Page 131

Communication

KL6xxx

Communication | LON, MP-Bus, DALI LON

DALI

LON Bus Terminal

MP-Bus master terminal

DALI/DSI master and power supply terminal

KL6401 | KS6401

KL6771 | KS6771

KL6811 | KS6811

Technology

LON

MP-Bus

DALI/DSI

Data transfer rates

78 kbit/s

1,200 baud

Number of channels

1

1

Bus Terminal

Technical data

1

5

2

6

Service Service

1

1

5

2

6

5

+DALI

1

5

+24 V

2

6

0V

3

7

4

8

2

-DALI

MP-Bus slave 3

7

3

7

4

8

4

8

1

590 +DALI

-DALI

The KL6401 LON Bus Terminal enables direct connection of LON devices. Several KL6401 can be used with a single Bus Coupler or a Bus Terminal Controller. The KL6401 supports 62 SNVTs. All SNVT types can be configured as input or output variable via the KS2000 software. The KS2000 software generates an XIF file that is integrated in an LON tool.

The MP-Bus master terminal enables direct connection of MP-Bus slave devices. Up to sixteen field devices, eight drives and eight sensors can be connected to the KL6771. The Bus Terminal is configured and commissioned via TwinCAT function blocks. Several KL6771 terminals can be connected to the same Bus Coupler or Bus Terminal Controller.

The KL6811 enables the connection of up to 64 DALI slaves. The KS2000 software enables simple configuration via a PC that is directly coupled with the Bus Coupler via an RS232 interface or via the fieldbus. The integrated power supply unit generates an electrically isolated 24 V DC output voltage. No further components are required for the operation of the DALI slaves. The KL6811 operates fieldbus-independent.

Nominal voltage

24 V DC (-15 %/+20 %)

24 V DC (-15 %/+20 %)

24 V DC (-15 %/+20 %)

Current consum. pow.cont.

only load typ. 10 mA + load typ. 30 mA + load

Current consumpt. K-bus typ. 55 mA typ. 55 mA typ. 55 mA

Data transfer standard

FTT-10, LPT

MP-Bus

DALI

Special features

15 devices;

8 drives/sensors;

connection of up to 64 DALI slaves;

TwinCAT library available

TwinCAT library available

TwinCAT library available

Operating temperature

0…+55 °C

0…+55 °C

0…+55 °C

Approvals

CE, Ex

CE, UL, Ex

CE, UL, Ex

Weight approx. 85 g approx. 85 g approx. 80 g

Further information www.beckhoff.com/KL6401 www.beckhoff.com/KL6771 www.beckhoff.com/KL6811

BECKHOFF New Automation Technology

We reserve the right to make technical changes.

Page 132

KL6904

Communication

Communication | TwinSAFE TwinSAFE enables networks with up to 1,024 TwinSAFE devices. The KL6904 Bus Terminal features certified safety function blocks, which are configured according to the application to be realised. Functions such as emergency stop, safety door monitoring etc. can thus easily be selected and linked. All blocks can be freely connected among each other and are complemented by operators such as AND, OR, etc. The necessary functions are configured using the TwinCAT System Manager and loaded into the terminal via the fieldbus.

TwinSAFE Logic Bus Terminal, 4 safe inputs

Technical data

KL6904

Technology

TwinSAFE Logic

Safety standard

IEC 61508 SIL 3 and DIN EN ISO 13849-1:2008 PLe

Number of outputs

4

Protocol

TwinSAFE/FSoE

1

5

2

6

3

7

Bus Terminal

For further information on TwinSAFE and the TwinSAFE products see page 828

4

8

591

The KL6904 TwinSAFE Logic Bus Terminal can establish 15 connections (TwinSAFE connections). The TwinSAFE logic terminal has four safe, local outputs, so that safety applications can be realised with only two components (KL1904 and KL6904). Nominal voltage

24 V DC (-15 %/+20 %)

Current consum. pow.cont.

load-dependent

Current consumpt. K-bus

250 mA

Cycle time

4…100 ms

Fault response time

≤ watchdog time (parameterisable)

Output current

0.5 A max./20 mA min. (per channel)

Permiss. degree

2 of contamination

We reserve the right to make technical changes.

