Page 91

Digital Output

KL2531, KL2541

Bus Terminal

Digital output | 24/50 V DC, stepper motor terminals

550

Stepper motors are often used in positioning drives. They allow, by the combination of single steps, a positioning process without feedback of the rotor positions. This “open control chain” mode of operation and the longevity of a stepper motor are particularly interesting for price-sensitive fields of application. However, safe positioning is only guaranteed within the performance limits. In contrast with a DC motor the control of a stepper motor is carried out by the different energisation of the individual motor windings following a defined pattern of pulses. The electromagnetic field of the stator is switched intermittently so that the shaft turns through the step angle α. The motor follows the impulse pattern of the control unit, until the coupled momentum exceeds its holding momentum or the impulse demand is too dynamic, which leads to standstill of the motor. With the KL2531 and KL2541 stepper motor terminals, which are suitable for highly dynamic movement, this problem in areas of higher speeds of rotation can be solved. The KL2531 and KL2541 stepper motor terminals are designed for direct connection of medium capacity stepper motors. A high frequency clocked PWM output stage regulates the currents through the motor coils. The stepper motor terminals are synchronised with the motor by parameterising. Unipolar as well as bipolar stepper motors can be driven.

Additional inputs support functions like homing and final position monitoring. 64-fold micro stepping ensures particularly quiet and precise motor operation. Together with a stepper motor, the stepper motor terminals represent an inexpensive small servo axis. The KL2541 also includes an incremental encoder interface to read position data. Both KL2531 and KL2541 stepper motor terminals can be controlled like a servo drive by a speed interface from a Motion Control software such as TwinCAT for example. In applications with a less complex and less powerful CPU the control is also possible via a position interface (travel distance control). The stepper motor terminals move the motor themselves to a desired position. Ramp steepness and maximum speed can be entered as parameters. Irregular operation at certain speed ranges, particularly without coupled load, indicates that the stepper motor is being runat its resonance frequency. Under certain circumstances the motor may even stop. Resonances in the lower frequency range essentially result from the mechanical motor parameters. Apart from their impact on smooth running, such resonances can lead to significant loss of torque, or even loss of step of the motor, and are therefore particularly undesirable. Due to their sine/ cosine current profile, KL2531 and KL2541 stepper motor terminals are able to prevent this effect in almost all standard motors. The rotor is not moved from step to step, so it no longer jumps to the next position, but moves through 64 intermediate steps. So the rotor is carefully moved from one step to the next. The usual loss of torque at certain speeds is avoided and operation can be optimised for the particular application. This means that the lower speed range, where particularly high torque is available, can be fully utilised. The KL2531 stepper motor terminal is designed exclusively for 24 V supply voltage. The motor current can reach up to 1.5 A. The KL2541 covers a supply voltage range from 8 V DC to 50 V DC and also needs a 24 V supply from the power contacts. The motor current can be set from 1 to 5 A. The peak current may briefly significantly exceed the rated current and in this way makes the whole drive system very dynamic. In such dynamic applications, negative acceleration causes the feedback of energy, which leads to voltage peaks at the power supply unit. A KL9570 buffer capacitor terminal protects from the effects of overvoltage, in that it absorbs some of the energy. If the voltage exceeds the capacity of the terminal, it gets rid of the excess energy via an external resistance. AS1xxx | Stepper motors see page

A1

A2

A1

A2

A1

A2

B1

B2

B1

B2

B1

B2

M Connection of a unipolar stepper motor

BECKHOFF New Automation Technology

M

776

M

Connection of a bipolar AS10x0 stepper

Connection of a bipolar AS10x0 stepper motor, serial motor, parallel

We reserve the right to make technical changes.

