gold)
15V, 2 mA (700-K)
Coil Voltage
12…600V AC 9…250V DC
12…600V AC 9…250V DC
Coil Voltage Pickup
85…110% AC coils, 80…110% DC coils
85…110% AC Coils, 80…110% DC Coils
Dielectric Withstand
2.5 kV
2640V
Electric Service Life (cycles)
1.2 million at 10 A
800K at 10 A 120V AC
Certifications
CE, cULus, CCC
CE, cULus, CCC
Sockets
DIN Rail or panel mount
DIN Rail or panel mount
Page
188
212
Electrical
Reference
Rockwell Automation Publication 700-TD552C-EN-P - October 2018
187
Page 188
Relay and Timer Specifications
700-CF Control Relay • IEC industrial relays • Mechanically linked contact performance per IEC 60947-5-1 • Gold plated, bifurcated version for low level switching applications • Master control relay version rated 15 A (AC-15) • Solid-state and pneumatic timing modules • 4-…10 Poles
4-Pole AC Coil Voltage (Ratings for 700-CF Only) AC-12
AC-15
Ith [A] 40 °C
20
Contacts
Ie [A] 60 °C
24/48V
20
Gold Plated Bifurcated Contacts(2)
Master Contacts(2)
N.O. N.C. Cat. No.
Cat. No.
Cat. No.
2
2
700-CF220⊗
700-CFB220⊗
700-CFM220⊗
3
1
700-CF310⊗
700-CFB310⊗
700-CFM310⊗
4
0
700-CF400⊗
700-CFB400⊗
700-CFM400⊗
0
4
700-CF040⊗
700-CFB040⊗, Standard Contacts(1)
Connection Diagrams 120V
10
240V
10
10
400V
500V
6
2.5
600V
690V
1
1
(1) For spring clamp terminals, insert R after 700-C. Example: Cat. No. 700-CRF220D. (2) All Cat. Nos. are factory-stocked.
⊗ AC Coil Voltage Code The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: Cat. No. 700-CF220⊗ becomes Cat. No. 700-CF220D for 120V, 60 Hz. [V]
12
24
32
36
42
48
100
100... 110
110
120
127
200
200... 220
208
208... 240
220... 230
230
230... 240
240
50 Hz
R
K
V
W
X
Y
KP, D
P
S
KG
L, - F, VA
T
60 Hz
Q
J, V, X, KP, D, - KG
H
L, - - A
50/60 Hz, KJ, - - KY
KP, KD, - KG
KL, - KL
KF, KA
[V]
277
347
380
380... 400
400
400... 415
440
480
500
550
600
50 Hz, - - N, G
B, M
C, 60 Hz
T
I
E, - - N
B, - C
50/60 Hz, - - - KN, KB, - - - 188
Rockwell Automation Publication 700-TD552C-EN-P - October 2018
Page 189
Relay and Timer Specifications
4-Pole DC Coil Voltage (Ratings for 700-CF Only) AC-12
AC-15 Connection Diagrams
Ie [A]
Ith[A] 40 °C
Contacts
60 °C
24/48V
120V
240V
400V
500V
600V
690V
Standard Contacts(1)
Gold Plated Bifurcated Contacts(2)
Master Contacts(2) Cat. No.
N.O.
N.C.
Cat. No.
Cat. No.
2
2
700-CF220
700-CFB220⊗ 700-CFM220⊗
⊗
20
20
10
10
10
6
2.5
1
1
3
1
700-CF310⊗ 700-CFB310⊗ 700-CFM310⊗
4
0
700-CF400⊗ 700-CFB400⊗ 700-CFM400⊗
(1) For spring clamp terminals, insert R after 700-C. Example: Cat. No. 700-CRF220D. (2) All Cat. Nos. are factory-stocked.
⊗ DC Coil Voltage Code The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. example: Cat. No. 700-CF220⊗ becomes Cat. No. 700-CF220EJ for 24V DC, electronic with diode. [V]
9
12
24
36
48
48... 72
60
64
72
80
110
110... 115 125
125
220
220... 250
230
250
Electronic with diode, EQ
EJ
EW, EY, - - - - ED, - - EA, - Electronic with diode/ Quick Pick-up, - QJ, - - - - - - - - - - - - - - Rockwell Automation Publication 700-TD552C-EN-P - October 2018
189
Page 190
Relay and Timer Specifications
6- and 8-pole Relays Control Relays with Overlapping Side-Mounted Contacts AC-12
AC-15
Ith [A]
Ie [A] 40 60 24/ °C °C 48V
Main Relay
Side Contacts
190
20
10
20
10
10
6
Left Aux. 120 V
10
6
240 V
10
5
400 V
6
3
500 V
2.5
1.6
600 V
1
1
Relay Arrangement
Right Aux.
