Page 205

Relay and Timer Specifications

Dimensions - 700-CF... Relays Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.

Mounting Position AC and DC Control Relay with DC Electronic Coil

(1)

Front View

Side View

(1) May be mounted to 35 mm EN 50 022 DIN Rail.

DC Control Relay

Side View

Front View

AC and DC Control Relays with 12V or 24V DC Electronic Coil Type a b 45 (1-25/32)

700-CF, -CFB, -CFM c 81 (3-3/16)

c1 80.5 (3-11/64)

Ød c2 75.5 (3-3/32)

6 (1/4)

d1

2 screws 4.5 (3/16)

d2 60 (2-23/64)

35 (1-25/64)

DC Control Relays with 48...72V, 110...125V or 220...250V DC Electronic Coil Type a b c

45 (1-25/32)

700-CF, -CFB, -CFM

105 (4-1/8)

c1 80.5 (3-11/64)

Ød c2 75.5 (3-3/32)

6 (1/4)

d1

2 screws 4.5 (3/16)

d2 60 (2-23/64)

35 (1-25/64)

DC Control Relays with Conventional Coil Type 700-CF, -CFB, -CFM a b 45 (1-25/32)

c 81 (3-3/16)

c1 106.5 (4-3/16)

Ød c2 101.5 (4)

6 (1/4)

Rockwell Automation Publication 700-TD552C-EN-P - October 2018

2 screws 4.5 (3/16)

d1 d2 60 (2-23/64)

35 (1-25/64)

205

Page 206

Relay and Timer Specifications

Accessories - 700-CF Relays Relay with

206

AC Control Relay

DC Control Relay mm

(inches)

mm

(inches)

Auxiliary Contact for Front Mounting

2- or 4-pole c/c1 + 39

(c/c1 + 1 – 37/64)

c/c1 + 39 c/c1 + 1 – 37/64)

Auxiliary Contact for Side Mounting

1- or 2-pole a+9

(a + 23/64)

a+9

(a + 23/64)

Pneumatic Timing Module, c/c1 + 58

(c/c1 + 2 – 23/64), - Solid-state Timing Module on coil terminal side b + 24

(b + 15/16)

b + 24

(b + 15/16)

Mechanical Latching, c/c1 + 61

(c/c1 + 2 – 31/64), - DC Interface on coil terminal side b+9

(b + 23/64), - Surge Suppressor on coil terminal side b+3

(b + 1/8)

b+3

(b + 1/8)

Labelling with:

label sheet

+0

(+0)

+0

(+0), marking tag with cover

+0

(+0)

+0

(+0), marking tag carrier for System V4/V5

+5.5

(+7/32)

+5.5

(+7/32), marking tag carrier for System Bull. 1492W

+5.5

(+7/32)

+5.5

(+7/32)

Rockwell Automation Publication 700-TD552C-EN-P - October 2018

Page 207

Relay and Timer Specifications

700S-CF Control Relays The 700S-CF Safety Control Relay provides mechanically or mirror contact performance, which are required in feedback circuits for safety applications. Bifurcated contacts are ideal for low energy feedback safety circuits where high contact reliability is required. • IEC industrial safety relay • Mechanically linked contacts as per IEC 60947-5-1 • Third party certification SUVA • Red cover and mechanically linked contact symbol on front face • Gold plated, bifurcated version for low level switching applications • Permanently fixed front mounted auxiliary contact block

Type CF and CFB Safety Control Relays, 8-Pole AC Coil Voltage (Ratings for 700S-CF Only) AC-12

AC-15

Contacts Connection Diagrams

Ith [A]

Ie [A]

Main Contacts 40 60 24/ °C °C 48V

120 V

240 V

400 V

500 V

600 V

690 V

20

10

10

6

2.5

1

1

20

10

Auxiliary Contacts

Standard Contacts (Main) Gold-Plated Bifurcated (Front) Cat. No.

Gold-Plated Bifurcated, All Contacts Cat. No. (1)

N.O.

N.C.