Climate class EN60721-3-3

3K3

Installation position horizontal

Special features

4 safe outputs

Operating temperature

0…+55 °C

Electrical interference

EN 61000-6-2/EN 61000-6-4

Vibration/shock resistance

EN 60068-2-6/EN 60068-2-27/29

Approvals

CE, UL, Ex, TÜV Süd

Weight approx. 90 g

Further information www.beckhoff.com/KL6904

Special terminals

KL6904-0001

Distinguishing features preconfigured ex factory to 15 TwinSAFE connections

BECKHOFF New Automation Technology

Page 133

Power Terminals

KL8001

Bus Terminal

Power terminals | Siemens contactor, series Sirius 3R

592

The KL8001 power terminal, together with a power contactor, forms a complete distributed motor starter with any fieldbus connection. Apart from all the protective functions of a motor protection relay, the power terminal contains comprehensive diagnostics. By means of values such as current, voltage, active-power input and apparent power consumption or load condition, the control programmer is able to regulate the drive or a machine component in the best possible way and to protect them from damage and failure. The Bus Terminal block is fitted with a KL9060 adapter terminal instead of a KL9010 end terminal. The KL9060 is connected to a power terminal using a simple ribbon cable. Up to ten power terminals can be driven by one KL9060. No other wiring is necessary apart from a ground cable. The power terminal switches the installed contactor and takes over all the functions of the motor protection relay. Apart from its purely protective function of switching off the motor when overloaded, the power terminal can carry out numerous diagnostic functions on the motor and make the information available to the controller via the fieldbus. KL9060 | End terminal with adapter connection for KL8001 power terminals see page 598

Power terminal for Siemens contactor, series Sirius 3R

Technical data

KL8001

Contactor connection mechanism for Siemens contactor series Sirius 3R (switch size S00, Typ 3RT 10 1)

Measured values current, voltage, power

Number of up to 10 (at 140 mA typ. current consumption per contactor)

power terminals

Like a standard motor protection relay the KL8001 power terminal is fitted to a power contactor up to a switching capacity of 5.5 kW. Measuring accuracy

0.1 A AC

Current consumption typ. 7 mA + load power contacts Current consumpt. K-bus typ. 150 mA

Measuring voltage

500 V AC

Power contacts

24 V DC (-15 %/+20 %)/1.4 A max., short-circuit-proof

Setting range of

0.9…9.9 A nominal current Current load max. 25 A (fuse)

Short-circuit-proof up to 5 kA

Internal resistance

< 1 mΩ

Tripping classes class 5, 10, 15, 20, 25, 30 selectable

Type of connection screw terminals up to 2 x 2.5 mm² power path

BECKHOFF New Automation Technology

Type of K-bus connection

2 x flat plug socket, 10-pin

Adapter terminal

KL9060

Short circuit behaviour conforms to EN 60947-4-1 (assignment type 2)/VDE 102

Triggering tolerance conforms to IEC 947, as well as UL and CSA

Operating temperature

0…+55 °C

Approvals

CE

Weight approx. 90 g

Further information www.beckhoff.com/KL8001

We reserve the right to make technical changes.

Page 134

KL8601, KL8610

Power Terminals

Power terminals | TeSys U Communication

Adapter terminal module for TeSys U for TeSys U

Technical data

KL8601

KL8610

Communication unit

TeSys U, all control devices

KL8601

(standard, expanded and multi-functional) Number of modules up to 8 TeSys model U up to 8 KL8601 TeSys model U

Number of outputs

2 (digital 24 V DC)