Page 92

KL2531, KL2541

Stepper motor

Stepper motor terminal 24 V DC, 1.5 A terminal 50 V DC, 5 A,

Digital Output with incremental encoder

Technical data

KL2531 | KS2531

KL2541 | KS2541

Connection technology direct motor connection

Load type stepper motors

Max. output current

1.5 A

5A

Number of outputs

1 stepper motor

1 stepper motor, encoder input

Enc

1

5

2

6

B1

1

5

1’

5’

2

6

2’

6’

M A1

A2

3

7

3

7

3’

7’

4

8

4

8

4’

8’

Bus Terminal

B2

551

Nominal voltage

24 V (-15 %/+20 %)

8…50 V DC

Current consumption only load typ. 35 mA power contacts Current consumpt. K-bus typ. 60 mA typ. 100 mA

Number of inputs

2

2 for limit position, 4 for an encoder system

Maximum step frequency

125,000 steps/s

125,000 steps/s

Step pattern full step, half step, up to 64-fold micro stepping full step, half step, up to 64-fold micro stepping

Current controller approx. 25 kHz approx. 25 kHz approx. 5,000 positions in typ. applications approx. 5,000 positions in typ. applications

(per revolution)

(per revolution)

Special features integrated travel distance control integrated travel distance control

Operating temperature

0…+55 °C

0…+55 °C

Approvals

CE

CE

Weight approx. 50 g approx. 100 g

Further information www.beckhoff.com/KL2531 www.beckhoff.com/KL2541 frequency Resolution

Special terminals

KL2541-0006

Distinguishing features stepper motor terminal 50 V DC, 5 A, 5 V encoder supply

We reserve the right to make technical changes.

BECKHOFF New Automation Technology

Page 93

Digital Output

KL2532, KL2552

Bus Terminal

Digital output | 24/50 V DC, DC motor output stage

552

Compared to other motors a DC motor is easier to adjust. The speed of rotation is proportional to the voltage. With the KS2532 Bus Terminal the rotation speed can easily be set through the process data. The integrated compensation of the internal resistance keeps the motor at the desired speed for load changes. A simple drive task can be performed by a simple controller. For demanding positioning tasks a closed speed control loop with a feedback system is needed. The KL2542 allows connection of an incremental encoder. The control loop can be closed by the higher-level controller. The peak current may briefly significantly exceed the rated current and in this way makes the whole drive system very dynamic. In such dynamic applications, negative acceleration causes the feedback of energy, which leads to voltage peaks at the power supply unit. A KL9570 buffer capacitor terminal protects from the effects of overvoltage, in that it absorbs some of the energy. If the voltage exceeds a threshold, the terminal dissipates the excess energy via an external resistance.

2-channel DC motor

2-channel DC motor output stage, 24 V DC, output stage, 50 V DC,

1A

5A

Technical data

KL2532 | KS2532

KL2552 | KS2552

Connection technology direct motor connection

Load type

DC brush motors, inductive

Max. output current

2 x 1 A (short-circuit-proof,

2 x 5 A (short-circuit-proof, thermal overload-proof for thermal overload-proof for both channels together)

both channels together)

2 DC motors

2 DC motors, encoder input

Number of outputs

Enc

1

2

KL9750 | Buffer capacitor terminal see page 604

5

A1

A2

B1

B2

6

M

1

5

1’

5’

M

2

6

2’

6’

3

7

3

7

3’

7’

4

8

4

8

4’

8’

Nominal voltage

24 V DC (-15 %/+20 %)

8…50 V DC

Current consumption typ. 30 mA + load typ. 50 mA

Current consumpt. K-bus typ. 50 mA typ. 100 mA

Reverse voltage protection

–

–

PWM clock frequency

30 kHz with 180° phase

30 kHz with 180° phase shift each shift each

0…100 %

0…100 %

(voltage-controlled)

(voltage-controlled)

max. 10 bits current, max. 10 bits current,

16 bits speed

16 bits speed

Encoder signal

–

5…24 V, 5 mA single-ended

Pulse frequency

– max. 400,000 increments/s

Operating temperature

0…+55 °C

0…+55 °C

Approvals

CE

CE

Weight approx. 55 g approx. 100 g

Further information www.beckhoff.com/KL2532 www.beckhoff.com/KL2552 power contacts

Duty factor Resolution

(with 4-fold evaluation)

BECKHOFF New Automation Technology

We reserve the right to make technical changes.