4

4

700SCF440⊗BC

700SCFB440⊗C

5

3

700SCF530⊗BC

700SCFB530⊗C

6

2

700SCF620⊗BC

700SCFB620⊗C

Main Contacts

Adder Deck Contacts

10

6

6

6

5

3

1.6

1

1

(1) Ratings for 700S-CFB are on Specifications

⊗ AC Coil Voltage Code The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: Cat. No. 700S-CF440⊗BC becomes Cat. No. 700S-CF440DBC for 120V, 60 Hz. [V]

12

24

32

36

42

48

100

100... 110

110

120

127

200

200... 220

208

208... 240

220... 230

50 Hz

R

K

V

W

X

Y

KP, D

P

S

KG

L, - F

60 Hz

Q

J, V, X, KP, D, - KG

H

L, 50/60, KJ, - - KY

KP, KD, - KG

KL, - KL

Hz [V]

230

230... 240

240

277

347

380

380... 400

400

400... 415

440

480

500

550

600

50 Hz, VA

T, - - N, G

B, M

C, 60 Hz, - A

T

I

E, - - N

B, - C

50/60 Hz KF, KA, - - - KN, KB, - - - Rockwell Automation Publication 700-TD552C-EN-P - October 2018

207

Page 208

Relay and Timer Specifications

Type CF and CFB Safety Control Relays, 8-Pole DC Coil Voltage (Ratings for 700S-CF Only) AC-12

AC-15

Ith [A]

Ie [A]

Contacts Connection Diagrams

Main Contacts

Auxiliary Contacts

Gold Plated Bifurcated All Contacts Cat. No.(1)

40 °C

60 °C

24/48V

120V

240V

400V

500V

600V

690V

No. of N.O. Contacts

No. of N.C. Contacts

20

20

10

10

10

6

2.5

1

1

4

4

700SCF440⊗BC

700SCFB440⊗C

5

3

700SCF530⊗BC

700SCFB530⊗C

6

2

700SCF620⊗BC

700SCFB620⊗C

Main Contacts

Adder Deck Contacts

Standard Contacts (Main) GoldPlated Bifurcated (Front) Cat. No.

10

6

6

6

5

3

1.6

1

1

(1) Ratings for 700S-CFB are on Specifications

⊗ DC Coil Voltage Code The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: Cat. No. 700S-CFB440⊗C becomes Cat. No. 700S-CFB440EJC for 24V DC, electronic with diode. [V]

9

12

24

36

48

48... 72

60

64

72

80

110

110... 115 125

125

220

220... 250

230

250

Electronic with diode, EQ

EJ

EW, EY, - - - - ED, - - EA, - Electronic with diode/ Quick Pick-up, - QJ, - - - - - - - - - - - - - - 208

Rockwell Automation Publication 700-TD552C-EN-P - October 2018

Page 209

Relay and Timer Specifications

Assignment of Contacts Safety Control Relays with Front-mount Auxiliary Contacts, 8-Pole AC or DC Coil Voltage

A1

53 61 71 81

53 61 71 83

53 61 73 83

54 62 72 82

54 62 72 84

54 62 74 84

A1

13 21 33 43

K1

13 21 33 43

K1 A2

13 21 33 43

A2

14 22 34 44

K1 A2

14 22 34 44

700S-CF440… 700S-CFB440…

A1

14 22 34 44

700S-CF530… 700S-CFB530…

700S-CF620… 700S-CFB620…

Specifications - 700S-CF Relays For more 700S-CF Specifications, see Specifications - 700-CF..., 700S-CF Relays on page 200.