–

Bus Terminal

The TeSys series from Schneider Electric/ Télémécanique is a product family for the protection and switching of motors. Model U is a very compact motor starter that can be connected directly to the Bus Terminal system via the KL8601 communication module from Beckhoff. Users of TeSys modules therefore have the complete fieldbus range of the Bus Terminal system available. Similar to the KL8001 power terminal from Beckhoff, the motor starter integrates seamlessly into the terminal bus. The motor starter is integrated into the fieldbus system via the KL8610 adapter terminal and a common, screened RJ 45 cable. The 24 V DC supply of the contactor systems is also transferred via this patch cable. The maximum distance between the KL8610 and the first motor starter module is 5 m; the maximum distance between two starters is 0.5 m. Up to eight starters can be connected in series. Spatial separation of I/O and power plane can thus be realised within the control cabinet. Note: The KL8601 communication module, the KL8610 adapter terminal and the accessory cable can be ordered via Schneider Electric/Télémécanique and Beckhoff. The TeSys motor starters are only available from Schneider Electric, the Bus Terminal system only from Beckhoff.

593

The KL8601 communication module is plugged into the TeSys Model U motor starter. It connects the starter with the KL8610 adapter terminal and further motor starters with communication module. The KL8610 adapter terminal provides the connection with the Bus Terminal system. The control and status information of the motor starter evaluation unit are transferred to the Bus Terminal system via the KL8601 communication module.

The KL8610 adapter terminal enables the connection of the TeSys Model U motor starter to the Beckhoff Bus Terminal system. Together with the KL8601 communication module, the KL8610 forms an operational unit in the TeSys motor starter. The KL8610 adapter terminal is attached to the end of the bus terminal block. No further parameterising or configuration work on the KL8610 is necessary apart from plugging-in the connecting cable.

Voltage

–

24 V DC (-15 %/+20 %)

Current consumption

20 mA + load current,

– system bus max. 2 x 0.5 A

Current consumpt. K-bus

–

Output current

0.5 A short-circuit-proof

–

Current load

– max. 2 A short-circuit-proof

Operating temperature

0…+55 °C

0…+55 °C

Motor starter TeSys U

Approvals

CE

CE

Further information can be found on the

Weight approx. 70 g approx. 65 g

Internet at: www.schneider-electric.com

Further information www.beckhoff.com/KL8601 www.beckhoff.com/KL8610

We reserve the right to make technical changes.

typ. 32 mA

BECKHOFF New Automation Technology

Page 135

System Terminals

KL91xx

Bus Terminal

KL91xx, KL92xx | Function terminals

594

The power feed terminals make it possible to set up various potential groups with any desired voltages (KL9190) or with the standard voltages of 24 V DC or 230 V AC (120 V AC). The power feed terminals are available with or without fine-wire fuse. In order to monitor the supply voltage, the terminals with diagnostics report the status of the power feed terminal to the Bus Coupler through two input bits. It is thus possible for the controller to check the distributed peripheral voltage over the fieldbus. The operating point performance conforms to the input terminals KL1002 (24 V) and KL1702 (230 V). The KL9180, KL9185 and KL9195 Bus Terminals allow the supply voltage to be accessed a number of times via spring force terminals. These Bus Terminals make it unnecessary to use additional terminal blocks on the terminal strip. The KL9195 Bus Terminal can be used for the connection of screens. The KL9195 connects the spring force contacts directly to the DIN rail, and can optimally ground incoming electromagnetic radiation. The two power contacts are looped through by the KL9195, allowing two wires to be connected to each power contact. The KL9010 bus end terminal is necessary for data exchange between the Bus Coupler and the Bus Terminals. Each assembly must be terminated at the right hand end with a KL9010 bus end terminal. The bus end terminal does not have any other function or connection facility. The KL9080 is used to identify potential groups (e.g. 230 V AC/ 24 V DC). It is inserted between two potential groups, and indicates the separation through an orange coloured cover.