Page 94

KL2791

Digital Output

Digital output | 230 V AC, AC motor speed controller 1-channel AC motor speed controller, 230 V AC, 200 VA

Technical data

KL2791 | KS2791

Connection technology direct motor connection

Load type

1-phase AC motors

Max. output current

0.9 A

Number of outputs

1 motor

1

5

230 V

2

6

N

3

7

PE

4

8

M 1~

Bus Terminal

When driving working machines whose production or conveying performance can be influenced via the drive speed of the motor, energy can be saved by means of variable speed. This particularly applies if the change in the motor speed is also linked with large changes in the emitted mechanical output. Increase the speed – higher load, decrease – lower load. This procedure is particularly suitable for uncontrolled units with a square load characteristic, because regulating the speed just a little brings about a large change in energy consumption due to its square influence. Using the KL2791 single-phase AC motor terminal, a single-phase AC motor with a maximum power consumption of 0.2 KW can be operated with speed control depending on the process data. L1 and N of the motor are wired directly to the terminal; this is in turn integrated in the control environment via a Bus Coupler or connected directly to an embedded device. The controller specifies the set value for the motor speed in the form of a 16-bit word; the speed is regulated internally in the terminal. The motor is switched on and off with a practice-proven mains-synchronous pattern, so that the motor consumes less power and the speed falls significantly. This method is well suited to motors with fixed loads, such as pumps and fans, in order to achieve a control range for the flow rate from 10 to 100 %.

553 Motor load

Nominal voltage

230 V AC

Current consumption only load power contacts Current consumpt. K-bus typ. 65 mA

Reverse voltage protection no

Rated output

≤ 200 VA

Control type phase/full wave control

Resolution

1%

Leakage current

< 1 mA (OFF state)

Operating temperature

0…+55 °C

Approvals

CE

Weight approx. 60 g

Further information www.beckhoff.com/KL2791

Special terminals

KL2791-0011

KL2791-1200

Distinguishing features

230 V AC, 200 VA,

120 V AC, 100 VA max. 0.9 A, without power contacts

We reserve the right to make technical changes.

BECKHOFF New Automation Technology

Page 95

Analog Input

KL3001, KL3002

Bus Terminal

Analog input | -10…+10 V

554

The KL3xxx Bus Terminals read analog signal voltages in the common standard signal range of -10 to +10 V, 0 to 10 V, 0 to 20 mA and 4 to 20 mA. Inside the terminal the field side of the K-bus is electrically isolated and enables the interconnection to desired potential groups. The 1-channel terminals are available for applications in which each signal must be completely isolated. An additional electrically isolated 24 V DC supply can be created by the application of the KL9560 power supply terminal (24 V DC/24 V DC). The analog input Bus Terminals differ in their different resolutions of the analog/ digital conversion, conversion speed and accuracy. For 1- and 2-channel terminals 1-, 2-, 3- and 4-wire connections are available for the sensors. 4-channel Bus Terminals can only be used with 1- and 2-wire connections. The KL3454 is optimised for the use of 2-wire sensors with 24 V DC supply. The signal current is measured between ground and the input. The second connection point for the sensor is the 24 V supply from the terminal’s power contact. The input circuit of the terminals differs between single-ended and differential inputs. A single-ended input expects a signal with a fixed reference to ground. In practice, singleended is easily to be wired using single-wire connection. The differential input only measures the difference between both inputs +I and -I. An overlap within the commonmode area (common-mode voltage) has no effect on the result. For measurement two conductors should always be connected; in the case of single-wire connection input -I can be connected to ground. The product range is rounded off by further special input voltages and covers a wide field of applications for the processing of analog signals. By the expansion of power supply terminals well-stabilised auxiliary voltages from 5 to 15 V can be generated.