690 V
Contacts
Overlapping SideMounted Contacts
Cat. No.
N.O. N.C. N.O.
N.C.
4
0
1
1
700-CFZ1510⊗
3
1
1
1
700-CFZ1420⊗
2
2
1
1
700-CFZ1330⊗
4
0
2
2
700-CFZ2620⊗
3
1
2
2
700-CFZ2530⊗
2
2
2
2
700-CFZ2440⊗
1
1
Rockwell Automation Publication 700-TD552C-EN-P - October 2018
Page 191
Relay and Timer Specifications
Control Relays with Standard Side-mounted Contacts AC-12
AC-15
Ith [A]
Ie [A]
Left Aux.
40 60 24/ °C °C 48V
Main Relay
20
20
Side Contacts 10
10
Relay Arrangement
Contacts
Right Aux.
120V 240V 400V 500V 600V 690V
10
10
6
10
6
6
5
2.5
3
1
1.6
1
1
1
Standard SideMounted Contacts
Cat. No. (1)
N.O.
N.C. N.O.
N.C.
4
0
1
1
700CFZ0510⊗
3
1
1
1
700CFZ0420⊗
2
2
1
1
700CFZ0330⊗
4
0
2
2
700CFZ0620⊗
3
1
2
2
700CFZ0530⊗
2
2
2
2
700CFZ0440⊗
(1) All Cat. Nos. are factory stocked.
⊗ AC Coil Voltage Code The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: Cat. No. 700-CFZ051⊗ becomes Cat. No. 700-CFZ0510F. [V]
12
24
32
36
42
48
100
100... 110
110
120
127
200
200... 220
208
208... 240
220... 230
230
230... 240
240
50 Hz
R
K
V
W
X
Y
KP, D
P
S
KG
L, - F, VA
T
60 Hz
Q
J, V, X, KP, D, - KG
H
L, - - A
50/60 Hz, KJ, - - KY
KP, KD, - KG
KL, - KL
KF, KA
[V]
277
347
380
380... 400
400
400... 415
440
480
500
550
600
50 Hz, - - N, G
B, M
C, 60 Hz
T
I
E, - - N
B, - C
50/60 Hz, - - - KN, KB, - - - Rockwell Automation Publication 700-TD552C-EN-P - October 2018
191
Page 192
Relay and Timer Specifications
Assignment of Contacts Device Combinations in Accordance with IEC 60947-1 / -4-1 Auxiliary Contact Blocks Circuit Diagram
Control Relays 700-CF (AC and DC Control) Control
700-CF⊗220
700-CF⊗310
700-CF⊗400
AC/DC
22E + 02E = 24Y
31E + 02E = 33Y
40E + 02E = 42Y
AC/DC
22E + 11E = 33Y
31E + 11E = 42Y
40E + 11E = 51Y
AC/DC
22E + 20E = 42Y
31E + 20E = 51Y
40E + 20E = 60Y
AC/DC
22E + 22E = 44Y
31E + 22E = 53Y
40E + 22E = 62Y
AC/DC
22E + 31E = 53Y
31E + 31E = 62Y
40E + 31E = 71Y
AC/DC
22E + 40E = 62Y
31E + 40E = 71Y
40E + 40E = 80Y
AC/DC
22E + L22E = L44Y
31E + L22E = L53Y
40E + L22E = L62Y
Front Mounting (1) 51 61
100-FA02 52 62 53 61
100-FA11 54 62 53 63
100-FA20 54 64 53 61 71 83
100-FA22 54 62 72 84 53 61 73 83
100-FA31 54 62 74 84
100-FA40
53 63 73 83 54 64 74 84 53 61 75 87
100-FAL22 54 62 76 88
(1) Control relay and auxiliary contact block AC/DC max. 4 N. C.
192
Rockwell Automation Publication 700-TD552C-EN-P - October 2018
Page 193
Relay and Timer Specifications
Auxiliary Contacts Photo
Description
N.O.
Auxiliary Contact Blocks for Front Mounting§ 2- and 4-pole Quick and easy mounting without tools Electronic-compatible contacts down to 17V, 5 mA Mechanically linked performance between N.O. and N.C. poles and to the main relay poles (except for L types) Models with equal function with several terminal numbering choices 1L = Late break N.C./early make N.O. Bifurcated version for switching down to 5V, 3 mA
N.C.
Connection Diagrams
For Use With
Standard Contacts (1)
Bifurcated Contacts
Cat. No.
Cat. No.
0
2
100-FA02
100-FAB02
1
1
100-FA11
100-FAB11
2
0
100-FA20
100-FAB20
1L
1L
100-FAL11, 0
4
100-FA04
100-FAB04
1
3
100-FA13
100-FAB13
100-FA22
100-FAB22
700-CF
2
2
3
1
100-FA31
100-FAB31
4
0
100-FA40
100-FAB40
1+1L
1+1L
100-FAL22, (1) For spring clamp terminals, insert CR after 100-. Example: Cat. No. 100-CRFA02.