Potential

Potential

Potential

Potential

Potential supply supply supply supply supply terminal, terminal, terminal, terminal, terminal,

24 V DC

24 V DC,

120…

120…230 V any voltage with

230 V AC

AC, with up to diagnostics

230 V AC diagnostics Technical data

KL9100 |

KL9110 |

KL9150 |

KL9160 |

KL9190 |

KS9100

KS9110

KS9150

KS9160

KS9190

– yes

–

120 V AC/

120 V AC/ arbitrary

230 V AC

230 V AC

Technology potential supply terminal

Diagnostics in the

– yes process image

Nominal voltage

+60 °C

+60 °C

-20 °C

-20 °C

24 V DC

24 V DC

Current load

≤ 10 A

≤ 10 A

≤ 10 A

≤ 10 A

≤ 10 A

Integrated fine-wire fuse

–

–

–

–

–

Power LED green green green green

–

Defect LED

–

–

–

–

–

PE contact yes yes yes yes yes

Shield connection

–

–

–

–

–

Current consumption

– typ. 10 mA

– typ. 10 mA

–

Electrical isolation yes yes yes yes yes

Connection to DIN rail

–

–

–

–

–

Special features

–

–

–

–

–

Operating temperature

-20…+60 °C

-20…+60 °C

0…+55 °C

0…+55 °C

0…+55 °C

Approvals

CE, UL, Ex, GL

CE, UL, Ex, GL

CE, UL, GL

CE, UL, GL

CE, UL, Ex, GL

Weight approx. 50 g approx. 50 g approx. 50 g approx. 50 g approx. 50 g

Further information www.

www.

www.

www.

www.

beckhoff.com/ beckhoff.com/ beckhoff.com/ beckhoff.com/ beckhoff.com/

KL9100

KL9110

KL9150

KL9160

KL9190

K-bus

BECKHOFF New Automation Technology

We reserve the right to make technical changes.

Page 136

KL9xxx

System Terminals

Potential

Potential

Potential

Potential

Potential

Shield

Shield

Separation supply terminal, supply terminal, supply terminal, supply terminal, supply terminal, terminal terminal terminal

24 V DC,

24 V DC,

120…230 V AC,

120…230 V AC, arbitrary, with fuse with diagnostics with fuse with diagnostics with fuse

KL9080 and fuse

KL9200 and fuse

KL9210

KL9250

KL9260

KL9290

KL9070 |

KL9195 |

KS9070

KS9195 shield terminal shield terminal separation terminal yes

– yes

–

+60 °C

+60 °C

-20 °C

-20 °C

1

5

2

6

3

7

4

8

Bus Terminal

–

595

24 V DC

24 V DC

120 V AC/

120 V AC/ arbitrary up to

230 V AC

230 V AC

230 V AC/DC

≤ 60 V arbitrary up to separation

230 V AC terminal

≤ 10 A

≤ 10 A

≤ 10 A

≤ 10 A

≤ 10 A

≤ 10 A

≤ 10 A

–

…6.3 A

…6.3 A

…6.3 A

…6.3 A

…6.3 A

–

–

– green green green green

–

–

–

– red red red red

–

–

–

– yes yes yes yes yes

–

–

–

–

–

–

–

–

8x

2x

–

– typ. 10 mA

– typ. 10 mA

–

–

–

– yes yes yes yes yes yes

–

–

–

–

–

–

– yes yes

–

– integrated fuse integrated fuse integrated fuse integrated fuse dissipation of

– placeholder ter-

EMC interference minal with K-bus via large copper transmission surfaces on the DIN rail 0…+55 °C

-20…+60 °C

0…+55 °C

0…+55 °C

0…+55 °C

0…+55 °C

0…+55 °C

-20…+60 °C

CE, UL, Ex, GL

CE, UL, Ex, GL

CE, UL, Ex, GL

CE, UL, Ex, GL

CE, UL, Ex, GL

CE, UL, Ex

CE, UL, Ex, GL

CE, UL, Ex, GL approx. 50 g approx. 55 g approx. 55 g approx. 55 g approx. 50 g approx. 50 g approx. 50 g approx. 50 g www.

www.

www.

www.

www.

www.

www.

www.

beckhoff.com/ beckhoff.com/ beckhoff.com/ beckhoff.com/ beckhoff.com/ beckhoff.com/ beckhoff.com/ beckhoff.com/

KL9200

KL9210

KL9250

KL9260

KL9290

KL9070

KL9195

KL9080

We reserve the right to make technical changes.