BECKHOFF New Automation Technology

1-channel analog

2-channel analog input terminal, input terminal,

-10…+10 V, 12 bits,

-10…+10 V, 12 bits, differential input differential input

Technical data

KL3001 | KS3001

KL3002 | KS3002

Signal voltage

-10…+10 V

Resolution

12 bits (for 0…10 V range: resolution 11 bits)

Technology differential input differential input

Conversion time

~ 1 ms

~ 2 ms

Number of inputs

1

2

+60 °C -20 °C

1

5

1

5

2

6

2

6

3

7

3

7

4

8

4

8

The KL3001 analog input terminal is characterised by its electrical isolation.

The KL3002 analog input terminal combines two differential inputs with a common internal ground potential in one housing.

< ±0.3 % (relative

< ±0.3 % (relative to full scale value)

to full scale value)

– (no power contacts)

– (no power contacts)

Current consumpt. K-bus typ. 65 mA typ. 65 mA

Internal resistance

> 200 kΩ

> 200 kΩ

Common-mode voltage UCM

35 V max.

35 V max.

Special features

–

–

Operating temperature

0…+55 °C

-20…+60 °C

Approvals

CE, UL, Ex

CE, UL, Ex

Weight approx. 70 g approx. 70 g

Further information www.beckhoff.com/KL3001

Measuring error Current consumption power contacts www.beckhoff.com/KL3002

Special terminals

KL3002-00xx

Distinguishing features special terminals see

605

We reserve the right to make technical changes.

Page 96

KL340x, KL31xx

Analog Input

4-channel analog

8-channel analog

2-channel analog

2-channel analog input terminal, input terminal, input terminal, input terminal,

-10…+10 V, 12 bits,

-10…+10 V, 12 bits,

-10…+10 V, 16 bits,

-10…+10 V, 16 bits, single-ended single-ended differential input differential input

KL3404 | KS3404

KL3408 | KS3408

KL3102 | KS3102

KL3132 single-ended single-ended differential input differential input

~ 2 ms

~ 4 ms

~ 140 ms, configurable to 2 ms

~ 140 ms, configurable

4

8

2

2

1

5

2

6

3

7

4

8

1

5

1

5

1

5

+24 V

2

6

2

6

2

6

0V

3

7

3

7

3

7

4

8

4

8

4

8

Bus Terminal

16 bits (for 0…10 V range: resolution 15 bits)

555

The KL3404 analog input terminal has four inputs, which are implemented in 2-wire technique. The common reference ground of the inputs is the internal ground.

The KL3408 analog input terminal combines eight inputs in one housing. The use of single conductor connection technology enables the connection of multi-channel sensor technology with minimum space requirements. The reference ground for all inputs is the 0 V power contact.

The KL3102 analog input terminal combines two differential inputs with a common internal ground potential in one housing.

The KL3132 analog input terminal is optimised for highly accurate control processes due to its low measuring error of ±0.05 % (in relation to the full scale value). The differential inputs have a common, internal ground potential.

< ±0.3 % (relative

< ±0.3 % (relative

< ±0.3 % (relative

< ±0.05 % (relative to full scale value)

to full scale value)

to full scale value)

to full scale value)

–

–

– (no power contacts)

– typ. 100 mA typ. 140 mA typ. 65 mA typ. 85 mA

> 130 kΩ

> 130 kΩ

> 200 kΩ

> 200 kΩ

–

–

35 V max.

35 V max.

– high packing density

– increased measuring accuracy

0…+55 °C

0…+55 °C

0…+55 °C

0…+55 °C

CE, UL, Ex, GL

CE, UL, Ex, GL

CE, UL, Ex

CE, UL, Ex approx. 75 g approx. 75 g approx. 70 g approx. 70 g www.beckhoff.com/KL3404 www.beckhoff.com/KL3408 www.beckhoff.com/KL3102 www.beckhoff.com/KL3132

KL3102-0050 Siemens S7 format

We reserve the right to make technical changes.

