Page 39

Relay and Timer Specifications

700-HC Miniature Ice Cube Relay • 7 or 10 A contact ratings • 2PDT or 4PDT • Standard ON/OFF flag indicator • Blade-style terminals • Choice of standard silver nickel contacts, or silver nickel with gold-plated contacts for low-energy applications • Options: LED, push-to-test with manual override option • Tungsten UL Approvals

Photo

•

4-Pole: 5A @ 24V DC

•

2-Pole: 10A @ 24V DC Wiring Diagrams

Contact Rating

2PDT 2-Pole 2 Form C Contacts: 10 A = AgNi Contacts

U.S./Canada

10 A C300 R300 Low energy rating; (10V, 10 mA) 100 mW

7A = AgNiAu Gold Plated Contacts

Cat. No.

12V DC

700-HC22Z12

24V DC

700-HC22Z24

24V AC

700-HC22A24

120V AC

700-HC22A1

240V AC

700-HC22A2

6V AC

700-HC14A06

12V AC

700-HC14A12

24V AC

700-HC14A24

120V AC

700-HC14A1

240V AC

700-HC14A2

6V DC

700-HC14Z06

12V DC

700-HC14Z12

24V DC

700-HC14Z24

48V DC

700-HC14Z48

110V DC

700-HC14Z1

6V AC

700-HC24A06

12V AC

700-HC24A12

24V AC

700-HC24A24

120V AC

700-HC24A1

240V AC

700-HC24A2

6V DC

700-HC24Z06

12V DC

700-HC24Z12

24V DC

700-HC24Z24

700-HN103

48V DC

700-HC24Z48

700-HN104

110V DC

700-HC24Z1

Input

700-HN128

4PDT 4-Pole 4 Form C Contacts:

Coil Voltage

International

700-HN103 700-HN104

7A Low energy rating; (5V, 10 mA or 25V, 2 mA) 50 mW

Input

4PDT 4-Pole 4 Form C Contacts: 7A = AgNi Silver Contacts

7A C300 R300 Low energy rating; (10V, 10 mA) 100 mW

700-HN128

Rockwell Automation Publication 700-TD552C-EN-P - October 2018

39

Page 40

Relay and Timer Specifications

Accessories - 700-HC Relays Photo

Description

Pkg. Qty.

Cat. No.

Diode with LED Surge Suppressor Voltage Range: 6…24V DC used with 700-HN104 socket

10

700-ADL1

Diode with LED Surge Suppressor Voltage Range: 28…60V DC used with 700-HN104 socket

10

700-ADL2

Diode with LED Surge Suppressor Voltage Range: 110…220V DC used with 700-HN104 socket

10

700-ADL3

Varistor with LED Surge Suppressor Voltage Range: 6…24V AC used with 700-HN104 socket

10

700-AV1R

Varistor with LED Surge Suppressor Voltage Range: 110…240V AC used with 700-HN104 socket

10

700-AV3R

RC Surge Suppressor Voltage Range: 6…24V AC/DC used with 700-HN104 socket

10

700-AR1

RC Surge Suppressor Voltage Range: 110…240V AC/DC used with 700-HN104 socket

10

700-AR2

Timing Module On-Delay or One-Shot selectable voltage range: 12…24V AC/DC used with sockets that accept plug-in accessory modules. Timing Module On-Delay or One-Shot selectable voltage range: 110…125V AC used with sockets that accept plug-in accessory modules.

700-AT3

1

Timing Module On-Delay or One-Shot selectable voltage range: 230…240V AC used with sockets that accept plug-in accessory modules.

40

700-AT3A1

700-AT3A2

Screw Terminal Socket, Panel or DIN Rail Mounting; Guarded Terminal Construction.Ith = 10 A per pole. 14-blade miniature socket for use with 700-SC Relays.

