Dimensions - 700-CF... Relays Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.
Mounting Position AC and DC Control Relay with DC Electronic Coil
(1)
Front View
Side View
(1) May be mounted to 35 mm EN 50 022 DIN Rail.
DC Control Relay
Side View
Front View
AC and DC Control Relays with 12V or 24V DC Electronic Coil Type a b 45 (1-25/32)
700-CF, -CFB, -CFM c 81 (3-3/16)
c1 80.5 (3-11/64)
Ød c2 75.5 (3-3/32)
6 (1/4)
d1
2 screws 4.5 (3/16)
d2 60 (2-23/64)
35 (1-25/64)
DC Control Relays with 48...72V, 110...125V or 220...250V DC Electronic Coil Type a b c
45 (1-25/32)
700-CF, -CFB, -CFM
105 (4-1/8)
c1 80.5 (3-11/64)
Ød c2 75.5 (3-3/32)
6 (1/4)
d1
2 screws 4.5 (3/16)
d2 60 (2-23/64)
35 (1-25/64)
DC Control Relays with Conventional Coil Type 700-CF, -CFB, -CFM a b 45 (1-25/32)
c 81 (3-3/16)
c1 106.5 (4-3/16)
Ød c2 101.5 (4)
6 (1/4)
Rockwell Automation Publication 700-TD552C-EN-P - October 2018
2 screws 4.5 (3/16)
d1 d2 60 (2-23/64)
35 (1-25/64)
205
Page 206
Relay and Timer Specifications
Accessories - 700-CF Relays Relay with
206
AC Control Relay
DC Control Relay mm
(inches)
mm
(inches)
Auxiliary Contact for Front Mounting
2- or 4-pole c/c1 + 39
(c/c1 + 1 – 37/64)
c/c1 + 39 c/c1 + 1 – 37/64)
Auxiliary Contact for Side Mounting
1- or 2-pole a+9
(a + 23/64)
a+9
(a + 23/64)
Pneumatic Timing Module, c/c1 + 58
(c/c1 + 2 – 23/64), - Solid-state Timing Module on coil terminal side b + 24
(b + 15/16)
b + 24
(b + 15/16)
Mechanical Latching, c/c1 + 61
(c/c1 + 2 – 31/64), - DC Interface on coil terminal side b+9
(b + 23/64), - Surge Suppressor on coil terminal side b+3
(b + 1/8)
b+3
(b + 1/8)
Labelling with:
label sheet
+0
(+0)
+0
(+0), marking tag with cover
+0
(+0)
+0
(+0), marking tag carrier for System V4/V5
+5.5
(+7/32)
+5.5
(+7/32), marking tag carrier for System Bull. 1492W
+5.5
(+7/32)
+5.5
(+7/32)
Rockwell Automation Publication 700-TD552C-EN-P - October 2018
Page 207
Relay and Timer Specifications
700S-CF Control Relays The 700S-CF Safety Control Relay provides mechanically or mirror contact performance, which are required in feedback circuits for safety applications. Bifurcated contacts are ideal for low energy feedback safety circuits where high contact reliability is required. • IEC industrial safety relay • Mechanically linked contacts as per IEC 60947-5-1 • Third party certification SUVA • Red cover and mechanically linked contact symbol on front face • Gold plated, bifurcated version for low level switching applications • Permanently fixed front mounted auxiliary contact block
Type CF and CFB Safety Control Relays, 8-Pole AC Coil Voltage (Ratings for 700S-CF Only) AC-12
AC-15
Contacts Connection Diagrams
Ith [A]
Ie [A]
Main Contacts 40 60 24/ °C °C 48V
120 V
240 V
400 V
500 V
600 V
690 V
20
10
10
6
2.5
1
1
20
10
Auxiliary Contacts
Standard Contacts (Main) Gold-Plated Bifurcated (Front) Cat. No.
Gold-Plated Bifurcated, All Contacts Cat. No. (1)
N.O.
N.C.