BECKHOFF New Automation Technology

Page 97

Analog Input

KL306x, KL3464

Analog input | 0…10 V, 0…2 V, 0…500 mV, ±2 V 2-channel analog

4-channel analog

4-channel analog input terminal, input terminal, input terminal, input terminal,

0…10 V, 12 bits,

0…10 V, 12 bits,

0…10 V, 12 bits,

0…10 V, 12 bits, single-ended single-ended single-ended single-ended

Technical data

KL3061 | KS3061

KL3062 | KS3062

KL3064 | KS3064

KL3464 | KS3464

Signal voltage

0…10 V

Resolution

12 bits

Technology single-ended single-ended single-ended single-ended

Conversion time

~ 1 ms

~ 2 ms

~ 4 ms

~ 2 ms

Number of inputs

1

2

4

4

Bus Terminal

1-channel analog

+60 °C

+60 °C

-20 °C

-20 °C

1

5

1

5

1

5

1

5

2

6

2

6

2

6

2

6

3

7

3

7

3

7

3

7

4

8

4

8

4

8

4

8

556

The KL3061 analog input terminal is characterised by its fine granularity and electrical isolation.

The KL3062 analog input terminal combines two single-ended inputs with a common internal ground potential in one housing.

The KL3064 analog input terminal contains four single-ended inputs with a common internal ground potential.

The KL3464 analog input terminal combines four single-ended inputs with a common internal ground potential in one housing.

< ±0.3 % (relative

< ±0.3 % (relative

< ±0.3 % (relative

< ±0.3 % (relative to full scale value)

to full scale value)

to full scale value)

to full scale value)

– (no power contacts)

– (no power contacts)

– (no power contacts)

–

Current consumpt. K-bus typ. 60 mA typ. 60 mA typ. 85 mA typ. 100 mA

Internal resistance

> 130 kΩ

> 130 kΩ

> 130 kΩ

> 130 kΩ

Common-mode voltage UCM

–

–

–

–

Special features

–

–

–

–

Operating temperature

0…+55 °C

0…+55 °C

-20…+60 °C

-20…+60 °C

Approvals

CE, UL, Ex

CE, UL, Ex

CE, UL, Ex, GL

CE, UL, Ex, GL

Weight approx. 60 g approx. 60 g approx. 80 g approx. 75 g

Further information www.beckhoff.com/KL3061 www.beckhoff.com/KL3062 www.beckhoff.com/KL3064 www.beckhoff.com/KL3464

Special terminals

KL3062-00xx

KL3064-00xx

Distinguishing features special terminals see

Measuring error Current consumption power contacts

BECKHOFF New Automation Technology

605 special terminals see

605

We reserve the right to make technical changes.

Page 98

KL3468, KL31xx

Analog Input

8-channel analog

2-channel analog

2-channel analog

2-channel analog

2-channel analog input terminal, input terminal, input terminal, input terminal, input terminal,

0…10 V, 12 bits,

0…10 V, 16 bits,

0…2 V, 16 bits,

0…500 mV, 16 bits,

-2…+2 V, 16 bits, single-ended differential input differential input differential input differential input

KL3468 | KS3468

KL3162

KL3172

KL3172-0500

KL3182

0…2 V

0…500 mV

-2…+2 V differential input differential input single-ended differential input differential input

~ 4 ms

140 ms, configurable

140 ms, configurable

140 ms, configurable

140 ms, configurable

8

2

2

2

2

1

5

1

5

1

5

1

5

1

5

+24 V

2

6

2

6

2

6

2

6

2

6

0V

3

7

3

7

3

7

3

7

3

7

4

8

4

8

4

8

4

8

4

8

Bus Terminal

16 bits

557

The KL3468 analog input terminal combines eight inputs in one housing. The use of single conductor connection technology enables the connection of multi-channel sensor technology with minimum space requirements. The reference ground for all inputs is the 0 V power contact.

The KL3162 analog input terminal is optimised for highly accurate control processes due to its low measuring error of ±0.05 % (in relation to the full scale value). The differential inputs have a common, internal ground potential.