BECKHOFF New Automation Technology

Page 137

System Terminals

KL9180, KL9185

KL91xx | Function terminals, potential distribution Potential distribution

Potential distribution terminal, 2 terminal points terminal, 4 terminal points per power contact at 2 power contacts

Technical data

KL9180 | KS9180

KL9185 | KS9185

Technology potential distribution terminal

Diagnostics in the

– process image

Bus Terminal

The KL91xx potential distribution terminals enable – depending upon the type – the distribution of ground or supply potentials to external devices. Wiring work and separate potential distributors are saved. Eight ground points are required for the ground connection of 8-channel output terminals in 2-wire operating mode, e.g. KL2008, for which the KL9187 can be used. The KL9184 and KL9188 HD Bus Terminals (High Density) even make 16 connection points available in a compact housing.

596

Nominal voltage arbitrary up to arbitrary up to

230 V AC

230 V AC

Current load

≤ 10 A

≤ 10 A

Integrated fine-wire fuse

–

–

Power LED

–

–

Defect LED

–

–

PE contact yes

–

Shield connection

–

–

Current consumption

–

–

Electrical isolation

–

–

Connection to DIN rail

–

–

Special features

–

–

Operating temperature

0…+55 °C

0…+55 °C

Approvals

CE, UL, Ex, GL

CE, UL, Ex, GL

Weight approx. 50 g approx. 50 g

Further information www.beckhoff.com/KL9180 www.beckhoff.com/KL9185

K-bus

BECKHOFF New Automation Technology

We reserve the right to make technical changes.

Page 138

System Terminals

Potential distribution

Potential distribution

Potential distribution

Potential distribution

Potential distribution terminal, 8 x 24 V terminal, 8 x 0 V terminal, 8 x 24 V, 8 x 0 V terminal, 16 x 24 V terminal, 16 x 0 V

KL9186 | KS9186

KL9187 | KS9187

KL9184

KL9188

KL9189

+24 V

1

5

+60 °C

+60 °C

-20 °C

-20 °C

+24 V

0V

1

5

0V

+24 V 1

2

+24 V

2

6

+24 V

0V

+24 V

0V

2

6

3

11

4

12

5

13

6

14

+24 V +24 V

3

7

3

7

+24 V

0V

+24 V +24 V +24 V

4

8

+24 V

0V

4

8

0V

+24 V

0V

+24 V

0V

+24 V

1

10

+24 V

0V

0V 9

+24 V

7

15

8

16

+24 V

2

0V

+24 V

0V

+24 V

0V

+24 V

0V

+24 V

0V

+24 V

+24 V

0V

+24 V

0V

+24 V

0V

9

10

3

11

4

12

5

13

6

14

7

15

8

16

+24 V

0V

+24 V

0V

+24 V

0V

+24 V

0V

+24 V

0V

0V 1

9

2

10

3

11

4

12

5

13

6

14

7

15

8

16

0V 0V

0V 0V

0V 0V 0V

Bus Terminal

KL91xx

597

≤ 60 V DC

≤ 60 V DC

≤ 60 V DC

≤ 60 V DC

≤ 60 V DC

≤ 10 A

≤ 10 A

≤ 10 A

≤ 10 A

≤ 10 A

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

–

– yes yes yes yes yes

–

–

–

–

–

8 x 24 V connection

8 x 0 V connection

8 x 24 V and 8 x 0 V

16 x 24 V connection

16 x 0 V connection connection -20…+60 °C

-20…+60 °C

0…+55 °C

0…+55 °C

0…+55 °C

CE, UL, Ex, GL

CE, UL, Ex, GL

CE, Ex

CE, Ex

CE, Ex approx. 50 g approx. 50 g approx. 60 g approx. 60 g approx. 60 g www.beckhoff.com/KL9186 www.beckhoff.com/KL9187 www.beckhoff.com/KL9184 www.beckhoff.com/KL9188 www.beckhoff.com/KL9189

We reserve the right to make technical changes.