10

700-HN103

Screw Terminal Socket, Panel or DIN Rail Mounting; Guarded Terminal Construction Ith = 10 A per pole. 14-blade miniature socket for use with 700-HC relays. This socket has coil and contact separation as well as the ability to plug in optional plug in modules (700-A__ accessories: LED, Surge Suppression, Timing Modules)

10

700-HN104

Screw Terminal Base Socket, Panel or DIN Rail Mounting; Open-Style Construction Ith = 10 A per pole. 14-blade miniature socket for use with 700-HC Relays.

10

700-HN128

Rockwell Automation Publication 700-TD552C-EN-P - October 2018

Page 41

Relay and Timer Specifications

Photo

Description

Pkg. Qty.

Cat. No.

DIN (#3) symmetrical hat rail 35 x 7.5 x 1 m

10

199-DR1

Retainer Clip for Cat. Nos. 700-HN103, -HN104 and -HN128 Sockets with 700-HC Relays. Secures relay in socket.(1)

10

700-HN114

Plastic Retainer and Ejection Lever For use with the 700-HN104 Sockets for 700-HC relays. Built-in ability to accept 1492 Snap-in Markers

10

700-HN124

(1) See 700-HC Miniature Square Base Relay, Socket, and Retainer Clip Reference Chart

Description

Photo

Relay Identification Snap-in Markers Snap-in markers fit on top of product covers. Squares slip into molded slot on top of product cover.

Pkg. Qty. Cat. No. 5

1492-MS5X12

5

1492-MS6X9

5

1492-MS6X12

5

1492-MS8X9

5

1492-MS8X12

100

1492-MP-Blank

Pre-Printed Identification Tags, contains 10 sheets of pre-printed and blank tags. Each sheet contains 13 sets of the markings CR…9CR, TR…9TR, M…9M, F, R, 1S, and 117 blank tags. Tags are peel-off with sticky backing for easy placement on relays.

10

700-N40

Markers, Used for terminal identification

50

700-N41

Socket and Retainer Clip Reference Relay Type

700-HC

Socket Cat. No.

Retainer Clip Cat. No.

700-HN103

700-HN114

700-HN128

700-HN114

700-HN104

700-HN114 or 700-HN124

Rockwell Automation Publication 700-TD552C-EN-P - October 2018

41

Page 42

Relay and Timer Specifications

Specifications- 700-HC Relays Attribute

700-HC Electrical Ratings

Pilot Duty Rating

(1)

NEMA C300, R300

Rated Thermal Current (Ith)

7 A and 10 A

Rated Insulation Voltage (Ui)

250V IEC – 300V UL/CSA 700-HC_4

Hp

700-HC22

Hp

Inductive 120V AC

15 A

1.5 A

1/8

15 A

1.5 A

1/3

240V AC

7.5 A

0.75 A

1/3

7.5 A

0.75 A

3/4

Contacts General-purpose

7 A, 277V AC

10 A, 277V AC

Resistive

7 A, 30V DC

10 A, 24V DC 100 mW (10V, 10 mA) - Silver Contacts 50 mW (5V, 10 mA, or 25V, 2 mA) - Gold Contacts

Min. Low Energy Permissible Load

Permissible Coil Voltage Variation

Pickup:

80…110% of nom voltage at 50 Hz 80…110% of nom voltage at 60 Hz 80…110% of nom voltage at DC

Must Dropout Voltage:

50 Hz Coil Consumption ±10%

AC Coils

20% of nom voltage at AC 10% of nom voltage at DC 60 Hz

Inrush

2.2VA

1.6VA

Sealed

1.3VA

1.1VA

DC Coils

1.0 W 20% of VA (AC)

Max. Allowable Leakage

10% of W (DC) Design Specification/Test Requirements Electrical Dielectric Withstand Voltage

Pole-to-Pole

2000V

Contact to Coil

2000V

Electrical Life (Cycles)

100 000 min Mechanical

Degree of Protection (Open Type) IEC 529

IP 20 (Guarded Terminal Sockets)

Mechanical lifecycles

20 x 106 (AC), 50 x 106 (DC)

Switching Frequency Operations

1800/HR

Coil Voltages Operating Time (ms)