The KL3172 analog input terminal is optimised for highly accurate control processes due to its low measuring error of ±0.05 % (in relation to the full scale value). The differential inputs have a common, internal ground potential.

The KL3172-0500 analog input terminal is optimised for highly accurate control processes due to its low measuring error of ±0.05 % (in relation to the full scale value). The differential inputs have a common, internal ground potential.

The KL3182 analog input terminal is optimised for highly accurate control processes due to its low measuring error of ±0.05 % (in relation to the full scale value). The differential inputs have a common, internal ground potential.

< ±0.3 % (relative

< ±0.05 % (relative

< ±0.05 % (relative

< ±0.05 % (relative

< ±0.05 % (relative to full scale value)

to full scale value)

to full scale value)

to full scale value)

to full scale value)

–

–

–

–

– typ. 140 mA typ. 85 mA typ. 85 mA typ. 85 mA typ. 85 mA

> 130 kΩ

> 200 kΩ

> 200 kΩ

> 200 kΩ

> 200 kΩ

–

35 V max.

35 V max.

35 V max.

35 V max.

high packing density increased measuring accuracy increased measuring accuracy increased measuring accuracy increased measuring accuracy

0…+55 °C

0…+55 °C

0…+55 °C

0…+55 °C

0…+55 °C

CE, UL, Ex, GL

CE, UL, Ex

CE, UL, Ex

CE, UL, Ex

CE, UL, Ex approx. 75 g approx. 70 g approx. 70 g approx. 70 g approx. 70 g www.beckhoff.com/KL3468 www.beckhoff.com/KL3162 www.beckhoff.com/KL3172 www.beckhoff.com/KL3172 www.beckhoff.com/KL3182

We reserve the right to make technical changes.

BECKHOFF New Automation Technology

Page 99

Analog Input

KL30xx, KL3444

Analog input | 0…20 mA 1-channel analog

2-channel analog

4-channel analog

4-channel analog input terminal, input terminal, input terminal, input terminal,

0…20 mA, 12 bits,

0…20 mA, 12 bits,

0…20 mA, 12 bits,

0…20 mA, 12 bits, differential input differential input single-ended single-ended

Technical data

KL3011 | KS3011

KL3012 | KS3012

KL3044

KL3444 | KS3444

Signal current

0…20 mA

Resolution

12 bits

Technology differential input differential input single-ended single-ended

Conversion time

~ 1 ms

~ 2 ms

~ 4 ms

~ 2 ms

Number of inputs

1

2

4

4

+60 °C

1

5

1

5

1

5

1

5

2

6

2

6

2

6

2

6

Bus Terminal

-20 °C

3

7

3

7

3

7

3

7

558

4

8

4

8

4

8

4

8

The KL3011 analog input terminal is characterised by its electrical isolation. The input channels of the Bus Terminal have differential inputs and possess a common, internal ground potential.

The KL3012 analog input terminal combines two differential inputs with a common internal ground potential in one housing.

The KL3044 analog input terminal has four inputs, which are implemented in 2-wire technique. The common reference ground of the inputs is the internal ground.

The KL3444 analog input terminal has four inputs, which are implemented in 2-wire technique. The common reference ground of the inputs is the internal ground.

< ±0.3 % (relative

< ±0.3 % (relative

< ±0.3 % (relative

< ±0.3 % (relative to full scale value)

to full scale value)

to full scale value)

to full scale value)

Current consum. pow.cont.