Mechanical Life

Cat. No. 700S-CF

Aux. Contact (Front-mounted)

[Mil]

15

15

Electrical Life

AC-15 (240V, 3 A)

[Mil]

1.5

1.5

Weight

AC Coil

[g]

390, 2 x A4

2 x A4

Terminal Cross-Sections Terminal Type Terminal Size per IEC 947-1 1 Conductor

[mm2]

1.5…6

0.5…2.5

2 Conductor

[mm2]

1.5…6

0.75…2.5

Max. Wire Size per UL/CSA

[AWG]

16…10

18…14

Tightening Torque

[lb•in]

13.3…22

8.9…13.3

Tightening Torque

[N•m]

1.5…2.5

1…1.5

Solid/ Stranded (1)

Standards Compliance

Certifications

UL 508, CSA C22.2 No. 14, EN/IEC 60947-1, -5-1, Meets the material restrictions for European Directive 2002/95/EC - EU-RoHS cULus Listed (File No. E14840, Guide NKCR/NKCR7), CE Marked, CCC Certified

(1) For 16 or more strands, end ferrule is required

Rockwell Automation Publication 700-TD552C-EN-P - October 2018

209

Page 210

Relay and Timer Specifications

Dimensions - 700S-CF Relays Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes. c2 c1 c

AC and DC Safety Control Relays with 12V or 24V DC Electronic Coil Cat. No.

a b c c1

Ød c2 d1 d2

45

81

119.5

114.5

6

2 - 4.5

60

35

(1-25/32)

(3-3/16)

(4-3/4)

(4-43/64)

(1/4)

(2 - 3/16)

(2-23/64)

(1-25/64)

700S-CF

DC Safety Control Relays with 48...72V, 110...125V or 220...250V DC Electronic Coil Cat. No.

a b c c1

Ød c2 d1 d2

45

105

119.5

114.5

6

2 - 4.5

60

35

(1-25/32)

(4-1/8)

(4-3/4)

(4-43/64)

(1/4)

(2 - 3/16)

(2-23/64)

(1-25/64)

700S-CF

DC Safety Control Relays with Conventional Coil Cat. No.

a b c c1

Ød c2 d1 d2

45

81

145.5

140.5

6

2 - 4.5

60

35

(1-25/32)

(3-3/16)

(5-49/64)

(5-37/64)

(1/4)

(2 - 3/16)

(2-23/64)

(1-25/64)

700S-CF

Accessories - 700S-CF Relays Safety Control Relays with Auxiliary contact block for side mounting 1- or 2-pole Electronic Timing Module on coil terminal side Interface Module on coil terminal side Surge Suppressor on coil terminal side Labeling with label sheet Marking tag sheet with clear cover Marking tag adapter for System Bul. 1492W

Mounting Position AC and DC E Safety Control Relays

Front View

210

Side View

DC Safety Control Relays

Front View

Side View

Rockwell Automation Publication 700-TD552C-EN-P - October 2018 mm

[in.] a+9 b + 24 b+9 b+3 +0 +0 + 5.5

(a + 23/64) (b + 15/16) (b + 23/64) (b + 1/8) (+ 0) (+ 0) (+ 7/32)

Page 211

Relay and Timer Specifications

Safety Relay Circuit With 5 Safety Outputs • Use for E-stop control. E-stop will work properly if any one fault occurs (a fault could be one welded contact or one undesired open connection such as a loose wire). • High output switching capability and long contact life. • Circuit complies with EN 954 categories 1, 2, 3, 4. • Helps prevent restart of the 5 safety outputs if there is a single fault anywhere in the system. • Use (3) 700S-CF relays and this diagram to construct the circuit Basic Circuit (1) Output Circuit (3 Relays, 9 Terminal Blocks)

Start

Push To Stop Pull To Reset

Included in factory wired units

LOAD 1 (5) Output Circuit (3 Relays, 17 Terminal Blocks) LOAD 2 LOAD 3 LOAD 4 LOAD 5

* Numbers shown are the line numbers where the contacts for this relay appear. Contact your local Rockwell Automation sales office or Allen-Bradley distributor for availability.

Rockwell Automation Publication 700-TD552C-EN-P - October 2018

211

Page 212

Relay and Timer Specifications

700-K Miniature Control Relays • IEC compact industrial relay • IP2X Finger Protection • Bifurcated contacts for low-level signals • Optional integrated coil protection diode

4-Pole AC or DC Coil Voltage AC-12

AC-15 (B600)

Ith [A]

Ie [A]

40 °C

10

60 °C

6

Contacts Pkg. Qty.(2)

Connection Diagrams

24/48V

3

120V

3

240V

400V

2

500V

1

1

600V

0.6

690V

Cat. No.

