Bus Terminal: The modular fieldbus system for automation, pages 131 to 140
Pages 131 to 140 of 156
The original document is the PDF (9.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Beckhoff KL1184, Beckhoff KL2022 and Beckhoff KL2184
Page 131
Communication
KL6xxx
Communication | LON, MP-Bus, DALI LON
DALI
LON Bus Terminal
MP-Bus master terminal
DALI/DSI master and power supply terminal
KL6401 | KS6401
KL6771 | KS6771
KL6811 | KS6811
Technology
LON
MP-Bus
DALI/DSI
Data transfer rates
78 kbit/s
1,200 baud
Number of channels
1
1
Bus Terminal
Technical data
1
5
2
6
Service Service
1
1
5
2
6
5
+DALI
1
5
+24 V
2
6
0V
3
7
4
8
2
-DALI
MP-Bus slave 3
7
3
7
4
8
4
8
1
590 +DALI
-DALI
The KL6401 LON Bus Terminal enables direct connection of LON devices. Several KL6401 can be used with a single Bus Coupler or a Bus Terminal Controller. The KL6401 supports 62 SNVTs. All SNVT types can be configured as input or output variable via the KS2000 software. The KS2000 software generates an XIF file that is integrated in an LON tool.
The MP-Bus master terminal enables direct connection of MP-Bus slave devices. Up to sixteen field devices, eight drives and eight sensors can be connected to the KL6771. The Bus Terminal is configured and commissioned via TwinCAT function blocks. Several KL6771 terminals can be connected to the same Bus Coupler or Bus Terminal Controller.
The KL6811 enables the connection of up to 64 DALI slaves. The KS2000 software enables simple configuration via a PC that is directly coupled with the Bus Coupler via an RS232 interface or via the fieldbus. The integrated power supply unit generates an electrically isolated 24 V DC output voltage. No further components are required for the operation of the DALI slaves. The KL6811 operates fieldbus-independent.
Nominal voltage
24 V DC (-15 %/+20 %)
24 V DC (-15 %/+20 %)
24 V DC (-15 %/+20 %)
Current consum. pow.cont.
only load typ. 10 mA + load typ. 30 mA + load
Current consumpt. K-bus typ. 55 mA typ. 55 mA typ. 55 mA
Data transfer standard
FTT-10, LPT
MP-Bus
DALI
Special features
15 devices;
8 drives/sensors;
connection of up to 64 DALI slaves;
TwinCAT library available
TwinCAT library available
TwinCAT library available
Operating temperature
0…+55 °C
0…+55 °C
0…+55 °C
Approvals
CE, Ex
CE, UL, Ex
CE, UL, Ex
Weight approx. 85 g approx. 85 g approx. 80 g
Further information www.beckhoff.com/KL6401 www.beckhoff.com/KL6771 www.beckhoff.com/KL6811
BECKHOFF New Automation Technology
We reserve the right to make technical changes.
Page 132
KL6904
Communication
Communication | TwinSAFE TwinSAFE enables networks with up to 1,024 TwinSAFE devices. The KL6904 Bus Terminal features certified safety function blocks, which are configured according to the application to be realised. Functions such as emergency stop, safety door monitoring etc. can thus easily be selected and linked. All blocks can be freely connected among each other and are complemented by operators such as AND, OR, etc. The necessary functions are configured using the TwinCAT System Manager and loaded into the terminal via the fieldbus.
TwinSAFE Logic Bus Terminal, 4 safe inputs
Technical data
KL6904
Technology
TwinSAFE Logic
Safety standard
IEC 61508 SIL 3 and DIN EN ISO 13849-1:2008 PLe
Number of outputs
4
Protocol
TwinSAFE/FSoE
1
5
2
6
3
7
Bus Terminal
For further information on TwinSAFE and the TwinSAFE products see page 828
4
8
591
The KL6904 TwinSAFE Logic Bus Terminal can establish 15 connections (TwinSAFE connections). The TwinSAFE logic terminal has four safe, local outputs, so that safety applications can be realised with only two components (KL1904 and KL6904). Nominal voltage
24 V DC (-15 %/+20 %)
Current consum. pow.cont.
load-dependent
Current consumpt. K-bus
250 mA
Cycle time
4…100 ms
Fault response time
≤ watchdog time (parameterisable)
Output current
0.5 A max./20 mA min. (per channel)
Permiss. degree
2 of contamination
We reserve the right to make technical changes.