BECKHOFF New Automation Technology

Page 139

System Terminals

KL90xx

KL90xx | Function terminals End terminal

Adapter terminal

End terminal

Coupler terminal for KL8001 power terminals for bus extension for bus extension

KL9060

KL9020

KL9050

Technical data

KL9010

Technology end terminal coupler terminal

Diagnostics in the

– yes process image +60 °C

Bus Terminal

-20 °C

598

The KL9060 Bus Terminal enables a connection to the KL8001. For further information see page 592

The KL9020 forms a properly working unit together with at least one KL9050. No further parameterisation or configuration work is necessary.

The KL9050 coupler terminal replaces the Bus Coupler on a Bus Terminal block. The second RJ 45 socket allows the system to be extended further. The whole system can be extended by 31 stations.

Nominal voltage

–

24 V DC (-15 %/+20 %)

24 V DC (-15 %/+20 %)

24 V DC (-15 %/+20 %)

Current load

–

≤ 10 A

≤ 10 A

≤ 10 A

Power LED

–

–

– green

Defect LED

–

–

–

–

PE contact

– yes

– yes

Current consumption

–

– typ. 70 mA typ. 70 mA + (total K-bus

–

– max. 5 m between max. 5 m between

KL9020 and KL9050

KL9050 and KL9050

K-bus Distance between current)/4, max. 200 mA stations Starting current

–

–

–

2.5 x continuous current

Current supply K-bus

–

–

– up to 400 mA

Electrical isolation

–

500 V (power contact/

500 V (power contact/

500 V (power contact/ supply voltage/K-bus)

supply voltage/K-bus)

supply voltage/fieldbus)

end terminal for connection to KL8001 via end terminal coupler terminal bus communication

20-pin flat ribbon plug for K-bus extension for K-bus extension

Operating temperature

-20…+60 °C

0…+55 °C

0…+55 °C

0…+55 °C

Approvals

CE, UL, Ex, GL

CE

CE, UL, Ex, GL

CE, Ex, GL

Weight approx. 50 g approx. 65 g approx. 45 g approx. 75 g

Further information www.beckhoff.com/KL9010 www.beckhoff.com/KL9060 www.beckhoff.com/KL9020 www.beckhoff.com/KL9050

Special features

(max. 64 Bus Terminals)

BECKHOFF New Automation Technology

We reserve the right to make technical changes.

Page 140

KL93xx

System Terminals

KL93xx | Diode array Bus Terminals Diode array terminal,

Diode array terminal,

Diode array terminal,

4 potential-free diodes

7 diodes (with a com-

7 diodes (with a com- mon cathode)

mon anode)

KL9301 | KS9301

KL9302 | KS9302

Technical data

KL9300 | KS9300

Technology free-wheeling or decoupling diodes

Number of diodes

4

7

Interconnection potential-free common cathode common anode

1

5

1

5

1

5

2

6

2

6

2

6

3

7

3

7

3

7

4

8

4

8

4

8

Bus Terminal

Diodes perform different tasks in control circuits. They decouple, rectify or provide for the freerunning of a coil. The Bus Terminals unite diodes in different circuits and simplify integration into the control cabinet by their compact design. The circuits offered, with common anode or cathode and the individual diodes, minimise the wiring effort in the control cabinet.

599

Nominal cut-off voltage

1,000 V (diodes)

1,000 V (diodes)

1,000 V (diodes)

Output current

1 A on each diode

1 A on each diode

1 A on each diode

Peak current

2.5 A (100 ms)

2.5 A (100 ms)

2.5 A (100 ms)

Voltage drop

0.7 V typ.

0.7 V typ.

0.7 V typ.

Current consumption

–

–

–

< 200 V

< 200 V

< 200 V

(channel/channel)

(channel/channel)

(channel/channel)

Electrical isolation

1,500 V (K-bus/field)

1,500 V (K-bus/field)

1,500 V (K-bus/field)

Operating temperature

0…+55 °C

0…+55 °C

0…+55 °C

Approvals

CE, UL, Ex

CE, UL, Ex

CE, UL, Ex

Weight approx. 50 g approx. 55 g approx. 55 g

Further information www.beckhoff.com/ www.beckhoff.com/ www.beckhoff.com/

KL9300

KL9301

KL9302

K-bus Isolation voltage