See Product Selection Pickup

10

Dropout

3

Maximum Operating Rate

8 cycles/s Environmental

Temperature Altitude Insulating Material Enclosure Contact Material

Operating

–30…+55 °C (–22…+131 °F)

Storage

–55…+85 °C (–67…+185 °F) 2000 m (6560 ft) Molded High Dielectric Material Transparent Dust Cover AgNi (700-HC2), AgNi + 5 μm All (700-HC1)

Terminal Markings on Socket

In accordance with EN50 0005

Sockets

700-HN103, -HN128, -HN104

Certifications cURus Recognized (File No. E14843, Guide NRNT2/NRNT8), cULus Listed when used with 700- HN103, -HN104, and -HN128 sockets (File No. E14843, Guide NRNT/NRNT7), CE Marked, LR Certified

Standards

UL 508, CSA 22.2 No. 14, EN 61810-1

(1) See General Information on page 3

42

Rockwell Automation Publication 700-TD552C-EN-P - October 2018

Page 43

Relay and Timer Specifications

Dimensions, 700-HC Relays Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.

37.2 (1.46)

36.7 (1.44)

5.6 (0.22)

6.1 (0.24) 20.7 (0.82)

27.7 (1.09)

20.7 (0.82)

27.7 (1.09)

700-HC Relay (Two-Pole)

700-HC Relay (Four-Pole) 27.0 (1.06)

60.9 (2.40) 21.5 (0.85)

76.0 (2.99)

35.6 (1.40) 3.2 (0.13) 18.9 (0.74) 34.9 (1.37)

32.0 (1.26) 35.5 (1.40) 2.5 (0.10)

Cat. No. 700-HN104

Single Wire: 0.2 mm2…2.5 mm2 (24 AWG…14 AWG), Double Wire: 0.2 …2.5 mm2 (24 AWG…14 AWG), Qty. 2 wires Wire Type: solid or stranded, copper only, Strip Length: 7 mm (9/32 in.), Torque: 0.5 N•m (4.4 lb•in)

30.0 (1-3/16) 6.1 (15/64)

Panel Mounting

24.5 (31/32)

28.9 (1-9/64)

8

7

6

5

4

3

2

1

67.0 (2-5/8)

4.2 (5/32)

14 12

#4-40 M3

30.0 (1-11/64)

24.9 (57/64) 21.1 (53/64)

13 11

10

62.0 (2-15/64)

65.0 (2-9/16)

9

26.0 (1-1/64)

Cat. No. 700-HN103

Cat. No. 700-HN128

Single Wire: 0.2 mm2…2.5 mm2 (#24 AWG…14 AWG) Double Wire: 0.2…2 x 1.5 mm2 (24 AWG…16 AWG), Qty. 2 wires Wire Type: Solid or Stranded, Copper only Strip Length: 8 mm (5/16 in.), Torque: 0.5 N•m (4.4 lb•in)

Wire Size: 2 x 1.5 mm2 (#2-16 AWG…#1-20 AWG) (Either Solid or Stranded) Strip Length: 9 mm (3/8 in.) – Toque: 0.8 N•m (7 lb•in

Rockwell Automation Publication 700-TD552C-EN-P - October 2018

43

Page 44

Relay and Timer Specifications

700-HK Slim Line Relay • 8 A/16 A contact ratings • DPDT/SPDT • Plug-in blade-style terminals • Retainer clip with sockets • Options: LED, push-to-test and manual override, socket-mounted surge suppressor module, or timer module • Standard ON/OFF flag indicator • Relay faceplate accepts optional 1492 snap-in markers • Choice of standard silver/nickel contacts or silver/nickel with gold plated contacts • Maximum duty version available Photo

Description

SPDT 1-Pole 1 Form C AgNi Contacts

Contact Rating

Wiring Diagrams U.S./Canada

International

16 A

Input

700-HN121, 700-HN221, 700-HN223

Socket

DPDT 2-Pole 2 Form C AgNi Contacts

700-HN121, 700-HN221, 700-HN223

8A

Input

Socket

44

700-HN122, 700-HN222, 700-HN224

700-HN122, 700-HN222, 700-HN224

Rockwell Automation Publication 700-TD552C-EN-P - October 2018

Coil Voltage

Cat. No.