Climate class EN60721-3-3
3K3
Installation position horizontal
Special features
4 safe outputs
Operating temperature
0…+55 °C
Electrical interference
EN 61000-6-2/EN 61000-6-4
Vibration/shock resistance
EN 60068-2-6/EN 60068-2-27/29
Approvals
CE, UL, Ex, TÜV Süd
Weight approx. 90 g
Further information www.beckhoff.com/KL6904
Special terminals
KL6904-0001
Distinguishing features preconfigured ex factory to 15 TwinSAFE connections
BECKHOFF New Automation Technology
Page 133
Power Terminals
KL8001
Bus Terminal
Power terminals | Siemens contactor, series Sirius 3R
592
The KL8001 power terminal, together with a power contactor, forms a complete distributed motor starter with any fieldbus connection. Apart from all the protective functions of a motor protection relay, the power terminal contains comprehensive diagnostics. By means of values such as current, voltage, active-power input and apparent power consumption or load condition, the control programmer is able to regulate the drive or a machine component in the best possible way and to protect them from damage and failure. The Bus Terminal block is fitted with a KL9060 adapter terminal instead of a KL9010 end terminal. The KL9060 is connected to a power terminal using a simple ribbon cable. Up to ten power terminals can be driven by one KL9060. No other wiring is necessary apart from a ground cable. The power terminal switches the installed contactor and takes over all the functions of the motor protection relay. Apart from its purely protective function of switching off the motor when overloaded, the power terminal can carry out numerous diagnostic functions on the motor and make the information available to the controller via the fieldbus. KL9060 | End terminal with adapter connection for KL8001 power terminals see page 598
Power terminal for Siemens contactor, series Sirius 3R
Technical data
KL8001
Contactor connection mechanism for Siemens contactor series Sirius 3R (switch size S00, Typ 3RT 10 1)
Measured values current, voltage, power
Number of up to 10 (at 140 mA typ. current consumption per contactor)
power terminals
Like a standard motor protection relay the KL8001 power terminal is fitted to a power contactor up to a switching capacity of 5.5 kW. Measuring accuracy
0.1 A AC
Current consumption typ. 7 mA + load power contacts Current consumpt. K-bus typ. 150 mA
Measuring voltage
500 V AC
Power contacts
24 V DC (-15 %/+20 %)/1.4 A max., short-circuit-proof
Setting range of
0.9…9.9 A nominal current Current load max. 25 A (fuse)
Short-circuit-proof up to 5 kA
Internal resistance
< 1 mΩ
Tripping classes class 5, 10, 15, 20, 25, 30 selectable
Type of connection screw terminals up to 2 x 2.5 mm² power path
BECKHOFF New Automation Technology
Type of K-bus connection
2 x flat plug socket, 10-pin
Adapter terminal
KL9060
Short circuit behaviour conforms to EN 60947-4-1 (assignment type 2)/VDE 102
Triggering tolerance conforms to IEC 947, as well as UL and CSA
Operating temperature
0…+55 °C
Approvals
CE
Weight approx. 90 g
Further information www.beckhoff.com/KL8001
We reserve the right to make technical changes.