4
4
700SCF440⊗BC
700SCFB440⊗C
5
3
700SCF530⊗BC
700SCFB530⊗C
6
2
700SCF620⊗BC
700SCFB620⊗C
Main Contacts
Adder Deck Contacts
10
6
6
6
5
3
1.6
1
1
(1) Ratings for 700S-CFB are on Specifications
⊗ AC Coil Voltage Code The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: Cat. No. 700S-CF440⊗BC becomes Cat. No. 700S-CF440DBC for 120V, 60 Hz. [V]
12
24
32
36
42
48
100
100... 110
110
120
127
200
200... 220
208
208... 240
220... 230
50 Hz
R
K
V
W
X
Y
KP, D
P
S
KG
L, - F
60 Hz
Q
J, V, X, KP, D, - KG
H
L, 50/60, KJ, - - KY
KP, KD, - KG
KL, - KL
Hz [V]
230
230... 240
240
277
347
380
380... 400
400
400... 415
440
480
500
550
600
50 Hz, VA
T, - - N, G
B, M
C, 60 Hz, - A
T
I
E, - - N
B, - C
50/60 Hz KF, KA, - - - KN, KB, - - - Rockwell Automation Publication 700-TD552C-EN-P - October 2018
207
Page 208
Relay and Timer Specifications
Type CF and CFB Safety Control Relays, 8-Pole DC Coil Voltage (Ratings for 700S-CF Only) AC-12
AC-15
Ith [A]
Ie [A]
Contacts Connection Diagrams
Main Contacts
Auxiliary Contacts
Gold Plated Bifurcated All Contacts Cat. No.(1)
40 °C
60 °C
24/48V
120V
240V
400V
500V
600V
690V
No. of N.O. Contacts
No. of N.C. Contacts
20
20
10
10
10
6
2.5
1
1
4
4
700SCF440⊗BC
700SCFB440⊗C
5
3
700SCF530⊗BC
700SCFB530⊗C
6
2
700SCF620⊗BC
700SCFB620⊗C
Main Contacts
Adder Deck Contacts
Standard Contacts (Main) GoldPlated Bifurcated (Front) Cat. No.
10
6
6
6
5
3
1.6
1
1
(1) Ratings for 700S-CFB are on Specifications
⊗ DC Coil Voltage Code The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: Cat. No. 700S-CFB440⊗C becomes Cat. No. 700S-CFB440EJC for 24V DC, electronic with diode. [V]
9
12
24
36
48
48... 72
60
64
72
80
110
110... 115 125
125
220
220... 250
230
250
Electronic with diode, EQ
EJ
EW, EY, - - - - ED, - - EA, - Electronic with diode/ Quick Pick-up, - QJ, - - - - - - - - - - - - - - 208
Rockwell Automation Publication 700-TD552C-EN-P - October 2018
Page 209
Relay and Timer Specifications
Assignment of Contacts Safety Control Relays with Front-mount Auxiliary Contacts, 8-Pole AC or DC Coil Voltage
A1
53 61 71 81
53 61 71 83
53 61 73 83
54 62 72 82
54 62 72 84
54 62 74 84
A1
13 21 33 43
K1
13 21 33 43
K1 A2
13 21 33 43
A2
14 22 34 44
K1 A2
14 22 34 44
700S-CF440… 700S-CFB440…
A1
14 22 34 44
700S-CF530… 700S-CFB530…
700S-CF620… 700S-CFB620…
Specifications - 700S-CF Relays For more 700S-CF Specifications, see Specifications - 700-CF..., 700S-CF Relays on page 200.