6V AC

700-HK36A06

12V AC

700-HK36A12

24V AC

700-HK36A24

120V AC

700-HK36A1

240V AC

700-HK36A2

6V DC

700-HK36Z06

12V DC

700-HK36Z12

24V DC

700-HK36Z24

48V DC

700-HK36Z48

110V DC

700-HK36Z1

6V AC

700-HK32A06

12V AC

700-HK32A12

24V AC

700-HK32A24

120V AC

700-HK32A1

240V AC

700-HK32A2

6V DC

700-HK32Z06

12V DC

700-HK32Z12

24V DC

700-HK32Z24

48V DC

700-HK32Z48

110V DC

700-HK32Z1

Page 45

Relay and Timer Specifications

Accessories- 700-HK Relays Photo

Description

Pkg. Qty.

Cat. No.

Screw Terminal Socket, Panel or DIN Rail Mounting 5-blade miniature socket with 10 A rating for use with 1-pole, 700-HK relays. Accepts forked lug conductors. Socket includes a retainer clip.

10

700-HN121

Screw Terminal Socket, Panel or DIN Rail Mounting 5-blade miniature socket with 16 A rating for use with 1-pole, 700-HK relays. Retainer clips are packaged separately with socket. Guarded terminal construction and compatible with optional plug-in module accessories.

10

700-HN221

Spring Clamp Terminal Socket, Panel or DIN Rail Mounting 5-blade miniature socket for use with 1-pole, 700-HK relays.

10

700-HN223

Screw Terminal Socket, Panel or DIN Rail Mounting 8-blade miniature socket with 5 A rating for use with 2-pole, 700-HK relays. Accepts forked lug conductors. This socket includes a retainer clip.

10

700-HN122

Screw Terminal Socket, Panel or DIN Rail Mounting 8-blade miniature socket with 8 A rating for use with 2-pole, 700-HK relays. Retainer clips are packaged separately with socket. Guarded terminal construction and compatible with optional plug-in module accessories.

10

700-HN222

Spring Clamp Terminal Socket, Panel or DIN Rail Mounting 8-blade miniature socket for use with 2-pole 700-HK relays.

10

700-HN224

Flange Mount Adapter Used for panel-mounting bulletin 700-HK relays. Order must be for 10 adapters or multiples of 10.

10

700-HN226

35 mm Rail Mount Adapter Mounts bulletin 700-HK relays to a 35 mm rail. Order must be for 10 adapters or multiples of 10.

10

700-HN227

Socket Retainer Clip and Ejection Lever For use with 700-HN22, -HN222, -HN223, and -HN224 sockets. Orders must be for 10 clips or multiples of 10.

10

700-HN229

Rockwell Automation Publication 700-TD552C-EN-P - October 2018

45

Page 46

Relay and Timer Specifications

Specifications- 700-HK Relays Attribute

700-HK Electrical Ratings

Rated Thermal Current (Ith)

1-Pole, 1 CO, SPDT, 16 A

2-Pole, 2 CO, DPDT, 8 A

Rated Insulation Voltage (Ui)