Page 134
KL8601, KL8610
Power Terminals
Power terminals | TeSys U Communication
Adapter terminal module for TeSys U for TeSys U
Technical data
KL8601
KL8610
Communication unit
TeSys U, all control devices
KL8601
(standard, expanded and multi-functional) Number of modules up to 8 TeSys model U up to 8 KL8601 TeSys model U
Number of outputs
2 (digital 24 V DC)
–
Bus Terminal
The TeSys series from Schneider Electric/ Télémécanique is a product family for the protection and switching of motors. Model U is a very compact motor starter that can be connected directly to the Bus Terminal system via the KL8601 communication module from Beckhoff. Users of TeSys modules therefore have the complete fieldbus range of the Bus Terminal system available. Similar to the KL8001 power terminal from Beckhoff, the motor starter integrates seamlessly into the terminal bus. The motor starter is integrated into the fieldbus system via the KL8610 adapter terminal and a common, screened RJ 45 cable. The 24 V DC supply of the contactor systems is also transferred via this patch cable. The maximum distance between the KL8610 and the first motor starter module is 5 m; the maximum distance between two starters is 0.5 m. Up to eight starters can be connected in series. Spatial separation of I/O and power plane can thus be realised within the control cabinet. Note: The KL8601 communication module, the KL8610 adapter terminal and the accessory cable can be ordered via Schneider Electric/Télémécanique and Beckhoff. The TeSys motor starters are only available from Schneider Electric, the Bus Terminal system only from Beckhoff.
593
The KL8601 communication module is plugged into the TeSys Model U motor starter. It connects the starter with the KL8610 adapter terminal and further motor starters with communication module. The KL8610 adapter terminal provides the connection with the Bus Terminal system. The control and status information of the motor starter evaluation unit are transferred to the Bus Terminal system via the KL8601 communication module.
The KL8610 adapter terminal enables the connection of the TeSys Model U motor starter to the Beckhoff Bus Terminal system. Together with the KL8601 communication module, the KL8610 forms an operational unit in the TeSys motor starter. The KL8610 adapter terminal is attached to the end of the bus terminal block. No further parameterising or configuration work on the KL8610 is necessary apart from plugging-in the connecting cable.
Voltage
–
24 V DC (-15 %/+20 %)
Current consumption
20 mA + load current,
– system bus max. 2 x 0.5 A
Current consumpt. K-bus
–
Output current
0.5 A short-circuit-proof
–
Current load
– max. 2 A short-circuit-proof
Operating temperature
0…+55 °C
0…+55 °C
Motor starter TeSys U
Approvals
CE
CE
Further information can be found on the
Weight approx. 70 g approx. 65 g
Internet at: www.schneider-electric.com
Further information www.beckhoff.com/KL8601 www.beckhoff.com/KL8610
We reserve the right to make technical changes.
typ. 32 mA
BECKHOFF New Automation Technology
Page 135
System Terminals
KL91xx
Bus Terminal
KL91xx, KL92xx | Function terminals
594
The power feed terminals make it possible to set up various potential groups with any desired voltages (KL9190) or with the standard voltages of 24 V DC or 230 V AC (120 V AC). The power feed terminals are available with or without fine-wire fuse. In order to monitor the supply voltage, the terminals with diagnostics report the status of the power feed terminal to the Bus Coupler through two input bits. It is thus possible for the controller to check the distributed peripheral voltage over the fieldbus. The operating point performance conforms to the input terminals KL1002 (24 V) and KL1702 (230 V). The KL9180, KL9185 and KL9195 Bus Terminals allow the supply voltage to be accessed a number of times via spring force terminals. These Bus Terminals make it unnecessary to use additional terminal blocks on the terminal strip. The KL9195 Bus Terminal can be used for the connection of screens. The KL9195 connects the spring force contacts directly to the DIN rail, and can optimally ground incoming electromagnetic radiation. The two power contacts are looped through by the KL9195, allowing two wires to be connected to each power contact. The KL9010 bus end terminal is necessary for data exchange between the Bus Coupler and the Bus Terminals. Each assembly must be terminated at the right hand end with a KL9010 bus end terminal. The bus end terminal does not have any other function or connection facility. The KL9080 is used to identify potential groups (e.g. 230 V AC/ 24 V DC). It is inserted between two potential groups, and indicates the separation through an orange coloured cover.