Mechanical Life
Cat. No. 700S-CF
Aux. Contact (Front-mounted)
[Mil]
15
15
Electrical Life
AC-15 (240V, 3 A)
[Mil]
1.5
1.5
Weight
AC Coil
[g]
390, 2 x A4
2 x A4
Terminal Cross-Sections Terminal Type Terminal Size per IEC 947-1 1 Conductor
[mm2]
1.5…6
0.5…2.5
2 Conductor
[mm2]
1.5…6
0.75…2.5
Max. Wire Size per UL/CSA
[AWG]
16…10
18…14
Tightening Torque
[lb•in]
13.3…22
8.9…13.3
Tightening Torque
[N•m]
1.5…2.5
1…1.5
Solid/ Stranded (1)
Standards Compliance
Certifications
UL 508, CSA C22.2 No. 14, EN/IEC 60947-1, -5-1, Meets the material restrictions for European Directive 2002/95/EC - EU-RoHS cULus Listed (File No. E14840, Guide NKCR/NKCR7), CE Marked, CCC Certified
(1) For 16 or more strands, end ferrule is required
Rockwell Automation Publication 700-TD552C-EN-P - October 2018
209
Page 210
Relay and Timer Specifications
Dimensions - 700S-CF Relays Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes. c2 c1 c
AC and DC Safety Control Relays with 12V or 24V DC Electronic Coil Cat. No.
a b c c1
Ød c2 d1 d2
45
81
119.5
114.5
6
2 - 4.5
60
35
(1-25/32)
(3-3/16)
(4-3/4)
(4-43/64)
(1/4)
(2 - 3/16)
(2-23/64)
(1-25/64)
700S-CF
DC Safety Control Relays with 48...72V, 110...125V or 220...250V DC Electronic Coil Cat. No.
a b c c1
Ød c2 d1 d2
45
105
119.5
114.5
6
2 - 4.5
60
35
(1-25/32)
(4-1/8)
(4-3/4)
(4-43/64)
(1/4)
(2 - 3/16)
(2-23/64)
(1-25/64)
700S-CF
DC Safety Control Relays with Conventional Coil Cat. No.
a b c c1
Ød c2 d1 d2
45
81
145.5
140.5
6
2 - 4.5
60
35
(1-25/32)
(3-3/16)
(5-49/64)
(5-37/64)
(1/4)
(2 - 3/16)
(2-23/64)
(1-25/64)
700S-CF
Accessories - 700S-CF Relays Safety Control Relays with Auxiliary contact block for side mounting 1- or 2-pole Electronic Timing Module on coil terminal side Interface Module on coil terminal side Surge Suppressor on coil terminal side Labeling with label sheet Marking tag sheet with clear cover Marking tag adapter for System Bul. 1492W
Mounting Position AC and DC E Safety Control Relays
Front View
210
Side View
DC Safety Control Relays
Front View
Side View
Rockwell Automation Publication 700-TD552C-EN-P - October 2018 mm
[in.] a+9 b + 24 b+9 b+3 +0 +0 + 5.5
(a + 23/64) (b + 15/16) (b + 23/64) (b + 1/8) (+ 0) (+ 0) (+ 7/32)
Page 211
Relay and Timer Specifications
Safety Relay Circuit With 5 Safety Outputs • Use for E-stop control. E-stop will work properly if any one fault occurs (a fault could be one welded contact or one undesired open connection such as a loose wire). • High output switching capability and long contact life. • Circuit complies with EN 954 categories 1, 2, 3, 4. • Helps prevent restart of the 5 safety outputs if there is a single fault anywhere in the system. • Use (3) 700S-CF relays and this diagram to construct the circuit Basic Circuit (1) Output Circuit (3 Relays, 9 Terminal Blocks)
Start
Push To Stop Pull To Reset
Included in factory wired units
LOAD 1 (5) Output Circuit (3 Relays, 17 Terminal Blocks) LOAD 2 LOAD 3 LOAD 4 LOAD 5
* Numbers shown are the line numbers where the contacts for this relay appear. Contact your local Rockwell Automation sales office or Allen-Bradley distributor for availability.
Rockwell Automation Publication 700-TD552C-EN-P - October 2018
211
Page 212
Relay and Timer Specifications
700-K Miniature Control Relays • IEC compact industrial relay • IP2X Finger Protection • Bifurcated contacts for low-level signals • Optional integrated coil protection diode
4-Pole AC or DC Coil Voltage AC-12
AC-15 (B600)
Ith [A]
Ie [A]
40 °C
10
60 °C
6
Contacts Pkg. Qty.(2)
Connection Diagrams
24/48V
3
120V
3
240V
400V
2
500V
1
1
600V
0.6
690V
Cat. No.