250V IEC, 300V UL/CSA 120V AC

AC-15, 6.2 A B300 Pilot Duty, 3 A A300 (700-HKM_) 1/3 Hp (0.24 kW) 1-phase

120V AC

AC-15, 2.9 A B300 Pilot Duty, 3.0 A 1/4 Hp (0.18 kW), 1-phase

240V AC

AC-15, 3.1 A B300 Pilot Duty, 1.5 A A300(700-HKM_) 3/4 Hp (0.55 kW), 1-phase

240V AC

AC-15, 1.4 A B300 Pilot Duty, 1.5 A 1/2 Hp (0.37 kW), 1-phase

230V AC

0.55 kW, 1-phase

230V AC

0.37 kW, 1-phase

24V DC

DC-13, 5.0 A

24V DC

DC-13, 3.0 A

125V DC

DC-13, 0.2 A / R300 Pilot Duty, 0.22 A

125V DC

DC-13, 0.2 A / R300 Pilot Duty, 0.22 A

250V DC

DC-13, 0.1 A / R300 Pilot Duty, 0.11 A

5 A, 250V AC

DC-13, 0.1 A / R300 Pilot Duty, 0.11 A

230V AC

AC-1, 16 A

230V AC

AC-1, 8 A

277V AC

16 A, General Use

277V AC

8 A, General Use

30V DC

DC-1, 12 A / 10 A, Resistive

30V DC

DC-1, 6 A / 6 A, Resistive

Inductive V AC

Contacts Inductive V DC

Resistive Make, Break , and Continuous Min. Permissible Contact Ratings

Permissible Coil Voltage Variation

Pickup: holding Voltage: Must Dropout Voltage:

300 mW (5V/60 mA or 60V/5 mA) for AgNi Contacts (700-HK3_) 50 mW (5V/10 mA or 25V/2 mA) for AgNi + Gold Contacts (700-HKX_) 500 mW (100V/5 mA or 5V/100 mA) for AgSnO2 Contacts (700-HKM_) 80…110% of Nominal Voltage at 50/60 Hz, 73...110% of Nominal Voltage at DC 80% of Nominal V AC at 50/60 Hz, 40% of Nominal V DC 20% of Nominal V AC at 50/60 Hz, 10% Nominal V DC

Power Consumption

1.2V A (V AC Coils), 0.5 W (V DC Coils)

Coil Voltages

See Overview/Product Selection Design Specification/Test Requirements

Dielectric Withstand Voltage

Pole to Pole (VRMS) Contact to Coil (VRMS)

2000V AC 4000V AC Mechanical

Degree of Protection

IP 20 (guarded terminal sockets), RT II, Flux-proof (Relay) 10 x 106

Mechanical Life Operations 230V AC, 16 A Resistive: 100 000 min. 277V AC, 16 A Resistive: 30 000 min. 30V DC, 10 A Resistive: 30 000 min. B300, R300, Hp (kW): 6000 min. A300 (700-HKM_): 100,000 min.

Electrical Lifecycles

Mechanical: 18,000 cycles/hr. Electrical: 900 cycles/hr.

Switching Frequency Operating Time at Nominal Voltage at 20 °C (ms)

230V AC, 8 A Resistive: 100 000 min. 277V AC, 8 A Resistive: 30 000 min. 30V DC, 6 A Resistive: 30 000 min. B300, R300, Hp (kW): 6000 min.

Pickup

15 ms

Dropout

5 ms

Vibration

Operational Non-Operational

10…2000 Hz, 0.76 mm (0.03 in.) 2.5 G 10…2000 Hz, 0.76 mm (0.03 in.) 5.0 G

Shock

Operational Non-Operational

15 G 50 G Environmental

Temperature

Operating Storage

–40…+70 °C (–40…+158 °F) –40…+85 °C (–40…+185 °F)

Altitude

2000 m (6560 ft) Construction

Insulating Material Enclosure Contact Material Terminal Markings on Socket

46

Molded High Dielectric Material Transparent Dust Cover 700-HK3_: Silver nickel (AgNi); 700-HKX_: Silver Nickel + Gold Plating (AgNi + Au); 700-HKM_: Silver Tin Oxide(AgSnO2) In accordance with EN 50005

Rockwell Automation Publication 700-TD552C-EN-P - October 2018

Page 47

Relay and Timer Specifications

Attribute

700-HK

Sockets

1-Pole

2-Pole

Screw Terminal

700-HN121 (10 A @ 70 °C) 700-HN221 (16 A @ 50 °C, 12 A @ 70 °C)

700-HN122 (2 x 5 A @ 70 °C) 700-HN222 (2 x 8 A @ 70 °C)