Potential
Potential
Potential
Potential
Potential supply supply supply supply supply terminal, terminal, terminal, terminal, terminal,
24 V DC
24 V DC,
120…
120…230 V any voltage with
230 V AC
AC, with up to diagnostics
230 V AC diagnostics Technical data
KL9100 |
KL9110 |
KL9150 |
KL9160 |
KL9190 |
KS9100
KS9110
KS9150
KS9160
KS9190
– yes
–
120 V AC/
120 V AC/ arbitrary
230 V AC
230 V AC
Technology potential supply terminal
Diagnostics in the
– yes process image
Nominal voltage
+60 °C
+60 °C
-20 °C
-20 °C
24 V DC
24 V DC
Current load
≤ 10 A
≤ 10 A
≤ 10 A
≤ 10 A
≤ 10 A
Integrated fine-wire fuse
–
–
–
–
–
Power LED green green green green
–
Defect LED
–
–
–
–
–
PE contact yes yes yes yes yes
Shield connection
–
–
–
–
–
Current consumption
– typ. 10 mA
– typ. 10 mA
–
Electrical isolation yes yes yes yes yes
Connection to DIN rail
–
–
–
–
–
Special features
–
–
–
–
–
Operating temperature
-20…+60 °C
-20…+60 °C
0…+55 °C
0…+55 °C
0…+55 °C
Approvals
CE, UL, Ex, GL
CE, UL, Ex, GL
CE, UL, GL
CE, UL, GL
CE, UL, Ex, GL
Weight approx. 50 g approx. 50 g approx. 50 g approx. 50 g approx. 50 g
Further information www.
www.
www.
www.
www.
beckhoff.com/ beckhoff.com/ beckhoff.com/ beckhoff.com/ beckhoff.com/
KL9100
KL9110
KL9150
KL9160
KL9190
K-bus
BECKHOFF New Automation Technology
We reserve the right to make technical changes.
Page 136
KL9xxx
System Terminals
Potential
Potential
Potential
Potential
Potential
Shield
Shield
Separation supply terminal, supply terminal, supply terminal, supply terminal, supply terminal, terminal terminal terminal
24 V DC,
24 V DC,
120…230 V AC,
120…230 V AC, arbitrary, with fuse with diagnostics with fuse with diagnostics with fuse
KL9080 and fuse
KL9200 and fuse
KL9210
KL9250
KL9260
KL9290
KL9070 |
KL9195 |
KS9070
KS9195 shield terminal shield terminal separation terminal yes
– yes
–
+60 °C
+60 °C
-20 °C
-20 °C
1
5
2
6
3
7
4
8
Bus Terminal
–
595
24 V DC
24 V DC
120 V AC/
120 V AC/ arbitrary up to
230 V AC
230 V AC
230 V AC/DC
≤ 60 V arbitrary up to separation
230 V AC terminal
≤ 10 A
≤ 10 A
≤ 10 A
≤ 10 A
≤ 10 A
≤ 10 A
≤ 10 A
–
…6.3 A
…6.3 A
…6.3 A
…6.3 A
…6.3 A
–
–
– green green green green
–
–
–
– red red red red
–
–
–
– yes yes yes yes yes
–
–
–
–
–
–
–
–
8x
2x
–
– typ. 10 mA
– typ. 10 mA
–
–
–
– yes yes yes yes yes yes
–
–
–
–
–
–
– yes yes
–
– integrated fuse integrated fuse integrated fuse integrated fuse dissipation of
– placeholder ter-
EMC interference minal with K-bus via large copper transmission surfaces on the DIN rail 0…+55 °C
-20…+60 °C
0…+55 °C
0…+55 °C
0…+55 °C
0…+55 °C
0…+55 °C
-20…+60 °C
CE, UL, Ex, GL
CE, UL, Ex, GL
CE, UL, Ex, GL
CE, UL, Ex, GL
CE, UL, Ex, GL
CE, UL, Ex
CE, UL, Ex, GL
CE, UL, Ex, GL approx. 50 g approx. 55 g approx. 55 g approx. 55 g approx. 50 g approx. 50 g approx. 50 g approx. 50 g www.
www.
www.
www.
www.
www.
www.
www.
beckhoff.com/ beckhoff.com/ beckhoff.com/ beckhoff.com/ beckhoff.com/ beckhoff.com/ beckhoff.com/ beckhoff.com/
KL9200
KL9210
KL9250
KL9260
KL9290
KL9070
KL9195
KL9080
We reserve the right to make technical changes.