Photo
Description
Auxiliary Contact Blocks for Side Mounting without Sequence Terminal Designations§ 1- and 2-pole Two-way numbering for right or left mounting on the contactor Quick and easy mounting without tools Electronic-compatible contacts down to 17V, 10 mA Mirror contact performance to the main relay poles 1L = Late break N.C./early make N.O.
N.O.
N.C.
0
1
100-SA01
1
0
100-SA10
0
2
100-SA02
1
1
100-SA11
2
0
100-SA20
For Use With
Cat. No.
700-CF
1L
IMPORTANT
Connection Diagrams
1L
100-SAL11
For maximum number of contacts, see the following tables.
Rockwell Automation Publication 700-TD552C-EN-P - October 2018
193
Page 194
Relay and Timer Specifications
700-CF (AC electronic coils), vertical mounting, 60 °C(1) Cat. No. 700…
Max. N.O. Side Aux.
Max. N.C. Side Aux.
Max. N.O. Front Aux.
Max. N.C. Front Aux.
Max. N.O. Front + Side Aux.
Max. N.C. Front + Side Aux.
Max. N.O. + N.C. Front + Side Aux.
CF400 CF310 CF220 CF040
2 2 4 2
4 4 (2) 4 (2) 2
4 4 4 4
4 4(3) 2 0
6 6 8 6
7 5 5 2
8 8 8 6
(1) For other operating conditions, please contact your local Rockwell Automation sales office or Allen-Bradley distributor. (2) With no front auxiliary contacts installed. Otherwise 3 N.C. Maximum (3) With no side auxiliary contacts installed. Otherwise 3 N.C. Maximum
700-CF (DC conventional coils), vertical mounting, 60 °C(1) Cat. No. 700…
Max. N.O. Side Aux.
Max. N.C. Side Aux.
Max. N.O. Front Aux.
Max. N.C. Front Aux.
Max. N.O. Front + Side Aux.
Max. N.C. Front + Side Aux.
Max. N.O. + N.C. Front + Side Aux.
CF400 CF310 CF220
2 2 2
2 2 2
4 4 4
4 (2) 4 (2) 2
6 6 6
5 5 4
8 8 8
(1) For other operating conditions, please contact your local Rockwell Automation sales office or Allen-Bradley distributor. (2) With no side auxiliary contacts installed. Otherwise 3 N.C. Maximum
194
Rockwell Automation Publication 700-TD552C-EN-P - October 2018
Page 195
Relay and Timer Specifications
Control Modules Photo
Description
Connection Diagrams
Pneumatic Timing Modules(1) ON-Delay Pneumatic timing element contacts switch after the delay time. The contacts on the main control relay continue to operate without delay.
Reset Time
Repeat Accuracy
25…90 ms for AC Coils +/-10%
Pneumatic Timing Modules OFF-Delay Pneumatic timing element contacts switch after the delay time. The contacts on the main control relay continue to operate without delay.
47…85 ms for DC coils
Delay
For Use With
0.3…30 s
100-FPTA30
1.8…180 s
100-FPTA180
0.3…30 s
700-CF all (1)
1.8…180 s
0.1…3 s 1…30 s
Electronic Timing Modules, On-Delay Delay of the control relay coil assembly. The control relay is energized at the end of the delay time.
10…180 s 100 ms
+/-1%
10…180 s 0.3…3 s 1…30 s 10…180 s 100 ms
+/-1%
700-CF 110…240V AC 110…250V DC conventional coils
10…180 s
100-ETA3 100-ETA30 100-ETA180 100-ETAZJ3
700-CF 24…48V DC coils
700-CF 110…240V AC coils
0.3…3 s 1…30 s
100-FPTB30
100-FPTB180
0.1…3 s 1…30 s
Electronic Timing Modules, Off-Delay Delay of the control relay coil assembly. After interruption of the control signal, the control relay is deenergized at the end of the delay time.
Cat. No.
100-ETAZJ30 100-ETAZJ180 100-ETB3 100-ETB30 100-ETB180 100-ETBKJ3
700-CF 24V AC coils
100-ETBKJ30 100-ETBKJ180
(1) On-Delay modules cannot be used with side-mounted auxiliary contacts on DC coil relays.
Photo
Connection Diagrams
Description
Mechanical Latch Following relay latching, the relay coil is immediately de-energized (off) by the N.C. auxiliary contact (65-66). Electrical or manual release 1 N.O. + 1 N.C. auxiliary contacts
Rockwell Automation Publication 700-TD552C-EN-P - October 2018
For Use With
Cat. No.
700-CF with AC coils
100-FL11⊗
195