Spring Clamp

700-HN223 (15 A @ 40 °C with 2 conductors per terminal) (10 A @ 70 °C with 1 conductor per terminal)

700-HN224 (2 x 8 A@ 70 °C)

Approvals Certifications

CSA Certified, File 75088, UL Recognized, File E3125 Guide NLDX2/NLCX8, cULus Listed with Allen-Bradley sockets (File No. 3125 Guide NLDX/NLDX7), CE Marked

Standards

EN61810-1, CSA 22.2 No. 14, UL 508

Dimensions- 700-HK Relays Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes. 12.4 (1/2)

12.4 (1/2)

29.0 (1-9/64)

32.8 (1-19/64)

29.0 (1-9/64)

32.8 (1-19/64)

30.1 (1-3/16)

6.5 (1/4)

6.5 (1/4)

2.5 (3/32) 4.75 (3/16) A1 5

0.5 (1/32) COM 11 4

A2 NC 22 NO 24 1 5 7 COM 21 6

NC 12 NO 14 2 3 Cat. No. 700-HK36_ (SPDT) NO 14 4

NC 12 2

0.5 (1/32)

COM 11 3 NO 14 A1 NC 12 4 2 8

A2 1

COM 11 3

30.1 (1-3/16)

Cat. No. 700-HK32_ (DPDT) COM 11 NO 14 NC 12 3 4 2

A1 8

A1 8 15.8 (5/8)

15.8 (5/8) COM 21 6

NO 24 5

NC 22 7 Cat. No. 700-HN224

A2 1

COM 21 NO 24 NC 22 6 5 7

A2 1 Cat. No. 700-HN222

COM 11 4

NO 14 3

NC 12 2

A1 5

COM 11 NO 14 NC 12 4 3 2

A1 5

15.8 (5/8)

15.8 (5/8)

A2 1

A2 1 Cat. No. 700-HN221

Cat. No. 700-HN223

64.9 (2-9/16)

44.7 (1-3/4)

32.5 22.6 (1-9/32) (57/64)

35.3 (1-25/64)

34.7 (1-3/8) 95.6 (3-49/64)

35.4 (1-13/32) 82.85 (3-17/64)

Cat. No. 700-HN223, 700-HN224 Wire Size: 0.2 mm2...1.5 mm2 (#24 AWG....#14 AWG) Either Solid or Stranded Strip Length: 8 mm (5/16 in)

Cat. No. 700-HN221, 700-HN222 Wire Size: 0.2 mm2...2.5 mm2 (#24 AWG....#12 AWG) Either Solid or Stranded Strip Length: 8 mm (5/16 in), Torque: 0.8Nm (7.0 lb.-in.)

Rockwell Automation Publication 700-TD552C-EN-P - October 2018

47

Page 48

Relay and Timer Specifications

Dimensions - 700-HK Relays Approximate dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes. 46.0 (1-13/16) 14.4 (37/64)

3.6 (9/64)

14.4 (37/64)

38.0 (1-1/2)

46.9 (1-27/32)

42.4 (1-43/64)

36.6 (1-11/16)

39.8 (1-37/64)

18.1 (23/32)

2.0 (5/64)

34.8 (1-3/8) Cat. No. 700-HN227

Cat. No. 700-HN226

6.2 (15/64)

50 (1-63/64)

1.0 (0.04)

12.5 (1/2)

27.0 (1.06)

35.0 (1.38)

5.2 (13/64)

7.5 (0.30)

1000 (39-3/8) Cat. No. 199-DR4 DIN Mounting Rail Series B Has No Mounting Holes Cat. No. 199-DR1 DIN Mounting Rail Series B

A

B

C

D

Approx. Shipping Wt.

199-DR1

35 (1-3/8)

27 (1-1/16)

7.5 (19/64)

1.02 (1/64)

1.85 kg (4.07 lb) (10/pkg)

199-DR4

35 (1-3/8)

27 (1-1/16)

15 (19/32)

2.3 (3/32)

3.68 kg (8 lb) (5/pkg)

Cat. No.