BECKHOFF New Automation Technology
Page 137
System Terminals
KL9180, KL9185
KL91xx | Function terminals, potential distribution Potential distribution
Potential distribution terminal, 2 terminal points terminal, 4 terminal points per power contact at 2 power contacts
Technical data
KL9180 | KS9180
KL9185 | KS9185
Technology potential distribution terminal
Diagnostics in the
– process image
Bus Terminal
The KL91xx potential distribution terminals enable – depending upon the type – the distribution of ground or supply potentials to external devices. Wiring work and separate potential distributors are saved. Eight ground points are required for the ground connection of 8-channel output terminals in 2-wire operating mode, e.g. KL2008, for which the KL9187 can be used. The KL9184 and KL9188 HD Bus Terminals (High Density) even make 16 connection points available in a compact housing.
596
Nominal voltage arbitrary up to arbitrary up to
230 V AC
230 V AC
Current load
≤ 10 A
≤ 10 A
Integrated fine-wire fuse
–
–
Power LED
–
–
Defect LED
–
–
PE contact yes
–
Shield connection
–
–
Current consumption
–
–
Electrical isolation
–
–
Connection to DIN rail
–
–
Special features
–
–
Operating temperature
0…+55 °C
0…+55 °C
Approvals
CE, UL, Ex, GL
CE, UL, Ex, GL
Weight approx. 50 g approx. 50 g
Further information www.beckhoff.com/KL9180 www.beckhoff.com/KL9185
K-bus
BECKHOFF New Automation Technology
We reserve the right to make technical changes.
Page 138
System Terminals
Potential distribution
Potential distribution
Potential distribution
Potential distribution
Potential distribution terminal, 8 x 24 V terminal, 8 x 0 V terminal, 8 x 24 V, 8 x 0 V terminal, 16 x 24 V terminal, 16 x 0 V
KL9186 | KS9186
KL9187 | KS9187
KL9184
KL9188
KL9189
+24 V
1
5
+60 °C
+60 °C
-20 °C
-20 °C
+24 V
0V
1
5
0V
+24 V 1
2
+24 V
2
6
+24 V
0V
+24 V
0V
2
6
3
11
4
12
5
13
6
14
+24 V +24 V
3
7
3
7
+24 V
0V
+24 V +24 V +24 V
4
8
+24 V
0V
4
8
0V
+24 V
0V
+24 V
0V
+24 V
1
10
+24 V
0V
0V 9
+24 V
7
15
8
16
+24 V
2
0V
+24 V
0V
+24 V
0V
+24 V
0V
+24 V
0V
+24 V
+24 V
0V
+24 V
0V
+24 V
0V
9
10
3
11
4
12
5
13
6
14
7
15
8
16
+24 V
0V
+24 V
0V
+24 V
0V
+24 V
0V
+24 V
0V
0V 1
9
2
10
3
11
4
12
5
13
6
14
7
15
8
16
0V 0V
0V 0V
0V 0V 0V
Bus Terminal
KL91xx
597
≤ 60 V DC
≤ 60 V DC
≤ 60 V DC
≤ 60 V DC
≤ 60 V DC
≤ 10 A
≤ 10 A
≤ 10 A
≤ 10 A
≤ 10 A
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
– yes yes yes yes yes
–
–
–
–
–
8 x 24 V connection
8 x 0 V connection
8 x 24 V and 8 x 0 V
16 x 24 V connection
16 x 0 V connection connection -20…+60 °C
-20…+60 °C
0…+55 °C
0…+55 °C
0…+55 °C
CE, UL, Ex, GL
CE, UL, Ex, GL
CE, Ex
CE, Ex
CE, Ex approx. 50 g approx. 50 g approx. 60 g approx. 60 g approx. 60 g www.beckhoff.com/KL9186 www.beckhoff.com/KL9187 www.beckhoff.com/KL9184 www.beckhoff.com/KL9188 www.beckhoff.com/KL9189
We reserve the right to make technical changes.