N.O.

N.C.

4

0

1

700-K40E-⊗

3

1

1

700-K31Z-⊗

2

2

1

700-K22Z-⊗

1

700-KL22Z-⊗

0.6

1+1L (1) 1+1L (1) 1L = Late Break N.C. / Early Make N.O. (2) May be ordered in package quantities of 20. Add letter M to the end of the cat. no. Example: 700-K40E-ZJM.

⊗ Coil Voltage Codes The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: 230V, 50/60 Hz: Cat. No. 700K40E-⊗ becomes Cat. No. 700-K40E-KF. For other voltages, consult your local Rockwell Automation sales office or Allen-Bradley distributor. For Screw Type Terminal Versions [V]

12

24

110

120

125

220

230

240

250

400

440

480

525

600

AC, 50 Hz, - D, - - - - - - B, VC, AC, 60 Hz, - - D, - - - - - - B, VC

AC, 50/60 Hz, KJ, - - - KF

KA, KN, - - - ZQ

ZJ

ZD, ZS

ZA, - ZT, - - - - - DJ, - - - - - - - - - - - Standard Standard diode

DC

For Spring Clamp Type Terminal Versions AC, 50 Hz, - D, - - - - - - - - - - AC, 60 Hz, - - D, - - - - - - - - - AC, 50/60 Hz, KJ, - - - KF, - - - - - - - ZJ

ZD, - - - - - - - - - - - DJ, - - - - - - - - - - - Standard Standard diode

212

DC

Rockwell Automation Publication 700-TD552C-EN-P - October 2018

Page 213

Relay and Timer Specifications

Assignment of Contacts Device Combinations in Accordance with IEC 60947-1 / -4-1 Table valid for: AC / DC = 0.85…1.1 x Us, Tamb. = -25 °C…+60 °C, normal position (horizontal rail mounting). Also valid for 700-KR relays and 100-KR auxiliary contacts. (3) Auxiliary Contact Blocks Cat. No.

Circuit Diagram

Control Relays 700-K (AC and DC Control) Control

700-K22Z-

700-K31Z-

700-K40E-

700-KL22Z-

A1 13 43 21 31

A1 13 33 43 21

A1 13 23 33 43

A1 13 47 21 35

A2 14 44 22 32

A2 14 34 44 22

A2 14 24 34 44

A2 14 48 22 36

AC/DC, 31Z + 02E = 33Y (1)

40E + 02E = 42Y, AC/DC

22Z + 11E = 33Y

31Z + 11E = 42Y

40E + 11E = 51Y

L22Z + 11E = L33Y

AC/DC

22Z + 20E = 42Y

31Z + 20E = 51Y

40E + 20E = 60Y

L22Z + 20E = L42Y

AC/DC, - 40E + 04E = 44Y (1), AC/DC, 31Z + 13E = 44Y (1)

40E + 13E = 53Y, AC/DC, 31Z + 22Z = 53Y (1)

40E + 22Z = 62Y, AC/DC, - 40E + 31Z = 71Y (2), AC/DC

22Z + 40E = 62Y

31Z + 40E = 71Y

40E + 40E = 80Y

L22Z + 40E = L62Y

Front Mounting 51 61

100-KFA02E 52 62 53 61

100-KFA11E 54 62 53 63

100-KFA20E 54 64 51 61 71 81

100-KFA04E 52 62 72 82 53 61 71 81

100-KFA13E 54 62 72 82 53 83 61 71

100-KFA22Z 54 84 62 72 53 73 83 61

100-KFA31Z 54 74 84 62 53 63 73 83

100-KFA40E 54 64 74 84

(1) Tamb. max. +40 °C (2) Tamb. max. +40 °C and only allowed for coil voltage 24V DC or 230V AC (3) For other operating limits, please contact our technical consultant.

Rockwell Automation Publication 700-TD552C-EN-P - October 2018

213