– (no power contacts)

– (no power contacts)

– (no power contacts)

–

Current consumpt. K-bus typ. 60 mA typ. 60 mA typ. 65 mA typ. 85 mA

Internal resistance

80 Ω + 0.7 V

80 Ω + 0.7 V

80 Ω + 0.7 V

< 85 Ω

Common-mode voltage UCM

35 V max.

35 V max.

–

–

Surge voltage resistance

35 V DC

35 V DC

35 V max.

30 V DC

Special features

–

–

–

–

Operating temperature

0…+55 °C

-20…+60 °C

0…+55 °C

0…+55 °C

Approvals

CE, UL, Ex, GL

CE, UL, Ex, GL

CE, UL, Ex, GL

CE, UL, Ex, GL

Weight approx. 70 g approx. 70 g approx. 70 g approx. 75 g

Further information www.beckhoff.com/KL3011 www.beckhoff.com/KL3012 www.beckhoff.com/KL3044 www.beckhoff.com/KL3444

Measuring error

Special terminals

KL3012-00xx

Distinguishing features special terminals see

BECKHOFF New Automation Technology

605

We reserve the right to make technical changes.

Page 100

KL3xxx

Analog Input

8-channel analog

1-channel analog

2-channel analog

2-channel analog

2-channel analog input terminal, input terminal, input terminal, input terminal, input terminal,

0…20 mA, 12 bits,

0…20 mA, 12 bits,

0…20 mA, 12 bits,

0…20 mA, 15/16 bits,

0…20 mA, 16 bits, single-ended with sensor supply with sensor supply differential input differential input

KL3448 | KS3448

KL3041 | KS3041

KL3042 | KS3042

KL3112

KL3142

15 bit, configurable to 16 bit

16 bits differential input single-ended single-ended single-ended differential input

~ 4 ms

~ 1 ms

~ 2 ms

140 ms, configurable to 2 ms

140 ms, configurable

8

1

2

2

2

+60 °C

1

5

1

5

1

5

1

5

1

5

2

6

2

6

2

6

2

6

2

6

3

7

3

7

3

7

3

7

3

7

Bus Terminal

-20 °C

4

8

4

8

4

8

4

8

4

8

559

The KL3448 analog input terminal combines eight inputs in one housing. The use of single conductor connection technology enables the connection of multi-channel sensor technology with minimum space requirements. The reference ground for all inputs is the 0 V power contact.

The job of the KL3041 and KL3042 analog input terminals is to supply power to measuring transducers located in the field and to transmit analog measurement signals with electrical isolation to the automation device. The voltage for the sensors is supplied to the terminals via the power contacts. The power contacts can optionally be supplied with operating voltage in the standard way or via a supply terminal (KL9560) with electrical isolation. The 0 V power contact is the reference potential for the inputs.

The KL3112 analog input terminal combines two differential inputs with a common internal ground potential in one housing.

The KL3142 analog input terminal is optimised for highly accurate control processes due to its low measuring error of ±0.05% (in relation to the full scale value). The differential inputs have a common, internal ground potential.

< ±0.3 % (relative

< ±0.3 % (relative

< ±0.3 % (relative

< ±0.3 % (relative

< ±0.05 % (relative to full scale value)

to full scale value)

to full scale value)

to full scale value)

to full scale value)

– only load only load

– (no power contacts)

– typ. 105 mA typ. 65 mA typ. 65 mA typ. 60 mA typ. 85 mA

< 85 Ω

80 Ω + 0.7 V

80 Ω + 0.7 V

50 Ω typ. shunt,

1 Ω typ. shunt load: 60 Ω + diode voltage –

–

–

35 V max.

±10 V max.

30 V DC

35 V max.

35 V max.

35 V DC

35 V DC high packing density with sensor supply with sensor supply

– increased measuring accuracy

0…+55 °C

0…+55 °C

-20…+60 °C

0…+55 °C

0…+55 °C

CE, UL, Ex, GL

CE, UL, Ex, GL

CE, UL, Ex, GL

CE, UL, Ex

CE, UL, Ex approx. 75 g approx. 70 g approx. 70 g approx. 70 g approx. 70 g www.beckhoff.com/KL3448 www.beckhoff.com/KL3041 www.beckhoff.com/KL3042 www.beckhoff.com/KL3112 www.beckhoff.com/KL3142

KL3042-00xx

KL3112-0050 special terminals see

We reserve the right to make technical changes.

605 special terminals see

605

BECKHOFF New Automation Technology