N.O.
N.C.
4
0
1
700-K40E-⊗
3
1
1
700-K31Z-⊗
2
2
1
700-K22Z-⊗
1
700-KL22Z-⊗
0.6
1+1L (1) 1+1L (1) 1L = Late Break N.C. / Early Make N.O. (2) May be ordered in package quantities of 20. Add letter M to the end of the cat. no. Example: 700-K40E-ZJM.
⊗ Coil Voltage Codes The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: 230V, 50/60 Hz: Cat. No. 700K40E-⊗ becomes Cat. No. 700-K40E-KF. For other voltages, consult your local Rockwell Automation sales office or Allen-Bradley distributor. For Screw Type Terminal Versions [V]
12
24
110
120
125
220
230
240
250
400
440
480
525
600
AC, 50 Hz, - D, - - - - - - B, VC, AC, 60 Hz, - - D, - - - - - - B, VC
AC, 50/60 Hz, KJ, - - - KF
KA, KN, - - - ZQ
ZJ
ZD, ZS
ZA, - ZT, - - - - - DJ, - - - - - - - - - - - Standard Standard diode
DC
For Spring Clamp Type Terminal Versions AC, 50 Hz, - D, - - - - - - - - - - AC, 60 Hz, - - D, - - - - - - - - - AC, 50/60 Hz, KJ, - - - KF, - - - - - - - ZJ
ZD, - - - - - - - - - - - DJ, - - - - - - - - - - - Standard Standard diode
212
DC
Rockwell Automation Publication 700-TD552C-EN-P - October 2018
Page 213
Relay and Timer Specifications
Assignment of Contacts Device Combinations in Accordance with IEC 60947-1 / -4-1 Table valid for: AC / DC = 0.85…1.1 x Us, Tamb. = -25 °C…+60 °C, normal position (horizontal rail mounting). Also valid for 700-KR relays and 100-KR auxiliary contacts. (3) Auxiliary Contact Blocks Cat. No.
Circuit Diagram
Control Relays 700-K (AC and DC Control) Control
700-K22Z-
700-K31Z-
700-K40E-
700-KL22Z-
A1 13 43 21 31
A1 13 33 43 21
A1 13 23 33 43
A1 13 47 21 35
A2 14 44 22 32
A2 14 34 44 22
A2 14 24 34 44
A2 14 48 22 36
AC/DC, 31Z + 02E = 33Y (1)
40E + 02E = 42Y, AC/DC
22Z + 11E = 33Y
31Z + 11E = 42Y
40E + 11E = 51Y
L22Z + 11E = L33Y
AC/DC
22Z + 20E = 42Y
31Z + 20E = 51Y
40E + 20E = 60Y
L22Z + 20E = L42Y
AC/DC, - 40E + 04E = 44Y (1), AC/DC, 31Z + 13E = 44Y (1)
40E + 13E = 53Y, AC/DC, 31Z + 22Z = 53Y (1)
40E + 22Z = 62Y, AC/DC, - 40E + 31Z = 71Y (2), AC/DC
22Z + 40E = 62Y
31Z + 40E = 71Y
40E + 40E = 80Y
L22Z + 40E = L62Y
Front Mounting 51 61
100-KFA02E 52 62 53 61
100-KFA11E 54 62 53 63
100-KFA20E 54 64 51 61 71 81
100-KFA04E 52 62 72 82 53 61 71 81
100-KFA13E 54 62 72 82 53 83 61 71
100-KFA22Z 54 84 62 72 53 73 83 61
100-KFA31Z 54 74 84 62 53 63 73 83
100-KFA40E 54 64 74 84
(1) Tamb. max. +40 °C (2) Tamb. max. +40 °C and only allowed for coil voltage 24V DC or 230V AC (3) For other operating limits, please contact our technical consultant.
Rockwell Automation Publication 700-TD552C-EN-P - October 2018
213