BECKHOFF New Automation Technology
Page 139
System Terminals
KL90xx
KL90xx | Function terminals End terminal
Adapter terminal
End terminal
Coupler terminal for KL8001 power terminals for bus extension for bus extension
KL9060
KL9020
KL9050
Technical data
KL9010
Technology end terminal coupler terminal
Diagnostics in the
– yes process image +60 °C
Bus Terminal
-20 °C
598
The KL9060 Bus Terminal enables a connection to the KL8001. For further information see page 592
The KL9020 forms a properly working unit together with at least one KL9050. No further parameterisation or configuration work is necessary.
The KL9050 coupler terminal replaces the Bus Coupler on a Bus Terminal block. The second RJ 45 socket allows the system to be extended further. The whole system can be extended by 31 stations.
Nominal voltage
–
24 V DC (-15 %/+20 %)
24 V DC (-15 %/+20 %)
24 V DC (-15 %/+20 %)
Current load
–
≤ 10 A
≤ 10 A
≤ 10 A
Power LED
–
–
– green
Defect LED
–
–
–
–
PE contact
– yes
– yes
Current consumption
–
– typ. 70 mA typ. 70 mA + (total K-bus
–
– max. 5 m between max. 5 m between
KL9020 and KL9050
KL9050 and KL9050
K-bus Distance between current)/4, max. 200 mA stations Starting current
–
–
–
2.5 x continuous current
Current supply K-bus
–
–
– up to 400 mA
Electrical isolation
–
500 V (power contact/
500 V (power contact/
500 V (power contact/ supply voltage/K-bus)
supply voltage/K-bus)
supply voltage/fieldbus)
end terminal for connection to KL8001 via end terminal coupler terminal bus communication
20-pin flat ribbon plug for K-bus extension for K-bus extension
Operating temperature
-20…+60 °C
0…+55 °C
0…+55 °C
0…+55 °C
Approvals
CE, UL, Ex, GL
CE
CE, UL, Ex, GL
CE, Ex, GL
Weight approx. 50 g approx. 65 g approx. 45 g approx. 75 g
Further information www.beckhoff.com/KL9010 www.beckhoff.com/KL9060 www.beckhoff.com/KL9020 www.beckhoff.com/KL9050
Special features
(max. 64 Bus Terminals)
BECKHOFF New Automation Technology
We reserve the right to make technical changes.
Page 140
KL93xx
System Terminals
KL93xx | Diode array Bus Terminals Diode array terminal,
Diode array terminal,
Diode array terminal,
4 potential-free diodes
7 diodes (with a com-
7 diodes (with a com- mon cathode)
mon anode)
KL9301 | KS9301
KL9302 | KS9302
Technical data
KL9300 | KS9300
Technology free-wheeling or decoupling diodes
Number of diodes
4
7
Interconnection potential-free common cathode common anode
1
5
1
5
1
5
2
6
2
6
2
6
3
7
3
7
3
7
4
8
4
8
4
8
Bus Terminal
Diodes perform different tasks in control circuits. They decouple, rectify or provide for the freerunning of a coil. The Bus Terminals unite diodes in different circuits and simplify integration into the control cabinet by their compact design. The circuits offered, with common anode or cathode and the individual diodes, minimise the wiring effort in the control cabinet.
599
Nominal cut-off voltage
1,000 V (diodes)
1,000 V (diodes)
1,000 V (diodes)
Output current
1 A on each diode
1 A on each diode
1 A on each diode
Peak current
2.5 A (100 ms)
2.5 A (100 ms)
2.5 A (100 ms)
Voltage drop
0.7 V typ.
0.7 V typ.
0.7 V typ.
Current consumption
–
–
–
< 200 V
< 200 V
< 200 V
(channel/channel)
(channel/channel)
(channel/channel)
Electrical isolation
1,500 V (K-bus/field)
1,500 V (K-bus/field)
1,500 V (K-bus/field)
Operating temperature
0…+55 °C
0…+55 °C
0…+55 °C
Approvals
CE, UL, Ex
CE, UL, Ex
CE, UL, Ex
Weight approx. 50 g approx. 55 g approx. 55 g
Further information www.beckhoff.com/ www.beckhoff.com/ www.beckhoff.com/
KL9300
KL9301
KL9302
K-bus Isolation voltage
We reserve the right to make technical changes.
BECKHOFF New Automation Technology